Entrevista Raúl Álvarez - Cigre mp4
21:11
Megger TAU3
0:54
2 ай бұрын
Megger DELTA4000
0:39
2 ай бұрын
Esto es Power Diagnostix
4:52
2 ай бұрын
Пікірлер
@mariodalmasso64
@mariodalmasso64 12 күн бұрын
muy buena explicación. consulto sobre el método de la pendiente, no me quedo claro, podré recibir información al respecto? muchas gracias.
@Rogeri-k3x
@Rogeri-k3x 14 күн бұрын
🎯 Key points for quick navigation: 00:01 *Impedance testing overview* 00:15 *Introductions and questions* 00:56 *Webinar recording announcement* 01:25 *Agenda highlights discussed* 02:22 *Battery month promotion* 02:49 *Equipment overview introduction* 04:12 *Introduction of experts* 05:47 *Analysis importance emphasized* 06:55 *Importance of batteries* 08:43 *Less frequent maintenance* 09:49 *Impedance test standards* 10:45 *Inspection visual limitations* 12:19 *Emergency backup systems* 13:53 *Regulation compliance importance* 14:32 *Cost-effective impedance testing* 15:27 *Importance of practices* 17:30 *Current injection principle* 19:27 *Multiple measurements capability* 23:57 *Check terminal connections.* 24:12 *Ensure current continuity.* 24:27 *Measure injection current.* 24:40 *Apply tension sensor.* 24:52 *Record voltage drop.* 25:06 *Measure entire bank.* 25:19 *Analyze data quickly.* 25:32 *Data logger usage.* 25:45 *Generate paper report.* 26:28 *Review additional data.* 27:23 *Recommended practices importance.* 27:50 *Battery preparation necessary.* 28:31 *Charge level affects.* 29:10 *Ensure battery charge.* 29:51 *Temperature impacts resistance.* 30:31 *Wait 72 hours.* 31:09 *Measure post to post.* 31:48 *Use proper accessories.* 32:27 *Avoid additional resistance.* 32:55 *Measure post connections.* 33:43 *Ensure stable results.* 34:28 *Verify in-field results.* 35:38 *Review impedance values.* 38:14 *Check battery current.* 39:32 *Identify charging errors.* 40:15 *Harmful ripple currents.* 41:08 *Verify charger settings.* 43:00 *Voltage impacts longevity.* 44:50 *Serious impedance review.* 46:13 *Interconnection resistance impacts.* 01:11:18 *Stable impedance analysis* 01:12:25 *Identify cell issues* 01:13:57 *Reference value importance* 01:14:25 *Capacity loss assessment* 01:15:22 *Reference value timing* 01:17:14 *Accurate measurement criteria* 01:18:18 *Bank-specific references* 01:20:09 *Impedance deviation monitoring* 01:21:17 *Battery replacement indicators* 01:23:09 *Data management techniques* 01:23:51 *Integrated data analysis* 01:25:12 *Compliance monitoring tools* 01:26:21 *Reliable testing advice* 01:28:28 *Equipment comparison details* 01:31:11 *Upcoming webinar announcement* 01:32:40 *Energy congress invitation* Made with HARPA AI
@hecthorgomezbello5365
@hecthorgomezbello5365 15 күн бұрын
Buen día. Agradecería si puedes indicar alguna NORMA que hable sobre el RECINTO o CUARTO DEL BANCO DE BATERIA. acorde a la Cantidad de baterías (Capacidad Operativa) y TIPO , a ubicarse en este sitio. Gracias.
@JPRIMOB
@JPRIMOB 15 күн бұрын
si me gustaria saber que pasa cuando hay 4 puentes como medimos la corriente de rizo
@danielperea312
@danielperea312 Ай бұрын
buenas tardes. Una pregunta, menciona que para hacer la prueba de IR en motores trifásicos, las líneas deben estar abiertas, pero que hacemos cuando el motor viene con solo 3 puntas y la conexión esta por dentro del motor. de antemano muchas gracias
@joselinchaparro2014
@joselinchaparro2014 2 ай бұрын
Excelente!!!!!!!!!!!!!!!!........................................😃😃😃🙃🙃
@AnthonyAxelChoquehuancaLoyola
@AnthonyAxelChoquehuancaLoyola 2 ай бұрын
Excelente, muy bien explicado.
@eminhasanli7358
@eminhasanli7358 2 ай бұрын
Super! We are "Fleetstock" company very glad to be your distributor in Azerbaijan.
@niltonxavierespinozachoque8576
@niltonxavierespinozachoque8576 3 ай бұрын
Excelente
@johncabrera5082
@johncabrera5082 3 ай бұрын
Distribuidor en Ecuador??
@MeggerLATAM
@MeggerLATAM 3 ай бұрын
hola estimado buenas tardes. En Ecuador, TMRS es nuestro representante. Puedes comunicarte con Sofia Arcentales ([email protected])
@nicolascifuentes9041
@nicolascifuentes9041 3 ай бұрын
Excellent DGA!!
@oscarramondiaz
@oscarramondiaz 3 ай бұрын
Gracias por siempre darnos información
@johnnunez4250
@johnnunez4250 3 ай бұрын
Hola, quisiera saber cuándo subirán el vídeo del webinar que acaba de terminar hoy donde se habló de la prueba de SFRA?.
@oscarramondiaz
@oscarramondiaz 3 ай бұрын
Siempre muy agradecido de tener tan información dada por los webinar
@DanteIzquierdo-jf5gz
@DanteIzquierdo-jf5gz 4 ай бұрын
tema interesante, pero la música de fondo es muy invasiva.
@hact
@hact 4 ай бұрын
Hola, me pueden comentar cual es la normativa de referencia para la ejecución de esta prueba?
@jeanluque3
@jeanluque3 4 ай бұрын
Muy buena explicación sobre los métodos para la medición de puesta a tierra.
@RollersJuan
@RollersJuan 5 ай бұрын
hay algún limitante con respecto a su tensión nominal y potencia, a la hora de hacer descargas parciales en un motor? por ejemplo le puedo hacer descargas parciales a un motor chico de 380 v y 2 hp?
@RollersJuan
@RollersJuan 5 ай бұрын
muy bueno
@RollersJuan
@RollersJuan 5 ай бұрын
muy bueno
@angelguillermomaytacontrer1606
@angelguillermomaytacontrer1606 5 ай бұрын
Acabo de ver una exposición en medición de puesto a tierra y encontré una buena explicación.
@JOHNBUENOri
@JOHNBUENOri 5 ай бұрын
¡Felicitaciones! Se aprende mucho con este tipo de contenido, ¿donde se puede descargar el poster que se aprecia en la parte de atras? Ya que en el link solo se puede descargar el catálogo de transformadores.
@Vibeland
@Vibeland 5 ай бұрын
Muy buena información. Agradecido por el aporte.
@milagrossolorzanomacizo1877
@milagrossolorzanomacizo1877 5 ай бұрын
Consulta en el trax 220 se puede medir un transformador en delta delta?? Solo vi ejemplos delta estrella pero no delta delta
@juliocesarjimenezcampos1015
@juliocesarjimenezcampos1015 5 ай бұрын
Que amena charla y enriquecedora. Un gusto siempre escuchar al Dr. Robalino hablar sobre transformadores sobretodo de donde venimos, donde estamos y a donde vamos. Y por supuesto mención especial a nuestra moderadora estrella Daniela, impecable tu trabajo. Felicitaciones a ambos!!!
@MeggerLATAM
@MeggerLATAM 5 ай бұрын
Muhas gracias por tus comentarios Julio
@miguelmontenegro-n1q
@miguelmontenegro-n1q 5 ай бұрын
excelente
@genarocaruzzo1887
@genarocaruzzo1887 6 ай бұрын
Hola, puede ser que en la filmina del minuto 34:13 no sea correcta la información? Dado que verificando las normas mencionadas no encuentro en ningún sitio que la prueba deba ser de 10 min ni tampoco indicaciones acerca de la "current leakage". Saludos
@herarob18
@herarob18 6 ай бұрын
Saludos, estoy viendo en diferido el contenido, quisiera saber si dentro de su gama de productos tendrán un relé de monitoreo del cable de tierra, en algunas otras marcas he visto que su nombre es "ground check relay" Gracias por su respuesta
@MeggerLATAM
@MeggerLATAM 6 ай бұрын
Saludos estimado, nosotros no tenemos relés, pero si equipos que verifican el conductor de tierra, como es el DET20C. No es un dispositivo que se deja fijo, sino que realiza mediciones puntuales y periódicas. Si desea más información, favor de mandarnos un email a [email protected]
@MolochJanus
@MolochJanus 6 ай бұрын
1:41..😮😮😮 el número aureo
@juancarloshurtado
@juancarloshurtado 6 ай бұрын
Excelente Megger gracias 🙂
@MiguelMoreno-ke1ml
@MiguelMoreno-ke1ml 6 ай бұрын
Excelente episodio
@juancarloshurtado
@juancarloshurtado 6 ай бұрын
Excelente Megger gracias
@juancarloshurtado
@juancarloshurtado 8 ай бұрын
Excelente Megger LATAM muy bien gracias
@joselinchaparro2014
@joselinchaparro2014 8 ай бұрын
EXCELENTE, muy interesante y aplicable.
@ignaciotorres3694
@ignaciotorres3694 8 ай бұрын
Muy bueno
@user-io9vb8qc4o
@user-io9vb8qc4o 9 ай бұрын
Excelente sistema de pruebas para transformadores. MultiPruebas, utiliza el TRAX220+TDX-120.
@juancarloshurtado
@juancarloshurtado 9 ай бұрын
Excelente Megger LATAM Webinar
@juancarloshurtado
@juancarloshurtado 10 ай бұрын
Excelente Megger LATAM Webinar
@oscarramondiaz
@oscarramondiaz 10 ай бұрын
Buenas tardes Oscar Díaz desde Venezuela
@ajazahmad582
@ajazahmad582 10 ай бұрын
Excellent very nice Veido on megger. Unfortunately, I can't understand your language.
@juancarloshurtado
@juancarloshurtado 10 ай бұрын
Excelente Megger LATAM
@juancarloshurtado
@juancarloshurtado 10 ай бұрын
Excelente Megger LATAM Webinar ⚡
@ignacioprovoste8835
@ignacioprovoste8835 11 ай бұрын
Hola , una consulta como calcula la diagonal de una MPT irregular ? Saludo
@wjimenezu
@wjimenezu 11 ай бұрын
Muy profesionales estos webinars
@juancarloshurtado
@juancarloshurtado 11 ай бұрын
Excelente Megger LATAM Webinar
@luisyahelramirezperez9921
@luisyahelramirezperez9921 11 ай бұрын
🎯 Key Takeaways for quick navigation: 00:00 📅 This webinar discusses photovoltaic system testing, fault location, insulation tests, and equipotential systems. 01:23 📧 The session will be recorded, and participants will receive a link to the recording and a certificate of attendance. The audience can also fill out a survey and request presentation and technical article copies. 03:48 👩‍💼 The host is Daniela de Vacas, the marketing specialist for Latin America, and the panelist is Engineer Julio Jiménez, who is currently experiencing technical issues. 08:11 🌞 Common photovoltaic system failures include connector issues, module glass breakage, incorrect or missing installations, cable damage, and more. 12:28 📊 An audience poll asks about the types of inspections they perform on photovoltaic systems, including visual inspection, continuity, polarity, voltage, current, insulation resistance, and more. 16:17 📜 Various international standards and guidelines govern photovoltaic system testing and maintenance, with IEC 62446 being a significant one. 18:05 🧪 IEC 62446 divides photovoltaic system testing into categories, including visual inspection, continuity, polarity, voltage, and short-circuit tests, with additional optional tests for specific systems. 18:47 📊 Historical data management is crucial for making informed decisions about photovoltaic systems. 19:13 🔍 Additional tests for fault localization include curve tracing and thermography, with specific thermal resolution requirements. 21:40 🕵️ Visual inspection is essential for detecting issues in large photovoltaic parks, especially with visually detectable panels. 22:23 ⚡ Transition towards thermography has increased due to ease of recording with drones or manual cameras. 25:13 📏 Clamp meters are advantageous for measuring current without interrupting circuits and offer Bluetooth data transfer capabilities. 26:10 ☀️ Irradiance meters help assess the performance of solar panels in the field. 26:51 🌡️ Thermal imaging identifies abnormal visual effects, such as hotspots and diode issues in panels. 29:24 📈 Increasing voltage levels above 1500V in photovoltaic systems presents challenges due to limited measurement instruments. 30:49 🤝 Continuity tests during earth resistance measurements can be a healthy practice to detect issues. 31:46 ⚡ Different methods, such as two-terminal, three-terminal, and four-terminal, are used to measure resistance, each with its applicable range and limitations. 36:07 🧲 Four-terminal measurements involve special probes that ensure effective contact and eliminate corrosion, especially important for aluminum components in photovoltaic systems. 36:52 ⚡ Conducting four-terminal tests in photovoltaic systems can eliminate resistance, allowing for testing over long distances and detection of small connection changes. 38:29 🔥 Increasing current and temperature can lead to increased resistance and power losses in electrical systems. 43:36 🌞 Thermal imaging inspections should ideally be performed from both sides of solar panels for a more comprehensive assessment. 45:24 💡 Terminal guard usage is common in insulation testing, helping detect changes in resistance and identifying potential faults. 49:45 🔄 Random testing of solar panels in the field is essential to ensure they are in good condition. 52:19 🔌 Proper connector selection and installation are crucial to prevent hot spots and ensure system reliability. 54:22 📏 The recommended insulation resistance values depend on the system, but practical experience often suggests higher standards for reliability. 54:49 🔌 Pruebas de continuidad son importantes para verificar conexiones eléctricas y evitar fallas en sistemas fotovoltaicos. 55:57 💡 Resistencias de baja continuidad (5,000 ohmios or less) entre tablas y 100,000 ohmios entre strings son indicativas de conexiones adecuadas en sistemas fotovoltaicos. 58:38 🛠️ Asegurar conexiones eléctricas en aluminio anodizado utilizando tornillos o perforaciones es esencial para garantizar la continuidad en sistemas fotovoltaicos. 01:00:16 📊 Electroluminiscencia es una prueba de laboratorio que evalúa el funcionamiento individual de celdas solares en paneles fotovoltaicos. 01:07:24 ⚡️ El cable de guarda (guard wire) en medidores de aislamiento aísla corrientes de fuga superficiales para obtener mediciones precisas. 01:09:06 🚧 Cambiar conectores en puntos calientes es aconsejable en lugar de repararlos debido a la complejidad y garantía de una correcta distribución térmica. 01:10:20 🔍 Un multímetro puede ser válido para medir resistencia de continuidad en ausencia de un medidor de cuatro puntas, pero es importante mantener registros y observar cambios mínimos. 01:12:26 📅 You can contact the presenter for product information using the calendar icon shown on the screen. 01:12:55 🔌 Electroluminescence testing can be done randomly to check the status of solar panels, and it's advisable for the initial testing of panels received. 01:13:38 🏢 Electroluminescence tests are commonly performed in the field due to the presence of more issues, but they are typically done in a laboratory. 01:14:17 🔍 There are different clamp models for measuring DC current in solar systems, such as bcm 1500s and dpm mil, suitable for various current levels. 01:15:23 ⚡ These clamps are safe for measuring up to 1500 volts and come with impedance adapters to connect directly to photovoltaic connectors. 01:16:01 🧪 Solar system testing can be done at various levels, including combiner boxes, inverters, strings, or individual panels, depending on the installation. 01:17:16 ⚡ The grounding of the enclosure in a solar park depends on the approved design, and it can be interconnected with the photovoltaic system's potential equipment or kept separate. 01:19:26 📝 There are guidelines for safe isolation procedures during testing, but it's recommended to follow local electrical safety standards and the ANSI/IEEE 62.446 standard. 01:21:06 📅 Solar panels are typically guaranteed for 20 years by manufacturers, but their actual lifespan can extend beyond that. 01:24:49 🌞 For thermography in solar systems, it's most effective during peak sunlight hours when irradiance levels are high, revealing issues like hotspots. 01:26:02 📋 During commissioning and operation, various tests should be conducted according to the ANSI/IEEE 62.446 standard, comparing results to design specifications. Regular visual inspections and maintenance are essential. 01:29:37 📅 Field visits and suggestions for future webinars are welcome, and the presenter's email address is available for further inquiries. 01:30:08 📩 You can request a copy of the presentation PDF in the survey, and the webinar recording will be emailed along with certificates the next day. Made with HARPA AI
@juancarloshurtado
@juancarloshurtado Жыл бұрын
Excelente Megger LATAM Webinar
@wjimenezu
@wjimenezu Жыл бұрын
Buen tema. Muy intuitivos los diagramas. Me quedó la inquietud de si en los análisis que hace el equipo (SBERKER si mal no recuerdo) está la de poder determinar la eficiencia o calidad de respuesta de un sistema de energía renovable para atender una carga o factor de potencia en un rango específico o si esa situaciones pasa a ser un asunto más de cálculos y diseños en la ingeniería.
@user-kt2xv8zc4k
@user-kt2xv8zc4k Жыл бұрын
Conclusiones del comité Cigré TB841 año 2021 sobre el sistema DAC: □ DAC no provee un efectivo y confiable ensayo de tensión resistida. □ DAC no puede ser utilizado como un simple ensayo de tensión resistida comparado a un ensayo de C.A. convencional. □ DAC es generalmente considerado como un método para ensayos en campo de cables envejecidos. □ DAC sobre cables nuevos, nos es eficiente en la búsqueda de defectos de instalación. □ DAC no cumple los requisitos de un tradicional ensayo de comisionamiento. □ DAC no recomendado para cables de 220 KV en adelante. Guide for on-site Diagnostic PD testing of HV Cable Systems (≤5 years) Y AQUI VIENE LO PEOR: según Cigré □ Un equipo DAC, debe alternar rampas de cargas bipolares en DC [primero una (+), luego una carga (-)]. □ NO es recomendable aplicar “N” oscilaciones positivas, y luego “N” oscilaciones negativas. □ Debe limitar su tiempo de carga en DC en un máximo de 5 segundos. (imaginen cargar 300KV en solo 5 Seg…..) Lamentablemente, todos los actuales equipos DAC fueron construidos y vendidos generando una tensión continua de carga unipolar, y bajo un tiempo de carga en DC de hasta 100 s. Responder
@user-kt2xv8zc4k
@user-kt2xv8zc4k Жыл бұрын
(Tiempo de video 40:36) De donde sacó Ud. el dato de que esta permitido valores de hasta 1000pc en cables plásticos, y hasta 3000pc en cables de papel aceite???? La experiencia de quien... (sepa que los cables no son "plásticos" como usted dice; sino todo lo contrario, son termoestables o termofijos que es precisamente lo contrario a termo plástico.