I really just wan to know what the yellow vest makes of good things? ;)
@rickykiste4 ай бұрын
Thanks for the info
@Bob-ed3qi5 ай бұрын
I lay it straight onto a screed floor,I dont have the height to lay insulation board, or it with cause a step into our lounge
@11oct125 ай бұрын
Thanks for sharing. I know this was uploaded a long time ago, but maybe you are the best person to answer my question. So one head of the warming wire is connected to power, but waht about the other head? What is at the end of the warming cable? I got one with cutted both heads and wondering if somehow I can make it work for my office . Thank you
@criticalthinker779 Жыл бұрын
Can't understand a thing you're saying. Buy a wireless mike. Attach the transmitter to your belt and clip the mike onto your shirt. Plug the receiver into your camcorder.
@tsw4437 Жыл бұрын
Hello I am in process of installing water underfloor heating. As part of the project the contractor is also moving the boiler from kichen to garage. My question is when the project completed what kind of certificate and documentation should I get for the underfloor heating installation and for moving the boiler for my future record. Can you please list out what should I get from the company on completion please. Thanks,
@bazf2443 Жыл бұрын
Didn't see what happened to the wire at the other end of the room.
@alkaholic4848 Жыл бұрын
Where can I buy one of these?
@keithalbelli912 Жыл бұрын
Really! A high vis vest in a house!! Guess it’s a high traffic area
@aster7693 Жыл бұрын
Are there any limitations to what kind of carpet/underlay you can have? as I have looked into wet underfloor heating with carpet and have been advised the carpet has to come under 1.8 or 2.0 tog to allow the heat to dissipate, is this the same with electric ufh as well?
@gaborhajdu6826 Жыл бұрын
Hi, Can I ask for a question please? Can I put this ( 15m² Snug Underfloor Heating Mat Length 30000mm Width 500mm ) under 14mm laminate? Thanks for a help! Gabor
@johnturner4400 Жыл бұрын
I’m no expert but I think you need to put levelling compound at 10mm thick over the heating wire first before any floor finish. The 10mm levelling compound dissipates heat evenly.
@joshvedder1613 Жыл бұрын
What gauge wire would you use to connect to the front end termination and how do you tell which is the live and neutral wire? Thanks for the help!
@neile36a2 жыл бұрын
Oh dear why didn’t you use tile adhesive to glue them down not good.
@johnkomosa40892 жыл бұрын
Nice clean work. Retract that utility knife when your not using it. Safety 1st., nice job, mite.
@rodolforojas81602 жыл бұрын
Compa lo instalaste mal el adherible va hacia el piso
@edfast47412 жыл бұрын
Hi there , once all laid and the leveller compound set, Could you use lino flooring rather than tiles?
@firsttraceheating2 жыл бұрын
Hi Ed, Using our 160W/m² electric underfloor heating mats, you certainly can lay lino over the top, providing you first lay at least 10mm flexible self levelling compound. We hope that helps, but if we can offer any more advise, our friendly technical team are always on hand to help. Just give us a call today on 01772 761333. Thanks, The Snug Team.
@eugeniopinto3 жыл бұрын
Why after min 5:55 you insisted don t change the camera from the initial position, denying any chance to see and understand what you have been doing???
@firsttraceheating2 жыл бұрын
Thanks for the feedback Eugenio. We will be producing new instructional videos very soon, with video captured from lots of great angles. Make sure you subscribe to us today to receive notifications when we release new videos. If you need help with an installation on your own project, please don't hesitate in giving us a call, where our friendly technical team would love to help, it's 01772 761333. Thanks, The Snug Team.
@polaceacP3 жыл бұрын
Hello, what kind of bed is suitable for this type of heating, should it have legs?
@matthewellison58143 жыл бұрын
Is it exactly the same for floor boards?
@mirajabdullah3 жыл бұрын
Hi. So is it not possible at all to screed/tile directly onto the electric floor mat?
@marijussilickas51783 жыл бұрын
spread adhesive under mat, lay mat, spread adhesive on tile. best result
@naranjasparks511112 күн бұрын
yes you can. i did and it turned out fine
@andreaprifti92823 жыл бұрын
Great video much appeared Can those boards be used in concrete floor?
@firsttraceheating3 жыл бұрын
Hi Andrea, Thanks for watching our video, we trust you found it helpful. Our boards are absolutely fine to be used on either concrete or wooden floors, so you won't have a problem. If you are using the boards on a concrete floor, we would recommend fixing the boards down with flexible tile adhesive. Feel free to give us a call on 01772 761333 for more advice or if you have any questions about choosing the right underfloor heating solution for your project. Many thanks, The Snug Team.
@davidhale80343 жыл бұрын
Who is the levelling compound made by?
@firsttraceheating3 жыл бұрын
Hi David, Our levelling compound is made by Rocatex. The fibre-reinforced self-levelling compound gives heating mats and cables extra protection - ideal before you begin tiling the floors on a project. Why don't you give us a call on 01772 761333 to discuss your project? We would love to hear from you.
@a705fay4 жыл бұрын
you didn't prime the concrete floor I thought it was essential to prime the floor?
@bobrussell20914 жыл бұрын
Why is my cable only heating half the length on a thermostat
@johnkomosa40892 жыл бұрын
What is your application voltage? 120 vac? or 24vac control? Self sensing, don't forget that. Regulated along the run.
@markleewilson66114 жыл бұрын
A trowel using for grout 😂😂😂
@dazd240 Жыл бұрын
Does it matter, it did the job!
@UrbanPlumbers4 жыл бұрын
have you just laid the insulation loose over the floor?
@shirleycarter92104 жыл бұрын
Have you listened to the video ?
@UrbanPlumbers4 жыл бұрын
@@shirleycarter9210 no, too long to listen to.
@jamiemurphy34044 жыл бұрын
How are you sealing the joints when the tape your using is full of holes
@joenest21224 жыл бұрын
It appears you screwed directly into a concrete floor. Is that possible without drilling in Rawl plugs first?
@firsttraceheating4 жыл бұрын
Hi Joe These boards were put down straight onto a wood base, if you are putting them on a concrete base you would need to drill and rawl plug.
@meentaalmaan3 жыл бұрын
@@firsttraceheating or use tile adhesive?
@j4miee4 жыл бұрын
Really helpful mate thank you
@mujahidjaigadkar73755 жыл бұрын
Do you want underfloor Heating & electric underfloor Heating ? (Loop layout in 24 Hours).Please contact [email protected]
@garystinten93395 жыл бұрын
would using aerogel matting insulation be OK instead of using these insulation tiles?
@patrickjay64345 жыл бұрын
Hi, what type of insulation boards are these please? They look nice and light which is what I'm looking for
@firsttraceheating5 жыл бұрын
Hi Patrick, they are a thermal construction board that we (snug) sell and are available and any electrical or wholesaler. Our part codes are Thermboard-6 for 6mm thick and Thermboard-10 for 10mm thick.
@patrickjay64345 жыл бұрын
@@firsttraceheating thank you
@rupertzammit3 жыл бұрын
@@firsttraceheating Are these thermal boards resistent to high temperatures of the electric mat?
@tomdewsbury94565 жыл бұрын
I have had electric underfloor heating fitted -- sort of --to my conservatery .. they have used very thin insulation matting on top of concreat then put the vinyl floor boards on top and i dont think they have screed the heating mat because the floor is wavey ie not flat .. my builder says its a floating floor .. I think its a total balls up ..
@firsttraceheating5 жыл бұрын
Hi Tom, Happy to give advise on your installation. If you would like to call us we'll go through things in detail with you.
@nohalo4me5555 жыл бұрын
Is it necessary to apply heat under the vanity?
@firsttraceheating5 жыл бұрын
No you don't want to install under any units, you can install up to them but not under them.
@nwlady18445 жыл бұрын
Is your product (heat trace cable and kits) available for purchase in the United States? thank you
@vaibhavglasgow5 жыл бұрын
Hi can this be used for carpets too? Also can I put underlay on top of the mesh when putting carpet?
@hamidbazmi79485 жыл бұрын
Nice video. But I would like to know more about electrical connections. Should it be part of a ring or should have a separate circuit? Should be on RCD? What size cable do you use? Thanks
@firsttraceheating5 жыл бұрын
Thanks for your comment, it can be part of the ring main but we would recommend that you install a fused spur and then connect that to the controller. That way you have local isolation. An RCD should be on the circuit somewhere, whether that is by the board or an RCD fused spur. If it is coming off a ring main you would want to use 2.5mm2.
@hamidbazmi79485 жыл бұрын
@@firsttraceheating Thanks for explanation. Is it just specifically used in bathrooms or they can be used all over the house?
@firsttraceheating5 жыл бұрын
@@hamidbazmi7948 It can be used in any room in the house. The mat in the video is designed specifically for under tiles, if you have other floor finishes then we mats to suit as well.
@hamidbazmi79485 жыл бұрын
@@firsttraceheating Thanks again. I guess with 100_300W it would very cheap and efficient to run it.
@hamidbazmi79485 жыл бұрын
If we run underheating system throughout the house, do we still need radiator?
@thomasmitchell82965 жыл бұрын
do you need to prime before screed?
@firsttraceheating5 жыл бұрын
It all depends on how dusty the surface is. the primer is there to absorb the dust so that the levelling compound or tile adhesive can get a better bond to the subfloor.
@martinjames17786 жыл бұрын
Cannot see the detail of his work as he moves out of camera shot! Clueless!
@jamesboobtube6 жыл бұрын
really useful video, thanks. Question: i have seen insulation floated over chipboard, as you have done, also insulation glued down using tile adhesive. I'm reluctant to glue down as per the instructions for the INSOMAX board, as i don't really think it adds strength but also adds a lot of moisture, which will have to find its way out somehow. Any thoughts?
@firsttraceheating6 жыл бұрын
Hi James, The boards want to be fixed down somehow, in the video we used screws and washers as the subfloor was wood. Fixing with boards using a tile adhesive is also ok as long as its flexible tile adhesive.
@kevinhandley6 жыл бұрын
Would you recommend testing that the circuit works before putting the compound down?
@firsttraceheating6 жыл бұрын
Yes you should test the mat at 3 stages, firstly when its on the roll, then once the mat has been aid and then finally after you have tiled. You should get the same readings on all 3.
@ArtisanTony6 жыл бұрын
If you mix the leveling compound correctly it is self leveling.
@UrbanPlumbers4 жыл бұрын
not true I am afraid. You need to spread it from the lowest place.
@MrTurnbull1517 жыл бұрын
What happens if you do not use the insulation boards underneath? Assuming heating is laid on top of fibre cement and then sand & cement screed & tiles on top? Would you lose much heat going down rather than up?
@firsttraceheating7 жыл бұрын
As a rule of thumb 30% of your heat will be lost when insulation boards are not used.
@MrTurnbull1517 жыл бұрын
Thank you. Is there any alternative to insulation boards? These would raise the floor level of our retro fit in ensuite
@firsttraceheating7 жыл бұрын
The system will still work fine without insulation boards. The boards just make your running costs lower and your heat up times quicker. The boards come in both 6mm and 10mm. Unfortunately there isn't a thinner product that will do same job as the insulation board.
@garystinten93395 жыл бұрын
firsttraceheating aerogel Matting? in sizes of 1mm 5mm and 10mm thicknesses
@EASYTIGER107 жыл бұрын
Has anyone ever tried developing a fully integrated floor tile/heating/insulation system made up of tiles with electrical connections at the edges which you lay more or less like normal floor tiles. Could it work?
@firsttraceheating7 жыл бұрын
Not that I know of, the issue would be the number of variations in tiles and also the floor heating cable has to be in one continuous length so you would need 15 different variations of the same tile to suit different room sizes. Times that by 200 different tiles a shop may have and the cost would make it not viable.
@fardellp7 жыл бұрын
Outstanding video - head and shoulders above the others - and NO SOFT PIANO MUSIC! (brilliant). I presume you can dispense with the levelling compound and place your tile cement directly on the heating mat?
@firsttraceheating7 жыл бұрын
Thanks for the comments! Yes you can place tile adhesive directly on top of the floor heating. The levelling compound is only an option as it helps protect the cable from being damaged during tiling.
@michellearmstrong45957 жыл бұрын
could I put the insulation boards on top of my laminate flooring or will it be best to take laminate up and put insulation boards on the concrete floor
@firsttraceheating7 жыл бұрын
Hi Michael, We would recommend that you remove the laminate unless you would be placing another laminate over the top. As the wood will move you really don't want to be leaving that down if you are going to be putting a screed or tiles over the top.
@TryThinkingAboutIt7 жыл бұрын
Not easy explaining things is it? How do you make sure it fits the room if the room is not a standard shape? Make it into loose cables. How? And then you don't show them. Being an expert at making something doesn't mean you are expert at explaining how to use your product
@firsttraceheating7 жыл бұрын
Hi Ian, Are you struggling with measuring you room or with the selection of the mat size? The easiest way to work out your free space is to get your full room size then minus off your units i.e. bath, toilet, sink, shower. Then once you have this measurement deduct 10% and go to the next mat size down. If your free space is 10.5m2 You would want a 9m2 mat. If in doubt you always go for a smaller mat than bigger mat as you can not cut the cable. I hope this helps, any more questions please let us know and we'll be happy to help.
@colinmcguiness7 жыл бұрын
Hi. Great video thanks. Would you run the levelling compound over the areas marked for sink/toilet etc?
@firsttraceheating7 жыл бұрын
Yes you would run the levelling compound right up to the soil pipe as the tiler will be tiling to that point. Where ever you have tiles you want the subfloor (floor heated or not) to be an even height otherwise the tiler will need to build up the floor with adhesive which is more labour intensive.
@raysmith3017 жыл бұрын
firsttraceheating does the power supply go to a low level spur ie socket height? Or directly to the controller?
@firsttraceheating7 жыл бұрын
firsttraceheating 1 second ago Ideally you want the power to come from the mains, to a fused spur then to the controller. That way if you ever have to isolate the underfloor heating you can without isolating the whole ring main.