Пікірлер
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 5 сағат бұрын
Hello sir number nhi diya apne
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 5 сағат бұрын
Sir rispons nhi diya sir please help me sir
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 2 күн бұрын
Love you sir
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 2 күн бұрын
Contact me
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 2 күн бұрын
Nice 👍
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 3 күн бұрын
Job location sir
@Electrical_Supervisor
@Electrical_Supervisor 3 күн бұрын
Ambernath, Maharashtra, India
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 3 күн бұрын
@@Electrical_Supervisor ok sir a jaye ge ap apna number send kar dijiye sir
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 3 күн бұрын
Sir job chahiye
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 3 күн бұрын
Electrical Engineer
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 3 күн бұрын
Job location
@Electrical_Supervisor
@Electrical_Supervisor 3 күн бұрын
Ambernath, Maharashtra
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 4 күн бұрын
Sir job lgwa do diploma in Electrical Engineering
@Electrical_Supervisor
@Electrical_Supervisor 3 күн бұрын
Kitni salary expect kar rahe ho ?
@Electrical_Supervisor
@Electrical_Supervisor 3 күн бұрын
Aur work experience kitna hai ?
@RavindraKumar-lc5vf
@RavindraKumar-lc5vf 4 күн бұрын
Diploma in Electrical Engineering
@kumarReddy1894-n1v
@kumarReddy1894-n1v 5 күн бұрын
Cable 400 sq mm 3.5 cor
@Electrical_Supervisor
@Electrical_Supervisor 5 күн бұрын
We use upto 300 sqmm 3.5C
@kumarReddy1894-n1v
@kumarReddy1894-n1v 5 күн бұрын
400 sq mm cable 3.5 cor full Amps ???
@ShahKhan-h4c
@ShahKhan-h4c 7 күн бұрын
How about electrical engineer
@Electrical_Supervisor
@Electrical_Supervisor 6 күн бұрын
Electrical supervisor work under electrical engineer. And electricians work under electrical supervisor
@haseebali499
@haseebali499 Ай бұрын
Gland size used for 300 mm2 ?
@Electrical_Supervisor
@Electrical_Supervisor Ай бұрын
63 mm
@adilsaik
@adilsaik 5 күн бұрын
75
@kidsentertainment6538
@kidsentertainment6538 2 ай бұрын
Es penal ka kiya naam hai
@saeedfatma3588
@saeedfatma3588 2 ай бұрын
Thanks. Sar. ji
@mdmamunrrashid-nm9jb
@mdmamunrrashid-nm9jb 2 ай бұрын
kidarka video a
@Electrical_Supervisor
@Electrical_Supervisor 2 ай бұрын
Ultratech
@RambahadurChaudhary-r8j
@RambahadurChaudhary-r8j 3 ай бұрын
Alag Alagse connection dekhateto bahut achxa hoga😅😅
@Electrical_Supervisor
@Electrical_Supervisor 3 ай бұрын
Ok
@ShahKhan-h4c
@ShahKhan-h4c 4 ай бұрын
Hellooo sir how can we learn it properly step by step
@Electrical_Supervisor
@Electrical_Supervisor 4 ай бұрын
For theory, look at the Contactor diagram and then go to the controlling panel and do the practical with an experienced person.
@abidali.6873
@abidali.6873 4 ай бұрын
Good luck
@shaikhalamkhan1450
@shaikhalamkhan1450 4 ай бұрын
иι¢є
@RiteshMourya3690
@RiteshMourya3690 5 ай бұрын
Right ✅️ ↔️ 👉 🔛 ➡️
@ashokkumar-mk5uo
@ashokkumar-mk5uo 5 ай бұрын
How calculate that cable size
@Electrical_Supervisor
@Electrical_Supervisor 5 ай бұрын
Method -1 We talk about 3 phase, heavy load, and Aluminium cable. According to Ampere load = near by available cable size Example-1, 60A load, here available cable near below 60 are 50 sqmm and 35 sqmm If the cable length below 100 mtrs we use 35 sqmm If the cable length above 100 mtrs we use 50 sqmm cable. Example-2, 300A load, here available cable near 300 are 300 sqmm and 240 sqmm If the cable length below 100 mtrs we use 240 sqmm cable and if the cable length above 100 mtrs we use 300 sqmm cable. You may use 2 run of 150 sqmm cable against 300 sqmm single cable. Similarly for 1000A load We use 3 run of 300 sqmm cable For 1600A load we use 5 run of 300 sqmm cable. For Copper cable multiply the Ampere by 1.2 and use above method. Method -2 For below 30A load and copper cable ...we just use Below 1KW load - 1.5 sqmm 2-3 KW load - 2.5 sqmm 3-5 KW load - 4 sqmm 5-9 KW load - 6 sqmm 9-12 KW load - 10 sqmm 12-16 KW load - 16 sqmm 16-25 KW load - 25 sqmm For aluminium cable Divide the load(KW) by 1.2 and use above method ☝️
@Electrical_Supervisor
@Electrical_Supervisor 5 ай бұрын
If you want to use formula then I recommend use formula Power in KW(Load) = Volt x Current x power factor Example 3 phase load given 8 KW So, 8 KW = 8000W = 415(volt) x I(current) x 0.8 (pf) You Get I (current ) = 8000/(415*0.8) = 24A Now for safety I = 24 x 1.5 or 2 = 36 to 48 A Now search on google current capacity of Cu cable If you found 6 sqmm cable capacity = 33 A 10 sqmm cable capacity= 45 A And you calculate your current capacity= 36A to 48A According to your calculation 10 sqmm cable better for safety but you may use 6 sqmm cable too.
@priyanshusingh6512
@priyanshusingh6512 6 ай бұрын
Apna number btao Bhai....
@Electrical_Supervisor
@Electrical_Supervisor 6 ай бұрын
Number kis liye chahiye bhai
@Electrical_Supervisor
@Electrical_Supervisor 7 ай бұрын
Full video link kzbin.info/www/bejne/rGilYaWKmrKprpY
@shaqeelquraishi2407
@shaqeelquraishi2407 7 ай бұрын
Schematic diagram per bhi video banao
@Electrical_Supervisor
@Electrical_Supervisor 7 ай бұрын
InshAllah jald hi banaunga
@MRIQBAL-pd1dp
@MRIQBAL-pd1dp 8 ай бұрын
Pagol naki?? Ki video te ki music lagaise
@Electrical_Supervisor
@Electrical_Supervisor 8 ай бұрын
You're right but this is vocal sound... next time i take care of it....thank you ❤
@RakeshYadav-p9w3f
@RakeshYadav-p9w3f 8 ай бұрын
Super
@Electrical_Supervisor
@Electrical_Supervisor 8 ай бұрын
Thanks ❤️
@Electrical_Supervisor
@Electrical_Supervisor 8 ай бұрын
DG panel and Cable termination video link kzbin.info/www/bejne/hHnKfIelo8uJjtksi=yd-L-BsLrQz7u83g
@user-yh4kl3hx2o
@user-yh4kl3hx2o 9 ай бұрын
Great work 🤲🏽
@Electrical_Supervisor
@Electrical_Supervisor 9 ай бұрын
Thank you 🙌
@Mobeenwairman
@Mobeenwairman 10 ай бұрын
Saprort कर रहे aap ko mai bhi ek Electrican hun 95k subscriber mai mere subscribe kar diya