Пікірлер
@bobby_hill8357
@bobby_hill8357 14 күн бұрын
I cant get mine to run on propane. Same model, same directions followed. Its frustrating.
@pchamutt
@pchamutt Ай бұрын
Me podrian informar cuantos kilogramos tiene de peso ?
@rayseguin8933
@rayseguin8933 3 ай бұрын
Great video. What's the difference between the TO7571 and the TO7573 Firman's ??
@AB-mf4lj
@AB-mf4lj 2 ай бұрын
73 has a CO monitor
@jerseyteacir
@jerseyteacir 4 ай бұрын
This is very interesting, is there any way you can share your wiring diagram and part list. Amazing work
@alotaku
@alotaku 6 ай бұрын
Can I get a parts list for this? As in controller module, arduino module etc? Also I’d like to add a temperature control function as in freezer temp for auto start. I know OF arduino but not HOW to arduino. Any resource would be appreciated . Thanks
@eye8pho29
@eye8pho29 6 ай бұрын
I seen videos that these things just in certain places. Is there a way to prime piant or something kind of prevention spray we can use to protect from rusting? Maybe use a spray to cover when you first bought the unit?
@chrischoate274
@chrischoate274 6 ай бұрын
This system is currently operating off 120 volt but can one be designed to operate the same in an area where there is no access to electricity
@user-tq5wc1ti8f
@user-tq5wc1ti8f 6 ай бұрын
Can you share how you connected everything? How did you connect the main power(Grid Power) to the controller?
@jasonJSilva
@jasonJSilva 6 ай бұрын
Can you make a simple unit for only remote start and stop.. i dont need anything else. Id just like to usea remote to turn my firman trifuel on and off from inside my house as its super cold here in canada in the winter.
@orfatron
@orfatron 7 ай бұрын
Ive watched allot of reveiews that firman generators rust easily . Frame rusts and fittings rust. But hey for the price point i think having multiple fuel options is amazing . Hope the motors last .
@BlaacHollow
@BlaacHollow 7 ай бұрын
I just bought one brand new with a brand new propane tank. I did everything but its not starting. You can hear it try to start but it;s not kicking in. Did I miss something? Yes I put oil in as well. cold battery?
@douglundy5755
@douglundy5755 7 ай бұрын
okay this isnt ready for sharing, youre designing and chatting about your whole life history and great to see this but share when its put together, willya! This is development work. Not presentation quality. Thanks again. We need this. Looking forward. Actually there should be a choke setup possible where the running lets the choke off and no control is needed for the choke. Something centrifugal or exhaust powered..Then we just need a remote close the circuit control.
@douglundy5755
@douglundy5755 7 ай бұрын
volume is low, will use headphones. I also want to convert mine and great to see your work.
@Gurusi
@Gurusi 8 ай бұрын
A parts list or the ability to buy a kit from you would be great! Your videos are the most detailed on utube for solving Firmans auto start hurdles. going in and out to start/stop it daily in Canada sucks!
@xman4328
@xman4328 10 ай бұрын
Grossly over complicated... 90% of that is not necessary..
@wesw281
@wesw281 10 ай бұрын
I have the same ge. Do you make these kits?
@fancynancyrie
@fancynancyrie 10 ай бұрын
Fantastic! Very interested in this system. Have you prepared a schematic / materials list for it?
@jaym48
@jaym48 10 ай бұрын
So the LP bypasses the gasoline/carberator system for all TriFuel systems? Do you just turn the gasoline fuel tank line to off....do not worry what setting the carbetator is on and simply plug in the LP /NG and start? Is the rpm the same going back and forth on fuels or is the system calibrated by manufacturer?
@samueladitya1729
@samueladitya1729 10 ай бұрын
Great work. Please consider for hybrid system for next project with battery, inverter, and charger. so the generator run at its peak efficiency to charge the battery and cycling on and off between battery charge level.
@eastmanresearch3143
@eastmanresearch3143 10 ай бұрын
my lp generac choke goes back and forth at least twice a second until it starts up. I have a firman too. Looking at doing a 2 wire start on it for charging 48v battery banks when grid is down.
@Test-uy2wz
@Test-uy2wz 9 ай бұрын
You figure out how to successfully wire it into your All in One? Going to try and do the same, but with a dry start auto start the Mpp 2424lv is pre set up for with a auto transfer switch apparently already built in. Idk anything about it needing to mess with the choke if I can wire it or if that gets bypassed, but we have to see. Let me know what you conclude? Thanks.
@bimmerboard
@bimmerboard 11 ай бұрын
I’d like to buy that remote start kit from you. Where can I get it?
@MrSilvervw
@MrSilvervw 11 ай бұрын
Fantastic content 👌 👏 👍
@marcelinanoss8825
@marcelinanoss8825 11 ай бұрын
can you share with us how long you can run this generator wqith a full tank of LNG?
@waltkuiland9341
@waltkuiland9341 11 ай бұрын
Thank you for this video. It was a great help. Just bought this generator and this was great!
@deflamrek
@deflamrek 11 ай бұрын
A tank of gas can go 12 to 15 hours on light load. 8 hours on heavy load. A tank of propane can go 10 to 12 hours on light load and 6 hours on heavy load
@nazsnidanko
@nazsnidanko Жыл бұрын
Good job, very interested and subscribed.
@stephanesavoie7206
@stephanesavoie7206 Жыл бұрын
Are you selling any kits . ?
@margaritojrmayola326
@margaritojrmayola326 Жыл бұрын
Great Clip! Thanks for sharing. Can i get the specs of the add-on accessories?
@davidglover2023
@davidglover2023 Жыл бұрын
Flashing red light, what’s that mean? Oil and gas are checked. Choke is set. Does not stay started tho.
@walkindesigns7288
@walkindesigns7288 Жыл бұрын
Turn the knob in front from the off position to the left or right depending on the type of fuel being used. If you leave it in the off position, the red light blinks and it will start for a few seconds and then shut down.
@thompsonchidi2618
@thompsonchidi2618 Жыл бұрын
I love it but please can I have the wiring diagram
@alexanderjeffers7438
@alexanderjeffers7438 Жыл бұрын
Did you ever finish the generator. I would like to check it out! I am about to do the same.
@fernandogarza1936
@fernandogarza1936 Жыл бұрын
Like your set up! Do you sell a kit?
@rogerschroeder4020
@rogerschroeder4020 Жыл бұрын
Have you had any communications with FIRMAN about this product. I recently was advised by FIRMAN that extending the exhaust pipe or installing the Generator in an enclosure would VOID my warranty. Any advise on this?
@jonsgarage3859
@jonsgarage3859 Жыл бұрын
I believe that this modification will void your warranty.
@tennesseenola
@tennesseenola Жыл бұрын
I also have a T07571, but mine is hooked to Natural Gas. I have found that mine is a bit tricky to get going, with either gasoline, propane or Natural Gas. I have to "play" with the choke and it takes a few attempts to make it happen. Can you suggest a solution?
@brianmalubag9387
@brianmalubag9387 9 ай бұрын
I saw something similar issue like your and the fix on that video is to turn on the propane slowly...
@pernell4351
@pernell4351 Жыл бұрын
Where did you get the control panel for auto start
@jonsgarage3859
@jonsgarage3859 Жыл бұрын
Online, aliexpress in my case, amazon also sells generator control panels.
@mattbkarr
@mattbkarr Жыл бұрын
Running that with the covers loose is a hazard.
@jonsgarage3859
@jonsgarage3859 Жыл бұрын
No worries, the covers were off for testing purposes in a controlled environment.
@zarethshahar433
@zarethshahar433 Жыл бұрын
Thanks for your video it's very helpful. Thanks again
@hondakila1
@hondakila1 Жыл бұрын
Good work bro am trying to do the same thing is it possible for u to send me the products u used and a wiring diagram thanks
@danroberts9050
@danroberts9050 Жыл бұрын
What is the difference between the T07571 and T07573? I have the T07573
@jonsgarage3859
@jonsgarage3859 Жыл бұрын
Carbon dioxide level alarm and auto shut down and added weather resistance
@VeronicaGutierrez-gu6er
@VeronicaGutierrez-gu6er Жыл бұрын
Can you help with the auto start I need and the diagram to do for my generator please
@ricardoflot2787
@ricardoflot2787 Жыл бұрын
There's one here where I work. I tried to get it going the other day but, was unsuccessful. It'll turn on but, won't crank. I didn't bother using the pull crank but, can I use that instead?
@a.rod876
@a.rod876 19 күн бұрын
U can
@ricardoflot2787
@ricardoflot2787 18 күн бұрын
@@a.rod876 okay.
@figbig1338
@figbig1338 Жыл бұрын
Привет дружище спасибо большое за информацию. Скажи пожалуйста ты доволен этим генератором? Ещё вопрос есть возможность настроить его на 50 герц!? Не могу найти нигде информацию!? Спасибо
@davepetro5676
@davepetro5676 Жыл бұрын
If I was you I make in a box with magnets that cling to the frame. And make female click connect on the box male that attaches to generator battery. Did you connected to a trip switch on the side can’t tell I’m a Electrician 2 let me know if you selling a kit. I used a contractor monitor though a k contractor . Or maybe a Napco relay board. You can control up to 9 relays at once. Great video. The internet sell Napco relay boards way to much buy at your local alarm supply way cheaper.
@deepsub6
@deepsub6 Жыл бұрын
Just a mess of components on the ground. Nothing about installation and final integration
@hammerdriver5950
@hammerdriver5950 Жыл бұрын
Damn your good !!
@bujin5455
@bujin5455 Жыл бұрын
Nice video. Did you ever figure out your automatic start setup?
@nwmi493
@nwmi493 Жыл бұрын
thought I was the only one geeking out lol. I have the HGN4020N panel, likely the same unit as yours. Controlling a WEN 8750 inverter generator out in a shed. Mounted the panel in a hobby box. Did have to install a timer relay to shut choke off at first but I dont need it anymore. Originally I was using aux 1 output (pin 7) set as fuel pump to energize the choke relay but deleted it an now running the choke off the crank terminal. But did have to install toggle switch to turn off the choke for hot starts. Are you using any other sensors on the air cooled motor? Cylinder head temp? Tachometer pickup? and CT's to take advantage of the current read out on the display? I thought I'd go one step further and installing a reed style fuel level sensor to tell me fuel level in the house . I am impressed with the smartgen panel. i'ts pretty powerful.
@Jipoxy
@Jipoxy Жыл бұрын
Good to note:. Noticed he put in a delay on timer when power is lost. This is important so if power flicker on and off the gen doesn't try to start. Also good to set up an off delay timer for the reverse of this to ensure the power has actually returned. Just be sure you don't back feed power 😝
@Jipoxy
@Jipoxy Жыл бұрын
I have the same generator with a Honeywell auto transfer switch, SR2B121BD SCHNEIDER ELECTRIC controller and the same door lock actuator. Do you use reverse power output to the actuator to make it dual acting ? My actuators don't spring return..
@johannastardust
@johannastardust Жыл бұрын
*100% best **Generater.Systems** I have used. A test for hurricane prep here in Louisiana: three AC units, 5000, 5000 & 8000, 3 fridges, 2 device power setups, 4 flat screens....AND I had 40% of the power meter to spare.*
@Alloyaha
@Alloyaha Жыл бұрын
NO! That will cause all kinds of problems. You need a transfer panel if you want this to power your whole home. Best to get an electrician install one correctly.