Пікірлер
@tipsy09
@tipsy09 14 минут бұрын
It’s good?
@universaldonor3100
@universaldonor3100 2 күн бұрын
why can't the posters who comment on videos be able to vote idiots like this off the island?
@dxllysinn_xoxo
@dxllysinn_xoxo 26 күн бұрын
First
@r8rO
@r8rO Ай бұрын
Uh uh 😂
@ChandanPal-qx2de
@ChandanPal-qx2de Ай бұрын
Thanks man
@CHIBA280CRV
@CHIBA280CRV Ай бұрын
What did he say he replaced , I can’t understand???? Doesn’t even show any parts?anyone
@ahmedsawni862
@ahmedsawni862 2 ай бұрын
Thank you so much for sharing the knowledge 👍
@WibbyKDX
@WibbyKDX 3 ай бұрын
Sweet video dude. Very informative
@donaldturner1360
@donaldturner1360 3 ай бұрын
Does it work with coil cleaner?
@JoseRodriguez-kx9gz
@JoseRodriguez-kx9gz 3 ай бұрын
Where do you get the probes. Can the hoses alone be used?
@JoseRodriguez-kx9gz
@JoseRodriguez-kx9gz 3 ай бұрын
I have that 510 but not the probes.
@JoseRodriguez-kx9gz
@JoseRodriguez-kx9gz 3 ай бұрын
Can you do it without the probes. ?
@bills6946
@bills6946 3 ай бұрын
It is not a 2 phase compressor. It is a single phase compressor at 240 volts. Both hot legs are center tapped in the distribution transformer as a delta configuration to create the neutral for 240 volts, hot to neutral is 120 volts. If it were derived from a wye configuration, it would be 120/208 volts the common from both legs is the neutral
@KINGPAFA
@KINGPAFA 3 ай бұрын
??? It is a 3 phase 575 v Scroll compressor!
@steveway7981
@steveway7981 4 ай бұрын
Dude, really? Do you got to have that f****** thing beeping
@JohnLennon-yg4ut
@JohnLennon-yg4ut 4 ай бұрын
unwatchable. every other word is “uh” *heavy breathing “ uhhh” more heavy breathing. You sound like a Neanderthal
@deddie4645
@deddie4645 5 ай бұрын
Would one of you you 2 people at least give the same information you tested the same voltage or test it at double the voltage ratedV
@kevinortiz7332
@kevinortiz7332 5 ай бұрын
I would be very grateful if someone could tell me if they have or should buy an air conditioner.
@kevinortiz7332
@kevinortiz7332 5 ай бұрын
I'm looking for how to make it turn on if it has one. or not?
@kevinortiz7332
@kevinortiz7332 5 ай бұрын
Does this system have cold air or not?
@calebcrockett1085
@calebcrockett1085 5 ай бұрын
Hey thanks for making this video, been doing HVAC for 3 years but moved over to installs to help them out within the last few months. Currently all my tools are just thrown in a 5 gallon bucket so you definitely gave me some ideas!
@chrishanse100
@chrishanse100 5 ай бұрын
Useless
@tS-sn7jt
@tS-sn7jt 5 ай бұрын
Useless video
@Freonleon
@Freonleon 6 ай бұрын
Copeland bulletin When using megohmeters to evaluate the motor insulation of compressors, it is important to understand that they should not be used as one would a volt-ohm meter. A single megohmeter reading gives little insight into the condition of a motor’s insulation. Megohmeters are best used as a part of a regular maintenance program to monitor trends (over several months). For example, one might record a megohm value and compare it to a previous reading. If subsequent readings show a trend of lower and lower values, then corrective action (such as system clean up) should be taken. Emerson does not incorporate the megohmeter into any of its quality checks. All Copeland® compressors must pass U.L. required tests using hi-potential current leakage testers (“hi-pot”). Studies performed by Emerson have found that compressors with megohmeter readings as low as 0.5 megohms still pass the hi-pot. There are many factors that affect megohm readings including contaminated refrigerant, oil level, refrigerant in oil and current leakage through electrical fusites or terminal plates. © 2010 Emerson Climate Technologies Printed in the U.S.A. Any external electrical components connected to the compressor terminals also affect megohm readings. Wires, contactors and relays all leak current and will decrease compressor megohmeter readings if not disconnected. As mentioned earlier a single megohm reading cannot be used to condemn a compressor since many other factors are involved. However, limits can be placed on megohm values that dictate action be taken. Emerson has found that these limits are related to the rated voltage of the compressor. Megohm values equal to or greater than 1000 ohms per volt are probably acceptable. For example, a 460 volt compressor might show a megohm reading of 460,000 ohms or 0.46 megohm. Compressors with rated voltages of 208 to 230 volts would then be operable at megohm values of 0.208 to 0.230 megohms; for simplicity, Emerson has set the limit at 0.5 megohms before a compressor is condemned. Figure 1 shows the required procedure for checking compressors with a megohmeter. New compressors that have never been installed will not need any system clean-up procedures so long as the megohm reading is above 0.5. A baseline reading must be established for comparison purposes and since this is its first
@bailielaland6555
@bailielaland6555 8 ай бұрын
🔥 'PromoSM'
@pacospete4299
@pacospete4299 9 ай бұрын
so i'm seeing folks install these mini split systems ans coiling the access lines next to the outside unit .... is this a problem ?
@WireWeHere
@WireWeHere 9 ай бұрын
1990 John Wood NG-HWHT to 2007. 2007 John Wood NG-HWHT to 2024 2024 John Wood NG-HWHT to 2041ish? Flushed every 6 months and always equipped with an expansion tank. Only outlasted by our cats, Diane 24 and her sister Maryanne 26, Figo 23, and his sister Ninha is still kicking at 24 years of beds, dishes and toys washed only with water heated by John Wood.
@SupremeRuleroftheWorld
@SupremeRuleroftheWorld 9 ай бұрын
so, technically a third of that compressor is still good. put it back in and send it!
@gyver471
@gyver471 9 ай бұрын
I thought these had low water cut off built in.
@evezford
@evezford 10 ай бұрын
This is called “No Heat Call” yet it didn’t mention that at all!
@Alienspecies635
@Alienspecies635 Ай бұрын
when the damper doesnt open the boiler wont turn on that means theres no heat, aka no heat call. sequence of operations is the damper opens firsts, luckily you can bypass the damper by flpping the switch as he did and now the heat works.
@Electric-Air-Service
@Electric-Air-Service 11 ай бұрын
Very good video..
@cowoganteng3776
@cowoganteng3776 Жыл бұрын
👍👍👍🙏🙏🙏🙏🙏
@williamwalker-bm5mz
@williamwalker-bm5mz Жыл бұрын
The video was useless
@KINGPAFA
@KINGPAFA Жыл бұрын
LOL!
@saner6888
@saner6888 Жыл бұрын
Where is the filter on this unit and is there just one? I believe this is the unit I had installed TY
@TheLandlordPicker
@TheLandlordPicker Жыл бұрын
What did you do to fix it?????
@denisvandecker8275
@denisvandecker8275 Жыл бұрын
That was a waste of time video. People are expecting How To not just hey look I fixed it.
@bhushank7420
@bhushank7420 Жыл бұрын
Just wondering if you’ll be kind to help me with Raypak H3-514 boiler.
@tcmazz
@tcmazz Жыл бұрын
Yeap what was the point of the video? I agree with everyone useless
@djluck95
@djluck95 Жыл бұрын
If you were a real Samsung technician you would have used the Samsungs diagnostic cable to say 100% that the board is bad, not just guessing ... "another well done job"
@KINGPAFA
@KINGPAFA Жыл бұрын
Lmho.
@robertplas3947
@robertplas3947 Жыл бұрын
Please re-title your video to my Raypak pool heater was fix. Awful title and very misleading.
@arx9z
@arx9z Жыл бұрын
just found your channel and love the videos. Where do you get most of your hydronic parts in Toronto?
@tS-sn7jt
@tS-sn7jt Жыл бұрын
Hey what’s the point of your video
@dfx7105
@dfx7105 Жыл бұрын
We've all been in the bushes
@dougthegreat1808
@dougthegreat1808 Жыл бұрын
USELESS
@partshnc
@partshnc Жыл бұрын
Every stage in the installation procedure has been broken down into clear, thorough explanations that are simple to follow. We provide quality Raypack pool heater spare parts, in case anyone is in need of them.
@BlacHaze78
@BlacHaze78 Жыл бұрын
You’re video is terrible
@jasonfoster9118
@jasonfoster9118 Жыл бұрын
I'd like to make a correction. Anything less than 1 Megaohm is considered a failure, while in reality, I've seen motors run with less than that. 50 Megaohms is a very good reading.
@Michelle-lk6lu
@Michelle-lk6lu Жыл бұрын
HOW do you light the pilot??
@xigam1975
@xigam1975 Жыл бұрын
That's what I'd like to know.. where do you put the flame to light the pilot..
@timothymcmahon1507
@timothymcmahon1507 Жыл бұрын
@@xigam1975at the end of the metal tube
@posplaytime801
@posplaytime801 Жыл бұрын
Why post a video like this??
@wtp5
@wtp5 Жыл бұрын
This is useless
@herbertgarcia4297
@herbertgarcia4297 Жыл бұрын
How did you fix it????
@globalheatingcooling
@globalheatingcooling Жыл бұрын
Changed The Powerpile.
@omarbuchanan6283
@omarbuchanan6283 Жыл бұрын
I have a Raypak 406A which is not clicking. What is a "powerpile"
@natemiller7841
@natemiller7841 5 ай бұрын
​@@omarbuchanan6283same here, did you figure it out ?
@Victor-r3m7e
@Victor-r3m7e 4 ай бұрын
Mine clicks but doesn't seem like it's running?
@chhuangaralte2078
@chhuangaralte2078 Жыл бұрын
Who wa t to swap Fluke 87 V MAX with Fluke 1507