Dear brother, please tell me,To reduce the resistance of water, do we add salt or something else and in what quantity?
@bishantkumar12589Күн бұрын
Yes salt is added to increase conductivity since they contain free electrons. Quantity will depend on application
@kuldeepdhiman7570Күн бұрын
@@bishantkumar12589 bro, ph full form?
@manishachangotra44262 күн бұрын
yeh koi pukhta satisfaction nhi hai . formula calculation se define kro
@bishantkumar12589Күн бұрын
Ok
@badalmishra27882 күн бұрын
Why only in local download possible Why not in remote
@bishantkumar125892 күн бұрын
Maybe because of the drive internal setting. I'm not sure bro
@pallabgolui13046 күн бұрын
Thanks...
@bishantkumar125896 күн бұрын
Welcome 🤗
@mohammadgulphamahmad5947 күн бұрын
Off karne ke baad v kuch kuch frequency me run karts h kya
@bishantkumar125896 күн бұрын
15-20 seconds tak karta hai. Ramp down time kahate hai use
@mohammadgulphamahmad5946 күн бұрын
@@bishantkumar12589 bms se off karte h but vfd me 0.6 hz rahta hi h esliye motor chalta rahta h
@mohammadgulphamahmad5946 күн бұрын
@@bishantkumar12589 esliye kya koi programing miss h ya kuch aur
@mrchiefjena3557 күн бұрын
SPD MATCM FLT
@daljitsingh356211 күн бұрын
sir i need your help my siemens vfd error f30665 how i can solve this fault
@bishantkumar1258911 күн бұрын
Error - system is defective Remedy - carry out a Power on off Or Upgrade firmware to later version
@SABRi000011 күн бұрын
please bro
@bishantkumar1258911 күн бұрын
🙏🏼
@SABRi000011 күн бұрын
bro please give me these drawing im one of your follower
@bishantkumar1258911 күн бұрын
Share your mail id
@SABRi000011 күн бұрын
aslam-o-alaikum bro
@bishantkumar1258911 күн бұрын
Namaste bro
@shubhammhatre17912 күн бұрын
👍👍
@bishantkumar1258912 күн бұрын
Thank you bhai for your support 🙏🏼
@cnurajitha795412 күн бұрын
Drive tripping during running PPcc link failure
@bishantkumar1258912 күн бұрын
Check the connection from inverter module main circuit interface board, INT to PPCC Branching unit.
@yokeshvaradharajan350013 күн бұрын
Sir, In ABB ACS 800 Drive was workikg in local station and CDP. But not working through Remote. We check the drive reference also. Found 10mA. But drive output not passing....
@bishantkumar1258912 күн бұрын
Any error on display?
@bishantkumar1258912 күн бұрын
Loop the start command in drive panel. If drive is passing, check the Rio relay and plc system
@yokeshvaradharajan350012 күн бұрын
@@bishantkumar12589 no error sir
@yokeshvaradharajan350012 күн бұрын
@@bishantkumar12589 we all interlock through plc and drive also
@yokeshvaradharajan350012 күн бұрын
@@bishantkumar12589 drive reference in logic was ok
@juliocesarmorenoortiz909913 күн бұрын
Hello Sir, How can I change the profibus node through the LCD display?
@bishantkumar1258913 күн бұрын
I need to check sir. I'm not sure about it
@Craigtucker99Tucker-zx1yd16 күн бұрын
Thank you please make more
@bishantkumar1258915 күн бұрын
Sure sir
@bishantkumar1258912 күн бұрын
Please check my ABB playlist. You will find some more useful drive videos there
@arymad16 күн бұрын
Superb
@bishantkumar1258915 күн бұрын
Thanks 👍🏼
@prabhakaran471617 күн бұрын
ABB vfd acs 800 *Line conv FF51 *Drive temp 4210 This type of fault came our side vfd . How can i solved
@bishantkumar1258917 күн бұрын
FF51 - shift panel from motor side convertor control board to line side convertor control board. 4210 - check air flow in drive and cooling fan condition
@md.shahid430518 күн бұрын
Agar vfd auto me nahi chalta hai to kya kya check karna chahiye.
@bishantkumar1258917 күн бұрын
Panel ko local mode me change kar do ar panel se run kar sakte hai
@ChandanKumar-pr9us18 күн бұрын
Hi this is chandan Kumar Sharma I have one problem ACS800-04-0050-5 drive alarm fault Al <Min Function(8110) same day alarm comming 10 time same day running property I not get any solution so hot to do solved that
@bishantkumar1258918 күн бұрын
Sir, drive is tripping because the analog signal i.e. 4-20mA signal to drive is continuously fluctuating. Better to check it and provide an isolator.
@rajkumarpujari842619 күн бұрын
Panel se speed control kaise kare
@bishantkumar1258919 күн бұрын
HMI ko local mode me daal k up down button se speed control hota hai
@bishantkumar1258919 күн бұрын
Video available hoga ABB playlist me
@rajkumarpujari842619 күн бұрын
Thank you
@aniketupadhyay714519 күн бұрын
Superb explanation sir
@bishantkumar1258919 күн бұрын
TQ sir. Happy to help.
@madhusudansharma736820 күн бұрын
Some vedio only troubleshooting me banaiye jisme VFD to PLC communication error, fault , failure to start , faculty plc card , all in details ho....
@bishantkumar1258919 күн бұрын
Sir. Troubleshooting pe videos uploaded hai. Aap ek baar ACS playlist check karo. PLC related error ar upload karunga in near future
@madhusudansharma736820 күн бұрын
Agar auto me system work nhi kar Raha hai ,uski troubleshooting details me vedio baniye....jada problem isi se related aati hai
@bishantkumar1258919 күн бұрын
Sir. Troubleshooting pe videos uploaded hai. Aap ek baar ACS playlist check karo. PLC related error ar upload karunga in near future. Please check and let me know aur kya add kar sakte hai sir. TQ
@madhusudansharma736819 күн бұрын
@@bishantkumar12589 aapke channel ke vedio shandaar hai.... knowledgeable and way presentation exillant...
@bishantkumar1258919 күн бұрын
Thanks sir. Kindly share with your electrical team 🙏🏼
@KGopidas20 күн бұрын
Cooling is bonus!!!
@bishantkumar1258919 күн бұрын
Right sir 😛
@rajeshparmar694420 күн бұрын
Sir thx a lot for ACS 580 presentation. Had one query appreciate your input..if any Of VFD model ( ABB or other) got hot redundant communication ( dual ports) . Pl advice. Thx n regards rajesh
@bishantkumar1258919 күн бұрын
Welcome sir. But as per my experience, I didn't find any.
@shubhammhatre17920 күн бұрын
👍👍
@bishantkumar1258920 күн бұрын
TQ dost
@user-rj7hs6lm1e21 күн бұрын
Hello sir 🙏 app k what's up number chahe sir Mai Nigeria Mai Job Kar hoo mera question tha Discussion Karn hai plz Sir. From odisha Jay Jagannath 🙏
@bishantkumar1258921 күн бұрын
Hello bhai. Kya problem hua h. Batao. Kaun si company me ho waha ? Quantum group?
@sandipnishad243221 күн бұрын
Drive me rmp kaise kam jyada kre hai use btao plz
@bishantkumar1258921 күн бұрын
Control/PLC se 4-20 mA se speed change hota hai. Aur local mode me HMI panel se kar sakte hai
@Lifeinfi22 күн бұрын
NC is used because if suddenly NC contact is fail the it will become no and circuit stops for safety purpose and If used no instead of nc contact and no contact suddenly fails it becomes Nc means no cut off of ckt and if some incident happen and you try to stop supply it wont work so chances of accident... Thats why emergency always connnect with NC..
@bishantkumar1258922 күн бұрын
Okay 👍🏼 TQ
@kaushikkhetalpar510124 күн бұрын
Sinamics G120 fault 30055
@bishantkumar1258924 күн бұрын
F30055 Power unit: Braking chopper overcurrent Reaction: OFF2 Acknowledge: IMMEDIATELY Cause: An overcurrent condition has occurred in the braking chopper. Remedy: - check whether the braking resistor has a short circuit. - for an external braking resistor, check whether the resistor may have been dimensioned too small. Note: The braking chopper is only enabled again at pulse enable after the fault has been acknowledged.
@bishantkumar1258924 күн бұрын
Check for Over current fault, check motor and power cables first, later condition of drive
@kaushikkhetalpar510124 күн бұрын
@@bishantkumar12589 there is fault in VFD?
@kaushikkhetalpar510124 күн бұрын
@@bishantkumar12589 there is no problem in Motor as well as in wire .
@bishantkumar1258922 күн бұрын
Ya then fault with drive only
@user-kx8qz6cg9n25 күн бұрын
sir Ji Thank you very much , ye signal Isolator Audio me jo humming aha raha hai use nikal sakta hai
@bishantkumar1258925 күн бұрын
Sayad nai. Aap ek baar check kar sake too mujhe v batana. Maine check nahi kiya h
@recipesbyaai26 күн бұрын
Superb explanation
@bishantkumar1258926 күн бұрын
Thank you 🙏🏼 please share this channel with your electrical team 🙏🏼
@recipesbyaai26 күн бұрын
Sure@@bishantkumar12589
@technews870226 күн бұрын
bro acb maintenance ki video dalo
@bishantkumar1258926 күн бұрын
Okay bhai. Thoda time lagega
@technews870226 күн бұрын
Ok wait kr rhe aap ki video ka
@bishantkumar1258922 күн бұрын
Okay bhai. TQ
@technews870226 күн бұрын
thank you very nice
@bishantkumar1258926 күн бұрын
Welcome 😊
@daleshwarpatel478929 күн бұрын
Sir please explain how HT motor relay identify overload protection or relay know it is overload protection
@bishantkumar1258929 күн бұрын
It's as per the setting in the relay. Value can be around 2-3 times the rated current
@austinf381029 күн бұрын
Great video!
@bishantkumar1258929 күн бұрын
Thanks man 👍🏼
@RajSingh-cb5tqАй бұрын
ACS560 drive me fault 2310 hai to kaise sahi kare kya kare please contact me
@bishantkumar12589Ай бұрын
Hello bhai
@RajSingh-cb5tqАй бұрын
Mughe kuch puchana tha
@bishantkumar12589Ай бұрын
Bhai. Apka drive " Over current " fault pe trip kar raha hai
@RajSingh-cb5tqАй бұрын
Hii bhaiya
@bishantkumar12589Ай бұрын
Check the power cables and motor insulation values
@sathapanaseemathong389Ай бұрын
Excuse me sir. If my SCR . AG=OL VDC, GC=0.004VDC, AC=OL VDC. It can work?
@bishantkumar12589Ай бұрын
I doubt it, as GC is almost shorted sir. As per my test it should be OL
@sathapanaseemathong389Ай бұрын
@@bishantkumar12589 Thank you very much sir. You are very kind.
@bishantkumar12589Ай бұрын
Welcome sir.
@youtubecrazy1472Ай бұрын
Icu fan baypass video banavo
@bishantkumar12589Ай бұрын
Bypass possible nai h. Humne ABB service engineer se ye issue discuss Kiya tha. Laptop 💻 se configuration hi karna hoga
@swastikdutta2267Ай бұрын
Best
@bishantkumar12589Ай бұрын
Thank you 🙏🏼 kindly share this channel with your electrical team 🙏🏼
@swastikdutta2267Ай бұрын
❤❤@@bishantkumar12589
@dibyajyotibagdi6140Ай бұрын
HPP Warning Reset kaise kare ?
@bishantkumar12589Ай бұрын
kzbin.info/www/bejne/gmWyhqOJa76Ua9k
@bishantkumar12589Ай бұрын
Try this step 🪜
@ravijadhav4419Ай бұрын
me naya hi muje vfd ke bareme jada jankari nahi he mere pass power plex 40 vfd he usko muje lcs plc and feed back ka wiring keise karu sir plz batav
@bishantkumar12589Ай бұрын
Powerflex 70 ka ek video h mere is channel pe, aap dekh lo
@ravijadhav4419Ай бұрын
ham control wiring 110v ka karte he or relay ko vfd di 24 v dc dete he to relay me kohi dikat nahi hoti kya
@bishantkumar12589Ай бұрын
Mujhe powerflex40 ka wiring dekhna hoga, thoda wait Karo aap
@ravijadhav4419Ай бұрын
mere pass power flex 40 drive he use me plc stsrt stop and feedback wiring keise karu sir plz batav
@bishantkumar12589Ай бұрын
Check kar k batata hu, wait for sometime brother. Maine powerflex40 pe kaam nai Kiya h pahle
@ravijadhav4419Ай бұрын
@@bishantkumar12589 ओके sir
@shubhammhatre179Ай бұрын
👍👍👍
@bishantkumar12589Ай бұрын
🙏🏼🙏🏼
@abhishekkumar-ze3dxАй бұрын
I just want this topic to be know because in every manufacturing industry belt conveyor is main for product transport I request you to make more videos and interview questions on it
@bishantkumar12589Ай бұрын
Sure sir. Next video will be on Q&A of Conveyor belt system
@ganpatsinghrisingperson4194Ай бұрын
Ye kitne kw ki hai
@bishantkumar12589Ай бұрын
5.5 kW
@gangadhardas1432Ай бұрын
Very nice 👍💥💥 video
@bishantkumar12589Ай бұрын
Thank you 🙏🏼 please share this channel with your electrical team 🙏🏼