Thanks to sharing your experience with us. If I’m want to learn more about this topic, can I search where??
@Marsk1tty2 күн бұрын
Plastic was a mistake :(
@chunjeaishatou55244 күн бұрын
Thank you for this, quite educative
@JebsTennisJourney5 күн бұрын
Can you arrange the linkages on an oversized valve to where it only opens 70% at max? The difference in Cv between 4" and 6" (70.1 and 277) is huge. We have a 6" but the 4" would be way to small.
@briantxcattleskull27525 күн бұрын
Very informative
@Adam-en4zm6 күн бұрын
Well, just finished up the playlist. Pretty interesting stuff. Even though I'm a video game programmer, and will probably never need to know any of it, pretty fascinating to see how hydrocarbons are refined before they are delivered to us!
@jobautomation7 күн бұрын
Thanks!
@worldbeststories10 күн бұрын
best oil trading book i have ever read : title : DAY-TO-DAY OIL & GAS TRADING AND SHIPPING DELIVERY INSIDE THE OIL & GAS MARKET
@adamben-shimon751310 күн бұрын
Great video and educational. I learned something new.
@davisonaigbekaen256811 күн бұрын
Thanks for the video. I work for an Oil and Gas company as an instrument tech. More often, we experience excessive glycol foaming in the TEG contactor making the differential level transmitter reading not being in synch with sight glass readings and that of the control room. We currently push glycol at over 225 Degree Fahrenheit and the inlet gas at 90 Degree Fahrenheit to the TEG contactor. And the differential temperature, as you can see, is more than the 20 Degree Fahrenheit you talk about. I have suggested the solutions you provided in the video, but my superiors are saying it is not possible in that the glycol with such a differential temperature of 20F cannot dry the gas. Please is there more info you think that will help solve this excessive foaming of glycol? I look forward to hearing from you ASAP. Regards, Davison
@KimrayInc11 күн бұрын
Davison, first let me preface this reply by saying that Kimray can offer technical support for products that we manufacture, like the glycol pump, but we are not experts in dehy equipment and cannot officially suggest your best practices or how to operate your equipment. That said, we can share some knowledge about the subject for you that may help. - The dry glycol temperature at the dry glycol inlet should be no more than 20 degrees F greater than the temperature of the wet gas. The glycol entering the top tray may raise the temperature of the gas surrounding it and prevent the gas from giving up its remaining water vapor. - Also, a drastic temperature differential tends to emulsify the glycol with any contamination it may contain. This causes excessive glycol foaming and subsequent glycol loss. - The longevity of the energy exchange pump will also suffer if the dry glycol temperatures are above 200 F. Ideally the lean glycol needs to be 150-160 degrees F.
@MiaWang-zd2sz11 күн бұрын
good video
@Nur_Md._Mohiuddin_Chy._Toha14 күн бұрын
👍👍👍👍👍
@Drillingmaps15 күн бұрын
Nailed it. Thanks for sharing. blog.drillingmaps.com/2024/05/the-impact-of-using-13-million-gallons.html
@deadby1616 күн бұрын
Wow!
@bumgunp16 күн бұрын
thank you a lot for the great video.
@tinnieds1618 күн бұрын
thank u
@josephsansevero409918 күн бұрын
Has there been a fosil found below 16k feet?
@eng.faisalsaad374619 күн бұрын
❤
@user-nk8tf3sb3t20 күн бұрын
Wonderful video
@llewellynpatrick16021 күн бұрын
Thank you - this was very helpful.
@akposevbegeorge45822 күн бұрын
Very helpful,thanks.
@thanzawwin45923 күн бұрын
Thanks
@dorinekamgue588125 күн бұрын
Morning . Please Can you give us the mechanical characteristics of the Esp pump??
@2626woodsyАй бұрын
incredibly informative- thank you for making this
@ismailbolod7421Ай бұрын
Well done boss, please can you make a video on the difference between wellhead PCP and wellhead ESP
@charloskarlos6797Ай бұрын
Hello sir, can the sumersible pump install horizontal?
@KimrayIncАй бұрын
ESPs can be used in both vertical and horizontal wells.
@charloskarlos6797Ай бұрын
@@KimrayInc noted, thanks a lot sir
@stijn2472Ай бұрын
Great video! If I remember it right, the engines powering the compressors themselves "bleed off" some of the gas as fuel, right? How much fuel do they consume? Is it a significant amount?
@quentinulysses8237Ай бұрын
I work for AG it’s cool to see the compressor out in the field
@RandointerwebzdudeАй бұрын
Thank you very much. I’m on a location with minimal cell service trying to figure out how to adjust the gen III’s. This was a godsend.
@0mfgBBQZАй бұрын
Any chance we could get some info on the Gen2? Can’t seem to find any info on them
@KimrayIncАй бұрын
We have a playlist with all the videos we have made about our float operated controllers, which would include the Gen II. This list has a few about displacer options, troubleshooting, how they work and using them with for interface control. We have been focusing a lot on the new Gen 3, but can continue to support you however you need for the Gen II. Please let us know if you need any other specific info or help! kzbin.info/aero/PLkkvy2djnFddbPh97BYlJy38fJ5zVErs8&feature=shared
@JM-gs1qpАй бұрын
Thanks for the information. Very valuable.
@santoshpatnaik1988Ай бұрын
Best presentation of gas lift
@asta5475Ай бұрын
Great
@garystell77Ай бұрын
Yes I do know how it works! I’ve sold more of them than I can remember!
@RufalinoRufusАй бұрын
Thanks
@XYZ-Drafting_and_DesignsАй бұрын
Well done my brotha!
@Kimberlie-uh9brАй бұрын
Waste oil refining project, welcome to contact with me 🎉
@adejorjoseph3863Ай бұрын
Thank you Kimray, I really enjoyed your training video..
@Mrn0Ай бұрын
Thank you. Great videos
@Kimberlie-uh9br2 ай бұрын
I didn’t figure out 😢too fast
@deleterfanboy190025 күн бұрын
basically different hydrocarbons have different boiling points and they use that to capture them at different points, which they are then refined and conditioned and sold. different hydrocarbons have different properties so theyre suited to different tasks. ask if other questions
@samueleneojo81592 ай бұрын
Great video Perfectly detailed and explanatory. How much will it cost to put up this type of unit? Thanks.
@areejal98322 ай бұрын
Hi is it cost effective to reuse the ESP on another well after the first well dry?
@KimrayInc2 ай бұрын
Sorry, you'd need to refer to the manufacturer to answer that question. We're not properly able to speak to that exactly!
@piping20242 ай бұрын
🙏🙏
@shjo27782 ай бұрын
They make Rockefeller look like the oil genius
@Eco192 ай бұрын
What kind of carbon steels are sometimes used for the plungers?
@KimrayInc2 ай бұрын
Sorry, you'd need to refer to the manufacturer to answer that question. We're not properly able to speak to that exactly!
@TenyJamesTap2 ай бұрын
Tremendous presentation
@0mfgBBQZ2 ай бұрын
I want a Kim Ray sticker like that!
@KimrayInc2 ай бұрын
We can get those for you! Email [email protected] and our Marketing Coordinator can send you some Kimray stickers for sure. I'll let her know to look for your email.
@0mfgBBQZ2 ай бұрын
@@KimrayInc email sent! :)
@mannymrtz49402 ай бұрын
Good stuff. This is great for field employees, especially lease operators to learn how equipment actually operates.