Pivot Control Panels - Smart HOA
3:53
Pivot Panel Webinar Part II
32:28
Жыл бұрын
Low Pressure Sewer Overview Webinar
1:01:29
Features: Pivot vs Pivot Pro
2:00
Pivot Your Thinking.
2:16
Жыл бұрын
Pivot Panel Introduction Webinar
33:52
72 HD Series Grinder Pumps
1:40
Жыл бұрын
Zoeller Pump Product Trailer
1:02
2 жыл бұрын
Qwik Jon Premier Upflush Systems
1:07
Пікірлер
@silverbankruptcy
@silverbankruptcy 13 күн бұрын
My Opinion is that Considering the High Cost of Labor, It Just Pays to Buy the best one. It's not worth having to Replace it. I bought an M95 and Zoeller was Very Helpful on the Phone. I am Just using it for a hole that fills from a Washing Machine and a Central AC. Works Great! kzbin.info/www/bejne/gIKzommDf6mBpck
@petebusch9069
@petebusch9069 Ай бұрын
What is your answer to the switch housing filling with water making it not work? This has been a common problem with these pumps that seems like it will never be addressed.
@ZoellerCompany
@ZoellerCompany 24 күн бұрын
Hi @petebusch9069. To learn more about our switch options, and speak directly with our experts, please email [email protected] or call 1-800-928-7867 and dial option 6. I hope this helps!
@petebusch9069
@petebusch9069 24 күн бұрын
@@ZoellerCompany My God, a canned answer with a phone number to a person that knows nothing and call that customer service. You corporate people will never get it. Now go do your job and find the person that knows the answer to this and post it so we can all see how your products have developed over the years and how you solved older problems using new technology but you purposely hide these people as though they might say something that you don't want out in the public. FFS people, get a clue.
@ZoellerCompany
@ZoellerCompany 21 күн бұрын
We're sorry sir, however, we would like to discuss your specific application and the issues that you seem to be having. We can not go into detail on the comments section of this video. We are more than willing to discuss and will stand behind the product.
@petebusch9069
@petebusch9069 21 күн бұрын
@@ZoellerCompany Ok, water gets inside your switches, all of them, what have you changed to prevent that and why are you not willing to talk about that publicly? This is the weak link in your pumps and is what keeps me from buying them. We use these in a sump pump and actually depend on them working to avoid flooding our basement. Having a high quality float is of the utmost importance and is the number one failure. As a consumer I want to know if your doing anything about this or not? As of yet I don't see anything new. So far I've received nothing but canned corporate answers from you. Yes or no, are your float switches the same as they've always been and if not what are the changes made? Your entire customer base wants to know this.
@petebusch9069
@petebusch9069 20 күн бұрын
@@ZoellerCompany Ok, so you just told whoever is reading this you don't care and have not done a thing to improve your floats. Good luck.
@petebusch9069
@petebusch9069 Ай бұрын
Too bad the float switch fails and will leak water into the housing on these pumps.
@ZoellerCompany
@ZoellerCompany 23 күн бұрын
Hi @petebusch9069. We have a few different switch options available for our pumps. If you would like to learn more about them, our experts in product support would be more than happy to walk you through the available choices. To connect with them, you can either email [email protected] or call 1-800-928-7867 and press option 6 to be connected with them. I hope this helps!
@petebusch9069
@petebusch9069 23 күн бұрын
@@ZoellerCompany Why not just address the issue instead of providing a canned response that does nothing but give your company a bad reputation? You have good pumps but your floats are junk, we all know that and end up using other floats. Do you really think avoiding that issue is in you best interest? Do you really think your fooling you customers? If you would just come out and say yes, this is the weak point and this is what we are doing about it then you might gain some respect. We all know you have a phone number, providing that does not help.
@k50159
@k50159 Ай бұрын
Thank you so much
@michaelwilkinson6145
@michaelwilkinson6145 2 ай бұрын
Thank you VERY much for this video, extremely helpful and very well done
@ZoellerCompany
@ZoellerCompany 2 ай бұрын
Glad it was helpful!
@user-yj8pw9by8z
@user-yj8pw9by8z 2 ай бұрын
Good advice I have a pedestal sump pump no problem 4 months, but if I change over I'll do as u say thanks for this video
@chadsalter9961
@chadsalter9961 2 ай бұрын
What’s the gallon per inch for an 18” basin? The basin volume per depth table starts at 24”, but most residential applications are using the smaller 18” x 30” size.
@ZoellerCompany
@ZoellerCompany 2 ай бұрын
An 18” diameter basin has 1.1 gallons per inch. Hope this helps!
@benoitlaforest6198
@benoitlaforest6198 3 ай бұрын
What is included with the pump? succion pipe and float? How deep can we place the bottom of the succion pipe?
@ZoellerCompany
@ZoellerCompany 3 ай бұрын
Good afternoon! Our installation instructions for this product have a lot of the details it sounds like you're looking for. You can check that out here: zoellerpumps.com/wp-content/uploads/sites/3/2023/10/FM3170.pdf (parts list on page 7) (Installation of suction pipe on page 3) Also, please note the suction pipe is NOT included. I hope this helps!
@corycloss59
@corycloss59 3 ай бұрын
I am a plumber and own and operate a pump servicing company. This was as well of done video as I have seen in a while and will be sharing it during our on boarding procedures. Thanks again and keep up the excellent work!
@ZoellerCompany
@ZoellerCompany 3 ай бұрын
Thanks for the positive feedback! We're glad you liked it and found it beneficial!
@sklinkner
@sklinkner 4 ай бұрын
Nice - helpful video
@ZoellerCompany
@ZoellerCompany 4 ай бұрын
Thanks @sklinkner. Glad it was helpful!
@sklinkner
@sklinkner 4 ай бұрын
@@ZoellerCompany I have a 10-0093 controller with what I now understand to be a Stop float which is working intermittently. This was clear after watching the video but wasn't easy to figure out from the written docs I was initially able to find online. Basically if Lead LED is on and Stop LED is off, that's an unexpected state.
@corporatebryan
@corporatebryan 4 ай бұрын
How does the controller calculate pump runtime? I have a new unit that I installed only a few days ago and I’ve only run it for testing yet it says it has 2 days of runtime on it. I did have the controller plugged in without the pump plugged in for a day or 2.
@ZoellerCompany
@ZoellerCompany 4 ай бұрын
Good morning! Should you require technical support or troubleshooting assistance for your application our Product Support team is more than happy to help out! They can be reached by emailing [email protected] or calling 1-800-028-7867 and selecting option 6. I hope this helps!
@corporatebryan
@corporatebryan 5 ай бұрын
Where can I get extra o-Rings?
@ZoellerCompany
@ZoellerCompany 5 ай бұрын
Good morning! If you call into our Product Support Department they can get some to you! Email [email protected] or call 1-800-928-7867 extension 6.
@moltenpros
@moltenpros 5 ай бұрын
If you know the hole get clogged easily, why not design it differently?
@theNdrexel
@theNdrexel 5 ай бұрын
Great delivery from the presenter. The cholesterol joke hit. Good info!
@KickYouInTheThroat
@KickYouInTheThroat 5 ай бұрын
What would cause the 2A control power fuse blow in a simplex? I cleaned off a float that was jammed up and put it back in. I am waiting on fuses. Could it be something else?
@ZoellerCompany
@ZoellerCompany 5 ай бұрын
Good morning! If you reach out to our product support department by emailing [email protected] or by calling 1-800-928-7867 and pressing option 6, our product experts can help you troubleshoot your specific application. I hope this helps!
@geniferteal4178
@geniferteal4178 5 ай бұрын
How do i prevent freezing of a pump that must be outside?
@ZoellerCompany
@ZoellerCompany 5 ай бұрын
Good morning! Our Product Support experts would be more than happy to help you troubleshoot your specific application. You can reach them at [email protected] or by calling 1-800-928-7867 and pressing option 6. I hope this helps!
@Jay-fp8iy
@Jay-fp8iy 5 ай бұрын
Thank you!
@n121pp67
@n121pp67 5 ай бұрын
Wow using a black table really helps us see the pump! Not!!!
@ZoellerCompany
@ZoellerCompany 5 ай бұрын
Sorry it's a bit difficult to see on the table in the video. We do offer in person training in our 6,000 square foot facility where you and your team can see the pumps up close and in person and see our full demos all guided by our specialists with years of experience at Zoeller and in the field. If you're interested, you can reach out to your local Zoeller Rep for more details. (Rep List: www.zoellerpumps.com/sales-support/sales-representatives/). Here is also a link to more details on a visit: www.zoellerpumps.com/training/zoeller-university/zoeller-university-on-campus/. We can tailor experiences to just the things you and your group want to see or cover. We hope you'll consider seeing them in person with us sometime.
@pseyedoc
@pseyedoc 7 ай бұрын
good video
@ZoellerCompany
@ZoellerCompany 7 ай бұрын
Glad you enjoyed
@PCostello
@PCostello 8 ай бұрын
How do you convert a standard float switch M53 to use a float-less LN style switch? What parts to order? What is used for the pump top?
@ZoellerCompany
@ZoellerCompany 8 ай бұрын
So, since this video was made we have stopped selling the LN switches. We used to offer a specific Part Number pump that CAME with them. We do have SEVERAL other switch options though despite dropping the Floatless. If you contact our Product Support department at 1-800-928-7867 and press option 6, or email them at [email protected], one of our product experts will help you find the best available switch for your application and be able to provide you with the exact part numbers you would need. I know this isn't exactly what you were hoping to see, but I hope it helps!
@jeffrx
@jeffrx 9 ай бұрын
Why don’t they just come with a pre-drilled vent hole?
@ZoellerCompany
@ZoellerCompany 8 ай бұрын
Our Model 53 does come with a pre-drilled vent hole on the pump that you can see in the cover photo for this video, but that can become clogged up on the pump fairly easily. If a check valve is used, we recommend drilling a vent hole in the discharge pipe. This hole should be located within the basin between the pump and check valve, usually a few inches above the pump “on” level but below the pit cover. The vent hole will prevent air-locking from occurring. It's a pretty small step to prevent a bigger headache from happening down the road. We hope this helps! Should you have any further technical questions, please contact our tech support team at [email protected] or 1.800.928.7867 and press option 6.
@ivanmaldonado3149
@ivanmaldonado3149 11 ай бұрын
Can this be installed in a laundry room and use the washing machine drain as the waste drain for this type of toilet. The washing machine drain also used as vent line it goes to top of roof.
@ZoellerCompany
@ZoellerCompany 11 ай бұрын
Good morning! We have a product support department that can answer your question. You can either email [email protected] or call them by dialing 1-800-928-7867 and pressing option 6. I hope this helps!
@gregoryharington6686
@gregoryharington6686 Жыл бұрын
I was not aware that there is a vent line forming part of the system.
@edwardjohn1614
@edwardjohn1614 Жыл бұрын
Anything that drains whether by gravity or pressure needs a vent to work properly or in some cases to work at all. 👍
@tylerchapman8856
@tylerchapman8856 Жыл бұрын
How many psi does the 2 inch 3 hp create
@ZoellerCompany
@ZoellerCompany Жыл бұрын
For technical questions, you can reach our Product Support experts at 1.800.928.7867 (and press option 6) or email them at [email protected]. I hope this helps!
@VideoMyLifeLLC
@VideoMyLifeLLC Жыл бұрын
Great intro video! I need help with my M137-D. Two years old and I had to replace the capacitor (no big deal), but after only two weeks the pump is throwing the breaker. I cannot find any obvious signs for failure, and am looking for specs on ohms, etc. to troubleshoot the capacitor etc. Also, the schematic is helpful, but actual pictures of the wiring would be VERY helpful. Anyone know of a good website with photos and troubleshooting values? Oh, the impeller spins easily, there were no signs of water in the pump, etc. Thanks!
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning! We have an entire department that offers Technical Support. You can reach them at 1.800.928.7867 (and press option 6) or email them at [email protected]. They should be able to help you troubleshoot your application and/or point you to some great resources. I hope this helps!
@GUNNERBASS
@GUNNERBASS Жыл бұрын
What is your recommendation for somewhere like Los Angeles with unpredictable, inconsistent rain? We got soaked this year, 40”+. Large amounts of rainfall all at once with these storms. Now in the summer and fall we’ll get no rain for 6 months. Seems unlikely that the pump can stay submerged year round.
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Hi! Our Product Support experts can help you out with this! You can either call them at 1.800.928.7867 and press option 6, or you can email them at [email protected]. I hope this helps!
@gteran
@gteran Жыл бұрын
My 2hp sewage pump setup worked flawlessly for 3 years but now the weep hole keeps getting clogged. Do you think my cutter is dull and allowing too many solids out of the discharge??
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning! Our technical support staff can help you troubleshoot your application. You can reach them by emailing [email protected] or by calling 1.800.928.7867 and pressing option 6.
@billwheeler1213
@billwheeler1213 Жыл бұрын
Good talk, would have liked more visuals.
@robertzacks3002
@robertzacks3002 Жыл бұрын
I see some distributer see the model M98-0001 and some sell the M98-0006, does anyone know what differences are?
@dluuc
@dluuc Жыл бұрын
"Fantastic source of information." Is it? you made a presentation for 40 minutes of video and did not talk about what it is- Weep Hole on the side of yours product. in my case, the hole rusted because the pump did not work for a year. the hole has been stuffed. But even this is not the problem, the problem is that the motor does not spin at a speed to raise the water to the required height. i checked the pump in october and it was working, now end of april the pump is no longer working
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning! This webinar is on our sump pump line and the switch options that are available with them. If you're having an issue with your product we recommend you reach out to our product support department at [email protected] or by calling 1.800.928.7867 and pressing option 6. Our product experts would be more than happy to troubleshoot the issues you're experiencing. I hope this helps!
@ap2291
@ap2291 Жыл бұрын
What is considered a small pit versus a large pit? It would be helpful to give a general guideline range of small v. large pits.
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning! If you reach out to our Product Support department at [email protected] or call them at 1.800.928.7867 and press option 6 they can answer your question regarding pit size and might even be able to provide some helpful materials for you depending on what you're doing/details you're needing. I hope this helps!
@kevinf8310
@kevinf8310 Жыл бұрын
The top of the line LN series pump switch is already listed as obsolete, one year after your webinar. Zoeller, please explain..
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Unfortunately, the switches utilized in the LN "Floatless Series" pumps became unavailable causing us to obsolete the series. We apologize for any issues this may cause but would be more than willing to assist in selecting a switch style for your application, if needed. To assist you with this our Product Support experts can be reached at [email protected] or by calling 1.800.928.7867 and pressing option 6. I hope this helps!
@gguzman1000
@gguzman1000 Жыл бұрын
Very good explanation. Thanks!
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Glad it was helpful!
@williamfindlay9525
@williamfindlay9525 Жыл бұрын
Does anyone know the procedure for refilling the pump housing. Is mineral oil used or machine oil? How much oil is used? Enough to cover the miter completely?
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Hi - if you contact our Product Support department at [email protected] or by calling 1.800.928.7967 and pressing option 6, they should be able to answer this for you.
@grantgordon8107
@grantgordon8107 Жыл бұрын
I’m still getting a 3-beep alarm after recharging my sump pump’s back-up battery and confirm it’s in Good status at an Auto Zone. There was never an Input 1 LED/alarm. Is it possible this alarm is going off because of low AA back-up batteries in the alarm itself?
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Hi - if you contact our Product Support department at [email protected] or by calling 1.800.928.7967 and pressing option 6, they should be able to walk you through the issue you're experiencing and provide a solution. Hope this helps!
@teddematteo3719
@teddematteo3719 Жыл бұрын
Had my grinder replaced in June 2022. Have had problems with pump alarms going off after 3 months. Have had the plumber out her numerous times over the last 6 months. They keep replacing parts and now the alarm go off every time we run water, run dishwasher, washer, take showers etc. They want to replace more parts, but I feel I can't trust it. They need to replace the entire panel, but as of this date they will not. Buy something else.
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning. I'm sorry to hear you're having trouble with one of our pumps. We do have a talented team of product support specialists that might be able to help you troubleshoot your application if you would like to contact them they can be reached at [email protected] or 1-800-928-7867, extension 6.
@jpadilla0515
@jpadilla0515 Жыл бұрын
If this is a problem why not dril it from factory?
@ZoellerCompany
@ZoellerCompany Жыл бұрын
We do include a predrilled 3/16" vent hole on a lot of our bottom intake pumps, but we still recommend a 3/16" hole be drilled in the discharge PIPE between the discharge of the pump and the bottom of the check valve, just in case the predrilled hole we made in the pump body gets clogged. I hope this helps!
@essys1991
@essys1991 Жыл бұрын
Fantastic information!
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Glad it was helpful!
@ronbelford
@ronbelford Жыл бұрын
Parts list for model m267-f
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning! Zoeller parts lists are typically accessible through shop.zoeller.com. However, the 267-f list seems to be missing, so I've notified the admin for that site to put the parts list back online. We apologize for that inconvenience. Should you need a parts list immediately, you can reach out to [email protected] and request one be sent to you. Again, we apologize for the oversight on our parts site and will be correcting that as soon as possible. I hope this helps!
@davidbasha5358
@davidbasha5358 Жыл бұрын
My plumber drilled the 3/16" hole on the outlet pipe below the water level real close to the outlet of a 1/2 hp model 267 waste ejector. after seeing that and reading that the hole should be drilled above the water level where the pump turns on, he drilled a second hole. My concern is if having two 3/16" holes will cause the pump longer than it should since water is escaping while the pump is running. This bring me to my next question, what is the normal run time per cycle to empty a standard 18" x 30" simplex pit?. The lift is about 12ft straight with one 30 degree bend and has a check valve installed about 2 ft above the top of the pit.
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Good morning! Questions like these are more fit for our product support staff. You can reach them by emailing your comment here to [email protected] or calling 1-800-928-7867 and pressing 6 from the menu options to reach one of our experts. I hope this helps!
@RandyWells24
@RandyWells24 Жыл бұрын
its called Gravatron lol
@michaelcostello6991
@michaelcostello6991 Жыл бұрын
Love the description of relays. They are very simple but wiring can be very complicated. Good warning :)
@michaelcostello6991
@michaelcostello6991 Жыл бұрын
Is there any videos on old relay control pump panels. The circuitry can be complex.
@ZoellerCompany
@ZoellerCompany Жыл бұрын
We don't currently have any videos out like this. If you have a question about a Zoeller product and need support, please email us as [email protected] or call 1-800-928-7867 and select option 6 for our Product Support Specialists.
@RRaucina
@RRaucina Жыл бұрын
I have 2] M-53 pumps with water filled switch boxes. Incredibly they both still ran but the heat they gave off and the small shock from touching the housing told all. You guys make a fine usa product and I have other pumps with auxiliary float switches that are decades old. But I am done with the 53 or 57's and their incorporated floats. Going to Liberty. At least it is also USA made. Rethink your built in floats! Too many points of potential water ingress.
@chadsalter9961
@chadsalter9961 2 ай бұрын
I had the same issue, switch seal failures & not enough travel equalling a short-cycling pump. I just bypassed the built-in switch & get a quality float switch, or one of the many new solid-state controllers available on the market, Zoeller even offers one.
@RRaucina
@RRaucina Жыл бұрын
Stop making those value line shit pumps in China and Taiwan. Love the 57 and 53's and have tons, but indeed your switch design is pretty lame.
@victorluna4926
@victorluna4926 Жыл бұрын
This is an incredible equipment to use in some spaces where you can't cut the slab!!! It's amazing!!!
@victorluna4926
@victorluna4926 Жыл бұрын
Thanks for the video, is awesome this product!!! I would like to know a little bit ore about this, i see that you have 2 pipes (maybe of 2" of diameter) in both sides of the tan, Those pipes are to receive the sanitary instllation of other equipments, like a basin? Greetings
@ZoellerCompany
@ZoellerCompany Жыл бұрын
The two inlets on either side of the unit allow you to connect your tank to other equipment like a shower or a sink. If you have any further questions about this product, please email us as [email protected] or call 1-800-928-7867 and select option 6 for our Product Support Specialists.
@whocares0503
@whocares0503 Жыл бұрын
Leaving out the 200 series? I bought an M267-H with reviews saying this could be my last pump, we'll see...
@ZoellerCompany
@ZoellerCompany Жыл бұрын
Hi! This video covers our sump pumps. Model 267 is a Sewage Pump. If you have a question about the 267 or 200 Series, please email us as [email protected] or call 1-800-928-7867 and select option 6 for our Product Support Specialists.
@SilentServiceCode
@SilentServiceCode Жыл бұрын
Air lock holes are so annoying to listen to when they spray everywhere, so I avoid pumps that need them
@user-yj8pw9by8z
@user-yj8pw9by8z 2 ай бұрын
Have u had any trouble I have a pedestal sump pump no trouble 4 months lucky so far
@22_floW
@22_floW Жыл бұрын
So what's considered "high head?" My Zoeller Waste-Mate 267-0001 Sewage Pump, 1/2 HP doesn't have the 3/16ths hole yet and this week, it got "stuck" from the air pocket as it's been drought-like conditions where I live. So I'm considering the hole now and I understand that it needs to be drilled below the check valve and above the discharge at a downward angle so that any spray lands in the sump pit...but the instructions say that if you have a "high head," you might want to avoid this. My pump pumps up to about 3.5 - 4.5 feet before crossing through the silent check valve, then up another 2.5-3 feet before doing a 90 and heading about 40 or so feet before going downward into the city rainwater. Is the "head" the portion of pipe that water goes through until it reaches the check valve? If so, adding the vent shouldn't hurt anything, right?
@ZoellerCompany
@ZoellerCompany Жыл бұрын
If you have a question about a Zoeller product and need support, please email us as [email protected] or call 1-800-928-7867 and select option 6 for our Product Support Specialists.
@NoName-gv6nm
@NoName-gv6nm Жыл бұрын
Just drill the weep hole about even with with top of the pump. It will be fine. I had my pit dry out during a drought as well, and also caused air lock. After I drilled the weep hole, it never had a problem again. You won't lose that much efficiency from the weep hole. It's better than having a pump burn out and cause flooding.
@22_floW
@22_floW Жыл бұрын
​@@NoName-gv6nm, totally agree. I'm happy I drilled mine. However... One thing worth noting for people with exit lengths installed within joist locations is that the hole introduces air into the line and this can increase noise of the respective cycles due to how air pockets get trapped within pipes. It shouldn't be enough to cause major problems, but as a result, it does increase noise within the exit pipe as water travels out and air within the pipe slides around inside the line, the severity of which depends on where and how the exit line(s) are installed within a home (i.e. - if the exit line is suspended from joists via hangers that struggle to dampen vibration caused by the water sliding around once the cycle ends or if the line pumps along an upward grade during its journey to daylight). There's a lot to it and results vary between homes and their respective configurations.
@NoName-gv6nm
@NoName-gv6nm Жыл бұрын
@Wolf_22 yeah I can see that being an issue for sure. It certainly causes more noise. Lucky for me, my pit is about 2 feet from the wall. Only about 5 feet of pipe. So it's dead silent in my home. Maybe there's something you can do to dampen vibration? Cheers 🍻
@22_floW
@22_floW Жыл бұрын
@@NoName-gv6nm, there is. When I first moved in, I had to run about 20' worth of exit line through the entirety of my basement + crawlspace as the endpoint was the only way to reach daylight. Since then, I've managed to get my town's mayor to martial his troops and get an 8" drain line installed in my backyard (which connects to the city main line). So, this summer I'm rerouting everything back to that through my back basement wall, which translates to disconnecting my lines from my joists and having only 3' worth of exit line in the basement before going through my basement and out at a downward angle into that 8" drain pipe. :) Looking forward to it, too! Ha.