Пікірлер
@kunsahaho607
@kunsahaho607 2 жыл бұрын
How and from where to get the pseudo potentials suitable for optical property calculations? which type of potentials are to be used?
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
What I have shown is just for illustrative purposes, you have to do some literature search for using the best pp possible for the material concerned.
@Dino-kq1hz
@Dino-kq1hz 2 жыл бұрын
How did you incorporate the "GGA-PBE" Exchange correlation in your input file? I can see "input_dft='pbe'" ---> Does this mean "GGA-PBE" exchange correlation is incorporated?
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
You have to set input dft to pbe and also choose the correct pp for use with the input dft specified.
@priyambadaaiswarya1831
@priyambadaaiswarya1831 2 жыл бұрын
Sir , can you tell me how to calculate Refractive index
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
If you plot the real part of dielectric function, its value at w=0 can be approximately taken as dielectric constant.
@priyambadaaiswarya1831
@priyambadaaiswarya1831 2 жыл бұрын
Hello Sir can we use K-points {tpiba_b} for the calculation?
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
Yes you can. Please refer to the manual.
@alicanguler4761
@alicanguler4761 2 жыл бұрын
Thank you so much , well-appreciated
@zahidurrahaman428
@zahidurrahaman428 2 жыл бұрын
Thank you for this series of incredible videos. Keep up the good work professor.
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
Not a professor, but thanks for your wishes and appreciation. ☺️
@zainabm809
@zainabm809 2 жыл бұрын
Thanks a ton! Its not this simple when others explain these subjects . Keep the good work please
@kapilmandal2857
@kapilmandal2857 2 жыл бұрын
Sir, can you please discuss on how to get the pressure dependent bandstructures for high pressure calculations?
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
I suggest you create structures with different applied pressure (you have to calculate specific to your cell) and simulate them. You can try the Materials Square builder for the same.
@puteriintanzulaikha9477
@puteriintanzulaikha9477 2 жыл бұрын
Hi sir, may I know how can I get the HOMO and LUMO? What parameter is corresponding to HOMO LUMO ? thank you
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
Can you elaborate little more? Do you want to plot the states, as in an iso surface? Or just want to print the values in the output? If latter then set the nbnd flag accordingly and the HOMO and LUMO values would be printed in the out file.
@puteriintanzulaikha9477
@puteriintanzulaikha9477 2 жыл бұрын
@@matsci-etalks5994 the latter. how to determine the value for nbnd? is there any range?
@puteriintanzulaikha9477
@puteriintanzulaikha9477 2 жыл бұрын
Hi sir, may I know how can I get the HOMO and LUMO? What parameter is corresponding to HOMO LUMO ? thank you
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
Usually depending on the material (metal/ insulator etc) you need to choose appropriately. Google it a bit, consult the manuals and choose according to your system.
@prabhakarolichannel9747
@prabhakarolichannel9747 2 жыл бұрын
next types of PP and their use in flags and in cards........waiting to see
@priyambadaaiswarya1831
@priyambadaaiswarya1831 2 жыл бұрын
Sir for ibrav=0 , how to set CELL_PARAMETERS{alat}
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
Read the manual for more details. Also you can try using PWGui for ease of setting these and etc.
@deepaksingh3460
@deepaksingh3460 3 жыл бұрын
How do you update the atomic positions after running the vc-relax calculations. Do you also need to update the atomic positions for a nscf calculation following scf? What output files of a vc-relax calculation are used for a scf calculation?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Manually you have to search final co ordiantes after relax calculation from output and use those for further scf or nscf calculations that you want to do.
@priyambadaaiswarya1831
@priyambadaaiswarya1831 3 жыл бұрын
Sir how to choose k- points
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Rule of thumb is for bulk its nxnxn for 2d nxnx1 for 1d (c axis oriented say) 1x1xn
@hennamalakar2380
@hennamalakar2380 3 жыл бұрын
Sir, I'm having problem to run the scf calculation. It says command: pw.exe -in espresso.in. can you help me to solve this?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
This could be an installation related issue, some packages/ libraries may be missing, kindly see the manuals. I am not sure what exactly the error message is.
@happyworld1849
@happyworld1849 3 жыл бұрын
Nice initiative. Do you have pdos calculation guidelines?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Sorry not in the present tutorial no. But you an see the Espresso manual, it's not complicated.
@mohammadubaid6240
@mohammadubaid6240 3 жыл бұрын
Sir ELF calculation is missing. Could please share the information of pp.elf.in?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
I give you a hint Just a simple change of a flag setting in the pp.x input. Google it.
@prabhakarolichannel9747
@prabhakarolichannel9747 3 жыл бұрын
got idea about cards and flags.but in celldm(1)=.................do. why do?what is this?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Not do its d0 (zero) indivates power , like 3.0d0=3.0 !
@mishmash4524
@mishmash4524 3 жыл бұрын
Thank you so much for your content. All your videos are beneficial. I have a query, though. I'm trying to reproduce results obtained from a paper. Among other parameters used to build their cell, they have written: 'four-layer slab was used with the atoms in the bottom two layers were fixed to their bulk positions ' Can you please help me accomplish this using BURAI?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
You can try use some simpler builder like Materials Square.
@sumansarkar6984
@sumansarkar6984 3 жыл бұрын
Sir, the video very helpful. Can you tell me how to chose at which value of isovalue should plot Charge density, ELF.
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
It's your choice how you want to show it, but mention the value in graphs.
@priyankaroy6804
@priyankaroy6804 3 жыл бұрын
Hello sir, thank you for making such videos. Can u please tell how to get bond length n angle using burai software. Please respond 🙏.
@matsci-etalks5994
@matsci-etalks5994 2 жыл бұрын
Try xcrysden or Avogadro for such measurements.
@Adam-nd8vd
@Adam-nd8vd 3 жыл бұрын
A bit off topic, but we shouldn't use the same k-path for band structure and DOS. DOS requires a larger grid than the scf calculation.
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Yes that's correct, DOS involves more points, but I am giving just a demonstration and have mentioned that verbally in one of the videos. If you see the optical spectra also I am showing example with a small no. of bands. All this is because I was stuck on a off the shelf Desktop PC, so and again and again I mention viewers these are for illustrative purposes, actual calculations are much more computationally demanding. But I don't have the adequate resources for making this tutorial.
@alvy_._ahmed
@alvy_._ahmed 3 жыл бұрын
hello sir, hope youre doing well. May i Know your computer specification? Are you running this on a virtual machine?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
No it's not virtual machine, just a Desktop, but I say again and again these are for illustrative purposes only and real precision calculations would require a very powerful workstation or preferably a cluste for larger systemsr.
@priyankaroy6804
@priyankaroy6804 3 жыл бұрын
Thank you so much sir🙏🙏🙏🙏🙏
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Most welcome. Share with friends and subscribe.
@muhammadsherazkhan2903
@muhammadsherazkhan2903 3 жыл бұрын
Hello sir. I have some problem. when i finish my band calculation. so i dont have dat.gnu file. i have only band.dat file. but dont get dat.gnu.
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Hmm I am not sure why that's happening, you can convert into gnu format or for more control over the kind of output files consult the manuals. I am just giving an introductory tutorial, there are many more things that one can do.
@yomoenterprises2407
@yomoenterprises2407 3 жыл бұрын
Excellent sir.
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Most welcome. Do share and subscribe.
@mekrajavel718
@mekrajavel718 3 жыл бұрын
Really impressed 👍
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Most welcome. Do share and subscribe.
@darshilchodvadiya7572
@darshilchodvadiya7572 3 жыл бұрын
This tutorial is very informative and useful. Sir, can you make a tutorial on absorption spectra, refractive index, excitation coefficient?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Absorption may be calculated from dielectric fn with a simple relationship. You can do it with some literature search.
@nagarjunapatra9516
@nagarjunapatra9516 3 жыл бұрын
can i do soc scf calculation in burai ? i am not able to download full relativistic pseudopotentials into the burai. please help me regading the problem
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Sometime there's a problem with the proxy server if any. Otherwise it should download. Consult the Burai manual.
@sushreepaikray447
@sushreepaikray447 3 жыл бұрын
Sir how did you make the input files that you have saved in the calculation file?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
You can use text editor to manually do it, or PWgui.
@oxanarubinkovskaya6459
@oxanarubinkovskaya6459 3 жыл бұрын
Thank you much! Could you share the calculation files of MoS2?
@priyambadaaiswarya1831
@priyambadaaiswarya1831 3 жыл бұрын
Sir I have both quantum espresso 6.4.1 & qe 6.7 . I want to remove 6.4.1. how to do it sir??
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Google how to uninstall a program in linux. It's simple.
@guruprasadg1097
@guruprasadg1097 3 жыл бұрын
Dear Sir, Great work and very informative. Please make a continuous video by running one quantum espresso example on HPC.
@devkumarthapa8234
@devkumarthapa8234 3 жыл бұрын
Sir could you tell me what configuration of computer should we buy for electronic. optical and magnetic calculation of nanocrsytals
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Materials Science calculations typically need clusters, if you want to do only unit cell electronic properties calculation, get a high end workstation.
@learnwithme3517
@learnwithme3517 3 жыл бұрын
thank you sir for this wonderful explanation
@thilakpeiris3252
@thilakpeiris3252 3 жыл бұрын
Thank you very much, well explained and detailed.
@kriteshgupta7380
@kriteshgupta7380 3 жыл бұрын
Thank you Sir, your content is so good for the beginners like me. Please do make one video on modelling twisted bilayer graphene using the CIF files available on the web.
@HIRENP
@HIRENP 3 жыл бұрын
Sir, Thank you for this great explanation , keep it up. Nice video
@bradoquethomassales9645
@bradoquethomassales9645 3 жыл бұрын
Cara, muito obrigado por ter gravado esses tutoriais. Meus parabéns pelo trabalho, e bela iniciativa a sua!
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Obrigado!
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
Thank you for this valuable information. Could you please do a video on Nudged Elastic Band (NEB) calculations?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
I will was busy with some work, and don't have much computational resources these days. But it is in preparation.
@ghiyasanwar3439
@ghiyasanwar3439 3 жыл бұрын
👏👏👏👏👏👏👏👏👏😊😊😊😊😊😊😊😊 Keep it dear doing outstanding
@danikivines2388
@danikivines2388 3 жыл бұрын
Good Work Sir, Are you working on the phonon calculations?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Yes, soon
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
Hai sir, Again, very informative video. Recently, I have read one article in computational material science journal named “High-throughput electronic band structure calculations: Challenges and tools”. It contains the information of high symmetry k-points path for all crystal types. Is it reasonable to go with the whole path or could you please suggest the acceptable path in research publications for rhombohedral cell?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Hint: You have to check in a material (and or structure) specific way from highly cited literature in the field. Also what you are looking for matters (say uniform / non-uniform strained systems). Sometimes you would need surface plots of CBM and VBM.
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
Hai sir, Could you please elaborate more on the tag named “vdw_corr = ‘dft-d3”?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
It is a van der Waals correction scheme DFT-D3 to include vdw interactions in the calculations.
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
Dear sir, It is really helpful. Is it similar to the charge density plots (2D) published in research articles ?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
For research article depending upon systems more finer calculations maybe needed, e.g. more k points, higher cutoff after doing convergence tests. These are just to get beginners started.
@estebanguerrero682
@estebanguerrero682 3 жыл бұрын
Thank you so so so much for this video ❤️❤️❤️
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Glad it was helpful!
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
Dear sir, Thanks again for the information. Do we need to do structure optimisation (relax or vc-relax) before DOS ?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Best sequence to follow relax/ vc-relax before any scf calculation. Make sure the scf converges. Then sometimes you can do a nscf as well before calculating DOS.
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
This video is so nice. I have subscribed your channel. Will share these videos for sure. May I know which smearing (fermi-Dirac or mv) is good for semiconductors like BaTiO3 calculations.
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Again depends upon the materials, do some literature survey and find out the best for metallic, non metallic , semiconducting systems.
@SantoshKumarBehara
@SantoshKumarBehara 3 жыл бұрын
Dear sir, Thank you so much for the informative content. I am really glad to learn all these basics. Definitely, I will go through all your videos. As a beginner in DFT, I have some doubts after this video. Could you please respond to my comments? 1. What is the no. bands accepted in DOS for the research publication? 2. In the output file of BAND, I have seen nscf log file. What is the difference between scf and nscf files?
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Use a high number of bands for DOS , also if you want optical calculation a high number of bands depending on the system is prescribed.
@lannaemilli6241
@lannaemilli6241 3 жыл бұрын
Hello, thanks for the very useful content!
@matsci-etalks5994
@matsci-etalks5994 3 жыл бұрын
Glad it was helpful!