Efficiency Improvement Dampers
58:59
What Makes Us Unique ?
40:28
Жыл бұрын
Fired Heater Nomenclature
11:11
2 жыл бұрын
Frequently Asked Question
12:14
2 жыл бұрын
Frequently Asked Question
9:26
2 жыл бұрын
Пікірлер
@fatimapakarab
@fatimapakarab 27 күн бұрын
thanks, wonderfull explanation ..
@idrissbecheket6897
@idrissbecheket6897 3 ай бұрын
Excellent, thank you so much.
@idrissbecheket6897
@idrissbecheket6897 3 ай бұрын
So useful, thank you for sharing.
@muhammadnurulhakim9328
@muhammadnurulhakim9328 4 ай бұрын
thank you very much. It is quite informative.
@deeppatel034
@deeppatel034 5 ай бұрын
Can you please provide Excel sheet for combustion calculations?
@ahmedelmosrati4201
@ahmedelmosrati4201 6 ай бұрын
Dear Sir, I watched your video on KZbin, and it is very nice. In our gas plant ,we have Vertical Cylindrical natural draft fired gas heater. Tube design temp is 350 C, temp at the inlet of convection zone is 700 C Convection zone consist of 7 rows, first three rows from bottom to top is non-finned tubes. The rest from 4 to 7 are finned tubes. We have repeated failures in the convection zone, most tubes fails are at the fourth and fifth rows. The heater is working for regenerating the molecular sieve of the gas dryers, so it is working cyclic , 5 hours heating and then off 3 hours. At the end of heating the burners shut off and fuel cut off inside tubes at the same time while the temp at the inlet of convection tube is 700. The questions are : - Do you think the temp of the tube metal increase at moment of closing the valve of the gas inside the tubes while flue gases temp inside the heater is 700 C causing the tube failure? Is it a good idea to keep , the gas flowing inside tube after shutting off the burners to protect the tubes from flue gases high temp? - Why we have repeated failure at the first 2 rows at the finned tubes in the convection zone? Is because of the design ? Here is the design of finned tubes: Location First put in service Number of failures Fins Dimensions: Spacing (fins/m) Height (mm) Thickness (mm) MCX 2006 11 197 25.4 1.5 API560 : 197 (MAX) 25.4 (MAX) 1.3 (MIN)
@FurnaceImprovementsServices
@FurnaceImprovementsServices 5 ай бұрын
Please feel free to reach out with your questions at [email protected]
@Shah-Jay
@Shah-Jay 7 ай бұрын
Well done. Thanks
@huyninh6580
@huyninh6580 8 ай бұрын
Thank you for useful information
@ahmedaleshi1249
@ahmedaleshi1249 8 ай бұрын
Hello Sir, Thank you for sharing your knowledge. I have a question about the sag of an A-106 Gr B crude oil heater pipe. Can you help me understand what might cause it? Thank you.
@vilaskoleshwar4552
@vilaskoleshwar4552 10 ай бұрын
Hi Ashutosh, I was EIL employee working in Process department and reporting to MK Joshi. I remember you were very well, You were a "GO TO PERSON" for any design issues of Heaters. Glad to see you online sharing your vast knowledge in the field of Heaters, Combustion equipment. Best of Luck. Hope to meet you one day.
@SawenJamil
@SawenJamil 10 ай бұрын
Most beatiful video! which each software you draw this fired heater please?
@RES-Marlon
@RES-Marlon 10 ай бұрын
excellent video.
@binoyjacob5811
@binoyjacob5811 11 ай бұрын
Hello Sir, i just wanted to ask you how did you calculate the tube circle diameter ( D) (44:40)
@JAMES-k8m8i
@JAMES-k8m8i 11 ай бұрын
Thank you for your great lecture. I hope this continues. from korea
@silentwalk9925
@silentwalk9925 Жыл бұрын
Can we get help in design experemtal effective SMR catalyst cahmber?
@onel276
@onel276 Жыл бұрын
Can you share some reference books???
@rasoolniknamfar4388
@rasoolniknamfar4388 Жыл бұрын
Thank you so much for sharing your knowledge You are great Is there next sessions? Like convection?
@balasubramanian8738
@balasubramanian8738 Жыл бұрын
Fabrication and erection procedure of fired heaters in refinery
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
You can get information about fabrication and erection procedures from API-560 and several other documents on the web.
@balasubramanian8738
@balasubramanian8738 Жыл бұрын
How much manpower us required for fabrication of fired gas heaters at shop and manpowers for erection at site
@balasubramanian8738
@balasubramanian8738 Жыл бұрын
How about doing cost estimation for design supply and erection of fired heaters sir
@hieutranminh7559
@hieutranminh7559 Жыл бұрын
Highly be grateful to you Sir
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
Thanks
@nikhildiwan1013
@nikhildiwan1013 Жыл бұрын
Hi, I work at Santura Engineering in Mumbai and we have been manufacturing and exporting Metallic Anchors since 20 years. Can you plz give us insights on anchors relating to problems that might be faced during installation or with quality of anchors. We’d like to improve our quality.
@viettankhuu4668
@viettankhuu4668 Жыл бұрын
@19:50, approach equilibrium, can I understand the exit gas temperature is the actual outlet temp?
@mukundkapadia2163
@mukundkapadia2163 Жыл бұрын
How can we control the increasing CPR and coking rate We operating induced draft furnace for ethane and propane cracking??
@bindiberry6280
@bindiberry6280 Жыл бұрын
One carbon can actually compress four hydrogen into methane which are very economical, and requires very little energy because they are usually, biologically and/or naturally formed on Earth.
@AREZKIBOUGARECHE
@AREZKIBOUGARECHE Жыл бұрын
I am very thankful for all your efforts. I have benefited a lot, may God bless you.
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
Thanks
@faisaljummal8101
@faisaljummal8101 Жыл бұрын
Do you made video for Ethane Cracker furnace ?? . Plz reply me
@ziabashir
@ziabashir 2 жыл бұрын
Gas Turbine exhaust mass flow has temperature above 400 deg C, can it be used instead of firing fuel ? Kindly advise
@ziabashir
@ziabashir 2 жыл бұрын
Dear Sir, do you advise Exhaust heat flow from Gas turbine can be use to get temperature
@ziabashir
@ziabashir 2 жыл бұрын
very informative for me
@debjitsahoo2557
@debjitsahoo2557 2 жыл бұрын
Why Quench oil is not used to quench the crack gas in the Ethane & Propane Recycle Furnace??
@maljones3802
@maljones3802 2 жыл бұрын
Thank you for the videos it was crystal clear for me and gave me brilliant insight at a summary level
@madhusudantapadia3957
@madhusudantapadia3957 2 жыл бұрын
Awaiting for session 4
@ejazminhass614
@ejazminhass614 2 жыл бұрын
Great work,please also share session 3 part 3.....
@muzafarhussain9336
@muzafarhussain9336 2 жыл бұрын
It's urgent
@muzafarhussain9336
@muzafarhussain9336 2 жыл бұрын
Respected sir... I have need complete knowledge of furnace installation in fertilizer plants with complete details drawing
@samcool4u21
@samcool4u21 2 жыл бұрын
What about structural design and any consideration
@rochanimech
@rochanimech 2 жыл бұрын
Sir could you please upload session 4 on radiant design part-2.
@ChemEnggWisdom
@ChemEnggWisdom 2 жыл бұрын
How does orientation of tubes decided? Vertical vs horizontal tubes.
@fliprodriguez5250
@fliprodriguez5250 2 жыл бұрын
Footprint. Type and amount of fluid. Cost. Shipping. Are some factors in deciding orientation of tubes.
@ChemEnggWisdom
@ChemEnggWisdom 2 жыл бұрын
Great....
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
Thanks
@solomonaromada5111
@solomonaromada5111 2 жыл бұрын
Thank you so much for the insight. If you have a fuel gas fired heater (an auxiliary heater) where the intention is not to heat up another fluid but to generate a hot flue gas which is needed to increase the temperature of the stack, what are the most efficient measures one needs to apply to maximize the flue gas temperature (leaving the heater) while not excessively increasing emissions? The only means I can think of now is increasing the fuel gas and air supply, but this will also lead to increase in emissions. Thank you
@ChemEnggWisdom
@ChemEnggWisdom 2 жыл бұрын
How to get the lobo paper?
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
You can search on Google or Scribd website
@erdevendra
@erdevendra 2 жыл бұрын
Wonderful Session
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
Thanks
@CristobalGordillo
@CristobalGordillo 3 жыл бұрын
Dear Ashutosh, could you please confirm the aprox tube production capacity of 4500 scfh/tube?
@patelpunit1569
@patelpunit1569 3 жыл бұрын
Hamara ethylene cracking furnace he 800 c pe heat hota he
@patelpunit1569
@patelpunit1569 3 жыл бұрын
Hamra furnace 1998 ka model he pqe me cock nikal na bohat hard he
@Ratman_Bejo
@Ratman_Bejo 3 жыл бұрын
Vertical Thermal oil heaters
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
Thermal Oil heaters are built in both vertical and horizontal configurations.
@amiteshg5959
@amiteshg5959 8 жыл бұрын
Great Work! Keep it up!!
@FurnaceImprovementsServices
@FurnaceImprovementsServices Жыл бұрын
Thanks Amitesh