Пікірлер
@ramcity05
@ramcity05 4 күн бұрын
Nice 👍
@skyfirephoenix8716
@skyfirephoenix8716 4 күн бұрын
Isn’t all of that shown; spray foam?
@InsulationMachines
@InsulationMachines Күн бұрын
@@skyfirephoenix8716, this contractor does both. These are videos he provided.
@Nick84924
@Nick84924 8 күн бұрын
Big time help. Insulating my garage. Are gloves and a mask necessary?
@djfglobal3377
@djfglobal3377 4 күн бұрын
I absolutely use an N-95 . I (also) absolutely do not want any fiberglass fibers in my lungs . Also I wear gloves because I in general try try to limit my contact in addition to washing hands as often as possible. A TON of guys do not wear mask or gloves but that is their own comfort level. Before I had a strong negative air machine or whenever I do not have one handy -for any particle creating activity I try to at least have a box fan or two blowing out the window(s)- sawdust, concrete dust, insulation, drywall/plaster etc. In addition to sealing a door with tape or putting up a plastic wall. Ps - this video is the correct way to install fiberglass batts in my opinion
@hyperroofing
@hyperroofing 22 күн бұрын
The cost
@InsulationMachines
@InsulationMachines 22 күн бұрын
Call me 810-614-0072
@zeddtbear
@zeddtbear 23 күн бұрын
Use rockwool dont be cheap
@InsulationMachines
@InsulationMachines 23 күн бұрын
@@zeddtbear, Rockwool is a great material. I’ve used it for my own builds but not everyone wants it.
@zeddtbear
@zeddtbear 23 күн бұрын
That shit is garbage.
@NANCYB004
@NANCYB004 24 күн бұрын
Thank you😊 I'm Here to Learn How to Build and Insulate my 1st and Very own Home I Appreciate your Knowledge Sir
@InsulationMachines
@InsulationMachines 23 күн бұрын
@@NANCYB004, thanks for watching!! I’m glad it was a help to you.
@MusikGalalau
@MusikGalalau 27 күн бұрын
What about if I'm insulating my basement’s ceiling? Should I use the same technique?
@InsulationMachines
@InsulationMachines 26 күн бұрын
Just use unfaced fiberglass. Be mindful that if you insulate your basement ceiling, the floor above will will not benefit from the radiant transfer of heat in the winter (if you are in a very cold climate).
@patrickh5801
@patrickh5801 29 күн бұрын
Stapling it to the inside of the studs does not create a vapor barrier and this way will not pass code unless you put plastic over the whole wall.
@InsulationMachines
@InsulationMachines 28 күн бұрын
This is a recommended install by the manufacturer. Adding an additional plastic over the facing creates a double vapor barrier. You would need to use unfaced material if you use plastic.
@djfglobal3377
@djfglobal3377 4 күн бұрын
Also , how will your drywallers glue the drywall to the studs? Do you not use glue ? If your guys are using a screw every 6 “ or 8 “ on walls you can insulate with the tabs in the face of the studs but only on walls . Should typically still glue ceilings . I comment respectfully , thanks
@bklynkahmel1
@bklynkahmel1 Ай бұрын
Can you please post the link to where we can find the generator box.
@InsulationMachines
@InsulationMachines Ай бұрын
@@bklynkahmel1, you can order it through us. Give me a call at 810-614-0072. Thanks for watching!
@InsulationMachines
@InsulationMachines Ай бұрын
The vacuum bag in the video was only 6 months old. It was stored in a shop near a garage door which allowed it to be in direct sunlight for hours at a time. It was in the very hot Southeastern United States. Conditions definitely were not ideal and it didn’t take long for it to disinegrate. Bags also do not like cold weather.
@jladybug2647
@jladybug2647 2 ай бұрын
That machine is awesome!
@InsulationMachines
@InsulationMachines 2 ай бұрын
@@jladybug2647 It’s a game changer for insulators for sure. Thanks for watching.
@Hardawayfits
@Hardawayfits 2 ай бұрын
No ppe? 😮
@InsulationMachines
@InsulationMachines 2 ай бұрын
Not required. Difficult to speak clearly for the camera with a mask.
@samtheman1766
@samtheman1766 2 ай бұрын
It looks like a lot of material waste on the floor 😮
@InsulationMachines
@InsulationMachines 2 ай бұрын
Thanks for watching! Actually, that is all vacuumed up and recycled into the machine, then sprayed into the wall.
@samtheman1766
@samtheman1766 2 ай бұрын
@InsulationMachines got it. Thanks 👍
@lasthustlerstanding2660
@lasthustlerstanding2660 2 ай бұрын
Isn't it very itchy?
@InsulationMachines
@InsulationMachines 2 ай бұрын
@@lasthustlerstanding2660, fiberglass can be. This is cellulose. Thanks for watching!
@bishowbhandari1601
@bishowbhandari1601 3 ай бұрын
What is the price?
@InsulationMachines
@InsulationMachines 3 ай бұрын
@@bishowbhandari1601, please give me a call at 810-614-0073 to discuss pricing. Thank you for watching!
@Turkalicious1388
@Turkalicious1388 3 ай бұрын
Thank you for sharing very useful information!
@InsulationMachines
@InsulationMachines 3 ай бұрын
@@Turkalicious1388, thank you for watching.
@kenneth2516
@kenneth2516 3 ай бұрын
Good explain thanks good find this video
@InsulationMachines
@InsulationMachines 3 ай бұрын
@@kenneth2516, glad it helped! Thanks for watching.
@mikechan2044
@mikechan2044 3 ай бұрын
Is this diy able?
@InsulationMachines
@InsulationMachines 3 ай бұрын
IF you have a blower that can achieve 3.5 psi for cellulose or 2.5 for fiberglass. A rental machine usually is not maintained (having good airlock seals) to reach those psi levels. The process IS doityourself if you have good equipment
@mikechan2044
@mikechan2044 3 ай бұрын
@@InsulationMachines thank you for that knowledge sir
@zenderxt
@zenderxt 3 ай бұрын
What size hole should you typically need to cut in the drywall to get the hose in the wall? Is 3" enough?
@InsulationMachines
@InsulationMachines 3 ай бұрын
Yes. 3" hole is pretty standard. Use a 2" hose
@zenderxt
@zenderxt 3 ай бұрын
@@InsulationMachines Thank you very much!
@utrx908
@utrx908 3 ай бұрын
Only R-13 for between garage and the house, u guys must have some pretty warm weather year round, especially with the water lines there too
@InsulationMachines
@InsulationMachines 3 ай бұрын
Excellent point! This is zone 3. What is not shown in this particular video is that I put the insulation behind the water lines so they are kept to the inside of the house.
@jaimecardenas2033
@jaimecardenas2033 4 ай бұрын
Using wrong R value in the knee wall ,should be a least R 19 not R 13,I know he’s showing how to install it.
@InsulationMachines
@InsulationMachines 4 ай бұрын
R-13 is what code calls for in 2x4 wall.
@iseward01
@iseward01 2 ай бұрын
Code can vary from area to area, and colder climates require more insulation
@mikelangford1835
@mikelangford1835 4 ай бұрын
Bye
@opana4353
@opana4353 4 ай бұрын
The connectors might be in the box labeled CONNECTORS
@thedone1342
@thedone1342 4 ай бұрын
Dewalt has a real nice hand stapler not a whole lot of pressure you need to put into it unlike the silver ones feel like a dam hand gripper
@Turkalicious1388
@Turkalicious1388 4 ай бұрын
The heat from the foam expanding and the heat in attic gets to a toasty 160 degrees! Rolling the 500 pounds of open cell and hardener barrels up the trailer, the spray gun getting clogged, the hot ass suits, your mask getting fogged up, and pump problems are a challenge, but I love it! This is in Florida!
@InsulationMachines
@InsulationMachines 4 ай бұрын
Florida heat! Not for the weak!!
@MississippiMudMX
@MississippiMudMX 4 ай бұрын
do you have a full install? and a link to buy the door ?
@InsulationMachines
@InsulationMachines Ай бұрын
@@MississippiMudMX, I’m sorry that we are just now seeing this. You can buy the door through us. Give us a call at 810-614-0072. Here is a link for the install: kzbin.info/www/bejne/gGaYnI2lmKulbrssi=i0uVKRYF4DSEE-Da.
@jaimemaldonado7120
@jaimemaldonado7120 4 ай бұрын
No, you're correct. That's the way it's installed. I guess what I'm saying is the water to mixture ratio is a little offc
@InsulationMachines
@InsulationMachines 4 ай бұрын
@@jaimemaldonado7120, no. It went in perfectly. We have a video showing the moisture content on this very wall.
@jaimemaldonado7120
@jaimemaldonado7120 4 ай бұрын
Thos guy had no clue what he's doing. 😮
@InsulationMachines
@InsulationMachines 4 ай бұрын
@@jaimemaldonado7120, hmmmm. That’s exactly how you apply wall spray to an interior wall.
@onjofilms
@onjofilms 4 ай бұрын
I heard these machines suck.
@InsulationMachines
@InsulationMachines 4 ай бұрын
@@onjofilms, yes they do but they are supposed to!! Best vacuums in the business. Thanks for watching.
@jessecota6639
@jessecota6639 4 ай бұрын
What has more suction power, the 37hp or two 22hp Honda vacuums daisy chained?
@InsulationMachines
@InsulationMachines 4 ай бұрын
The 22s daisy chained have 48" water column compared to 35" on CoolVac37. HOWEVER, the CFM on 22s daisy chained is lower (3800cfm) compared to the CoolVac37 (5,000cfm) Daisychained 22s get more suction but move less material.
@Cruiser777
@Cruiser777 4 ай бұрын
That's right Safety First😅
@InsulationMachines
@InsulationMachines 4 ай бұрын
@@Cruiser777, 100%. Thanks for watching!
@robertkollasch2473
@robertkollasch2473 5 ай бұрын
How much is the rig?
@InsulationMachines
@InsulationMachines 5 ай бұрын
@@robertkollasch2473, call me at 810-614-0072 to discuss pricing.
@blitzdab8940
@blitzdab8940 5 ай бұрын
What a pointless video
@InsulationMachines
@InsulationMachines 5 ай бұрын
@@blitzdab8940, and yet you watched it and helped extend our reach. Thanks!
@reubenjohnson9868
@reubenjohnson9868 5 ай бұрын
I have the same insulation machine and it pushes out the material, but at the same time whoever is loading the hopper keep shooting back out could you tell me what’s wrong with it
@InsulationMachines
@InsulationMachines 5 ай бұрын
You need new airlock seals. If you use your machine daily, change the seals 2x a year. Seals are here: insulationmachines.net/product-category/airlock-seals/
@ExtinctInsanity
@ExtinctInsanity 6 ай бұрын
Yeah, they said that about asbestos, too...
@InsulationMachines
@InsulationMachines 6 ай бұрын
@@ExtinctInsanity, thanks for watching.
@bigstar111
@bigstar111 6 ай бұрын
Why is the kraft paper to the ouside?
@InsulationMachines
@InsulationMachines 6 ай бұрын
@@bigstar111, we were in a climate in which the vapor barrier has to be towards the living space.
@HundoFishing
@HundoFishing 2 ай бұрын
sidewalls paper facing towards u on underfloors aka crawl spaces paper goes facing the house
@HundoFishing
@HundoFishing 3 күн бұрын
@@bigstar111 paper always goes towards living area
@dertyjerz3
@dertyjerz3 7 ай бұрын
Thank you sir
@alejandrogazu6705
@alejandrogazu6705 7 ай бұрын
This guy is a beast!!!! Nice job!
@InsulationMachines
@InsulationMachines 7 ай бұрын
@@alejandrogazu6705, he’s one of the best and that’s really how he works.
@InsulationMachines
@InsulationMachines 7 ай бұрын
Thanks for watching!
@kennethclark9196
@kennethclark9196 7 ай бұрын
Very helpful! Thanks
@InsulationMachines
@InsulationMachines 7 ай бұрын
Glad it helped! We have an entire playlist on KZbin dedicated to changing our airlock seals. Thanks for watching.
@ameritech1534
@ameritech1534 7 ай бұрын
Wow, very good 👍 I need more information ?
@InsulationMachines
@InsulationMachines 7 ай бұрын
Give me a call at 810-614-0072.
@dalelelesands6888
@dalelelesands6888 7 ай бұрын
Please be careful around the hvac equipment. Shitty blown insulation like this really makes my job a LOT harder when it’s blown into the wrong areas.
@InsulationMachines
@InsulationMachines 7 ай бұрын
Thanks for watching! We have a video about that very subject.
@exploreeverything0.1
@exploreeverything0.1 7 ай бұрын
What a good content. I love this content. But I am a little disappointed about your video views. I see your subscription number is huge but according to your subscribers, you have less views. I think it disappointed me and you too. I see your channel has many problems. One of the problems is, you haven't used any tags in your video tag section. Without tags, your videos won't be seen by many people so you won't get many views and your business won't grow through KZbin. You know KZbin is the best platform to promote your business. How will you promote your business if you don't get in front of people who need installation machines? I am a KZbin expert I know how to get more views from a video according to your viewer's location. I have a plan for your channel. If you are interested email me at: [email protected]
@dustinmccollum7196
@dustinmccollum7196 7 ай бұрын
Look ive spent years working outside in fl heat. You dont just lose water when sweating. So you cant just drink water. You need Electrolytes and a some salt.
@InsulationMachines
@InsulationMachines 7 ай бұрын
You are absolutely correct but since we are not doctors, we really can’t recommend more than water. My wife was an educator and couldn’t recommend or apply sunscreen to students so we’re being careful. Hopefully, others will see your comment or maybe we can add an “Here’s what I do,” type of video. Thanks for watching and for getting us thinking harder about this.
@dustinmccollum7196
@dustinmccollum7196 7 ай бұрын
@InsulationMachines This is just me but the days I drink only water I'm struggling in the heat. My regular routine is I drink two of the Gatorade electlytes and water throught out the day. My company also provides us with water mixers two.
@InsulationMachines
@InsulationMachines 7 ай бұрын
@@dustinmccollum7196, that’s great and we definitely hear you on that. Great that the company provides the water also. We’ve seen a few that do that. You can’t be too careful in this heat.
@dylanlathrop9837
@dylanlathrop9837 7 ай бұрын
Im itching just looking at that stuff
@InsulationMachines
@InsulationMachines 7 ай бұрын
It does bother some people.
@celinaschorkmayr
@celinaschorkmayr 8 ай бұрын
Oughhh, I really need this vacuum cleaner to our kids room, it’s just sucking up everything😈🙈
@InsulationMachines
@InsulationMachines 8 ай бұрын
Lol!
@mattkesler871
@mattkesler871 9 ай бұрын
What would be the recommended lengths of each section 3”..2”..and wall tube?
@InsulationMachines
@InsulationMachines 9 ай бұрын
Minimum of 100 feet from machine. I would transition this way: 100' of 3" to 50' of 2" then to your wall tubing
@BurkesBucknFirewood
@BurkesBucknFirewood 9 ай бұрын
Nice!
@InsulationMachines
@InsulationMachines 9 ай бұрын
Thanks for watching!
@ffk3730
@ffk3730 9 ай бұрын
How many bags per hour?
@InsulationMachines
@InsulationMachines 9 ай бұрын
The standard CM1500: 2,200 pounds/hour of cellulose and 900 pounds/hour of fiberglass The CM1500HP: 3,000 pounds/hour of cellulose and 1,200 pounds/hour of fiberglass Thanks for watching! You can call me at 810-614-0072 if you have any questions.
@ffk3730
@ffk3730 9 ай бұрын
@@InsulationMachines thank you so much for your response, Mr
@InsulationMachines
@InsulationMachines 9 ай бұрын
@@ffk3730, your welcome!
@LegBreakMMA
@LegBreakMMA 9 ай бұрын
Nice set u0
@InsulationMachines
@InsulationMachines 9 ай бұрын
Appreciate the comment! Thank you for watching.