CHILLER BASIC KNOWLEDGE
4:57
2 ай бұрын
Пікірлер
@jollyscaria1922
@jollyscaria1922 26 күн бұрын
How do you setup an air-conditioning systom for heating?Someair condiniong systom using aetin foe heating afteraexueingrhe refeigerting systteimoutlinedabovethwre areonlya fewsetpsin perparingforheating checkthefiltersto seethatthwyarw area cleansetthae manualoutside air dampertothewinter posistriin most systim are designed ro usekwssoutside airinwibterthaninsumwr dont vlocktheauti maric damperro accomplishrhisas it will damges the motor xheckthe thw steon supplyand condenstatereturn line forrightess settgecontrols forheating andseethatthe trformer thermostand setoms valveopertporpwrrtly follw allrhes aetupa rwlugioualt and touer air condirioning systom...
@jollyscaria1922
@jollyscaria1922 26 күн бұрын
Filter dir strner frdge using ac dire using lquked line using fixing defrnt typeusing oil block come dx uint split ac packeg using big unig using flier core using chiller filter depndofsystom using must be ok
@jollyscaria1922
@jollyscaria1922 26 күн бұрын
Fiter dier filtszihion system filing gas durs t filter gas block come usinfilter dier using mostering block ing chickup come winding systeom slfty exfanshioning
@prakashgotame8875
@prakashgotame8875 Ай бұрын
Suction close karne jaruraat naii hota haii sir
@hvactraining22
@hvactraining22 Ай бұрын
Suction nahi close kiya hai, kyuki evaporator me koi gas nahi to Suction close karne ki zarurt nahi
@saifibrar1298
@saifibrar1298 Ай бұрын
Process batao bhai
@md.shahid4305
@md.shahid4305 Ай бұрын
अगर चिल्ड वाटर और सप्लाई लाइन में प्रेशर सभी जगह बराबर और एक या 2 जगह पर काम हो तो क्या बात हो सकती है। जैसे की सभी जगह पर 5 बार का प्रेशर है इनलेट और आउटलेट मगर यही प्रेशर दूसरे जगह पर 5 बार से कम है तो क्या करना चाहिए।
@hvactraining22
@hvactraining22 Ай бұрын
दूसरे लाइन जो chilled water के मेन लाइन से निकलते उसके वाल्व को चेक करेंगे कि वाल्व fully open hai या नहीं
@md.shahid4305
@md.shahid4305 Ай бұрын
@@hvactraining22 वाल्व ओपन है सर फिर भी प्रेशर कही कम कहीं ज्यादा है।
@hvactraining22
@hvactraining22 Ай бұрын
कोई strainer तो नहीं लगा है लाइन में?
@md.shahid4305
@md.shahid4305 Ай бұрын
@@hvactraining22 नही प्राइमरी पम्प का प्रेशर डाउन हो गया था कारण था चिल्लर पाइप में पानी नही होना पाइप में पानी कम होने की वजह से प्रेशर डाउन हो गया था अब प्रेशराइजेशन पम्प को ऑन करते ही जब भर गया तब प्रेशर सही दिखाने लगा। वैसे आपका भी शुक्रिया बताने के लिए।
@mrfaizu637
@mrfaizu637 Ай бұрын
Subcooling exv me hota 😢
@nurulhodasiwan3663
@nurulhodasiwan3663 2 ай бұрын
kzbin.info/www/bejne/pZ6tZ6CloJlln9U&pp=ygUdSG93IHRvIENhbGN1bGF0ZSBSZXF1aXJlZCBDRk0%3D
@nurulhodasiwan3663
@nurulhodasiwan3663 2 ай бұрын
Please don't misguide the viewers. Your CFM calculation is totally wrong. Kindly coordinate with HVAC engineer.
@hvactraining22
@hvactraining22 2 ай бұрын
Why what is the problem ?
@izsaza6271
@izsaza6271 Ай бұрын
How abt you shut up ? I dont find anything wrong here ? Kindly , YOU go and coordinate with the right HVAC engineer!
@umarfarooq584
@umarfarooq584 2 ай бұрын
HVAC technician booked ha
@dearfriends1659
@dearfriends1659 3 ай бұрын
ACH kaise pata chalega sir ki kitna lena hai
@hvactraining22
@hvactraining22 2 ай бұрын
Ye humare client ki requirement hoti hai , uske according hum ACH lete hain
@dearfriends1659
@dearfriends1659 2 ай бұрын
Thank you
@Engr-Hassanshehwarshah
@Engr-Hassanshehwarshah 3 ай бұрын
Sir kindly tell us how can come oil in compressor after that separate from oil separator
@hvactraining22
@hvactraining22 3 ай бұрын
Return oil they are coming from oil separator to compressor with oil pump
@TanwirQuamar-zs5su
@TanwirQuamar-zs5su 3 ай бұрын
Sir aap pahle kahi se proper training le apke liye aur apke viewers k liye achha hoga
@hvactraining22
@hvactraining22 3 ай бұрын
Kyu bhai kya samjh nahi aaya tumhe?
@izsaza6271
@izsaza6271 Ай бұрын
Half knowledge leke kisi ko judge kar rahe ho bhaiya , pehle tum acchi parhayi karlo .. aapke liye accha hoga
@dhanrajsonkar4111
@dhanrajsonkar4111 4 ай бұрын
loading unlaoding ka bhi issue ho sakta hai kya...low oil level to sure hai..
@budhram3944
@budhram3944 4 ай бұрын
Sir oil ka temperature kitna hotha hai
@hvactraining22
@hvactraining22 4 ай бұрын
110⁰F
@hamidjamal9658
@hamidjamal9658 4 ай бұрын
Bhai aap next vedio me isko sahi se samjhao maza nhi aaya
@gunjantiwari8858
@gunjantiwari8858 5 ай бұрын
R-134a ka su cooled temperature minimum and maximum ka range kitna hona chahiye water cooled Chiller m
@hvactraining22
@hvactraining22 5 ай бұрын
10 to 18 ⁰F
@jinenderthakur8116
@jinenderthakur8116 5 ай бұрын
How u r deciding ach ?
@hvactraining22
@hvactraining22 5 ай бұрын
We are not deciding they will give their's requirement on the basis of that we can decide.
@jinenderthakur8116
@jinenderthakur8116 5 ай бұрын
@@hvactraining22 but Mera puchna ye hai ki if client don't know or is there any standard ki air ko kitne baar change Krna hai
@hvactraining22
@hvactraining22 5 ай бұрын
@@jinenderthakur8116 area ke according iski requirement hoti hai, jaise ki hospital project hai ya hotel hai sab jagah ka alag hai ASHRAE iska standard hai
@ashokrawat9081
@ashokrawat9081 6 ай бұрын
Super explain.
@hvactraining22
@hvactraining22 6 ай бұрын
Thanks
@md.shahid4305
@md.shahid4305 6 ай бұрын
Motor move karke aasani se bhi belt change kiya ja sakta hai aur by the help screw driver also but last meri uungli dab gayi thi pulli me.
@hvactraining22
@hvactraining22 6 ай бұрын
Yess
@subratamajumder8180
@subratamajumder8180 6 ай бұрын
Economizer bol kar Heat Exchanger Samjha kiyu rahe Sir.. Flash gas ke bate me batao na..
@hvactraining22
@hvactraining22 6 ай бұрын
Different company ke chiller ka economizer different hota hai ye bhi ek type ka heat exchanger hi hota hai
@wakeelkhn
@wakeelkhn 6 ай бұрын
THANKS, PLEASE LET ME KNOW HOW TO CREATE EQUIPMENT SCHEDULE IN HAP AFTER CALCULATION
@ashokrawat9081
@ashokrawat9081 6 ай бұрын
Super sir ji.
@arjunvermaverma1585
@arjunvermaverma1585 7 ай бұрын
Very nice ❤
@hvactraining22
@hvactraining22 7 ай бұрын
Thank you
@SalauddinAnsari-xh7lz
@SalauddinAnsari-xh7lz 8 ай бұрын
Very good expalanation
@muhammadnaeem4834
@muhammadnaeem4834 9 ай бұрын
Nice
@chiragprajapati4853
@chiragprajapati4853 9 ай бұрын
Thank you sir for sharing great knowledge
@prakashgotame8875
@prakashgotame8875 10 ай бұрын
Sir compressor pumping less ya system me oil chada haii hoii super heat And subcooling. Me kya hota haii
@ultraAirConditioning1
@ultraAirConditioning1 10 ай бұрын
Good bhai
@tufailahmad9352
@tufailahmad9352 Жыл бұрын
Very good thanks for explaining
@Ameerfaisal5510
@Ameerfaisal5510 Жыл бұрын
Lekin tube to bhayya khada nahi pada hai yani horizontal hai
@chahatkumari409
@chahatkumari409 Жыл бұрын
Awesome explain with clear view
@jollyscaria1922
@jollyscaria1922 11 ай бұрын
Chillar ecomaizer liuqde line hot gas gas circutand het tasfeezr luiqd gas gas down vapar asber go shell tbe tup us plate tup us economizer shell tube heat exchanger cooler asme ...waterside disgn bar psi ..10 /147 ...Tst pressure bar psg 11.3v 165 refrigerant side 1 disign pressure bar 15vv.5 psig 15.5 228 .test side prssure bar psi g . 23 .3v /342 .allcabint all units are of hevavy gauge G 90 . Steel steel pannls are zinc coc ayed and galvanized by hot dipproces of lock -forming bquality conforing astm A 653 commercial weght G-90 followed by air dry by paint or backed on elelectro stic ploy ster dhot rmove systomadeitionor removelof hetofheat to dothis two heat exchangers levlare usedoner for heating in winter the other for cooling in summer the heating medimummay be hot wat or folw gas seem hot water flowes thrugh coils placed in air stream to be heated the tempererture is usually regulated hot gas circultimg liuqde gas dpwe ecomizer ver go asbrs systom chillar. ry power colat.
@chahatkumari409
@chahatkumari409 Жыл бұрын
Ise economizer nhi bolte kyuki ye sirf oil ko coll karta h ise heat exchanger hi bolte h jo plate type hai, economizer ka kam alag hota h jai evaporator and condenser dono heat exchanger hai tube type please correct sir
@sandeeptripathi4742
@sandeeptripathi4742 Жыл бұрын
Kuch samaj ni aya
@hvactraining22
@hvactraining22 Жыл бұрын
Supply me positive Return me negative Aata hai.
@sarojmahato9213
@sarojmahato9213 Жыл бұрын
Sir HVAC technician ka kam kaha se sikhe.
@sarojmahato9213
@sarojmahato9213 Жыл бұрын
Thanks sir 🙏
@MdShahid-tt8rd
@MdShahid-tt8rd Жыл бұрын
Thanks bro
@ankitgiri4923
@ankitgiri4923 Жыл бұрын
Sir train chiller mr atb kaise kam krta hai or evaporator and condenser me kitne mm ka tube ata hai
@hvactraining22
@hvactraining22 Жыл бұрын
Atb pe ek video aapko de dunga , explain kar dunga kaise kaam karta hai
@hectorlombardi8975
@hectorlombardi8975 Жыл бұрын
Condenser and evaporator chiller is different 3gpm condenser and 2.4gpm evaporator
@tan684
@tan684 Жыл бұрын
Hello
@hvactraining22
@hvactraining22 Жыл бұрын
Hii
@ankitgiri4923
@ankitgiri4923 Жыл бұрын
Type of evaporator please answer and working
@md.shahid4305
@md.shahid4305 Жыл бұрын
Trane model ka ahu hai magar pata kaise chale ki ye kine Cfm ka hai....
@md.shahid4305
@md.shahid4305 Жыл бұрын
Bag filter size kaha mention rahta batiyiyega bhai
@hvactraining22
@hvactraining22 Жыл бұрын
Filter ka video hai usme dikhega ,maine ek video dala hai use dekho
@md.shahid4305
@md.shahid4305 Жыл бұрын
Air cooled chiller ka screw compressor aur uske Bahar lage device ka video banayiye
@hvactraining22
@hvactraining22 Жыл бұрын
Zarur bhai bahut jaldi
@mohdkhalid6701
@mohdkhalid6701 Жыл бұрын
Brother what is the name of chemical?
@hvactraining22
@hvactraining22 Жыл бұрын
Nalcool ek brand hai wo use karte hain. (Sodium silicate, sodium nitrite and Sodium sulphite ) ye chemical bhi use karte hain.
@mohdkhalid6701
@mohdkhalid6701 Жыл бұрын
@@hvactraining22 thank you so much 💖
@hvactraining22
@hvactraining22 Жыл бұрын
@@mohdkhalid6701 your welcome bro, If any doubt you can ask me anytime.
@mohdkhalid6701
@mohdkhalid6701 Жыл бұрын
@@hvactraining22 sure brother if i have any query i will ask Thank you so much and i have subscribed your channel and i will recommend your channel to my friends
@hvactraining22
@hvactraining22 Жыл бұрын
@@mohdkhalid6701 thank you
@educarewithaslam2047
@educarewithaslam2047 Жыл бұрын
Economizor ka meaning aap Galt bata rahe hai. Aap ka dictionary galat hai
@hvactraining22
@hvactraining22 Жыл бұрын
Aapne sahi kaha economiser means energy efficient bhi hota hai, but ( to perform useful function such as preheating a fluid) Ye bhi hota hai bro.
@hvactraining22
@hvactraining22 Жыл бұрын
Hum jiske liye baat kar rahe wo yahi hoga.
@i.kfactsinhindi5570
@i.kfactsinhindi5570 Жыл бұрын
Very good explain bro
@hvactraining22
@hvactraining22 Жыл бұрын
Thanks
@Cricketemoment
@Cricketemoment Жыл бұрын
Dps switch filter alam ke liye use kiya jaata hai dusty hone par alam show karta hai right sir
@hvacengineer4842
@hvacengineer4842 Жыл бұрын
Fan ke pas wala bhi bana de sir
@hvactraining22
@hvactraining22 Жыл бұрын
Okay bhai
@hvacengineer4842
@hvacengineer4842 Жыл бұрын
@@hvactraining22 thanks sir