How much? And could I buy a black variable speed face I have the one that is silver.
@jimrasa97059 ай бұрын
Thank You! This is the best explanation of an ECM that I was able to understand! 🙂
@hectorlongoria9625 Жыл бұрын
I have x13 electronic air handler after it does its cycle fan turns back on for a second turns of it does it 3 to 10 times at a time icm both have been replaced also fan motor but still does the same thing any information
@GotchaplumberGotchahvac Жыл бұрын
Good information.
@Trump2024-z7t Жыл бұрын
So if I don't want to connect 24 V to the speeds. I could spend a $160 on this device? Really.
@CCCC-tq8yo Жыл бұрын
Goooooo Stan
@goodvibes5471 Жыл бұрын
Can I reprogram my new ecm computer with this to my Cadillac DeVille 2002
@jkbrown5496 Жыл бұрын
The problem is while ECM technology is excellent, the high amperage at high static pressures burns out the controls. This is not a concern to the mfrs as they please the government with an efficiency test on a pristine design system, and as the motors are mfr/system specific the mfrs can charge near 30% of the cost of original system for the replacement motor. All “savings” used to sell high SEER to customers is then reclaimed by the mfrs with all the heat going onto the HVAC contractor/tech. As everything is in the control microprocessor, they could program the motors to not go up so high in amp draw and save the motor, but then they’d lose out on the lucrative parts profits from being the sole source supplier of properly characterized modules. Also, the customer gets a long period of no HVAC while the part is being shipped in.
@joesprauve2408 Жыл бұрын
Happening to me as I type this been out of AC four five days now as I wait for an new ECM smh
@realSamAndrew Жыл бұрын
@@joesprauve2408 you should just replace it with a new PSC motor and call it a day. Then in the future, you have a much easier repair if needed again.
@Mr_Steve3D Жыл бұрын
That is a great idea instead of old-school wire nuts!
@georgekircher1416 Жыл бұрын
Can this be used on carrier infinity with ECM 3.0 module
@davidkish12512 жыл бұрын
Excellent Instructor, clear and deliberate
@Austin231912 жыл бұрын
Ha! A module for $100! I wish. I bought a module for a lennox ecm blower and it was $600
@brianlittle7172 жыл бұрын
AC to DC to 3 phase AC? What’s the purpose of the DC?
@mackenziegray20902 жыл бұрын
DC voltage is more powerful than AC. But we use AC at our house because it can travel much farther distance. You can use a cordless drill, say a 12volt battery and do the same work compared to a 120v corded drill. It's just more energy efficient.
@mackenziegray20902 жыл бұрын
The 3 phase Ac really is just artificial AC voltage. It just pulsating that dc voltage at the motors poles and creating that AC sine wave you would see on an oscilloscope.
@brianlittle7172 жыл бұрын
@@mackenziegray2090 work and power have nothing to do with AC or DC. Work is the product of force and distance. Power is the rate of doing work. It’s more to do with the horsepower as to how much power a motor has and less to do with the source of energy.
@brianlittle7172 жыл бұрын
@@mackenziegray2090 why not just run it on AC to begin with? Is the benefit in going from single to three phase?
@mackenziegray20902 жыл бұрын
@@brianlittle717 I was just using the word power or work to describe you can do more with dc than ac. Ecm motors really don't pull that much amps compared to psc motors. Especially if you let the capacitor degrade over time they'll pull even more amps because the motor isn't spinning fast enough to create back EMF or its own resistance with inductive reactance.
@brianlittle7172 жыл бұрын
I don’t understand what’s meant by 3 phase in DC current. There’s no such thing as 3 phase in DC.
@brianlittle7172 жыл бұрын
@@donalddebat57 I gotcha. An artificial 3 phase sine wave then. But that would be an AC sine wave none the less. Not a direct current.
@waltersmith79502 жыл бұрын
@@brianlittle717 The DC is used just like an inverter which produces pure sine wave voltage. In this case it produces 3 phase variable voltage and frequency. Don't know what the output would look like on a scope. Even more complicated is that only 2 phases (120 degrees apart) are powered at any given time (sequentially) thus causing the magnetic rotor to turn and the unpowered phase receives EMF generated by the rotor which is used as a feedback to determine commutation, direction and speed. I don't know if the power sent to the 2 phases is in the form of a +/- sine wave or a +/- pulse. The whole idea is fascinating and it definitely works. I have a 19 yr old 2 stage gas heating & cooling (dual compressor & txv on evaporator) system with variable speed & ramping on the blower, condenser fan and inducer. The biggest advantage is humidity control in summer by varying CFM. When heating, even the inducer speed is lowered shortly after the cycle starts which possibly allows hotter air to be circulated(?). The condenser fan seems to run either high or low as per which pump is running (and switching to the larger pump only happens on a super hot day). Since installed, the larger pump probably only has 20 hrs run time. If I had it to do over again ($), for cooling I would go with a single compressor, txv on evaporator and definitely variable & ramping blower. I hope my rambling helps in some small way. 😄
@brianlittle7172 жыл бұрын
@@waltersmith7950 like I said. The inverter is creating alternating current. Refrigerators have been using variable drive. The advantage is there is no temperature swing between the on and off cycles. The disadvantage with refrigerators anyway, is that they compressors only last a couple years.
@waltersmith79502 жыл бұрын
@@brianlittle717 OK.
@brianlittle7172 жыл бұрын
@@pauledwards3325 almost. A rectifier circuit needs a lot of filtering to simulate a true direct current, but it is part of a power supply. If you start with a single phase AC power source and use a power supply to produce a direct current, then you simply have a direct current. The term 3 phase relates to the three wires and the three transformers on the power pole, where voltage sine waves are 120* apart from one wire to the next. In DC, there are no sine waves, but depending how well it’s filtered, there could be harmonics. There actually is such a thing as a 3 phase rectifier but it is for high power industrial applications, must have 3 phase service from the power company, and they are extremely rare in the last 50 years or so. The 3 phase rectifier reduced the effect of harmonics, but transistor circuits have solved that problem anyway.
@toanvocong92052 жыл бұрын
how did you do it can you share with me , thank you
@winstagram17852 жыл бұрын
The motor module is basically a 3-phase motor, so use the plug to ohm between each leg(L1-L2/L1-L3/L2-L3) and they should all be within 10% of each other. I think typically under 20ohms. Then check each leg to ground. If there is any resistance to ground the winding is open.
@nestorcalleros13872 жыл бұрын
Información en español
@nestorcalleros13872 жыл бұрын
En español videos por favor
@tripplewhipper3 жыл бұрын
Thanks for the video, very informative
@mikefixac3 жыл бұрын
Thanks for the video. Well done for sure. Went to look for Part II, but was unsuccessful.
@alexzapata6923 жыл бұрын
Great presentation. Very informative.
@otrotland53773 жыл бұрын
wow, been looking for this for over a year, thank you
@Ric_James3 жыл бұрын
This video is great and needs more comments!
@ZebraHVAC3 жыл бұрын
We're glad you enjoy the Video! Thanks for commenting!
@ping_me1vp4 жыл бұрын
Yea winding test u don't need to take motor out u can use ur dmm to verify windings are good or not just went through one recently
@russelllieser42264 жыл бұрын
Does it work with all manufacture of equipment?
@ZebraHVAC4 жыл бұрын
Great Question Russell! Zebra HVAC does offer adapters for specific motor types for the VZ-7, but should always be confirmed with a licensed HVAC professional. Find out more at: VariableSpeedZebra.com
@thehowtos7994 жыл бұрын
Do you have a video on installing a ZAP PRO.
@ZebraHVAC4 жыл бұрын
Currently, we do not have a instructional video for ZAPPRO installation. For more information, including instructions and technical information, visit: zebrahvac.com/ZAPPRO.php
@jaysonhines14 жыл бұрын
I have been waiting for this product. Ty.
@robertricksecker76955 жыл бұрын
Can you use different adapters for various ECM models. Trying to determine if I should purchase this product or universal tester.
@ZebraHVAC4 жыл бұрын
Yes, Adapters are made for various ECM Models. Visit us at: VariableSpeedZebra.com to find out more! And check with your local distributor for purchase options
@chuckbear19615 жыл бұрын
Good demo on the work . I noticed these motors first showed up in VCR tape drives & brushless DC fans in the 1980`s. now used in Radio controlled cars & planes ,Hybrid cars ,power tools & so on even battery powered Zero turn lawn mowers . I`m getting into the study of them .
@bart1meuz6 жыл бұрын
Having one of these installed is a no brainer
@AKdaRockStarrOfficial6 жыл бұрын
Very informative. My VSZ works wonders with ECM motors
@pahick546 жыл бұрын
Very well done. Thank you!
@panike7 жыл бұрын
I wish i knew about this protector before my motor went out from the power surge.
@aodhmacraynall89327 жыл бұрын
good stuff
@dragonfury36028 жыл бұрын
thank you
@jimbola778 жыл бұрын
nice video!!!!
@AlanLenisa8 жыл бұрын
very well explained
@MP_Soundbox9 жыл бұрын
Very helpful, thanks! A coworker told me there is a way to temporarily run an ecm motor without the module? It sure doesn't look like that's possible.
@ebfsystem9 жыл бұрын
Till this day this information it's really really helpful! Thanks, P.D any more recent videos/training about this motors?
@mychoclabwinston10 жыл бұрын
Gentec also has a ECM motor tester, when not sure if it the board or module, motor, very easy test, my company bought me one, not sure on the price, they also supply a manual, with all resistance readings, if under warranty, and the control module failed, I always replace both.
@hvaccityman11 жыл бұрын
To do the X-13 motors you need adapter C which is UZHMC. This does the does the X- motor ECM and X-13