VZ7 Demonstrator Pac (VZDEM)
6:38
Zebra Connectors Promo Video (ZSLCK)
0:57
Product Highlight: ZebraStat
2:05
4 жыл бұрын
Understanding ECM Motors
36:02
4 жыл бұрын
VZPRO - ECM Protector
4:53
14 жыл бұрын
The VZREP ECM Repair Kit
4:39
14 жыл бұрын
Accessory Case (Part # UZACC)
1:38
14 жыл бұрын
Main Harness Replacement / Extension
2:26
Universal Zebra Training: Overview
1:34
Пікірлер
@globecomputers1
@globecomputers1 5 ай бұрын
Yeah how much?
@jesseruiz9257
@jesseruiz9257 5 ай бұрын
How much? And could I buy a black variable speed face I have the one that is silver.
@jimrasa9705
@jimrasa9705 9 ай бұрын
Thank You! This is the best explanation of an ECM that I was able to understand! 🙂
@hectorlongoria9625
@hectorlongoria9625 Жыл бұрын
I have x13 electronic air handler after it does its cycle fan turns back on for a second turns of it does it 3 to 10 times at a time icm both have been replaced also fan motor but still does the same thing any information
@GotchaplumberGotchahvac
@GotchaplumberGotchahvac Жыл бұрын
Good information.
@Trump2024-z7t
@Trump2024-z7t Жыл бұрын
So if I don't want to connect 24 V to the speeds. I could spend a $160 on this device? Really.
@CCCC-tq8yo
@CCCC-tq8yo Жыл бұрын
Goooooo Stan
@goodvibes5471
@goodvibes5471 Жыл бұрын
Can I reprogram my new ecm computer with this to my Cadillac DeVille 2002
@jkbrown5496
@jkbrown5496 Жыл бұрын
The problem is while ECM technology is excellent, the high amperage at high static pressures burns out the controls. This is not a concern to the mfrs as they please the government with an efficiency test on a pristine design system, and as the motors are mfr/system specific the mfrs can charge near 30% of the cost of original system for the replacement motor. All “savings” used to sell high SEER to customers is then reclaimed by the mfrs with all the heat going onto the HVAC contractor/tech. As everything is in the control microprocessor, they could program the motors to not go up so high in amp draw and save the motor, but then they’d lose out on the lucrative parts profits from being the sole source supplier of properly characterized modules. Also, the customer gets a long period of no HVAC while the part is being shipped in.
@joesprauve2408
@joesprauve2408 Жыл бұрын
Happening to me as I type this been out of AC four five days now as I wait for an new ECM smh
@realSamAndrew
@realSamAndrew Жыл бұрын
@@joesprauve2408 you should just replace it with a new PSC motor and call it a day. Then in the future, you have a much easier repair if needed again.
@Mr_Steve3D
@Mr_Steve3D Жыл бұрын
That is a great idea instead of old-school wire nuts!
@georgekircher1416
@georgekircher1416 Жыл бұрын
Can this be used on carrier infinity with ECM 3.0 module
@davidkish1251
@davidkish1251 2 жыл бұрын
Excellent Instructor, clear and deliberate
@Austin23191
@Austin23191 2 жыл бұрын
Ha! A module for $100! I wish. I bought a module for a lennox ecm blower and it was $600
@brianlittle717
@brianlittle717 2 жыл бұрын
AC to DC to 3 phase AC? What’s the purpose of the DC?
@mackenziegray2090
@mackenziegray2090 2 жыл бұрын
DC voltage is more powerful than AC. But we use AC at our house because it can travel much farther distance. You can use a cordless drill, say a 12volt battery and do the same work compared to a 120v corded drill. It's just more energy efficient.
@mackenziegray2090
@mackenziegray2090 2 жыл бұрын
The 3 phase Ac really is just artificial AC voltage. It just pulsating that dc voltage at the motors poles and creating that AC sine wave you would see on an oscilloscope.
@brianlittle717
@brianlittle717 2 жыл бұрын
@@mackenziegray2090 work and power have nothing to do with AC or DC. Work is the product of force and distance. Power is the rate of doing work. It’s more to do with the horsepower as to how much power a motor has and less to do with the source of energy.
@brianlittle717
@brianlittle717 2 жыл бұрын
@@mackenziegray2090 why not just run it on AC to begin with? Is the benefit in going from single to three phase?
@mackenziegray2090
@mackenziegray2090 2 жыл бұрын
@@brianlittle717 I was just using the word power or work to describe you can do more with dc than ac. Ecm motors really don't pull that much amps compared to psc motors. Especially if you let the capacitor degrade over time they'll pull even more amps because the motor isn't spinning fast enough to create back EMF or its own resistance with inductive reactance.
@brianlittle717
@brianlittle717 2 жыл бұрын
I don’t understand what’s meant by 3 phase in DC current. There’s no such thing as 3 phase in DC.
@brianlittle717
@brianlittle717 2 жыл бұрын
@@donalddebat57 I gotcha. An artificial 3 phase sine wave then. But that would be an AC sine wave none the less. Not a direct current.
@waltersmith7950
@waltersmith7950 2 жыл бұрын
@@brianlittle717 The DC is used just like an inverter which produces pure sine wave voltage. In this case it produces 3 phase variable voltage and frequency. Don't know what the output would look like on a scope. Even more complicated is that only 2 phases (120 degrees apart) are powered at any given time (sequentially) thus causing the magnetic rotor to turn and the unpowered phase receives EMF generated by the rotor which is used as a feedback to determine commutation, direction and speed. I don't know if the power sent to the 2 phases is in the form of a +/- sine wave or a +/- pulse. The whole idea is fascinating and it definitely works. I have a 19 yr old 2 stage gas heating & cooling (dual compressor & txv on evaporator) system with variable speed & ramping on the blower, condenser fan and inducer. The biggest advantage is humidity control in summer by varying CFM. When heating, even the inducer speed is lowered shortly after the cycle starts which possibly allows hotter air to be circulated(?). The condenser fan seems to run either high or low as per which pump is running (and switching to the larger pump only happens on a super hot day). Since installed, the larger pump probably only has 20 hrs run time. If I had it to do over again ($), for cooling I would go with a single compressor, txv on evaporator and definitely variable & ramping blower. I hope my rambling helps in some small way. 😄
@brianlittle717
@brianlittle717 2 жыл бұрын
@@waltersmith7950 like I said. The inverter is creating alternating current. Refrigerators have been using variable drive. The advantage is there is no temperature swing between the on and off cycles. The disadvantage with refrigerators anyway, is that they compressors only last a couple years.
@waltersmith7950
@waltersmith7950 2 жыл бұрын
@@brianlittle717 OK.
@brianlittle717
@brianlittle717 2 жыл бұрын
@@pauledwards3325 almost. A rectifier circuit needs a lot of filtering to simulate a true direct current, but it is part of a power supply. If you start with a single phase AC power source and use a power supply to produce a direct current, then you simply have a direct current. The term 3 phase relates to the three wires and the three transformers on the power pole, where voltage sine waves are 120* apart from one wire to the next. In DC, there are no sine waves, but depending how well it’s filtered, there could be harmonics. There actually is such a thing as a 3 phase rectifier but it is for high power industrial applications, must have 3 phase service from the power company, and they are extremely rare in the last 50 years or so. The 3 phase rectifier reduced the effect of harmonics, but transistor circuits have solved that problem anyway.
@toanvocong9205
@toanvocong9205 2 жыл бұрын
how did you do it can you share with me , thank you
@winstagram1785
@winstagram1785 2 жыл бұрын
The motor module is basically a 3-phase motor, so use the plug to ohm between each leg(L1-L2/L1-L3/L2-L3) and they should all be within 10% of each other. I think typically under 20ohms. Then check each leg to ground. If there is any resistance to ground the winding is open.
@nestorcalleros1387
@nestorcalleros1387 2 жыл бұрын
Información en español
@nestorcalleros1387
@nestorcalleros1387 2 жыл бұрын
En español videos por favor
@tripplewhipper
@tripplewhipper 3 жыл бұрын
Thanks for the video, very informative
@mikefixac
@mikefixac 3 жыл бұрын
Thanks for the video. Well done for sure. Went to look for Part II, but was unsuccessful.
@alexzapata692
@alexzapata692 3 жыл бұрын
Great presentation. Very informative.
@otrotland5377
@otrotland5377 3 жыл бұрын
wow, been looking for this for over a year, thank you
@Ric_James
@Ric_James 3 жыл бұрын
This video is great and needs more comments!
@ZebraHVAC
@ZebraHVAC 3 жыл бұрын
We're glad you enjoy the Video! Thanks for commenting!
@ping_me1vp
@ping_me1vp 4 жыл бұрын
Yea winding test u don't need to take motor out u can use ur dmm to verify windings are good or not just went through one recently
@russelllieser4226
@russelllieser4226 4 жыл бұрын
Does it work with all manufacture of equipment?
@ZebraHVAC
@ZebraHVAC 4 жыл бұрын
Great Question Russell! Zebra HVAC does offer adapters for specific motor types for the VZ-7, but should always be confirmed with a licensed HVAC professional. Find out more at: VariableSpeedZebra.com
@thehowtos799
@thehowtos799 4 жыл бұрын
Do you have a video on installing a ZAP PRO.
@ZebraHVAC
@ZebraHVAC 4 жыл бұрын
Currently, we do not have a instructional video for ZAPPRO installation. For more information, including instructions and technical information, visit: zebrahvac.com/ZAPPRO.php
@jaysonhines1
@jaysonhines1 4 жыл бұрын
I have been waiting for this product. Ty.
@robertricksecker7695
@robertricksecker7695 5 жыл бұрын
Can you use different adapters for various ECM models. Trying to determine if I should purchase this product or universal tester.
@ZebraHVAC
@ZebraHVAC 4 жыл бұрын
Yes, Adapters are made for various ECM Models. Visit us at: VariableSpeedZebra.com to find out more! And check with your local distributor for purchase options
@chuckbear1961
@chuckbear1961 5 жыл бұрын
Good demo on the work . I noticed these motors first showed up in VCR tape drives & brushless DC fans in the 1980`s. now used in Radio controlled cars & planes ,Hybrid cars ,power tools & so on even battery powered Zero turn lawn mowers . I`m getting into the study of them .
@bart1meuz
@bart1meuz 6 жыл бұрын
Having one of these installed is a no brainer
@AKdaRockStarrOfficial
@AKdaRockStarrOfficial 6 жыл бұрын
Very informative. My VSZ works wonders with ECM motors
@pahick54
@pahick54 6 жыл бұрын
Very well done. Thank you!
@panike
@panike 7 жыл бұрын
I wish i knew about this protector before my motor went out from the power surge.
@aodhmacraynall8932
@aodhmacraynall8932 7 жыл бұрын
good stuff
@dragonfury3602
@dragonfury3602 8 жыл бұрын
thank you
@jimbola77
@jimbola77 8 жыл бұрын
nice video!!!!
@AlanLenisa
@AlanLenisa 8 жыл бұрын
very well explained
@MP_Soundbox
@MP_Soundbox 9 жыл бұрын
Very helpful, thanks! A coworker told me there is a way to temporarily run an ecm motor without the module? It sure doesn't look like that's possible.
@ebfsystem
@ebfsystem 9 жыл бұрын
Till this day this information it's really really helpful! Thanks, P.D any more recent videos/training about this motors?
@mychoclabwinston
@mychoclabwinston 10 жыл бұрын
Gentec also has a ECM motor tester, when not sure if it the board or module, motor, very easy test, my company bought me one, not sure on the price, they also supply a manual, with all resistance readings, if under warranty, and the control module failed, I always replace both.
@hvaccityman
@hvaccityman 11 жыл бұрын
To do the X-13 motors you need adapter C which is UZHMC. This does the does the X- motor ECM and X-13
@newstart49
@newstart49 12 жыл бұрын
Does it do X13 motors?