Пікірлер
@javimar6467
@javimar6467 2 күн бұрын
Teflón nunca
@BrumCraft
@BrumCraft 4 күн бұрын
That pipe bender is quality. I need to do this soon - is there no need for compound between the thermostat and copper?
@antanasmastaras795
@antanasmastaras795 12 күн бұрын
I had a few stainless steel Telford cylinders leaking from new, cousing quite a substantial damage to the property 🤬. It failed on seam weld on one, and the other one leaked through immersion. I claimed for damages, and after a long battle, they agreed to compensate. However, I no longer trust them to use their products. Their's so-called quality check stamp means absolutely nothing. I hope you didn't end up using your insurance as this often leads to another nightmare of premiums skyrocketing or even refusal.
@griffithsheating
@griffithsheating 12 күн бұрын
@@antanasmastaras795 we’ve had more Telford cylinders fail since this one. The last one Telford made the customer buy a new cylinder and said they would investigate who is to blame and let us know…..well we all know how that is going to end don’t we…..warranty not worth the paper it’s written on and I would never fit Telford ever again.
@criartoros
@criartoros 12 күн бұрын
If there's no comebacks, job done. Good video mate. 👍
@griffithsheating
@griffithsheating 12 күн бұрын
3 years on and it hasn’t moved 😀 I went back to it a few months ago to unblock the trap as someone decided to pour their dinner scraps down it 🤔🤢
@rowanballinger3690
@rowanballinger3690 18 күн бұрын
You need some pumps there 🤣
@Apexplumber
@Apexplumber 28 күн бұрын
Good job
@veenpa
@veenpa 29 күн бұрын
Customer sounds like a right prick
@CardiffGuru67
@CardiffGuru67 Ай бұрын
Bit confused, did you put the membrane over the expansion foam or do you put the membrane down first then the exoansion foam? Im finding it hard to stick foam to wall? Does it matter? Also have you got to put pir upstand around all the walls or just the external walls?
@royhuijsmans6117
@royhuijsmans6117 Ай бұрын
Quality job! so if i get it right , your bedrooms have the same temp as your living? or...you use less heatingsurface for the bedrooms?
@griffithsheating
@griffithsheating Ай бұрын
You can design the bedroom temps lower than the living temps so yes your bedroom rads will end up smaller
@Allegedly2right
@Allegedly2right Ай бұрын
How do you set the flow rate no one wants to tell you how to do it.
@griffithsheating
@griffithsheating Ай бұрын
Ufh flow rate is set by the manifold flow setters and the rads can be set with either a flow balancer or flow setting rad valves. Or you could use what’s called a stad valve
@Allegedly2right
@Allegedly2right Ай бұрын
@@griffithsheating Cheers it is a Grant Aerona with a low loss header only 9 rads the T1-T2 is only about 2-3 nightmare.
@griffithsheating
@griffithsheating Ай бұрын
@@Allegedly2right bare in mind that your dt will only be at design (5, 7, 10 or whatever) when you are on a design day which is a day below zero degrees outside. Anything more than that the dt will narrow.
@saadrasheed101
@saadrasheed101 2 ай бұрын
Looks like a 3 port volumiser?
@studio-67
@studio-67 2 ай бұрын
Thank you for a frank straightforward explanation on this.
@floydfranklin8881
@floydfranklin8881 2 ай бұрын
great video and editing.
@danielseddon3177
@danielseddon3177 2 ай бұрын
Did you consider smaller pipe spacing to allow for lowest flow temp possible for the HP? Looks like those panels might go as low as 50mm.
@griffithsheating
@griffithsheating 2 ай бұрын
There were a few serious install issues on this job created by the original installers that would make a super low flow temp a bad thing. They fitted a GSHP with a fixed speed compressor just to ‘get the job done’ (grant money banked) when they should have fitted an inverter driven unit as specified. And they massively undersized the buffer. The hp was cycling bad enough already and having persistent high pressure faults, trying to run it at <45 degrees with the available system volume would make it worse. All my advice fell on deaf ears though and now I’m probably the bad guy 🤷
@danielseddon3177
@danielseddon3177 2 ай бұрын
OK. Sorry to hear that.
@AdamSkelly-vz3ih
@AdamSkelly-vz3ih 2 ай бұрын
Hello mate - nice install. What is the lagging internally with the " socks " for over the fittings. Only ever used Primary pro or Pump houses own products but this looks great
@griffithsheating
@griffithsheating 2 ай бұрын
It’s just Armaflex taped with class zero tape 👍🏻
@pmbpmb5416
@pmbpmb5416 2 ай бұрын
I’m having two 12kw cascaded , I don’t know enough to be sure whether a none zoned open loop system would work . Ufloor on ground floor radiators on other two which I’m hoping to size sufficiently to balance . I’d like to get it down to 35 flow but currently spec is 50 , which worries me for running cost . Re insulated everything.
@griffithsheating
@griffithsheating 2 ай бұрын
We’ve done a similar split upstairs / downstairs cascade with a pair Viessmann vitocals. You will have better low modulation performance and ultimate control in this configuration in my opinion. Not sure you could open loop a true cascade as it would probably need a buffer I would have thought. There is nothing wrong with a buffer, not everyone is interested in chasing the last few percentage of performance. Its a central heating system not formula 1 car
@timcook2571
@timcook2571 3 ай бұрын
“Scabby cunt” 😂
@stixstonesinvestors5413
@stixstonesinvestors5413 3 ай бұрын
Lovely. Open loop 🔥🔥🔥
@griffithsheating
@griffithsheating 3 ай бұрын
😎👍🏻
@Foss1985
@Foss1985 3 ай бұрын
Nice install! How do you find these compared with the Vitocals?
@griffithsheating
@griffithsheating 3 ай бұрын
Vaillant is better priced, easier to get hold of, easier to quote for, better manufacturer support, no need for indoor unit so fits in a smaller space and vaillant seem to know Their product better than Viessmann BUT the Viessmann controls on the 150a are superior to the Vaillant.
@gerardfry4876
@gerardfry4876 3 ай бұрын
Are you bending the UFH down to lower temp or just running 45oc with rads?
@griffithsheating
@griffithsheating 3 ай бұрын
No blending. Just letting the heat pump do its thing unrestricted.
@gerardfry4876
@gerardfry4876 3 ай бұрын
@@griffithsheating it makes sense, less expensive mixer station/pumps better savings. Is this your standard going forward then? Do you just run one stat for the whole house?
@griffithsheating
@griffithsheating 3 ай бұрын
@@gerardfry4876 there is a wireless Vaillant senso comfort controlling it so you can either run it as a room stat or just off a curve with no room influence. Not sure how the customer will want to run it yet.
@gerardfry4876
@gerardfry4876 3 ай бұрын
And if the pump on the HP can’t supply the index circuit with enough flow, would you fit a buffer then?
@griffithsheating
@griffithsheating 3 ай бұрын
@@gerardfry4876 yes if my calculations are wrong I’d have to convert the volumiser to a buffer and add another pump.
@user-us9ib8ww9x
@user-us9ib8ww9x 3 ай бұрын
Great video pal 👊🏻
@Abc_Heating
@Abc_Heating 3 ай бұрын
Love the install👌🔥not sure about the Viessmann kettle tho 😂 Is this design on the Viessmann schematics, would love to know more about this method. Seems to be perfect for what we're looking to do for a customer we're going to be quoting for.
@kenbone4535
@kenbone4535 3 ай бұрын
Open loop amazing, shame the industry is about 2 decades behind.
@theghostofsirjohnharveyjon8730
@theghostofsirjohnharveyjon8730 3 ай бұрын
That's a tidy install fair play. What kind of cop do you think it will get?
@griffithsheating
@griffithsheating 3 ай бұрын
Over 4
@androleum
@androleum 3 ай бұрын
Which controller devices are used here?
@griffithsheating
@griffithsheating 3 ай бұрын
Sensocomfort
@TheDickPuller
@TheDickPuller 3 ай бұрын
What’s the Gas Boiler doing then mate??!! You sound a bit arrogant, no surprise you fell out with Kevin!!.......We’re fitting R290 stuff without F-Gas tickets here in Scotland. Just got LPG ACS ticket. 28mm to the UVC is grossly oversized & you’ve got Galv Band everywhere, what a mess. Are you all course cowboys??
@griffithsheating
@griffithsheating 3 ай бұрын
Sshhh don’t talk about the gas boiler or Kevin 🤫 we ran out of big clips. I’m not arrogant I’m just better than 99.9% of everyone else. I qualified 6 months ago so have a lot of experience.
@theghostofsirjohnharveyjon8730
@theghostofsirjohnharveyjon8730 3 ай бұрын
Boiler was obviously part of the old system to be ripped out.....🙄........
@scottcorz13
@scottcorz13 3 ай бұрын
to the bloke that needs an electric bender because he carnt pull a bend ' also pull youre head out of kevins ass and crack on with youre rad valves and tap washers Dick ' fairplay lads looks like you know what youre doing ' 💪💪
@joehaskett90
@joehaskett90 3 ай бұрын
Does the system not have enough volume for the defrost cycle? Would of that you could of got away without the volumizer
@griffithsheating
@griffithsheating 3 ай бұрын
I was thinking more of minimum run times when it’s mild out. I have seen Arotherms ice up though even when volume seems to be ok.
@kenbone4535
@kenbone4535 3 ай бұрын
Nope, the open loop system becomes the volume you need for Defrost, been installing like this for decades already.
@pradhpatle
@pradhpatle 3 ай бұрын
@@kenbone4535 Specially with UFH you have lot of energy mass around in case you need any excess energy for defrost.
@Liam_Hirst
@Liam_Hirst 3 ай бұрын
Is the volumiser just for the defrost cycle?
@MCow123
@MCow123 3 ай бұрын
I’ve just had the 5kW version installed with identical 50L volumiser, my installer (Heat Geek Elite) confirmed it was not just for defrost cycle but also ensuring there was enough volume in the circuit to prevent the ASHP cycling as much as it might without it (due to size of my system aside from the volumiser)
@alimack5489
@alimack5489 4 ай бұрын
Going to sound stupid here but how does that comply with G3 requirements if it doesn’t have a two port on the DHW I take it’s interlinked with an overheat stat on the tank?
@griffithsheating
@griffithsheating 4 ай бұрын
Not required (it's not shown on the vaillant schematics at least) I don't use 2 ports or over heat stat on gas either if I'm fitting a Viessmann boiler with an ntc sensor on 4 pipe. G3 police haven't arrested me yet... 🚓
@TheDickPuller
@TheDickPuller 3 ай бұрын
@@griffithsheatingBuilding Control would not give you a completion certificate with no 2 Port on the UVC here in Jockoland mate!!!
@jacbisgood2221
@jacbisgood2221 4 ай бұрын
We need to talk about K̶e̶v̶i̶n̶ Viessmann
@griffithsheating
@griffithsheating 4 ай бұрын
Let's just say we had a disagreement about the part L building regs 😄 They claimed all heating systems have to be designed to 45 degrees and I called 🐂💩 and 7 months later I'm still waiting for a BUS grant payment. I guess I'm not cool enough to join their club.
@jacbisgood2221
@jacbisgood2221 3 ай бұрын
@@griffithsheating what did you design to? Sounds out of order to me
@griffithsheating
@griffithsheating 3 ай бұрын
@@jacbisgood2221 designed to 55 due to rad space available but that's knowing the home owner is doing a load of additional insulation in the roof space and floor so will end up around 45/50 mark. It actually was finally signed off and grant paid today as it happens 😎
@loving-plumbing
@loving-plumbing 4 ай бұрын
Cliff hanger at the end 😂. Good work.
@m1geo
@m1geo 4 ай бұрын
No insulation under the pipes? 😬
@griffithsheating
@griffithsheating 4 ай бұрын
It's not a worry. I've done the sums. Insulation would be great in an ideal world but we don't live in an ideal world 😬
@loving-plumbing
@loving-plumbing 4 ай бұрын
Craziness
@drewid1
@drewid1 4 ай бұрын
Thank you for posting this and glad I found this video as it answers a lot of questions for our house refurbishment. This system is exactly what we are looking to fit. Weather controlled 200-W combi with ground underfloor heating and radiators on the first and second floors with no complicated internal controls and zone valves all over the place, I just want to keep it simple. Unfortunately, as I'm in Oxfordshire you are a long way from us so I can't ask you to fit it. Can I ask some questions so I can have an informed conversation with whoever does please. > The EM-M1 controller in the video has 6 cables to it. 1. 240v from the boiler on 40 2. UFH Pump on P1/20 3. UFH ESBE Mixer on P3/52 4. UFH Flow Temp Sensor on TS1/2 5. Boiler Data Link on 74 6. ?? - I can't see it, but is this cable another flow temperature sensor fitted to the unmixed radiator circuit on TS3/9 as there is hydraulic separation with the CCT? > The two Stuart Turner pumps - What settings were used for these? Different for the UFH and radiators? > Is the radiator circulation pump is connected to terminal P1 in the boiler as there is no hot water cylinder pump? > As an independent backup to prevent damage to the floor on the UFH would you fit a low limit pipe thermostat (set to around 40 degrees) between the mixer valve and flow temperature sensor to cutoff the pump? > Considering fitting Salus automatic balancing actuators to the UFH manifold - comments? Thank you for any feedback.
@doganaydin001
@doganaydin001 4 ай бұрын
Hi, Its a great job! I would like to ask, Do you know difference between Vitocal 150a and 250a? I was planning to install Vitocal 250a but installer mentioned that they have only 150a. I could not find main difference. Thanks in advance!
@griffithsheating
@griffithsheating 4 ай бұрын
Not sure if the 250 is on sale in the UK yet. Viessmann are pretty bad at keeping installers informed what's going on with their product line up.
@doganaydin001
@doganaydin001 4 ай бұрын
Hmm, sorry i did not mentioned that i am typing from Germany :) As i understood from datasheets, A150 is price/performance variant of 250A. 250a has a better coefficient value and more slient(66db vs 64db)
@MadDog_Rules
@MadDog_Rules 4 ай бұрын
Every single hotel i have been to, every single shower had failed. 😂
@user-dz9ho6vq5k
@user-dz9ho6vq5k 4 ай бұрын
shocking
@griffithsheating
@griffithsheating 4 ай бұрын
Aaaannnd 3 years later and the shower hasn't moved a mm and is water tight (I was back here last week repairing the trap as the tenant had damaged it trying to clean it )😎 Check that hubris at the door buddy
@TheLife0025
@TheLife0025 5 ай бұрын
What's the batten size
@UndisputableFact
@UndisputableFact 5 ай бұрын
One of the few videos which shows how it’s done properly. Really good video. What I can’t get my head around is how to size the pump for the rads after the cct. Will it not interfere with the boiler’s own pump modulation unless you use the same pump which is in the boiler?
@griffithsheating
@griffithsheating 5 ай бұрын
Cheets mate 😎 just size the 2nd pump to suit your index circuit. The hydronic gods will take care of all the other stuff. The worst that happens is that you get a bit of distortion. I.e. the boiler is running at 55 degrees but your flow temperature out of the secondary circuit is 50 degrees as it's pulling in return water through the CCT and lowering the flow temp.
@UndisputableFact
@UndisputableFact 6 күн бұрын
@@griffithsheating hello mate, just got round to doing this on my system. I was wondering where you would wire the additional pump for the rads after fitting the cct. if I wire it to come on when the zone valve for the rads opens, then it'll run when just the UFH is calling for heat, since they share the same switched live to the boiler. but if I wire to the switched live from the thermostat to the rads, it'll come on before the rads zone valve has opened. I've got a bypass radiator to dissipate heat though so I could have the pump before the branch to this and the zone valve controlled rad circuit. what do you think? sorry for bending your ear on this, do you think I should use a relay?
@griffithsheating
@griffithsheating 4 күн бұрын
@@UndisputableFact yep ideally you’ll need relays. I had the same problem. I can’t remember what I did to get around it I think I did something by taking the heads off the zone valve and using them as a pseudo relay of sorts……I really can’t remember….but it worked🤔🤨🧐
@UndisputableFact
@UndisputableFact 2 күн бұрын
@@griffithsheating all sorted, I can’t believe how well it works! Ended up wiring into a dedicated ‘powered’ terminal when on central heating for the boiler I’m using. I did kimbo betty’s course a couple of years ago but decided to do it the ‘wrong way’ first to see how bad it could be- and in my boiler’s case, it was very bad indeed. Should have done this sooner! Thanks again mate, this has made my year. keep up the good work! :)
@Mybabyboysofunny
@Mybabyboysofunny 5 ай бұрын
Anyway you could face time me and tell me if my motor took a dump 😇. Oh been a little cold here in Northern Michigan and have a 3 yr old. Motor (with the copper coil looks like) looks pretty rough. But a new tank on and pump etc last season. Pretty sure it’s the big bill coming now 🥺
@UrbanPlumbers
@UrbanPlumbers 5 ай бұрын
yes - the blue plug is DHW sensor and it is not 10k.
@julianhawker7672
@julianhawker7672 5 ай бұрын
Is there a rule of min/max distance between CCT? Rest of it all makes sense to me. Very useful video for me. I'm largely service/repair for many years now but just come across a similar job that I think would benefit from CCT and want to be sure of my facts before speaking with the householder . Cheers. 👍
@griffithsheating
@griffithsheating 5 ай бұрын
yeah there are some rules of thumb. The close coupled tees must not be more than 4 x the diameter of the pipe apart. Flow out of the cct to the system should be atleast 4 x the pipe diameter before the first bend and the return into the cct is 8 x diameter before first bend. Only important one really on a small domestic system is 4 x diameter between the ccts.
@julianhawker7672
@julianhawker7672 5 ай бұрын
@@griffithsheating Thanks, that very helpful. Cheers.
@Jonathanraymen
@Jonathanraymen 5 ай бұрын
How did you find the linking of the coils together worked out? Interested to hear your thoughts on this as I’ve considered doing it a few times.
@griffithsheating
@griffithsheating 5 ай бұрын
seems to be working ok.....no complaints and its been running for 12 months now.
@user-oq9yg3ic3p
@user-oq9yg3ic3p 6 ай бұрын
Hi great video - Just a couple of questions, Is it possible to have 3 circuits off the ccts and do you need pipe stats on each circuit
@griffithsheating
@griffithsheating 6 ай бұрын
This one was piped CCTs off a primary loop so if you had 3 circuits without mixers the 3rd circuit would be cooler than the first. If you mix all 3 circuits then you end up running the primary loop hotter to allow mixing down. Best way to do it depends on your design flow temps and the max heat load on each circuit
@user-oq9yg3ic3p
@user-oq9yg3ic3p 6 ай бұрын
@@griffithsheating thanks for the reply, tbf i was going to install one unmixed rad circuit, one unmixed towel radiator circuit and one mixed ufh circuit but i could just do away with the towel rail circuit and have just one unmixed circuit for rads and towel radiators. The ufh circuit is 75m2 and total number rads/towel radiators will be 13 do you think the type of installation you have installed in this video will be ok for this, I will be installing a Viessmann 200-w system boiler with WC too. Thanks
@griffithsheating
@griffithsheating 6 ай бұрын
@@user-oq9yg3ic3p you can only run one unmixed circuit natively through the boiler & vicare. All other circuits need a mixer. There are work arounds but it can confuse the customer. Ill usually try and get the customer to do towel rails on a dual fuel with element for summer. But yeah a CCT would do the trick. I've another video where I do ufh and rads on a CCT under a vaillant - that worked great
@sajhussain26
@sajhussain26 6 ай бұрын
Are those boards sitting directly on concrete slab, please?
@griffithsheating
@griffithsheating 6 ай бұрын
Yes they are.
@sajhussain26
@sajhussain26 6 ай бұрын
@@griffithsheating what's the system called please ?
@griffithsheating
@griffithsheating 6 ай бұрын
@@sajhussain26 John guest lowfit
@ram64man
@ram64man 7 ай бұрын
When the unit arrives is it possible to get it in a loft entrance or is it just one piece sac barrow only , the reason I ask is this would be perfect but means relocating in the property in the place of the old water store from a regular conversion ,, or would you recommend a separate system design instead
@griffithsheating
@griffithsheating 7 ай бұрын
It's an absolute beast of a thing and I wouldn't like to lift it into an attic it doesn't come apart😄 it's probably doable with enough brute force
@ram64man
@ram64man 7 ай бұрын
@@griffithsheating thanks mate at least it gives me some idea on future changes then in a different direction, do you think the 111 would cope adequately with two showers simultaneously 50c water
@ram64man
@ram64man 7 ай бұрын
Assuming the property has enough flow, what is the flow output at 50 or 60c, for hot water, all the paperwork refers to 18.1 litres at 35c but not at 50 or 60c
@griffithsheating
@griffithsheating 7 ай бұрын
That's a 35 degree rise so about 45 from the tap. I've seen them fitted where the cylinder is charged to max temp and a TMV fitted on the outlet to give more flow flow longer