I would get a UV flashlight that has wood's glass. The woods glass blocks the visible light from the purple.
@gerardryan59682 ай бұрын
Pointless video
@paulhenk81863 ай бұрын
You are completely incorrect they are not temporary they last a minimum of 8 years . NVR had one fail yet
@LC-qi5ff3 ай бұрын
Walk ins are the worst work in my book
@geraldgege3773 ай бұрын
J'ai plusieurs marque de régulateur celui avec le moins de sav et carel dixell en supervision et loin graphiquement et fiabilité par rapport a carel danfoss etc. Votre pays secteur ne travail peut avec carel comme dans mon secteur dixell et au millieu entre ako carel danfoss eliwell dixell etc Dixell la plupart des composants et fabrication réalisée en chine carel pour du oem chine car chez mes fournisseurs parfoit écrit dautre pays pour moi toutes les marques sont au même niveau qualité développement logiciel carel et danfoss de mon points de vue on une avance Johnsoncontrol moi j'aime pas car la logique de paramétrage et déroutant pour moi pourtant ils sont fiable chaque technicien a des préférences 1 câblage 2 paramétrage 3 visuel 4 fournisseurs (produit de qualité mais personne na de disponible tu installe autre chose). Ayant dans mon parc beaucoup de marque les services téléphoniques carel en france et ultra ractif dixell faut prendre rendez-vous par mail😂 voila un point de vue d'un autre frigoriste d'un autre pays.
@StoweLauren-t1c4 ай бұрын
Hernandez Jeffrey Lee Margaret Wilson Joseph
@BaconShuffler4 ай бұрын
How did you even remove the evap/condenser from the pop cooler?
@douglaslopez80584 ай бұрын
A you forgot to. Put another of water hose
@petersamios54094 ай бұрын
Great presentation. Like others have mentioned, in the classic legislation environment, where you are just pulling water from the tap to cool the condenser, yes - these are generally not eco friendly. However IMO, if you have a lake, a geothermal system, a small chiller, or the equivalent, you are much better off with the water cooled system.
@popsmccartney4355 ай бұрын
Thanks for sharing
@mrsexytime_5 ай бұрын
The only explanation on youtube that is real and helpful.
@noneofyourbusiness92365 ай бұрын
Really!!! Spraying that crap in a fruit freezer???, Is this guy a IDIOT, or just from some Country that doesn't know better? What a IDIOT!
@MiroHaidari5 ай бұрын
Thank you for your information
@rishikkeshari63066 ай бұрын
is it possible to reuse the hot water coming out for other purposes like toilet flush/washing machine?
@stevewayne36766 ай бұрын
Tell the truth you let the freon out into the air 😂
@deenamat4397 ай бұрын
what about 6 ?
@eddiesandler398425 күн бұрын
I think he meant you have 2 lines ..number 1 and number 6.. not 8! 8 is normally closed.. right?
@jackwelch97137 ай бұрын
can I have one of those chemically soaked oranges please? good lord
@khalid47157 ай бұрын
very cool concept of water cooled ACs
@bas42918 ай бұрын
hope you weren't the installer?
@savannamc4078 ай бұрын
Didn't get c1, only thing that showed up was rd, HELP
@orfatron7 ай бұрын
Yeah the video failed to mention each manufacturer sets the controler differently. Press and hold longer and enter access code 22. Then find C1 . Hope this is helpful. You can also find the chart symbols online easily .
@savannamc4077 ай бұрын
@@orfatron thank you
@craigmarshall408 ай бұрын
Nice work
@Dawn-di1qs8 ай бұрын
I would remove the entire EVAP coils and take outside to clean.. then completely let it sun dry.. Same with the fans... remove , take outside to clean.
@fotismil88109 ай бұрын
Mistakes friend,first defrost the evaporator,the valve allready is working low superheated and liquid is flooding in compresor.You "fixed it the opposite way",you destroyed it...haha
@rayclark77639 ай бұрын
Ty
@ZemusMeanest9 ай бұрын
Stop using trash
@JuanGarcia-tg1iu10 ай бұрын
How did you miss that pinched off liquid line at the bottom flare nut on the Txv valve?
@brandone625210 ай бұрын
I have a true drink cooler it was freezing the drinks no matter the setting it was on I replaced with a new thermostat off eBay and it will not cool below 50 degrees 831932 part number idk if you have any idea thank you
@dnoorian10 ай бұрын
Depends on the model of the true cooler you have. Each true equipment has a different type of thermostat. Call true mfg and they will give you the correct part number, then you can buy off www.partstown.com
@hvacmaster9610 ай бұрын
Will there be a video showing how freon is pumped into the receiver when the filter on the refrigerator is changed? Greeting
@Valerian-nb5wu10 ай бұрын
Where is your BEARD NET? That's a GMP VIOLATION.
@wesstevens713311 ай бұрын
You are using more refrigerant to cool the water in an exterior motion, and a pump which uses electricity to pump the water that the condenser is submerged in to merely achieve greater results all legal
@wesstevens713311 ай бұрын
All you must do is put the coil submerged in water, circulate the water with the pump to a reservoir of cold or water, using the same principle of AC to cool the condensing unit in no time the transfer of heat will be much greater
@AdvancedAirTechnologySC11 ай бұрын
I have a 115 volt walk in cooler. The compressor has a start and run capacitor. Would a 3n1 work on this application?
@thescurry Жыл бұрын
DO NOT follow this guys steps, he did it the incorrect way. 🤦🏻♂️
@Speedy3909-Trenchmob Жыл бұрын
Great information, thanks 👌
@Speedy3909-Trenchmob Жыл бұрын
Where do you get your stickers made and what software do you use to stay organized?
@DarryllShake-pu7fm Жыл бұрын
you idiot the cam was on fire 😂😂😂😂
@ricksilva3225 Жыл бұрын
Could not see any work being done
@davidflores5761 Жыл бұрын
Hello partner on duty! A got some kind of troubleshooting this type of problems... This time was a low ppressure in liquid line just afte filter drier (160psi) and quite good pressure in low side after evap n Comp rotalock (18-20psi) for a 404a walking in freezer meat storage. Txv and beyond still froozen. Sight glass is clear most the time then just flush ... I know is full, Maybe refull of refrigerante the entire system. Good both sides vents, cond-evap were washed. Help me, dont wanna loose this client😢
@davidflores5761 Жыл бұрын
There's no label about Oz or Kg to charge the Unit :/
@РемБытТехника-ф6к Жыл бұрын
But this is absolute rubbish for repairing household refrigerators. I have been professionally repairing household appliances for more than 20 years. I have tried various seals from time to time. None of them give a significant result.
@giorgosktoridis903 Жыл бұрын
Why you have to adjust the txv if it was working properly before?looking at your suction pressure and considering that the evap coil have some ice i assume you have overcharged the system.Also you dont measure superheat without cleaning the ice of the evap coil first
@ElRudy2006 Жыл бұрын
I have one similar. I plug it in and does not come on. The only noise is from the Omron GL7, the only clicks as i plug the unit. PLEASE HELP..
@josephparaskevas7375 Жыл бұрын
Hookup the water to closed loop geothermal.
@alexherrera1208 Жыл бұрын
is call omega clip 2 plastic spacer, square washer then the bracket and finish with the star washer and the final screw
@Garry90 Жыл бұрын
Thank you for your video, got one of these and trying to figure out how to fix the gaps.
@lulubliz6405 Жыл бұрын
Terrible video...not worth watching!!
@stevevelasquez3308 Жыл бұрын
How do you clear a cl alarm ?
@hotfeva9843 Жыл бұрын
Just barefaced it huh bruh
@kennethNash-e9j Жыл бұрын
it would have been a great video if you show the controller rather than your face , we could not see what you were doing
@johnkassitas4792 Жыл бұрын
You should always check power hot to natural instead of ground. It possible you lost your ground
@francisobey325 Жыл бұрын
Good job, pls can have your WhatsApp number
@trevorfernandes5569 Жыл бұрын
Is the door heater connected with the compressor… is it ON all the time or only works during defrost?