Xi 640: Unboxing | optris
4:43
4 ай бұрын
Xi 400 CM: Unboxing | optris
7:22
CSvision: Unboxing | optris
4:33
Жыл бұрын
Пікірлер
@vivianandrade235
@vivianandrade235 4 күн бұрын
I am facing a lot of issues on exporting the data. It seems that the software is exporting only the values that are in the time or temperature range of the diagram instead of exporting the complete data. Also, sometimes it exports null values! I would also like to export the time as seconds, is it possible? I am really confused on how the exportation works.. Where can I find more information?
@yusufcakroglu5524
@yusufcakroglu5524 2 ай бұрын
Is it possible to get the csv output simultaneously while the process is ongoing
@Optris
@Optris 2 ай бұрын
No, that cannot be done simultaneously. The CSV files can be created afterward, either by using the RAVI Converter or by saving them in PIX Connect. You can save the temperature-time diagram at any time or take snapshots of the entire IR image or the temperature profile. If you wants to record data during the process, it can be done either via an analog signal into a data logger or by continuously querying the COM port using serial communication. For further information regarding the PIX Connect, please contact us at +4930500197-0 or by e-mail at [email protected] Best regards your Optris Team
@dudihermawandi446
@dudihermawandi446 4 ай бұрын
please give me quotation
@Optris
@Optris 4 ай бұрын
Dear Dudihermawandi446, you can put together your offer at the following website. www.optris.com/en/product/infrared-cameras/xi-series/xi-400-cm/ As we have a selection of 4 different optics, we will have to ask you to put this together yourself or send an e-mail with your requirements to [email protected]. Best regards your Optris Team
@AdrienZ
@AdrienZ 5 ай бұрын
The Xi 400 field of view is mentioned to be 30.8 x 23.2 mm. Is it a maximum? Is it limited by the stand or the camera cannot focus to infinite distance?
@Optris
@Optris 5 ай бұрын
Hi Adrien, We offer the following optics (Field of View) for the Xi 400: 18° x 14° (f = 20) 29° x 22° (f = 12.7) 53° x 38° (f = 7.7) 80° x 54° (f = 5.7) In principle, the focus is infinite. However, for precise measurement, a pixel grid of at least 3x3 is required. You can always use our Calculator app to determine your exact measuring field: www.optris.com/en/optris-calculator/ Best regards your Optris Team
@AdrienZ
@AdrienZ 5 ай бұрын
@@Optris Thank you for your reply.
@gregoriospinelli5889
@gregoriospinelli5889 5 ай бұрын
well done! 👏
@dddavenportchannel
@dddavenportchannel 5 ай бұрын
What happened to the audio?
@Optris
@Optris 5 ай бұрын
Hi Dustin, thanks for your comment. It is indeed intentional that the audio in this video is muted after the intro to focus on our unique XI series.
@ГерманГусев-к2э
@ГерманГусев-к2э 6 ай бұрын
Good instructions, very good.
@Optris
@Optris 5 ай бұрын
Glad you liked it!
@ГерманГусев-к2э
@ГерманГусев-к2э 6 ай бұрын
Very useful for any measurements
@Optris
@Optris 6 ай бұрын
Thank you so much 😊
@ГерманГусев-к2э
@ГерманГусев-к2э 6 ай бұрын
Optris- to my mind is one of the best project in the world. My congratulations and best wishes for you and Optris.
@Optris
@Optris 6 ай бұрын
Many thanks!
@ГерманГусев-к2э
@ГерманГусев-к2э 6 ай бұрын
Excellent solutions, very good, congratulations!
@Optris
@Optris 6 ай бұрын
Thank you! Cheers!
@njaga8123
@njaga8123 6 ай бұрын
How to activate laser
@Optris
@Optris 6 ай бұрын
Hi Njaha8123, the laser can be activated/ deactivated via the programming keys on the unit or via the software. If the laser is activated a yellow LED will shine (beside temperature PIF display). At ambient temperatures >50 °C inside the electronic box the laser will switch off automatically. Hope this helps you, otherwise please send an email to [email protected] we will be happy to help you.
@ГерманГусев-к2э
@ГерманГусев-к2э 6 ай бұрын
My congratulations! Excellent results for 20 years!
@Optris
@Optris 6 ай бұрын
Thank you! Cheers!
@ГерманГусев-к2э
@ГерманГусев-к2э 7 ай бұрын
Excellent! Very good!
@wtxl2943
@wtxl2943 7 ай бұрын
Hi! I have noticed a difference when attempting to open the generated CSV files in Excel. Each number separated by a comma seems to be placed into individual cells, rather than being correctly imported as a single data point (as shown in the video, the 3D hand imagine one). Is there any way to solve this problem? Thanks.
@leocurious9919
@leocurious9919 7 ай бұрын
Is there a way to save line scan data? So the pixels of the line over time like this: Timestamp0, px0, px1, ... Timestamp1, px0, px1, ... To then look at the temperature variation over time? For example a rotating object, to scan all 360° and perhaps average or analyze the data any other way? The option "Auto snapshots" is greyed out.
@TilenZorenč
@TilenZorenč 8 ай бұрын
Can you also export alarm on output? To notify machine operators for example?
@Optris
@Optris 8 ай бұрын
Hi Tilen, the alarm signal (or the temperature value) can be output as an analogue value via the analogue output. This can be connected to a PLC controller, a siren or an alarm light. I hope this helps you. Alternatively, please send us your question again to [email protected] and we will certainly be able to help you.
@hamidashariyoun5870
@hamidashariyoun5870 8 ай бұрын
which sensor is suitable for measuring hot water inside PTFE container?
@Optris
@Optris 8 ай бұрын
Hi Hamid, should the water be measured through the PTFE? That is not possible, unless its very thin (<200 µm), which will not exist. Then simply measure the PTFE with LT device. Otherwise with LT device directly on the water if possible. For example CTfast LT or CT LT could be used. Simply contact us at [email protected] and we will be able to advise you.
@YannickDaniel-j9u
@YannickDaniel-j9u 8 ай бұрын
Is there any possibility to retrieve the time information from the exported .dat files header directly from the .ravi file? Since the windows creation / modification / etc. timestamps are broken, I need to manually extract it from a temp-time diagram which also wastes a lot of time...
@Optris
@Optris 8 ай бұрын
Unfortunately , it is not possible to retrieve the time information from the exported .dat file header direct from the RAVI file.
@YannickDaniel-j9u
@YannickDaniel-j9u 8 ай бұрын
Thank you for your very quick response @@Optris! What I do not get however is, how the PIX Connect Software would then be able to export this information? Is it simply the case that the information is in the .ravi file and you just do not want to disclose the way it could be retrieved or is it really actually not encoded in the .ravi file?
@Optris
@Optris 8 ай бұрын
@@YannickDaniel-j9u Please excuse the late reply the temperature-time diagram can be exported from the RAVi: To do this, the video file must be run through completely once in PIX connect. Then you should find the item "Save Temp/Time diagram data" under the menu item "File", which provides you with exactly this functionality. Alternatively, feel free to send us an email to [email protected].
@gabrielrodriguez8357
@gabrielrodriguez8357 8 ай бұрын
Is triggering a snapshot using code instead of a digital input pin possible?
@thermorhyme
@thermorhyme 9 ай бұрын
how can we adjust the time interval for the data? I would like to make the interval every 1 sec
@Optris
@Optris 8 ай бұрын
Hello, unfortunately, it is not possible to adjust the time interval for the data. You have only the possibility to delete the not needed lines (times) manually in the *dat file.
@llMaranathall
@llMaranathall 11 ай бұрын
Can a snapshot be taken of a certain area?
@Optris
@Optris 10 ай бұрын
Yes, it is possible to enlarge a specific area (digital zoom) and then save it as a snapshot. To do this, you have to go to the Pix connect software under Configurations --> IR Image arranging --> "Zoom" Pick rectangle for user defindes zoom: --> if the desired area is visible, an image can be created using the normal screenshot function. If anything is still unclear, please send an email to [email protected] and we will be happy to help you.
@1234567890q
@1234567890q Жыл бұрын
How is it possible to obtain the greatest resolution in the temperature time diagram of an already recorded ravi file? Currently, I have to replay the video at 1x speed to get the full resolution. It wastes so much of my time. The ravi files are also so large! Is it not possible to employ a video codec instead of storing the camera feed as uncompressed YUV frames? Thanks.
@Optris
@Optris Жыл бұрын
The resolution regarding the camera image of the recorded RAVI file will not change , if you change the speed of the replayed video But the temporal resolution changes if you speed up the video. There is currently no possibiltiy to employ a video codec instead of storing the camera feed as uncompressed YUV frames. With the software PIXConnect you can only do a capture screen and as result you will have a WMV file. Another possibility is to use the ConnectedSDK to transfer all pixels of the live image as temperature- ,color- or as ADUs matrix to your own programmed software. You can handle the data for yourself. You can find the ConnectedSDK in the software PIXConnect. For further information regarding the PIX Connect, please contact us at +4930500197-0 or by e-mail at [email protected] Best regards your Optris Team
@WickiStephan
@WickiStephan Жыл бұрын
Für Xi410 Adapterring auf Anschlag einstellen? (Das Gewinde am Kamerakopf ist länger und passt wie im Video beschrieben nicht in den Freiblasvorsatz...)
@Optris
@Optris Жыл бұрын
Hallo, auch für die Xi 410 gibt es ein entsprechendes Tutorialvideo; dieses finden Sie hier: kzbin.info/www/bejne/h4KrdKutnNyJbKs Die Xi 410 und die Xi 400 besitzen die selbe Tubuslänge und eine unterschiedliche zur Xi 80, daher kommt es zu dem, von ihnen beschriebenen Problem. Ich hoffe diese Antwort hilft Ihnen weiter, ansonsten wenden Sie sich bitte an unseren Optris Service via: [email protected]
@solcoincosas2945
@solcoincosas2945 Жыл бұрын
Hi, may you tell me whether need an special configuration to run it in the celular phone, I got it in the computer but it doesn't run on my celular phone
@Optris
@Optris Жыл бұрын
Hello, Usually, the web server function works on any smart phone. It is important that the smart phone is connected to the same WiFi network as the PC or laptop with the PIX Connect software installed. We hope that this answer helps you. If you need further help, please contact our support team via: [email protected]
@InstrumentCalibration
@InstrumentCalibration Жыл бұрын
How many maximum alarms we can do from each camera?
@Optris
@Optris Жыл бұрын
Hello, within the PIX Connect software you can create as many measurement fields as you like and link each one with an alarm (so you get an alarm message in the software). On the hardware side you can link up to 9 alarm systems to the software with our industrial process interface (PIF). I hope the answer helps you, otherwise please contact our support at: [email protected]
@InstrumentCalibration
@InstrumentCalibration Жыл бұрын
@@Optris It was a big help! Thanks for helping
@InstrumentCalibration
@InstrumentCalibration Жыл бұрын
Thanks for sharing!
@ernestd927
@ernestd927 Жыл бұрын
💕 Promo>SM
@sandaru1456
@sandaru1456 Жыл бұрын
Do you have fast moving object detecting system ?? Machine RPM is 110. So i need to detect some errors and stop machine when the identity the error..
@joseangulomaverick2277
@joseangulomaverick2277 2 жыл бұрын
Video is great, perhaps fixing the audio so it can be heard in stereo? I can only hear on right speaker
@TheGreatHammys
@TheGreatHammys 2 жыл бұрын
Thanks. Helping to choose which camera we're going to buy.
@heinrichhein2605
@heinrichhein2605 2 жыл бұрын
Where I can download the latest, I can't find any link on your website. It would be also nice if the software would have an integrated way to get the latest update, or at least to check for one. The Login for the website I got to download the software does not work anymore. Please improve the way to get the software, this is a huge pain for any customer! Thanks
@Optris
@Optris 2 жыл бұрын
Hi Heinrich Hein, Thank you for your advice and apologise for the inconvenience. We will pass it on to the appropriate departments. For further information regarding the PIX Connect and the corresponding download options, please contact us at +4930500197-0 or by e-mail at [email protected] Best regards your Optris Team
@heinrichhein2605
@heinrichhein2605 2 жыл бұрын
Is there any way to suggest some things about the software, I relay love it, and it is amazing compared to the competitor, but there are some small annoyances
@Optris
@Optris 2 жыл бұрын
Hi Heinrich Hein, Thank you for the compliment. We are always open to suggestions for improvement and optimization just contact us on +4930500197-0 or [email protected] Have a nice day and greetings from your Optris Team
@mohamedkhalil413
@mohamedkhalil413 2 жыл бұрын
I am using Optris Xi 400 and the PIF type always shows no PIF in the software, I am connecting everything like the tutorial. How can I solve the problem please
@sciroccoR
@sciroccoR 2 жыл бұрын
you say that this is one of the fastest. what is faster??
@TravelVlogRoad
@TravelVlogRoad 2 жыл бұрын
We are using model OPTCTLT15CB15
@Lexxus007
@Lexxus007 2 жыл бұрын
Hi. I do all the steps to send analog output temperature from device xi410, and I can see it correctly, but if I close PIX client the signal dissapears. "Using autonomously by device" is activated. But I can see signal fail-safe from AO even PIX client is closed. Help plz :)
@Optris
@Optris 2 жыл бұрын
Hi Алексей Михайлович, When using the Xi 410 camera, an important additional setting must be made for autonomous operation. When all the configurations have been made, it is important to write them to the device. This is done in the menu under Devices and Set configuration to device. See also the Xi operators manual, page 80. Hope this answer helps you! You can also find the user manual here: www.optris.global/xi-410 (see the manual tab) Best regards and come well into the new year, your Optris Team
@pieterkaruniadeo3494
@pieterkaruniadeo3494 2 жыл бұрын
Does the software support exporting data ? To csv maybe
@serenkzsar7494
@serenkzsar7494 2 жыл бұрын
yes, you can do this via file - save temp/time diagram data. But the video should be playing from the beginning to the end when you select to save
@ketanyogi3599
@ketanyogi3599 3 жыл бұрын
In measuring area setting there is rectangle and point option, no line option.
@Optris
@Optris 3 жыл бұрын
You can create with the software PIXConnect a temperature profile where you can see the temperature distribution on the line. You can also bind in an automatic way some measure areas on the temperature profile line. (See menue: Configuration => Temp Profiles => Bind measure areas to profile.)
@ketanyogi3599
@ketanyogi3599 3 жыл бұрын
How can I get temperature on one line from the recorded video as in measuring area setting I gen not get a line option?
@mertgulcurgs
@mertgulcurgs 3 жыл бұрын
Looks very good.
@theodorealfreda391
@theodorealfreda391 3 жыл бұрын
vxr7r vun.fyi
@mohdiqbalmustaparudin4700
@mohdiqbalmustaparudin4700 3 жыл бұрын
One more question, how much does the measurement accuracy affected if camera is installed at an angle (not perpendicular to surface)?
@Optris
@Optris 3 жыл бұрын
Hello Mohd Iqbal Mustaparudin , please contact our support via @Mail: [email protected]. Our application engineers will be able to help you with your request. Thank you very much and greetings, Your Optris Team
@asdascxs
@asdascxs 3 жыл бұрын
Is the M30 thread connection free? I intend to use this for a optical filter mount.
@Optris
@Optris 3 жыл бұрын
Hello Kenneth Meinert, please contact our support via @Mail: [email protected]. Our application engineers will be able to help you with your request. Thank you very much and greetings, Your Optris Team
@mohdiqbalmustaparudin4700
@mohdiqbalmustaparudin4700 3 жыл бұрын
Water flow only through the thicker part the cooling jacket right? Or the whole cylinder?
@Optris
@Optris 3 жыл бұрын
Hello Mohd Iqbal Mustaparudin the water flows through the entire cylinder.
@mohdiqbalmustaparudin4700
@mohdiqbalmustaparudin4700 3 жыл бұрын
@@Optris Thanks for quick reply.I assume so because it seems like the straight part of the cylinder has no gap in it. Glad you clarify it. Currently waiting to receive 2 units of this model. Is there any specific pressure limit for the water flow? 5 l/min through hose of 6 mm ID, the pressure must be quite high, right?
@Optris
@Optris 3 жыл бұрын
@@mohdiqbalmustaparudin4700 you are welcome The water flow rate is approx. 1-5l/ min. We recommend not to exceed a water flow of 5l/ min. In addition, the cooling water temperature should not exceed 30°C. Greetings, your optris team