@edgarcastaneda2459
@edgarcastaneda2459 5 күн бұрын
Hola fabian saludos si pudieras hacer un video como solusionar la alarma 12550 de 840d , o como contctarte
@edgarcastaneda2459
@edgarcastaneda2459 5 күн бұрын
Hola Fabian he estado viendo tus videos y actual mente trabajo con una cnc punch press co 840d y tengo una alarm 12550 si pudieras hacer un video como solucionarlo seria genial.
@samirarad9362
@samirarad9362 8 күн бұрын
thanks very much for your videos
@SonurajSonu-pu4mt
@SonurajSonu-pu4mt 11 күн бұрын
aap ham ko bhi sikha dijiye bhaiya
@tariknayaflm3244
@tariknayaflm3244 16 күн бұрын
thank you brother ❤️❤️❤️❤️❤️
@esatyuksel3504
@esatyuksel3504 18 күн бұрын
Merhaba ben yeni başladım mazak mazatrol matrix nexsus makinası kullanıyorum eğitim video kayıt istiyorum türküm türkçe dilinde veya alt yazılı bile olur yeterki anlıyabiliyim yardım edermisin bana ?
@jesussanchez3745
@jesussanchez3745 18 күн бұрын
Gracias por la informasion Favian
@nimaabdolrahimi606
@nimaabdolrahimi606 19 күн бұрын
Hi. I have problem with mazatrol matrix nexus 2. I have 2 errors and I don't know how fix it. 1393 R.D Relocation Detected. 1397 R.D Battery Not Mounted. Please help me to fix this 2 errors.
@FabianAchaval
@FabianAchaval 18 күн бұрын
Hi there. What machine serial number you have? Do you know the parameter where you have to enter the password to reset the alarm?
@nimaabdolrahimi606
@nimaabdolrahimi606 18 күн бұрын
Hi. I don't have a password. Can I fix this alarm inside the software of machine?for example I go in the ladder and change a something?
@nimaabdolrahimi606
@nimaabdolrahimi606 18 күн бұрын
Have you telegram or other software I can contact with you or sent video of my machine?
@shayansearch
@shayansearch 19 күн бұрын
hi. i have a problem with 2 error and i dont know how should i fix them. 1393 R.D Relocation Detection. 1397 R.D bBattery Not Mounted.
@FabianAchaval
@FabianAchaval 18 күн бұрын
Hi there. What machine serial number you have? Do you know the parameter where you have to enter the password to reset the alarm?
@shayansearch
@shayansearch 18 күн бұрын
@@FabianAchaval hi.i fix the alarm 1393 but i dont know how can i fix the 1397 error.
@Low-keyFire
@Low-keyFire 19 күн бұрын
its not showing on my controller . at manufacturer level
@Low-keyFire
@Low-keyFire 19 күн бұрын
do you have an idea about the communication nck plc failure error?
@Low-keyFire
@Low-keyFire 21 күн бұрын
hi , i have 840d sl , giving waiting for plc communication / communication to plc nc failure. i did general reset to nck and plc and loaded backup, same issue , changed plc battery . still sometimes this alarm showing , any idea please?
@alexanderstefanxandraswedi5835
@alexanderstefanxandraswedi5835 22 күн бұрын
@mariastoriano
@mariastoriano 24 күн бұрын
Hi Can I ask question how to fix the revolver of the fusion 640T theres always alarm and the revolver not work. What needs to do? Thank you..
@FabianAchaval
@FabianAchaval 24 күн бұрын
Hi @Maria, can you please send the complete alarm text? What machine model is? Is the turret/revolver hydraulic or electric? If it is electric, what servomotor has?
@FabianAchaval
@FabianAchaval 27 күн бұрын
How to clone a CNC HDD 2.5” IDE into an SSD. Image creation and cloning to SSD. Part #2 kzbin.info/www/bejne/bGS9p6iDjqqYbZo
@FabianAchaval
@FabianAchaval 27 күн бұрын
How to clone a CNC HDD 2.5” IDE into an SSD. Image creation and cloning to CF. Part #3 kzbin.info/www/bejne/bGS9p6iDjqqYbZo
@FabianAchaval
@FabianAchaval 27 күн бұрын
How to clone a CNC HDD 2.5” IDE into an SSD. Image creation and cloning to CF. Part #3 kzbin.info/www/bejne/bGS9p6iDjqqYbZo
@FabianAchaval
@FabianAchaval 27 күн бұрын
How to clone a CNC HDD 2.5” IDE into an SSD. Image creation and cloning to SSD. Part #2 kzbin.info/www/bejne/oZfEl2OHltmhb80
@rodrigonievas
@rodrigonievas 27 күн бұрын
hola fabian tenes un correo al que pueda contactarte? tengo que clonar un hhd gracias
@FabianAchaval
@FabianAchaval 27 күн бұрын
Hola Rodrigo. Fijate en esta playlist kzbin.info/aero/PL-Qx9JZP7OURFmZehEsY4qjp6bPXNdtzl. Este video tiene el listado de materiales en la descripción. kzbin.info/www/bejne/oZfEl2OHltmhb80 Espero que te sirva
@LIMGSACMECANIZADODEPIEZAS
@LIMGSACMECANIZADODEPIEZAS 28 күн бұрын
HOLA FABIAN, TENGO UN PROBLEMA CON EL BACKUP Y LOS PARAMETROS DE MI MAQUINA , ES UN OKUMA IMPACT LU45 4 EJES - OSP E100L , SE PERDIO TODO LA INFORMACION drive.google.com/drive/u/5/home drive.google.com/drive/u/5/folders/1QpaSsreOYvn_AmVZDCulgKj2q4_RjnJ5 FOTOS DEL CPU
@LIMGSACMECANIZADODEPIEZAS
@LIMGSACMECANIZADODEPIEZAS Ай бұрын
HOLA FABIAN EXCELENTES VIDEOS , TE COMENTO TENGO UN OKUMA LU 45 CON OSP E100L , PERO TENGO UN INCOVENIENTE ERROR 9900 , ALPARCER ES QUE NO ENCUENTRA INFORMACION EN EL SISTEMA
@muhammedalshameri801
@muhammedalshameri801 Ай бұрын
Hi , please can you help it keep says: there is no compared program
@istvanszep8678
@istvanszep8678 Ай бұрын
I can't download it in my country, do you have any tips how to download it?
@FabianAchaval
@FabianAchaval Ай бұрын
Not all apps for Android and Apple are available in every country. Availability can be influenced by several factors, including: 1. **Geographic Restrictions**: Some apps are restricted to certain regions due to licensing agreements, local laws, or content regulations 2. **Developer Choices**: Developers may choose to release their apps only in specific markets where they see the most potential or where they have the necessary resources to support the app 3. **Platform Policies**: Both Google Play Store and Apple App Store have policies that can limit app availability based on content, security, and compliance with local regulations For example, Apple services like the App Store, Apple Music, and Apple Arcade are available in many countries, but not all. Similarly, Android apps can also face restrictions depending on the country.
@FabianAchaval
@FabianAchaval Ай бұрын
If you’re having trouble accessing the app, you might want to check the Google Play Store or Apple App Store for your region. Sometimes, using a VPN can also help access apps that are restricted in certain areas, but this should be done in accordance with local laws and regulations.
@jordanrios8396
@jordanrios8396 Ай бұрын
Gracias por compartir tus conocimientos!
@mfiame1
@mfiame1 Ай бұрын
All I am getting is data not found even though it shows that it is on the card.
@LIMGSACMECANIZADODEPIEZAS
@LIMGSACMECANIZADODEPIEZAS Ай бұрын
HOLA FABIAN BUENOS DIAS , QUISERA HACERTE UNAS CONSULTAS TENGO U OKUMA LU 45 IMPACT - A DONDE PUEDO ENVIARTE LA FOTO DE LA PANTALLA QUE ME SALE drive.google.com/file/d/1kltwvXe_eXLV0d7_4VN9xwFe6DvbVlw7/view?usp=sharing
@LIMGSACMECANIZADODEPIEZAS
@LIMGSACMECANIZADODEPIEZAS Ай бұрын
drive.google.com/file/d/1kltwvXe_eXLV0d7_4VN9xwFe6DvbVlw7/view?usp=sharing
@ZeeshanHaider-ef9cu
@ZeeshanHaider-ef9cu Ай бұрын
Sir please help me error ex1047 machine spec.param.cleared
@FabianAchaval
@FabianAchaval Ай бұрын
@@ZeeshanHaider-ef9cu The **EX-1047 alarm** on FANUC controllers typically indicates that the machine's **special parameters have been cleared**. This can happen due to issues like battery failure, which leads to the loss of all parameters. To resolve this, you usually need to reload the parameters and sometimes enter a password to access and rewrite specific parameters. Depending upon your CNC model, maybe you have an AUTO BACKUP routine then you could recover the CNC from there. Hope it helps
@ZeeshanHaider-ef9cu
@ZeeshanHaider-ef9cu Ай бұрын
Hello sir thanks to reply please make the video for error ex1047 thanks again
@PremtonThaqi
@PremtonThaqi Ай бұрын
Hi While i was configuring network on 840D SL control for program back ups. I some how messed it up and won't be able to boot it now. On machine startup i am getting the following error displayed on TCU. “startstop.sh: line 25: /siemens/common/tcu/nonfree/startvnc: not found”
@FabianAchaval
@FabianAchaval Ай бұрын
@@PremtonThaqi The error message **"startstop.sh: line 25: /siemens/common/tcu/nonfree/startvnc: not found"** on the Sinumerik 840D SL typically indicates that the system is unable to find the `startvnc` script, which is necessary for starting the VNC server. This issue often arises during network configuration or after changes to the system's IP settings Here are a few steps you can try to resolve this issue: 1. **Check the File Path**: Ensure that the `startvnc` script exists in the specified directory. If it doesn't, you may need to restore it from a backup or reinstall the necessary software package. 2. **Network Configuration**: If the error occurred after changing network settings, try reverting to the original settings. You might need to use a USB bootable disk to reset the IP address to its previous state 3. **Consult Documentation**: Refer to the Sinumerik 840D SL manual or Siemens support documentation for specific instructions related to this error. Is there a specific change you made before encountering this error? That might help narrow down the solution. Here you are with some useful resources: (1) Configuring company network with 840d sl - Siemens. support.industry.siemens.com/forum/WW/en/posts/configuring-company-network-with-840d-sl-can-t-restart-machine/198352. (2) Boot error on startup, 840D SL control - 313182 - Industry Support Siemens. support.industry.siemens.com/forum/WW/en/posts/boot-error-on-startup-840d-sl-control/313182. (3) NO connection with PLC/NC - 840D sl - 186140 - Siemens. support.industry.siemens.com/forum/ww/en/posts/no-connection-with-plc-nc-840d-sl/186140. (4) SINUMERIK 840D: machine does not start and getting error ... - Siemens. support.industry.siemens.com/forum/ww/en/posts/sinumerik-840d-machine-does-not-start-and-getting-error-message/264679.
@PremtonThaqi
@PremtonThaqi Ай бұрын
@@FabianAchaval Thank You . And I need to know why it comes : Over time when reading Upon reading access /NC/_N_NC_TEA_ACX/$MNS_SPIND_POWER_RANGE[1] a time exceeding occurred. The cause may be a bottleneck of communication resources To repeat the read access, press the softkey 'Repeat'. To continue the process with access error 'time exceeding', press it Softkey 'Continue' To potentially eliminate the potential congestion of communication resources, it must HMI is restarted, press the softkey 'HMI Restart'.
@marinobikes
@marinobikes Ай бұрын
Whow exelente , probaré en mi máquina Gracias
@marinobikes
@marinobikes Ай бұрын
Por cierto excelentes videos , estoy pasando de masatrol a fanuc y me sirve mucho tus videos Gracias 🎉
@FabianAchaval
@FabianAchaval Ай бұрын
@@marinobikes me alegro de saber que te sirvan
@marinobikes
@marinobikes Ай бұрын
Hola para fanuc oi-Td alguna clave , intenté y nada, tengo problemas con el sensor de agua, trabaja unos minutos y alarma de flujo , quizá en el lader pueda bloquear o mover su configuración 🙏
@FabianAchaval
@FabianAchaval Ай бұрын
@@marinobikes fíjate en este video. En las series de los CNC mas nuevos la password son solo los números que se encuentran después de la primera letra del drawing number kzbin.info/www/bejne/n5mUhYaoeap5acUsi=QGhsfr0FjGuhGjxF
@marinobikes
@marinobikes Ай бұрын
​@@FabianAchaval muchas gracias Saludos desde Perú 🇵🇪
@victorvaldivia9472
@victorvaldivia9472 Ай бұрын
Hola podrías explicar cómo configurar la hora
@gilson6396
@gilson6396 Ай бұрын
Hi sir can you please help me on how to do api thread rechase on moriseiki SL 603 D lathe.thanks
@FabianAchaval
@FabianAchaval Ай бұрын
Performing an API thread rechase on a Mori Seiki SL603 D lathe involves several steps. Here’s a general guide to help you get started: 1. **Preparation**: - Ensure the lathe is properly set up and calibrated. - Verify that the correct threading tool and inserts are installed. - Check the machine's parameters and settings for threading operations. 2. **Setting Up the Threading Operation**: - Load the workpiece securely in the chuck. - Set the spindle speed and feed rate according to the material and thread specifications. - Program the lathe for the specific API thread you need to rechase. This involves inputting the correct thread pitch, depth, and other parameters into the CNC control. 3. **Executing the Threading Operation**: - Start the lathe and monitor the initial cuts to ensure the threading tool is cutting correctly. - Make multiple passes to gradually achieve the desired thread depth. This helps in maintaining precision and avoiding tool wear. - Use a thread gauge to check the thread dimensions periodically. 4. **Finishing Up**: - Once the thread is rechased to the correct specifications, stop the lathe and remove the workpiece. - Inspect the thread for any defects or irregularities. - Clean the workpiece and the lathe to remove any metal shavings or debris. For more detailed instructions, you might want to refer to the machine's manual or consult with a technician familiar with the Mori Seiki SL603 D lathe
@gilson6396
@gilson6396 Ай бұрын
@@FabianAchaval thanks sir
@rameshpatel3872
@rameshpatel3872 Ай бұрын
I keep getting Himem or emm386 error.
@FabianAchaval
@FabianAchaval Ай бұрын
An EMM386 error typically occurs when there's an issue with the memory manager in DOS or early versions of Windows. Here are some common causes and solutions: 1. **Missing or Corrupt Files**: - Ensure that both `himem.sys` and `emm386.exe` are present on your system. You can check this by typing the following commands at the DOS prompt: ```plaintext cd\ cd windows dir himem.sys dir emm386.exe ``` - If either file is missing, you can copy them from another computer or a bootable floppy diskette¹. 2. **Conflicting Data in Autoexec.bat or Config.sys**: - Conflicts in these files can cause errors. Try renaming them and rebooting: ```plaintext cd\ ren autoexec.bat autoexec.ch ren config.sys config.ch ``` - If the issue persists, boot the computer step-by-step by pressing F5 during startup and identify the problematic line. 3. **Corrupt Files**: - The `himem.sys` or `emm386.exe` files might be corrupt. Replace them with known good versions from a bootable diskette or another computer. 4. **Memory Issues**: - Faulty or corrupt memory can also cause these errors. Boot from a known good bootable diskette that loads `himem.sys` and `emm386.exe`. If the error persists, it might indicate a hardware issue with your computer's memory or motherboard.
@tahaerenucar5146
@tahaerenucar5146 Ай бұрын
Son kısımda ne yaptığını anlamadım 😊
@obertorivas
@obertorivas Ай бұрын
Excellent very useful.
@maxencebegue8920
@maxencebegue8920 Ай бұрын
Hello, I used your videos a lot, they are very well done. I recently bought a MORI SEIKI M-300L CNC with a series 16 fanuc controller, but I'm having trouble getting it up and running again. Maybe you can help me. I can't change the operating mode, I'm stuck in MDI mode. I don't know if it's a problem linked to the settings or a wiring fault? Thanks in advance
@FabianAchaval
@FabianAchaval Ай бұрын
If your FANUC 16T CNC is stuck in MDI mode and cannot change operating modes, there are a few potential causes and solutions to consider: 1. **Emergency Stop (E-Stop)**: Ensure that the machine is not in an emergency stop condition. Sometimes, being in E-Stop can lock the machine in MDI mode. 2. **Parameter Settings**: Incorrect parameter settings, especially in the 900 series, can cause issues with mode changes. Verify that all parameters are correctly set according to the machine's documentation. 3. **Power Supply Issues**: A faulty power supply can prevent the machine from changing modes. Check for any blown fuses or power supply issues. 4. **Mode Selector Switch**: Ensure that the mode selector switch is functioning correctly. Sometimes, the switch itself can be faulty. 5. **PMC Configuration**: The PMC (Programmable Machine Controller) configuration might be incorrect. This can affect the machine's ability to change modes. Verify the PMC parameters and ensure they match the hardware configuration. 6. **PMC LADDER**: Check the PMC LADDER logic for the operating modes change. Make sure the inputs are working fine, and look for missing conditions
@maxencebegue8920
@maxencebegue8920 Ай бұрын
@@FabianAchaval thank you for your reply. There is no 900 series in the "parameters setting", did you mean to write 9000? But I think that the cause must come from the power supply as all the other points have been checked with the manuals. In addition, there's also a problem with the parameters being saved when the power is switched off for too long. A bad power supply would explain these 2 problems.
@marioevergarcia486
@marioevergarcia486 Ай бұрын
Hola buena noche, como te puedo contactar para un servicio remoto es parabun okuma con osp200
@ferhatsaifi
@ferhatsaifi Ай бұрын
Hi brother I would like to ask one question? Are there anyway to look the cnc program in main time keep access to the GUD machine data . Because what happen in our case our process we use robot to laod and unload the product, some times while process going on operator puch reset button and the process intrepted. To restart again to full automatic need to send robot to home position. that can be done only through modify robot parameter in the GUD . when I locked the CNC program by made user or manufacturer also operator can not reach the GUD and setup7. I wish you can understand me what I mean. Your support will be appreciated thank you.
@FabianAchaval
@FabianAchaval Ай бұрын
@@ferhatsaifi To restart a program on the Sinumerik 840D from where it was left after pressing reset, you can follow these steps: 1. **Switch to AUTO mode**: Ensure that the machine is in AUTO mode. 2. **Select "Correct Program"**: There should be an option to "Correct Program" on the screen. 3. **Use the "Search" or "Go to..." function**: Press the soft key labeled "Search" or "Go to...". 4. **Enter the line number (N value)**: Enter the N value (line number) where you want to restart the program. For example, if you want to start from line N20, enter N20. 5. **Cycle Start**: After moving to the desired line, press the Cycle Start button to resume the program from that point This method ensures that the program resumes from the correct position without missing any important parameters or causing potential issues. (1) How can I re-start the program? - Practical Machinist. www.practicalmachinist.com/forum/threads/how-can-i-re-start-the-program.309374/.
@ferhatsaifi
@ferhatsaifi Ай бұрын
@@FabianAchaval thank you For your reply. But sorry my English is not understandable. But I am talking about programs protection. 🔒 Locking programs and keeping GUD global user data opening.
@luisdarianperezhugle750
@luisdarianperezhugle750 Ай бұрын
GRACIAS CON ESTE VIDEO SE PUDO CONFIGURAR NUESTRO MAGAZINE DE UN CENTRO MAZAK NEXUS 510CII
@FabianAchaval
@FabianAchaval Ай бұрын
@@luisdarianperezhugle750 me alegro que te haya servido. Saludos
@TheViviMeireles
@TheViviMeireles Ай бұрын
Thank you
@FabianAchaval
@FabianAchaval Ай бұрын
@@TheViviMeireles you’re welcome
@belmouzounamohamed671
@belmouzounamohamed671 Ай бұрын
​@@FabianAchavalhi brother plz can i have your N whatssapp or email . Im leader team maintenance in morroco
@Parey0921
@Parey0921 Ай бұрын
hi may i know how to change the drive? is it plug and play or need to back up the paramater then reupload? If thats the case what parameter should i back up. We have problem on the z axis drive and alarming with 3D. Thanks
@FabianAchaval
@FabianAchaval Ай бұрын
@@Parey0921 as long as you replace the drive with same part number, you don’t need to do anything. Parameters are uploaded automatically during booting process. Always make a backup before you do any kind of maintenance. Regards.
@Parey0921
@Parey0921 Ай бұрын
@FabianAchaval Allright just plug and play right? also any idea on 3D alarm on the drive?
@FabianAchaval
@FabianAchaval Ай бұрын
Correct! Any video to see the alarm when is triggered and alarm details?
@Parey0921
@Parey0921 Ай бұрын
@FabianAchaval the alarm saying that power supply voltage error at accel/decel, just wierd because even though the machine is on idle and not running the alarm keeps popping up, by the way it's the Z axis drive.
@FabianAchaval
@FabianAchaval Ай бұрын
@Parey0921 what exactly the alarm text is? Including number and any code shown in the alarm text on the alarm page.
@trnibobeysehirkangaldog8134
@trnibobeysehirkangaldog8134 2 ай бұрын
1183 alarım yardım edermisiniz
@FabianAchaval
@FabianAchaval 2 ай бұрын
Hi there. Hope this helps. 1183 MCS Full-closed APA error Difference between the full-closed loop encoder value and the motor encoder value exceeds the allowable range. [Object] Axis name or none (spindle) [Character-string] None [Code] Number of times the error has been detected [Probable Faulty Locations] - Synthetic offset data is not set at the full-closed loop encoder or wrong data is set. - ABSO SCALE or position encoder with shaft - Excessive lost motion in axis drive system (The motor is not rigidly connected with the movable part.) - Slippage or breakage of shaft belt - Loose coupling between motor and ball screw - Improper positional loop gain (too high)
@josecarloshernandezvazquez6857
@josecarloshernandezvazquez6857 2 ай бұрын
Una pregunta si se cambio la bateria a un cnc y sigue perdiendo los parámetros a que puede deberse, el cnc tiene un control un mazatrol 640T, los parámetros se borran cada vez que se desenergiza la máquina
@FabianAchaval
@FabianAchaval 2 ай бұрын
@@josecarloshernandezvazquez6857 hola. Que batería cambiaste? La que está en la placa fuente de la CPU detrás del monitor? Si es así, esa placa fuente suele tener este tipo de problemas si es de las primeras versiones. Qué voltaje tiene la batería que montaste?
@josecarloshernandezvazquez6857
@josecarloshernandezvazquez6857 2 ай бұрын
@@FabianAchaval hola gracias por responder, ya solucione el problema, el CPU se mando a reparar y cuando me lo entregaron para cargarle los parámetros pasaba eso, se le cambió la batería su voltaje es de 3.6 V, la solución retire la tarjeta y volví a colocarla, con eso ya no perdió parámetros la verdad desconozco que paso ahí
@marinobikes
@marinobikes 2 ай бұрын
Muchas gracias ,bien explicado
@FabianAchaval
@FabianAchaval Ай бұрын
@@marinobikes gracias por tus palabras. Saludos
@user-qj3bx7tk6g
@user-qj3bx7tk6g 2 ай бұрын
Hello sir can you tell me the solution on.my Siemens sinumerik showing no tool selected/ no tool command with tool change command,[ read in disable][ DB1600.DBX10.1]. Please help me sir
@FabianAchaval
@FabianAchaval Ай бұрын
The user interface in DB1600 offers the option of displaying fault and operating messages on the HMI. The firmware evaluates the signals that have been entered and sends these as coming and going alarms and messages to the HMI where they are displayed. The HMI manages the fault texts. Since these are user alarms, what I can only advise you is that you should open the ladder logic and track back the signal DB1600.DBX10.1 which makes the alarm 700081. Most probably, I'm just guessing, is related to tool chance sequence and you are missing an input signal from the turret or whatever mechanism you have to change tools. Usually, tools positions are given by sensors or absolute encoders that provides binary or gray code or similar to the PLC stating which is the tool number. Hope this helps.
@riteshpatel6236
@riteshpatel6236 2 ай бұрын
Thank you sir ❤❤
@FabianAchaval
@FabianAchaval Ай бұрын
@@riteshpatel6236 glad it helps you
@mariohenriquedasilvabarbos9408
@mariohenriquedasilvabarbos9408 2 ай бұрын
How do you save the ladder
@FabianAchaval
@FabianAchaval 2 ай бұрын
Hi there. Pls check this video. Hope it helps. kzbin.info/www/bejne/hZXbkohsbceDodk
@tariknayaflm3244
@tariknayaflm3244 2 ай бұрын
have you any idea how to find ladder or diagnostic page on M730BM mitsubishi (MAPPS) controller, there's no maintenance or diagnistic button, i search and no thing appear
@FabianAchaval
@FabianAchaval Ай бұрын
@@tariknayaflm3244 I try to make a video as soon as I have the opportunity
@tariknayaflm3244
@tariknayaflm3244 2 ай бұрын
thank you, this is so mush values informations about celos , first one in internet explain it , god blesse you 🤍
@FabianAchaval
@FabianAchaval Ай бұрын
@@tariknayaflm3244 thank you for your appreciation. Regards