Pro-Flex Underground Gas Fittings
3:12
Pro-Flex Fitting, quick and easy
1:31
Hearthmaster; By Pro-Flex
1:30
4 жыл бұрын
Pro-Flex CSST and Product Overview
6:05
Пікірлер
@spawny4205
@spawny4205 14 күн бұрын
will this work for shop air?
@williamyates6335
@williamyates6335 21 күн бұрын
Why does the pro-flex website training say 3/4 to full turn with wrench & this video says 1/4 to 1/2? Which is correct?
@williamyates6335
@williamyates6335 21 күн бұрын
After finishing the training, there was a specific question with 3/4 to full turn being the correct answer, so I guess I answered my own question. I'm surprised the company hasn't corrected this video.
@davem3789
@davem3789 29 күн бұрын
I installed a couple of runs of the black version about 4 years ago. It was as simple as shown and a very nice system, IMO. I did buy the Pro-Flex cutter, which is very nice as well. Got everything at Menards.
@roccoholliday779
@roccoholliday779 Ай бұрын
Can these fittings be removed and replaced if leaking
@alabamaperformancetint4620
@alabamaperformancetint4620 Ай бұрын
Is there a fitting that would allow me to tie into a 5/8 copper line with a flare fitting to continue on then with the Pro Flex to run to a Natural Gas Tank? This would keep me from having to replace all the copper, I am needing to move my tank further out
@birdkeepita1816
@birdkeepita1816 20 күн бұрын
You have a jic flare fitting like a dryer? If so get a coupler and go from 5/8 up to 3/4 npt female or male and boom you home run
@alabamaperformancetint4620
@alabamaperformancetint4620 20 күн бұрын
@ Thank you
@PigsOnBook
@PigsOnBook Ай бұрын
Thanks. I'm having trouble locating that male to male fitting at Lowes. Where to buy it? Closest thing I can find is, PFMF1212. Actually, if I do google image search, I I cannot seem to find images showing PFMF1212 disassembled. If I'm reading correctly, the PFMF1212C has 1/2 male thread nipples on both sides like this video, and, if needed, an inside 3/8 thread female. Great videos!
@DavidGawel
@DavidGawel 3 ай бұрын
what is the actual OD size of the 1 1/2"?
@69sixguns
@69sixguns 3 ай бұрын
i just got a new tank installed i had the pro flex on there he argued with me about the 1/4 to half turn and he cranked the fitting down
@user-us4dj9tv7j
@user-us4dj9tv7j 3 ай бұрын
I learned gastite and got certified 25 years ago and this stuff is way better. No chance of a burr making a leak at the connection and ruining the fitting. A burr in stainless from the flare will dig right in to the brass fitting. Never using gastite again.
@jimmoorhead9949
@jimmoorhead9949 5 ай бұрын
Price of gas compressions fittings
@EricMinter-fn7bn
@EricMinter-fn7bn 6 ай бұрын
Can you reduce the size of the pipe of origin or must you run the same diameter throughout? I haven’t found a reduction solution which is very odd to me.
@marcusaurelius9631
@marcusaurelius9631 6 ай бұрын
I do not recommend this product. If you are not a licensed Master Gas fitter you should NOT be doing gas work. Everything he says about metal to metal fittings is a crock of malarkey. They are by far a far superior product to proflex. I cant count the number of times I have found this crap with leaks all over it. Do not do gas work yourself!!! You are going to blow something up or burn it down and God forbid maime or kill somebody. Use and expert who is licensed and insured to install gas lines and I wouldnt give two cents for proflex gas line. Ask them to provide or show you their license too. I cant count the number of times of found leaks or incorrect fittings not apporved for pressurized gas that were installed by plumbers or homeowners that had no business doing gas work. Never let a plumber or electrician do gas work unless they are certified and licensed and insured!!! And I am a licensed Master Gas Fitter with 23 years of experience. Ive seen damn near eveything but still find ridiculous and dangerous stuff that people had no business doing all the time.
@PJBeee
@PJBeee 4 ай бұрын
I beg to differ. Pro-Flex CSST is not crap. I read the instructions carefully, got the card (I know, it's not hard to get that card), but my pipe and fittings all passed the town inspector's pressure test with flying colors (no drop in pressure at all). But I do agree that you had better know what you're doing with this stuff! Gas is dangerous. BTW when doing the work, which also included running 50 feet of 1" black pipe, I found a tiny gas leak on the utility side of the meter that had probably been there for years. The gas company tech thanked me for finding it and fixed it in a jif. And I had full permits for both the electrical and gas work that I did (installing a standby generator). It's now over 2 years later and no leaks of any kind. Also, to repeat what I've said before, Flak-Jacket insulation is pretty tough stuff. Obviously not as tough as black pipe, but neither are the flexible dryer and range hoses, which aren't as tough as Flak-Jacket. Just sayin'.
@marcusaurelius9631
@marcusaurelius9631 4 ай бұрын
@PJBeee and your credentials are what exactly?? That you installed it one time?
@PJBeee
@PJBeee 4 ай бұрын
@@marcusaurelius9631 No. I've installed it two times. And I would have the same comments if I'd installed it 100 times.
@davidgrove6210
@davidgrove6210 7 ай бұрын
Better product and better pricing than GasTite. I will never use that GasTite crap again
@tophatt5706
@tophatt5706 8 ай бұрын
My kits come with 4 pieces, not 3. There's an additional washer the jagged end makes contact with.
@PJBeee
@PJBeee 4 ай бұрын
Just checked with the Pro-Flex people. The fourth piece is a "high-temperature gasket." It was pre-installed in my fittings when I received them new. In the replacement ring/gasket kit, there is a new gasket included. Maybe newer fittings come with it separately.
@matthewedwardsnyder
@matthewedwardsnyder 8 ай бұрын
Thanks
@gabaknegocios
@gabaknegocios 9 ай бұрын
your URL you left in the video description does not work
@AlexGicharu
@AlexGicharu Жыл бұрын
I am in Kenya and I want to learn more abt this and I have a shop I am gas vendor so I want to advance in the business
@nspro931
@nspro931 Жыл бұрын
What was wrong with the old stab type fittings that have been used for decades? We tried some Homeflex once and said never again, this stuff looks no different.
@donnabates-holmes8120
@donnabates-holmes8120 Жыл бұрын
I don't want to give you a thumbs up I don't want to give you a thumbs down I don't hate you I don't like you what I hate about it is that I can't get it because I cannot find you anywhere I cannot find the stuff to buy it I would like to be able to buy it too but why how come because you think South doors can't do it themselves wow how idiotic you're just like the collie pictures off because you don't want nobody else to see it
@guanoApe
@guanoApe Жыл бұрын
Thanks Buck
@swamplandoutdoors
@swamplandoutdoors Жыл бұрын
You talk to much we just wanna see how to do it, no history lessons or abc school scenarios. Less talking more walking
@edbouhl3100
@edbouhl3100 Жыл бұрын
If for some reason you needed to put 2 runs of CSST in the same trench, is there a required or suggested separation distance?
@Pembroke1
@Pembroke1 Жыл бұрын
Fantastic demonstration model. Can you use this product for propane lights indoors or would it be best to use Copper?
@Pembroke1
@Pembroke1 Жыл бұрын
Well I am going to hook up LP at cabin and I couldn't think of anything better to install.
@Pembroke1
@Pembroke1 Жыл бұрын
Fantastic 🤩
@mikegomez5796
@mikegomez5796 Жыл бұрын
The stuff that Lowe's carry says 5 psi max? Is this true? How can u test it with 15 psi if this true?
@YouTubeUserNumber1
@YouTubeUserNumber1 Жыл бұрын
That's just what it's been certified for. He cranked it up for this demo to show how good the fittings are with hand tighten only.
@PigsOnBook
@PigsOnBook Ай бұрын
their website pdf also says 5 psi. But testing up to 40psi is supported they say. But they also say to "when testing at pressures above 7.5 PSIG-ensure regulators, ball valves, and appliances are removed or bypassed during testing." for the 25 ft 1/2 pipe. What needs more than 5 psi, is my remaining question, I was ready to buy until I saw the 5 psi at Lowes. Regarding Tankless water heater and Mr Heater wall heater and furnace, and comparing to steel pipe, or using this with some black steel as part of main incoming trunk line.
@nickdeliso7026
@nickdeliso7026 Жыл бұрын
So I’m running this thru the attic, and down an outside wall, connecting to galvanized pipe. Do I need the stub out to go thru the wall to stove?
@YouTubeUserNumber1
@YouTubeUserNumber1 Жыл бұрын
Galvanized pipe should not be used for fuel gas systems.
@nickdeliso7026
@nickdeliso7026 Жыл бұрын
@@KZbinUserNumber1 Down in Florida black pipe will rust quickly. Galvanized is code here. Go figure.
@YouTubeUserNumber1
@YouTubeUserNumber1 Жыл бұрын
@nickdeliso7026 interesting, I thought code prohibited galvanized everywhere in the US since it can flake. We just paint the black pipe on the west coast and it holds up. Cheers
@nickdeliso7026
@nickdeliso7026 Жыл бұрын
@@KZbinUserNumber1 That was my plan, but I called the county and was told that was how it had to be. Had to return all the black pipe and buy galvanized. The rain and constant humidity down here is brutal. Thanks!
@oilhammer04
@oilhammer04 2 жыл бұрын
I like that system. Hooking up the tubing to the Pro-Flex termination flange, I had some trouble getting the male threads started into the female nut (the flange). I had to use some copper tubing with a 90 degree bend in it to push hard against the o-ring to get the threads started. The copper tubing helped straighten the CSSI tube while I got the threads started.
@garrysingh9038
@garrysingh9038 2 жыл бұрын
Hi can we use grey quick connect natural gas barbecue hose to natural gas cooktop?
@thebigroy
@thebigroy 2 жыл бұрын
For Flak Jacket do you need to bond it to the panel? I really like that you have to worry less about electric issues with this black version.
@moevice8933
@moevice8933 2 жыл бұрын
Where do you purchase the o-ring loader?
@PJBeee
@PJBeee 4 ай бұрын
@@moevice8933 completely unnecessary. Use gloves if you think you'll get cut.
@joshuamoore24_7
@joshuamoore24_7 2 жыл бұрын
I would stick to using wrought iron or gas tite. That o ring on pro flex seems like a weak point that could leak.
@robertbrown6311
@robertbrown6311 2 жыл бұрын
I bought the kit.......why doesn't the slide ring fit over the supplied hose?
@A.C.71
@A.C.71 2 жыл бұрын
Can the fittings be taken apart and reused again after an install without the need to buy new guts inside the fitting ? basically are the fitting reusable as they come?
@rikardoneubauer3128
@rikardoneubauer3128 Жыл бұрын
I guess nobody cared to answer. That speaks volumes to me!
@martinauley
@martinauley 2 жыл бұрын
I can't find the product anywhere; particularly the 1" dia size. Anyone know where there is a source in Olympia Wa?
@njhannan
@njhannan 2 жыл бұрын
Thermal, Geary Pacific, Airefco
@siahmanjoe
@siahmanjoe 2 жыл бұрын
It's not a bad product but it is a one time use so please stop using this as unions, sincerely plumbers everywhere 👍🏻
@jimmyjams5
@jimmyjams5 2 жыл бұрын
I've zero issues disconnecting and reconnecting when working on the unit? Deff not a 1 time use. Lighter leak tested and all.
@PJBeee
@PJBeee 4 ай бұрын
I don't get your point. Unions are probably more likely to leak than Flak-Jacket, when properly installed. The point of CSST, of course, is that it's flexible. It certainly ain't cheap.
@dastick66
@dastick66 2 жыл бұрын
I need help. Will be running Proflex thru attic, and come out the eaves. What do I need and how do I connect to black pipe so I can come down to wall to propane tank? Thanks in advance. NAD
@pro-flex7142
@pro-flex7142 2 жыл бұрын
There are several ways to transition to black pipe. Given your scenario I might suggest using a stub out to transition past the eaves and tie into black pipe at that point. Feel free to give us a call should you have any questions during the process.
@dastick66
@dastick66 2 жыл бұрын
@@pro-flex7142 Thank you. Can you let me know exactly what parts I need to order? Much appreciated.
@pro-flex7142
@pro-flex7142 2 жыл бұрын
@@dastick66 Might be easiest to give us a call.
@dastick66
@dastick66 2 жыл бұрын
@@pro-flex7142 what number do I call and who do I speak with? Thank you!
@browngreen933
@browngreen933 2 жыл бұрын
How come my Pro-Flex tubing is yellow and this stuff is black?
@elliotlindsley2570
@elliotlindsley2570 2 жыл бұрын
Could be Flak Jacket? Arc-resistant alternative to standard Pro-Flex.
@browngreen933
@browngreen933 2 жыл бұрын
@@elliotlindsley2570 Yes, I think you're right, thanks!
@Rico-Suave_
@Rico-Suave_ 2 жыл бұрын
Watched
@tracker1ify
@tracker1ify 2 жыл бұрын
If another trade bumping it is going to make it leak then it ain't very good to start with
@PJBeee
@PJBeee 4 ай бұрын
"Bumping it" is not going to make it leak. Nor is "bumping" the corrugated hose between your stove or dryer and the gas supply. But you should not be surprised that it's not as tough as black pipe.
@victorcontreras348
@victorcontreras348 2 жыл бұрын
What do I use to cut the flex pipe?
@pro-flex7142
@pro-flex7142 2 жыл бұрын
Pro-Flex offers a stainless steel tubing cutter, however, any tubing cutter you have would work just fine.
@augustreigns9716
@augustreigns9716 2 жыл бұрын
thank you
@greganderson1681
@greganderson1681 2 жыл бұрын
Getting some tomorrow. Never using homeflex again.
@isaacmoffett5799
@isaacmoffett5799 3 жыл бұрын
I love this stuff. So easy to work with.
@PJBeee
@PJBeee 3 жыл бұрын
Stuff works great. My experience with the 1" (Flak-Jacket), however is that the split ring (first washer in) does not go easily into the collet. You just might need to force the collet over it with a screwdriver, and it's OK to do this without the 2nd washer or O-ring being installed. You can then test that the collet screws at least loosely onto the fitting, and then unscrew from the fitting and install the solid washer and O-ring. And of course, the split washer has nothing to do with the gas seal itself - the O-ring mate-to-fitting does that - so go ahead and force the split ring in. I've not had any leaks of any kind. But the 1" Flak-jacket stuff is pretty stiff, so be prepared to spend some time putting the fittings on, which includes the time to remove some of the jacket, as the instructions say. Otherwise, real happy with the stuff. The Flak-Jacket is reassuringly tough, so it should work well for many years. For my uses, it eliminated the need for some elbows, which reduce the effective pipe length, for specific nipple lengths, and for unions, which can leak.
@eusebiobatan
@eusebiobatan 4 ай бұрын
Cslofdbyoul
@eusebiobatan
@eusebiobatan 4 ай бұрын
Carlos yulo
@leomerlovaz
@leomerlovaz 3 жыл бұрын
2:47
@sandwichfiend686
@sandwichfiend686 3 жыл бұрын
I purchased 1/2 flak jacket from Menards but none of the 1/2" fittings slide on the way you showed it. The tubing is too thick. Should I remove 10 valleys instead of 4 so it'll fit on?
@anthonystella1819
@anthonystella1819 2 жыл бұрын
It's been 9 months since your post... what did you end up doing? I am having the same issue.
@sandwichfiend686
@sandwichfiend686 2 жыл бұрын
@@anthonystella1819 I called the hotline number and apparently they changed their design (even though they say they have never changed the design) but inventory doesn't turn over quickly and many stores still have the old stock. Yes, you just cut away the extra valleys and it does the trick.
@f.j.g.j.6563
@f.j.g.j.6563 3 жыл бұрын
No hablo mucho inglés pero te entendí! 👍
@kevinhornbuckle
@kevinhornbuckle 2 жыл бұрын
Es facil.
@pughbear9145
@pughbear9145 3 жыл бұрын
Will I still have to use dope or does this eliminates that step?
@PJBeee
@PJBeee 3 жыл бұрын
No dope or tape of any kind is needed, nor should it EVER be used on the CSST itself. Only on the NPT fittings should you use dope, tape, or whatever you usually use. For me, Pro-Dope works like a charm all by itself. (I don't get anything from anyone for mentioning it by name, and I have used it for years on gas pipe).
@raylongoria7178
@raylongoria7178 3 жыл бұрын
Coooolllll! Thank you!