2 Esdras 7:75 I answered and said, "If I have found favor in thy sight, O Lord, show this also to thy servant: whether after death, as soon as every one of us yields up his soul, we shall be kept in rest until those times come when thou wilt renew the creation, or whether we shall be tormented at once?" 76 He answered me and said, "I will show you that also, but do not be associated with those who have shown scorn, nor number yourself among those who are tormented. 77 For you have a treasure of works laid up with the Most High; but it will not be shown to you until the last times. 78 Now, concerning death, the teaching is: When the decisive decree has gone forth from the Most High that a man shall die, as the spirit leaves the body to return again to him who gave it, first of all it adores the glory of the Most High. 79 And if it is one of those who have shown scorn and have not kept the way of the Most High, and who have despised his law, and who have hated those who fear the Most High -- 80 such spirits shall not enter into habitations, but shall immediately wander about in torments, ever grieving and sad, in seven ways. 81 The first way, because they have scorned the law of the Most High. 82 The second way, because they cannot now make a good repentance that they may live. 83 The third way, they shall see the reward laid up for those who have trusted the covenants of the Most High. 84 The fourth way, they shall consider the torment laid up for themselves in the last days. 85 The fifth way, they shall see how the habitations of the others are guarded by angels in profound quiet. 86 The sixth way, they shall see how some of them will pass over into torments. 87 The seventh way, which is worse than all the ways that have been mentioned, because they shall utterly waste away in confusion and be consumed with shame, and shall wither with fear at seeing the glory of the Most High before whom they sinned while they were alive, and before whom they are to be judged in the last times. 88 "Now this is the order of those who have kept the ways of the Most High, when they shall be separated from their mortal body. 89 During the time that they lived in it, they laboriously served the Most High, and withstood danger every hour, that they might keep the law of the Lawgiver perfectly. 90 Therefore this is the teaching concerning them: 91 First of all, they shall see with great joy the glory of him who receives them, for they shall have rest in seven orders. 92 The first order, because they have striven with great effort to overcome the evil thought which was formed with them, that it might not lead them astray from life into death. 93 The second order, because they see the perplexity in which the souls of the unrighteous wander, and the punishment that awaits them. 94 The third order, they see the witness which he who formed them bears concerning them, that while they were alive they kept the law which was given them in trust. 95 The fourth order, they understand the rest which they now enjoy, being gathered into their chambers and guarded by angels in profound quiet, and the glory which awaits them in the last days. 96 The fifth order, they rejoice that they have now escaped what is corruptible, and shall inherit what is to come; and besides they see the straits and toil from which they have been delivered, and the spacious liberty which they are to receive and enjoy in immortality. 97 The sixth order, when it is shown to them how their face is to shine like the sun, and how they are to be made like the light of the stars, being incorruptible from then on. 98 The seventh order, which is greater than all that have been mentioned, because they shall rejoice with boldness, and shall be confident without confusion, and shall be glad without fear, for they hasten to behold the face of him whom they served in life and from whom they are to receive their reward when glorified. 99 This is the order of the souls of the righteous, as henceforth is announced; and the aforesaid are the ways of torment which those who would not give heed shall suffer hereafter." 100 I answered and said, "Will time therefore be given to the souls, after they have been separated from the bodies, to see what you have described to me?" 101 He said to me, "They shall have freedom for seven days, so that during these seven days they may see the things of which you have been told, and afterwards they shall be gathered in their habitations." 102 I answered and said, "If I have found favor in thy sight, show further to me, thy servant, whether on the day of judgment the righteous will be able to intercede for the unrighteous or to entreat the Most High for them, 103 fathers for sons or sons for parents, brothers for brothers, relatives for their kinsmen, or friends for those who are most dear." 104 He answered me and said, "Since you have found favor in my sight, I will show you this also. The day of judgment is decisive and displays to all the seal of truth. Just as now a father does not send his son, or a son his father, or a master his servant, or a friend his dearest friend, to be ill or sleep or eat or be healed in his stead, 105 so no one shall ever pray for another on that day, neither shall any one lay a burden on another; for then every one shall bear his own righteousness and unrighteousness." .....2 Esdras 7:75 //////////////
@sedky6924 күн бұрын
?
@ugenegareth933923 күн бұрын
@@sedky69 there's no question mark, to the kind of truth that set's one free, that wakes one up from sleep or from a dream before the house burns down
@ericbeauchamp6390Ай бұрын
Hello! thank you for this video! I was looking to see if there is a way to disable the reporting to the Central thru a landline, I have no more landline and had to disconnect it from the system, this is on a SP6000?
@sedky69Ай бұрын
Hi Eric, Yes. Absolutely you can turn off telephone line monitoring. Check the babyware or winload tutorial. You go in the "Reporting" section, remove the monitoring station number, select "Disable Reporting" and turn off "Telephone line monitoring", so 3 sections you have to deal with. I am assuming you are an installer.
@ericbeauchamp6390Ай бұрын
@sedky69 that is excellent thank you! It is exactly what I wanted to know!
@issacmoo3950Ай бұрын
hi bro how to see IP 150 light is correct no issue got link to internet?
@sedky69Ай бұрын
On older ip150 Internet light will be on if swan is enabled. You can do that by logging into the ip150 webpage. On ip150+ I believe it should come by default. You might have issues in corporate environments because internet access may be restricted
@NaeemAbdul-c9gАй бұрын
hello. where are you located in Canada? Thanks.
@andrasabraham9399Ай бұрын
Can you upload a video of a 4 wire smoke detector programming in Babyware?
@sedky69Ай бұрын
It will take me some time to have this ready, but it is really straight forward. You set your zone to Instant Fire if you want the signal to go immediately or you set it to delayed fire if you want to give the user sometime to silence the alarm. Usually about 30 seconds.
@andrasabraham9399Ай бұрын
@@sedky69 I programmed the zone as an instant fire zone. I set the fire reset to the Pgm1 output. I put the 1kOhm resistor at the end of the line. My only problem is that now this fire zone is constantly open. I can only alarm with forced arming.
@sedky69Ай бұрын
@@andrasabraham9399 What kind of smoke detector is this? If it is a low voltage smoke detector, it should go on one of the zones. You don't need to use a pgm. If it is a high voltage you use a relay.
@andrasabraham9399Ай бұрын
Cooper M12
@sedky69Ай бұрын
@@andrasabraham9399 It looks like a low voltage. You can wire the NO and COM to a zone and set that zone to be a fire zone. Use instant for testing, but when you're confident it works, set it to a delayed fire zone to give them some time to silence it in case of a false alarm.
@JamesB-b5vАй бұрын
@sedky69 thank you for the recommendations. I'll give it a try.
@JamesB-b5vАй бұрын
Thank you for the great video. Do you think if i can upgrade a very older version of Evo 192: Firmware 1.11? if yes to which version?. Thank you.
@sedky69Ай бұрын
It is a tricky question. When it comes to EVO192 I am always reluctant to upgrade them without a good reason such as the need to connect with an IP module or something like that. Even more so if you have ACMs on them because an upgrade to the panel might require an upgrade to the ACM and possibly even other accessories. Assuming it can be upgraded, you have to see what ACMs you have on them. If you have an ACM1P don't do it because you'll likely need to replace it with an ACM12
@sedky69Ай бұрын
If it is used as an alarm panel you can try to upgrade. The software will tell you if the panel is not upgradeable. As a disclaimer, check what equipment is on it to make sure those equipment will continue to work and be prepared to need replacements in a worst case scenario.
@sedky69Ай бұрын
One last note, because the version is very old the firmware will be 128k, so it will need to be upgraded to a 256k first (if it allows you), then it can be upgraded to a more recent version.
@JamesB-b5vАй бұрын
Thank you for the responses. the panel is just an alarm panel. no modules are attached to it just a k641 keypad. so no acm ip50 etc... The reason for upgrading the panel is to replace the older keypad with a more user friendly TM50 which require that the panel should have a version at least 2.16. I tried version 2.18 with infield and 307USB setial connexion but did not succeed.
@sedky69Ай бұрын
@@JamesB-b5v In this case it is fairly safe to attempt the upgrade. Keep in mind that you will need 2 upgrades as I mentioned. After you upgrade to the 256k you can go to any recent version. If you go above version 6.x you cannot go back. Once again, if something goes wrong you might have to replace the panel. It never happened to me, but you never know. I also recommend to power cycle before you attempt the upgrade and also to have a good battery connected. Don't let the laptop go in sleep mode (or run out of battery) during the upgrade.
@BryanAhJack2 ай бұрын
Hi. I have a SP6000+ Paradox panel. I would like to program the panel to a schedule arming and disarming using babyware
@sedky692 ай бұрын
@@BryanAhJack The section for auto arming is in the area section. I am not sure if they still allow auto disarming. I would have to check
@BryanAhJack2 ай бұрын
@sedky69 ok, yes thank you, i see the auto arming but yes I do not see any auto disarming
@Sylvie-GérardGleize2 ай бұрын
Great video. Thanks!
@davidhuynh68752 ай бұрын
Hi Wael. Thank you for your videos! I’m needing some help on the following: I’ve installed an evo + acm12 for 1 door access for a laundromat. Using a LOX mag lock. My customer wanted a schedule set for the door to auto lock/unlock. Unlocked from 7am-11pm during business hours. Problem I’m having is the mag lock will lock at 11pm but won’t unlock itself at 7am so they physically need to go to their store to tap the fob every morning. The Door PGM button on the app only allows for push exit and will go back into locking state right after Is there a way around this? Basically need the door to unlock itself at 7am qnd remain unlocked as per schedule Kind regards, David
@sedky692 ай бұрын
Hi David, try unchecking “Card/pin activates unlock schedule”. I believe the schedule will kick without the first swipe. Let me know how it goes.
@hristobarbolov59532 ай бұрын
Although it's outdated, I still personally use WinLoad
@sedky692 ай бұрын
It is still relevant especially if you are using old panels. Also when I was getting into alarms I liked it because of the section numbers. It was easy to find what you are looking for.
@damianbarr2 ай бұрын
Thanks so much for this great little video. The beeping every time I waked into our living room was driving me nuts! This solved it perfectly, very helpful 😊
@ibbbraa3 ай бұрын
I'm getting initiating panel connection Time out and authentication failed wrong panel ID error. What am i doing wrong?
@sedky693 ай бұрын
I need more information about your connection. Did you install the drivers for the USB adapter? It sounds like you didn’t choose the correct type of connection. Check my babyware tutorial
@DigitalHugoTv4 ай бұрын
Un abrazo viejo
@OvideluBlondu4 ай бұрын
Thx , u saved me 🎉🎉🎉
@ceco9415 ай бұрын
Greate video, i jus have one question : is there is a way to mute the counting beeps during arming ?
@sedky695 ай бұрын
Thanks. By pressing the clear button until it beeps in about 6 seconds. That will mute the keypad so it will only beep for 10 seconds and stop. Be careful though; an undesirable side effect is that when the system is armed and you enter the house you will not hear the beep that reminds you to disarm.
@ceco9414 ай бұрын
@@sedky69 Thank you so much ! i will try it . i just forgot to tell you that my keypad is K32LCD is this will work on this model ? Thank you !
@sedky694 ай бұрын
@@ceco941 Pressing Clear for 6 seconds will enable/disable the mute function. If clear doesn't work and your keypad has musical note sign printed on the down arrow, you can try that instead of clear. Let me know.
@lombardjohann47335 ай бұрын
Unfortunately the conection to babyware through ip180 module doesn’t working, no matter what i do i tried all passwords like paradox for IP module, and 0000 for panel ,I have access to ip module over internal network, seems they changed something it works only external over cloud
@sedky695 ай бұрын
What is your panel?
@arkop-p6 ай бұрын
Does the addition of ip150+ devices to the EVO 192 PBX force a new PBX configuration. Currently I only have sms and tel notification.
@sedky696 ай бұрын
If I understand you correctly, the ip module and phone line monitoring are completely separate and can be independently configured. In fact some of our customers are monitored by both. I don’t have experience with sms but I imagine it is separate as well because I remember seeing a separate section for sms in babyware
@arkop-p6 ай бұрын
@@sedky69 It works both ways, I've managed to connect and set up the Blueeye app only now I have 7 days free and I can't find how much it costs and how it's worthwhile
@pacovccici6 ай бұрын
Thank you for this great video. I recently got sp7000, but when I wired and added the k10v it says the module is offline.
@sedky696 ай бұрын
@@pacovccici double check the wiring is good and May be try the keypad at the panel to eliminate any wire damage. Finally you can try doing a module scan. Section 955
@gavicon7 ай бұрын
What is the factory password to configure other NEware or HTTP port?
@sedky696 ай бұрын
The default password if it is not connected to a panel is 1234, but to connect to a panel you need to use the master code of the panel
@chuj92887 ай бұрын
when i am trying to connect to babyware with the mg6250 it requires panel id/ pc password where can i found the panel id of mg6250
@sedky697 ай бұрын
Have you tried to login to the panel from the keypad and finding that out? This one seems different. I am not familiar with it, but the default username and password is admin for both
@chuj92887 ай бұрын
@@sedky69 I have tried everything, even to section programming with 3011 and 3012 also with 910 and 911. I cannot find the panel id and pc password and when I try to connect with babyware it will not connect
@sedky697 ай бұрын
@@chuj9288 From what I see this is a different type of panel. It seems you have to scroll through the menu. Check page 28 of the manual steps 7 and 8. If not you will have to contact your dealer. I am not affiliated with Paradox.
@yavorhristozov33738 ай бұрын
thank you!
@ArchuthanAmbigapathy8 ай бұрын
Really great post. Can you post a video "How to program the key fobs" using EVO192 and ACM12. Thank you.
@sedky697 ай бұрын
Did you watch the whole video?
@KhalidSulaiman-fx5bk8 ай бұрын
Great Video. Can you please help me to trigger the alarm if a zone/door is opened for more than 5 seconds? I created a Zone to act as a Panic and connected a 3rd party receiver and remote to activate it. I only want to trigger the Alarm if I hold the button down for 5 seconds.
@sedky698 ай бұрын
Let me get back to you on this
@heroharo8 ай бұрын
Thank you for video, is there a way to get Installer code, if i have only master code? Thank you
@sedky698 ай бұрын
You can get it if you have the babyware software, but you need the panel ID and password. I assume you are an end user?
@heroharo8 ай бұрын
@@sedky69 yes i am, i have babyware, but login fails as i dont have pc password as well
@sedky698 ай бұрын
@@heroharo unfortunately you need to have one of those two pieces of information. Either the installer code or the panel ID and password. The whole point of these is to prevent others from taking over your panel. If the panel is not locked you can factory reset it. To find out if it is locked, power cycle it. If it is locked you will hear the relay clicking. If it is not locked it will just startup.
@sedky698 ай бұрын
Of course if you power cycle it you will get timer loss trouble and you will need to adjust the clock. Also keep in mind if you factory reset the panel (assuming it is not locked) you will wipeout all the programming
@sedky698 ай бұрын
unfortunately you may have to replace the panel
@MrAmanpreet338 ай бұрын
Can you please make a video on programming pgm outputs from paradox keypad
@Frank-yz6ih9 ай бұрын
Thank you very much ,with your Help IT was possible do do it
@AngelMichael68510 ай бұрын
Έβαλες μαγνητική και ραντάρ στο συναγερμό
@sedky6910 ай бұрын
All door contacts
@AngelMichael6859 ай бұрын
@@sedky69 τις βλέπω. Πόσα χρόνια κανεις τοποθέτηση paradox
@AngelMichael6859 ай бұрын
@@sedky69 μόνο paradox βαζει;ς είναι γρήγορα μηχανάκια στο κέντρο..
@AngelMichael6859 ай бұрын
@@sedky69paradox Καναδά
@AngelMichael6859 ай бұрын
@@sedky69 τον πινακα να τον κλειδώνεις με κωδικό και από το υπολογιστή με κωδικό . Εγώ 15 χρόνια έβαζα paradox
@gabortoth337410 ай бұрын
Hello. How do you setup that the keyboard panel shortly beeps 3 times whenever you open the front door? My one does this but I cannot find it in Babyware. Thank you.
@sedky6910 ай бұрын
Check my video muting/unmuting a zone
@gabortoth337410 ай бұрын
Thank you. Your videos are really helpfull!
@gabortoth337410 ай бұрын
can you protect the panel with a door sensor in the box without assigning a zone to it?
@sedky6910 ай бұрын
I don’t know. I would use a zone if it is needed.
@gabortoth337410 ай бұрын
Many thanks for the video. Unfortunately K32IRF does not have single key background. I would share a video with you what I can see on my K32IRF. Do you have an email address for that?
@sedky6910 ай бұрын
I am not sure what you mean by "does not have single key background". I checked my instructions with a K32 and it worked. K32 doesn't have a 0. The 10 lights up instead. You can post an unlisted video and put the link in the reply.
@gabortoth337410 ай бұрын
Thans fo the hint, it works. Is there a way tu update IP150 without a panel connected just give it power? Where can i find downloadable firmwares for it?
@gabortoth337410 ай бұрын
@@sedky69 Thans fo the hint, it works. Is there a way tu upgrade the IP150 without a panel connected just give it power? I bought an IP150 firmvare v4.1 and I can login to the webUI of it, but I cannot connect to the panel through the IP150. So either the IP150 is wrong or the serial port is disabled for the SP6000?
@sedky6910 ай бұрын
@@gabortoth3374 I have never tried that. Try connecting using the static ip. Make sure the ip module is connected to the serial port of the panel. The one on the top right of an sp6000. There are two ports that are similar and it is easy to confuse them if you are not familiar with the panel
@gabortoth337410 ай бұрын
@@sedky69 I connected to the right port (the other one has five pins). I am clueless what might be the problem. Is there a setting of the panel to enable / disable the serial port of it?
@Frank-yz6ih10 ай бұрын
Hello can you please Help me. On the evo192. The newest Software ist Always askimg me to Change the Default Panel ID and Password But dont Accept any number or Letters , before i changed the Login. What ist my mistake?
@sedky6910 ай бұрын
You can download an older version of babyware. Older versions don't force you to change the password, but the password should not be left at the default. You can also try to change the id and password using the keypad. For evo it is sections 3011 and 3012.
@sedky6910 ай бұрын
For troubleshooting, disconnect from babyware and see if you are able to login to programming from the keypad
@gabortoth337410 ай бұрын
hello. Thanks for the video. What is the exact sequence to retrive the panel ID and PC passoword using MG32I?
@sedky6910 ай бұрын
Hi. I am not sure what the MG32I is. I don't see it on the paradox site, but generally panel id and password are sections 910 and 911 respectively. From the start, press Enter, press installer code, press 910, the numbers are going to light up according to the panel id. You press the same number as they light up to move to the next number. Once you reach the end of section 910, it automatically goes to section 911. Follow the same process.
@gabortoth337410 ай бұрын
@@sedky69 My mistake, i have K32IRF keypad. And after entering 910 one of the zone incitacor is shown olny (10). Should I prees 1 and 0 to move to the next part of the panel ID? (I am asking because it is weird that I did not get single digit prompt. The panel is SP6000. Thanks for the further hints
@sedky6910 ай бұрын
@@gabortoth3374 Watch my next video and let me know if it helps. It should be ready in 30 mins or so.
@mariancristofovici750611 ай бұрын
Thank you very much for the valuable information that you provided to us.
@sedky6911 ай бұрын
Thank you.
@michapapa882 Жыл бұрын
Thank you very much for this video!
@sedky69 Жыл бұрын
Glad it was helpful!
@rosslynnchris-lloyd2329 Жыл бұрын
Speak properly man...cant understand a damn thing
@talijay5823 Жыл бұрын
How you review this watch is boring
@sedky69 Жыл бұрын
You don’t have to watch it if you don’t like it
@dunblaneuk Жыл бұрын
THANK YOU FROM AUSTRALIA
@markd3096 Жыл бұрын
Hi Wael, I wonder if you can help me. I have a K10H keypad. It has a mute for the Auditory feedback. How can I increase the volume of the feedback? Thank you
@sedky69 Жыл бұрын
Hi Mark, I am not aware that you can increase the volume. As far as I know it is either on or off. Hold down the clear button until it beeps to mute or unmute. For the zone numbers you hold down the zone number
@costelflueraru2442 Жыл бұрын
Hi I am looking forward to the the training video about the zone setting. 1. I am not sure how to set the access code (to arm/disarm) for a simple house security setting using Babyware. I know how to do it using the keypad. In Babyware there is a large number of users... while in a house setting I was using one code for arm/disarm. 2. I am dealings with a situation in which Babyware reports no trouble while the keypad shows trouble (no wireless bell!?). I do have few wireless windows contacts in the system (SP with an RTX3) but I never used or set a wireless bell. Not sure where is coming from.. Many thanks,
@sedky69 Жыл бұрын
What is the trouble code?
@costelflueraru2442 Жыл бұрын
The key pad flags a trouble. When checking it show missing module: wireless siren. I have never install or use a wireless bell. Not sure how it was added to my system. most likely is a default setting. However when open up Babyware there is no trouble list. Any suggestion is highly appreciated. thanks
@sedky69 Жыл бұрын
@costelflueraru2442 Have you tried a module scan? Section 955 for the SP and MG series. Tell me which panel you are using and which lights come up when you press TBL. Also once this light comes up, press it and tell me what lights (digits) come up next.
@costelflueraru2442 Жыл бұрын
The system is SP7000+, K32LCD, K10V/H and RTX3 with 5 wireless contacts. On the keypad (K32LCD) is shows Trouble Press TBL. I press TBL then keypad shows: Missing Module{arrow up} [0] to View {arrow down}. Press 0 then keypad shows Missing module{arrow up}, Wireless Siren {arrow down}. Pressing arrow up again it cycles: Missing module{arrow up}, Wireless Siren{arrow down} when press again changes to Missing Module {arrow up}, No trouble {arrow down} continuing to press the arrow will cycle between this two messages. No other knob/digit is lighting up! It is annoying! Babyware shows no trouble!
@sedky69 Жыл бұрын
@@costelflueraru2442 I have a couple of suggestions, but I have never dealt with this panel or a wireless siren before. Check sections 587 options 3 to 6. Set them to off. Also sections 683 to 686, make sure there are no serial numbers there for the wireless siren. sections 691 to 694 same. Section 695 press enter. Once confirmed there is actually nothing programmed for a wireless siren do a module scan section 955. It will clear any trouble related to a non existing module. You can try section 955 before you do all this actually. Let me know what happens. If not there is always the possibility that the panel is defective.
@costelflueraru2442 Жыл бұрын
Sorry in my previous message I was referring to input speed not zone speed. so what is input speed and how to use it? thanks
@sedky69 Жыл бұрын
I never experimented with that, but here is what I see from the manual: "The Input Speed defines how quickly the control panel responds to an open zone detected on any hardwired input terminal (does not apply to addressable motion detectors and door contacts)." I could see this being used with zones that are falsing too often, but I haven't tried it yet, so try it out in a controlled environment before you use it in the field.
@costelflueraru2442 Жыл бұрын
Hi there, Very nice and informative. Thank you! You said you will do a training on the zone definition. Did you? What is zone speed? and how to use it? I have many more questions. Thanks
@sedky69 Жыл бұрын
I haven't done any new trainings yet. I hope to do in the new year.
@higchannel10 ай бұрын
Regarding Input speed, you can adjust it to increase or decrease the signal response time in that zone. eg: default 60 input speed allows the sensor to respond immediately however you can adjust it to increase response time to 2.3 or 4 seconds
@nathanruben3372 Жыл бұрын
Very helpful. Thanks.
@nathanruben3372 Жыл бұрын
During firmware update, ip150 bricked itself. What can I do? I can not access it.
@sedky69 Жыл бұрын
The latest firmware updates don’t have a web interface like before. Also don’t assume it is bricked. Just leave it connected for a while and let it do its thing. Forget about it for an hour or so
@Kickback007 Жыл бұрын
Appreciate you Wael 🙌🏽
@ZAMCO1996 Жыл бұрын
Low voice
@sedky69 Жыл бұрын
Thanks for your comment. I checked the video on my phone and the sound volume is fine. There is not much I can do, but I’ll keep this in mind for the future
@ZAMCO1996 Жыл бұрын
Low sound
@good2know513 Жыл бұрын
Thanks for video, could you please tell me if I have 2 K636 keyboards, how should I define them?
@sedky69 Жыл бұрын
I am not familiar with that one, but based on the manual it is compatible with SP and MG series, so I assume it is the same as the K10H. Just a different look. I mean there is nothing to program for a keypad. If it doesn't work it may be a very old model for the Esprit line up.
@DanielsGameVault Жыл бұрын
Can you still access the IP150 from a web browser after firmware version 4.0 ? I just bought an IP150+ (PLUS) and the web interface refuses to load. "IP Exploring Tools" detects the module but I can't change any settings, not even the IP address from DHCP to static - it asks for the password, it SEEMS to work, but in reality nothing gets applied. The HTTP port is zero by default, so the browser refuses to connect to it...
@sedky69 Жыл бұрын
4.0 is a buggy firmware. Try to upgrade to 4.2 or above. Actually once you try to upgrade it will automatically take you to 5.2. You should be able to access the web interface after.
@DanielsGameVault Жыл бұрын
I just discovered the IP150 PLUS dropped the web browser interface - the HTTP port number shows up as zero and the browser refuses to connect.....I wonder if the IP150 (blank) also suffered from this as a result of a firmware upgrade, so I may return the IP150+ and try sourcing an IP150 instead....
@sedky69 Жыл бұрын
Do you know which firmware version you have there? At one point I had this issue, but with later versions I am able to login to the web interface
@DanielsGameVault Жыл бұрын
@@sedky69 It's V5.06.014 the latest on the Paradox website (and I believe it upgrades automatically). It could be the model itself dropped the web support (like I said - I have the PLUS model), so I was curious if you still have access to a standard IP150 (base model, no PLUS) to confirm it still has the web interface even with the latest firmware, which for the base model (no PLUS) should be V5.02.058 according to Paradox. Really curious if they dropped the web support on both models via firmware or just on the PLUS model.
@sedky69 Жыл бұрын
I will have to find out and get back to you. Why do you need to access it? Is it for the network settings or something else?
@DanielsGameVault Жыл бұрын
@@sedky69 Please do. Yes, mostly for the convenience of setting it up. I feel like I've been ripped off. I worked with the IP150 before and I could quickly set them up from the web interface. Now I have to download a dedicated app on my phone, plus have to use an installer account ! Can't even do it myself as a regular user...definitely NOT OK on Paradox's side....
@sedky69 Жыл бұрын
I checked one of the ip modules I have; it was actually a regular IP150 that has been upgraded to the firmware you mentioned; It looks like they have disabled the web interface. Even the https is disabled. You might be able to assign it a static ip using the tool (I haven't personally tried that), but worst case you can do it on the router level. The functionality you really lose is email notifications. Hopefully it is just a bug that will be fixed in the future.