Bang mau nanya.. untuk motor induksi 3 fasa, andaikan tidak ada konekan grounding apa bisa juga menimbulkan panas/ asap? Trima kasih
@Hendraditya9 сағат бұрын
@@NurFauzan-y4n Seharusnya tidak, bila masih dlm kondisi seimbang.
@KyriakosAgapaloglou23 сағат бұрын
Excellent idea !! However in order to build it from scratch, is it possible to have the dimension of the PCB as well as the schematic diagram ? Thank you in advance for your effort
@Hendraditya14 сағат бұрын
To make it from scratch, start by determining the component layout, then connecting it, so that it becomes a PCB. And make it as dense as possible to get the smallest possible PCB area. The new diagram scheme is made after the project is running properly.
@Kmng-q8f2 күн бұрын
Terimakasih mas apa ada buku nya mas bisa buat belajar
@jualonline26956 күн бұрын
Ada video bikin sepeda listrik bisa maju dan mundur ngga om?
@Hendraditya6 күн бұрын
Videonya sih belum ada. Tp caranya ada 2, yaitu setting controller dan membalik kabel.
@jualonline26956 күн бұрын
@Hendraditya ok om mksh infonya
@jualonline26956 күн бұрын
Sangat membantu
@Elone-k5c7 күн бұрын
Ini baru bener
@asantoso749 күн бұрын
Mau tanya bang, kapasitor untuk koreksi apa bisa kita pasang untuk tiap alat sendiri? Kalo dipasang kapasitor per alat Apa pengaruhnya ke keseluruhan kelistrikan di rumah?
@JuwitaTrianggraini-n1i10 күн бұрын
Bg slot 48 , rpm 420. Gambarin bg
@dobler689315 күн бұрын
bisakah untuk dinamo yg dta kwat dan jmlah tidak ada..sambungan delta
bikinkan tutorialnya bang..untuk dinamo 3 fasa yng ngak ada namplet atau tanpa diketaui data kawat..jmlah.
@roadstory898317 күн бұрын
QS motor ya pak?
@papahbilal960520 күн бұрын
Om bikin video pcb controllernya dong, saya pengen solder kabel gas sama kontak putus dari dalam pcb nya. Soalnya gak tau titik soldernya yang mana
@BalyanRasid21 күн бұрын
Maksud saya bagaimana kita tahu panjang kawat isi gulungan tersebut
@Hendraditya21 күн бұрын
@@BalyanRasid Panjang = Jumlah gulungan x keliling gulungan.
@husenpratama-fy3pc23 күн бұрын
Itu 3,14 dari mana
@Hendraditya22 күн бұрын
@@husenpratama-fy3pc rumus lingkaran
@MulyotoYoto-dt5zcАй бұрын
Namanya apa alatnya itu bang
@HendradityaАй бұрын
@@MulyotoYoto-dt5zc BLDC tester
@muhammadirfanjambak4331Ай бұрын
Izin om, watt tidak sama dengan VA untuk sinusoidal (AC). Watt = VA jika pada DC. Sedangkan energi itu satuannya watthour. Jadi perbaikan faktor daya tidak mengurangi energi yg digunakan oleh beban (pompa). Keuntungan kita dalm perbaikan faktor daya adalah dapat memaksimalkan penggunaan arus yg di berikan penyedia (PLN)
@HendradityaАй бұрын
@@muhammadirfanjambak4331 Simak penjelasannya di deskripsi
@HendradityaАй бұрын
@@muhammadirfanjambak4331 VA adalah satuan daya untuk penyuplai listrik. Sedangkan Watt adalah satuan untuk penggunaan daya (daya consume). AC maupun DC menggunakan kedua satuan tersebut.
@HendradityaАй бұрын
@@muhammadirfanjambak4331 Untuk trafo & generator, menggunakan satuan VA. Karena menghasilkan daya. Sedangkan motor & speaker (DC), menggunakan satuan Watt. Karena menggunakan daya.
@samianmian7749Ай бұрын
Apa bisa kita pasang langsung satu kapasitor di dekat meteran
@donniumar767Ай бұрын
MENENTUKAN AMPERE DARIMANA
@lekthomson40716 күн бұрын
Diameter kawat menentukan besar kecilnya arus
@sedangmengetik.....9297Ай бұрын
4 itu hitungan dpt dari mna
@HendradityaАй бұрын
@@sedangmengetik.....9297 Menentukan current density itu bebas sesuai kemampuan lapisan kawatnya. Klo saya pakai range 4 - 6 A/mm2.. Makin tinggi rapat arusnya, maka makin panas trafo/motor yg kita bikin. Makin kecil rapat arusnya, makin mahal ongkos beli tembaganya, karena otomatis ukuran kawatnya makin besar. Bisa juga lihat referensi dari Google mengenai "Current Density".
@SuryaSaputra-d3hАй бұрын
Mau tanya bang kalo yang A itu pake primen nya kira kira abis brapa kilo kawat emailnya dan untuk sekundernya kira kira dapet berapa kilo kalo bisa tolong di kasih rumus cara ngitung kebutuhan kawatnya berapa kilonya
@HendradityaАй бұрын
@@SuryaSaputra-d3h Seinget saya udah ada di video yg lain bang
@supian7182Ай бұрын
ora mudeng mas. mendingan beli jadi aja.
@herdiyantoherdiyanto40422 ай бұрын
Penjelasan yg sangat berguna bagi pemula..terima kasih atas share ilmunya🤝
@Tanahterjajahbanten2 ай бұрын
Sangat membantu
@sultanachmad87992 ай бұрын
Tahan air gak sih?
@adityasurya35072 ай бұрын
bang izin nanya, saya hanya ingin jika tandon air penuh maka sanyo mati otomatis itu saja sih, karna saya takut sanyo saya bermasalah tidak mau naik airnya, maka dri itu adakah rangkaian dan komponen apa saja yang bisa saya beli?
@Hendraditya2 ай бұрын
Cuman butuh sensor air, relay 220V, sama power supply.
@nioelectronic2 ай бұрын
Terimakasih Ilmunya Mas Bro
@AgusSalim-fc2hv2 ай бұрын
Udh pernah gulung dinamo mas
@Hendraditya2 ай бұрын
Sudah sering mas. Untuk produksi masal di 2 perusahaan. Yg satu otomotif, yg satunya pompa air merk tertentu.
@AgusSalim-fc2hv2 ай бұрын
@@Hendraditya mana lebih hebat tukang lapangan tw ahli kuliah
@Hendraditya2 ай бұрын
@@AgusSalim-fc2hv Tidak bisa dibandingkan bang. Semua ada kelebihan dan kelemahan masing-masing.
@AgusSalim-fc2hv2 ай бұрын
Speed 120 mas dpt dri mana
@Hendraditya2 ай бұрын
Rumus dasarnya adalah frequensi dibagi pole pair (Freq : pole pair). Dengan satuan detik (rps). Pole pair adalah jumlah pasang kutup. Misalkan ada 1 pole pair, maka pole nya adalah 2, yaitu utara dan selatan. Karena kita ingin satuannya RPM, maka harus dikali 60. Sehingga rumusnya menjadi 2 x 60 x Freq : pole.
@AgusSalim-fc2hv2 ай бұрын
Mas dlu kuliah nya dmn kalau boleh sy tw
@rafarizky71842 ай бұрын
Untuk votol em 100 dengan blcd inner rotor juga bisa om?
@marimpd88822 ай бұрын
Handle rem
@marimpd88822 ай бұрын
Yang belum pemasangan rem?
@KhoirulAnam-f1z3 ай бұрын
yg di colok an ke batrai itu apa bng? Casan atau apa?
@ifan73 ай бұрын
Assalamualaikum Pak maw nanya apa penyebab pump hidrolik stering gear kapal , pump hidroliknya baru diganti hanya cepat panas Apa penyebabnya ya Pak Terimakasih
@BorUp-f8w3 ай бұрын
Apakah ada skemanya ?
@bayudelisa58523 ай бұрын
Kak kalo untuk air tinggal dikit .. Bisa bunyi alarrm bunyi keras gimna
@Hendraditya3 ай бұрын
Bisa ditambahkan modul alarm di output relaynya.
@natsukifukawa3 ай бұрын
next rumus rewinding motor induksi 3 fasa, pak
@Hendraditya3 ай бұрын
@@natsukifukawa Sudah ada kok bang..
@natsukifukawa3 ай бұрын
@@Hendradityaapakah ada video praktik nya?
@satrijow3 ай бұрын
Current density itu darimana ya?
@ikhsanulfuad39823 ай бұрын
Klo berat kern 20kilo dan mau dibuat tegangan 65 -65 ct 130-130. Untuk ukuran kawat primer dan sekunder yg tepat ukuran brp bang ...
@rahmadhidayat62944 ай бұрын
Kalou tegangan 5 volt nya yg nggak muncul gibmana bang solusinya
@muhammadmiftakhuddin85404 ай бұрын
mantap
@manuelospina64594 ай бұрын
Ini yg selama ini dicari, Praktis tinggal masukin, daripada trial error sendiri banyak email yg kebuang. Makasih atas sharing ilmunya.
@KangdinKdm4 ай бұрын
Matur suwun...mantappp
@manwaranwar27894 ай бұрын
mantap mas... ilmu y sngat berguna.. lanjut kan mas...
@eliselis37404 ай бұрын
Dengan motor listrik sama gk bos
@Hendraditya4 ай бұрын
@@eliselis3740 Ini adalah motor listrik
@eliselis37404 ай бұрын
Sepeda listriknya
@Hendraditya4 ай бұрын
Iya, bisa dipakai di sepeda listrik
@eliselis37404 ай бұрын
48v bsa modip ke 24v bidamo kah bos
@Hendraditya4 ай бұрын
@@eliselis3740 Bisa
@asriwulandari7254 ай бұрын
untuk perhitungan ini berlaku untuk jenis alur lap winding?
@Hendraditya4 ай бұрын
@@asriwulandari725 Lap dan wave winding
@prisnrev52654 ай бұрын
Music nya unik,, harap sertakan sumber
@bambangsetiyo58994 ай бұрын
Tq tutorialnya Penjelasannya sangat jelas dan detail... Mau tanya utk power faktor fogital sebaiknya merk apa ya? Yg pasti terkalibrasi bagus gt....
@Hendraditya4 ай бұрын
Saya kurang tau bang..
@adeaniteknik6954 ай бұрын
Mantappppp
@MeldaManuturM5 ай бұрын
Klo utk tangki fiber 2000 liter bisa gak ya??? Karna sering kelupaan matikan mesin ktka air sdh penuh... Jd lantai 2 suka banjir