@lbmitchell1777
@lbmitchell1777 Ай бұрын
I just found out that my maintenance guy put the inlet air filter in backward. Could this be the cause for my freeze-up?
@deacadeind
@deacadeind Ай бұрын
My Sante Fe advance 90 is producing water but at a lot less rate. Now, the humidity in my encapsulated crawl is at 71% used to be at 38%
@VincentVazzo
@VincentVazzo Ай бұрын
Why is the 120V so significantly more expensive than the 120?
@jcmoor1
@jcmoor1 Ай бұрын
Nope , that means your unit is corroding and time to replace .My advance 90 just did this and I am replacing with the Oasis 105, which has a positive pressure drain system and will hopefully last longer 😢.
@davidfettig8885
@davidfettig8885 2 ай бұрын
Why don’t you have to put a P trap like the other videos?
@LogansRun314
@LogansRun314 9 ай бұрын
Great, thanks for this!
@kiltedpiper98
@kiltedpiper98 10 ай бұрын
Thank you. Very helpful.
@duke8389
@duke8389 11 ай бұрын
Is it normal to have some water leakage on the bottom right side (filter side) of the Santa Fe Advance 90??
@ioda006
@ioda006 11 ай бұрын
Can UV light be installed in these units to prevent mold?
@mikebarrett8572
@mikebarrett8572 Жыл бұрын
What about the black box the water goes in?
@vladm9096
@vladm9096 Жыл бұрын
I always wondered why negative pressure doesn't suck water before trap gets filled? I understand trap is helpful in order not to suck dusty air, but concept about pulling water backwards is not clear. Water still goes downward to fill trap, right? Then why not to let water go further via high pitch tube to the drain or pump.Traps are known to accumulate dirt, so why not to get rid of them to avoid often cleaning them and water overflow.
@burrmanchu687
@burrmanchu687 9 ай бұрын
You prime the trap so the water goes down. If you don't have the trap primed, some of the water going down will be pulled back into the unit.
@vladm9096
@vladm9096 9 ай бұрын
@@burrmanchu687 No, it is not how it happens. I installed hundred ACs for over 30 yeas. Never primed/filled the trap. When AC start working it fills the trap and then water starts to go down the drain. During fall/winter/spring time trap completely dries out. Yet nobody goes to let say attic AC to prime trap. All happens by itself.
@AlloyedFrequencies
@AlloyedFrequencies Жыл бұрын
Makes a lot of sense, thank you
@Anton-du-Fleur
@Anton-du-Fleur Жыл бұрын
That trap is so potential to issue and the instruction is very poor. If installer do it like this , there is a disaster waiting to happen . Ask me for a proper trap set up I would be happy to advise
@Anton-du-Fleur
@Anton-du-Fleur Жыл бұрын
why isnt there insulation on the rest of the duct.? Potential condensation issue already pointed out..
@Interesting_Placebo
@Interesting_Placebo Жыл бұрын
Would this be done the same way if using an external condensate pump to move the water outside of a crawl space?
@meyou-dv8ns
@meyou-dv8ns Жыл бұрын
you put it on NORMAL. ?
@jwwitz
@jwwitz Жыл бұрын
I just purchase an Oasis 105 and want to add a float switch as well as an intermittent Alarm if the unit throws an error code. I have a float switch ordered and understand how it get wired to the control but I need help on wiring an Alarm. The only alarms Ive found are 24 VDC. Can a DC alarm be used and which terminals are to be used.
@confidentlocal8600
@confidentlocal8600 Жыл бұрын
These units short cycle when the fan is set to AUTO because the humidity control is in the base, near where the condensate sits. They really need a remote humidity control provision.
@MadSocial
@MadSocial Жыл бұрын
Mine is set to normal but there is water drops all over under the water barrier. I don't think normal setting is working in MD in Dec. I put it to drier...but idk guys ..need some recommendations here please
@JamesStewartLittle
@JamesStewartLittle Жыл бұрын
What setting do you recommend for winter months? Do you think it is advisable to set it to “off”? Will freezing weather (below 32F) cause damage to the unit if it is running at automatic?
@jimihendrix1575
@jimihendrix1575 Жыл бұрын
Buy a dedicated microphone.
@cobertos_6455
@cobertos_6455 Жыл бұрын
Huh, maybe this is why my dehumifier has a trap on it. Was so curious. Thanks!
@lilenr3499
@lilenr3499 Жыл бұрын
why does it have to be looped? Why not just let it hang lower than the outlet port?
@SantaFePest
@SantaFePest Жыл бұрын
Great question. The dehumidifier needs a draintrap due to where the fan is located in the unit. The draintrap helps ensure the water is not pulled back into the unit. We recently launched a new dehumidifier called the Santa Fe Oasis105 that does not require a draintrap. Here is a link to the video of the new unit - kzbin.info/www/bejne/mJqYc56apbStb6s
@stevenmalpass2493
@stevenmalpass2493 2 жыл бұрын
Why not use an Aprilaire?
@SantaFePest
@SantaFePest 2 жыл бұрын
Great question, Steven. A couple of reasons - almost all of our dehumidifiers remove more water per kWh, we provide MERV 13 filters as standard with our dehumidifiers, and we offer an industry-leading 6-year warranty.
@rksg2003
@rksg2003 Жыл бұрын
@@SantaFePest How would that warranty work if say I purchased a sate fe and it quit working 3 years from? How is the warranty handled? Am I going to hav to ship this thing back somewhere or will a tech come and check it out? Thanks
@scind2585
@scind2585 2 жыл бұрын
👎 Why didn't you show how to connect the pump safety switch that will shut down the dehumidifier when the pump stops woking and the reservoir fills up?
@jonhickman1620
@jonhickman1620 2 жыл бұрын
I have 2" foam boards up the wall and spray foamed above that and the vents have been spray foamed also so my crawl space is completely sealed, now on the ground I have number 8 stone on top of vaper barrier plastic and I have the Santa fa compact 70. Just wondering if I'm all right with that.
@marciahestand1396
@marciahestand1396 2 жыл бұрын
Have a Hisense DH3019K1W 22-Pint 1-Speed Dehumidifier. Since fall dropped and humidity stays at 40s the clean filter light comes on. Filter is clean.
@petergriffin1546
@petergriffin1546 2 жыл бұрын
crawl space dehumidifier need external controls. Please send us a video on this model and installing external controls.
@pf5658
@pf5658 2 жыл бұрын
How quiet are these units compared to, say a window air conditioner?
@debbiescott9507
@debbiescott9507 2 жыл бұрын
Good video, I will not run my deh this winter, this will save me money on my electric bill
@davidcoomber4050
@davidcoomber4050 2 жыл бұрын
That’s the point, if you don’t have ventilation and the outside temperature is colder than the inside temperature leading to condensation it is more important to dehumidify in the winter than summer
@AlloyedFrequencies
@AlloyedFrequencies Жыл бұрын
Where is the moisture coming from
@michaelkiese7794
@michaelkiese7794 9 ай бұрын
Warmer air is more capable of holding moisture than cold air. Therefore in the winter, the outside air is dryer than air in the home. The moisture inside the house comes from human activities such as cooking, cleaning, bathing, breathing. Other sources of indoor moisture are potted plants and fish tanks. So like david coomber mentioned, if you don’t have ventilation, you might have high household humidity in the winter. It all depends on all these factors, and is a case by case basis.
@goturminute
@goturminute 2 жыл бұрын
Also, get some guard rails around that attic hatch!
@goturminute
@goturminute 2 жыл бұрын
Tremendous talk. I work in QC/Safety for a large commercial interiors contractor and noone is talking about humidity. I recently had to repair all the seams in a VERY large project due to the GC firing up the HVAC and letting it blast as hard as it could until desired temps were reached. This led to huge drops in % of humidity which ultimately led to starved mud joints, cracking, and accessory detachment with regards to drywall installation. I had installed hygrometers prior to the issues presenting themselves which allowed me to make the case that it was not faulty drywall or faulty workmanship. We ended up going from a potential 200k loss to a $280k profit simply because we had environmental data.
@MegaMuffinManX
@MegaMuffinManX 2 жыл бұрын
This is exactly what I was looking for! Thanks for the tip!
@sommasculpture
@sommasculpture 3 жыл бұрын
RH needs to be 30-40 not 50
@coreypatterson1386
@coreypatterson1386 3 жыл бұрын
Why is a pretzel knot needed?
@andersm2563
@andersm2563 2 жыл бұрын
Its Pretzel, Loop, or a store bought P trap. They all serve the same function.
@coreypatterson1386
@coreypatterson1386 3 жыл бұрын
Why is a pretzel not needed
@nathan4233
@nathan4233 4 жыл бұрын
I dont know how the loop works on this, but on an ac its just a bad idea, usually they end up holding water and not because they are clogged but because the fan and the sheer amount of water coming down at a given time just randomly keeps it from flowing, I would say stick with the pvc trap
@theDeitz
@theDeitz 5 жыл бұрын
Does the unit have an air filter ?
@SantaFePest
@SantaFePest 4 жыл бұрын
This unit features a MERV-13 air filter.
@theDeitz
@theDeitz 4 жыл бұрын
@@SantaFePest Thanks, one more question now that I have your Advance 2. .... I ready to install my unit under our house. To do this I need to turn it on its side. I know after it's in the upright position not to turned it on until the oil settled in the compressor, I will wait a min of 30 min. My question, being the compressor shipping ties were removed by others, if I turn it on it side very carefully will any thing come loose or break? Thanks in advance.
@philsipad
@philsipad Жыл бұрын
​@@SantaFePest No no no no no. The filter required for this unit as stated by the company is total confusion. The filter as stated in the Advanced2 manual is a MERV-8, which is P/N 4031062, size 14x17x2. The old filter from my Advance2 is P/N 4031062, but the size is 14x17.5x1.75. The MERV-13 filter is indeed 14x17.5x1.75, but has a different P/N 4037722. This company can't even get their filter inventory straight.
@kappatv6022
@kappatv6022 5 жыл бұрын
*I like the dehumidifier, low noise>>>**nub.best/3dzs** It would have been nice to have current temp reading which I had on another brand. Otherwise the unit works fine. in 3 days I emptied out two buckets of water.*
@robertcarreiro3151
@robertcarreiro3151 5 жыл бұрын
Is this unit quite?
@Allbbrz
@Allbbrz 6 жыл бұрын
I'd like to add that I am really impressed with this device but I have two observations 1) the manual should really emphasize the need to have it perfectly horizontal/level (or at most, slightly tilted forward, toward the drain port); and 2) the discharge hose length is a joke: to use it on my crawlspace, I had to run to Lowes and buy a 25-ft hose... and since I was there, also a longer extension cord. You should mention the hanging kit: as a consumer, I found that the hanging kit is **A MUST HAVE** - I ordered it along with the dehumidifier and boy, I was glad I did as it made the work of lifting the unit and leveling the unit, a breeze.
@benevolentautore4463
@benevolentautore4463 6 жыл бұрын
Any advice for ice on the condenser fins? 2 year old Advance 2 model.
@goosecouple
@goosecouple 7 жыл бұрын
A dehumidifier does not need a drain trap.
@ChrisGross034
@ChrisGross034 5 жыл бұрын
So what, it'd take the water it's creating and just dump it on the floor to then increase RH% thus needing to create an infinite cycle?
@davekalish2653
@davekalish2653 4 жыл бұрын
@@ChrisGross034 the bucket isn't the trap... It's the dip in the hose. The question is whether the hose need a dip or can it just run downhill all the way to its destination.
@jak30341
@jak30341 3 жыл бұрын
READ THE MANUAL
@BigFarm_ah365
@BigFarm_ah365 2 жыл бұрын
No, the little homeowner ones do not. This video does not pertain to those
@BigFarm_ah365
@BigFarm_ah365 2 жыл бұрын
@@davekalish2653 The big ones create negative pressure and will suck in air through the drain port, not release the condensate, overflow the catch tray and spill everywhere
@Fatelvis2
@Fatelvis2 9 жыл бұрын
I have a stand alone dehumidifier in the winter the coils freeze would the same thing happen with this unit
@ije1978
@ije1978 10 жыл бұрын
There looks like something is wrong with the video