Free Second Opinion AC Repair
0:30
$20 check up
0:19
4 жыл бұрын
Another Amana Coil blowout
1:03
4 жыл бұрын
Air Conditioner Repair
0:53
11 жыл бұрын
Пікірлер
@thehuguenot5615
@thehuguenot5615 Күн бұрын
7 years later, i wonder if he feels the same.
@FastAffordableAir
@FastAffordableAir Күн бұрын
Yes I do. Not sure how the A2L will play out.
@FastAffordableAir
@FastAffordableAir Күн бұрын
Next year's A2L may change things.
@TheKarout12
@TheKarout12 Ай бұрын
you could not include your number in all that words and love to be your contractor give us a call cal what number you did not provide any number
@onlyulee866
@onlyulee866 3 ай бұрын
What if it used a piston do I change the size smaller or bigger
@SxSRentalVegasOffRoadTours
@SxSRentalVegasOffRoadTours 3 ай бұрын
If you pull up a piston chart for r410a and R22 you will see that the piston sizes are very close. Most 5 tons use an 88-93 for either refrigerant depending on brand. Rarely will it require a change.
@onlyulee866
@onlyulee866 3 ай бұрын
@@SxSRentalVegasOffRoadTours if you use R410, how much can you put when you have A/H design for R22. I don't know what refrigerant is in the equipment. How do you determine what refrigerant is in the equipment
@tedhicks5431
@tedhicks5431 3 ай бұрын
On my comment I ment to say I wouldn't do it on a heatpump pardon me
@tedhicks5431
@tedhicks5431 3 ай бұрын
I would heat pump but I would straight cooling gas heat. Till this day at a school we have 12.5 ton straight cooling rheem unit on a carrier commercial airhandler with 410A txvs been cooling for 8 yrs . Two others also at other schools
@The1realro
@The1realro 4 ай бұрын
I need to see this install
@suezq74
@suezq74 5 ай бұрын
No you cannot. That’s because the R410A compressor will break if it’s fed R22, and R22 and R410A have different pressures. So I advise you do not use an R410A condenser on an R22 system. Otherwise it’s for your system
@FastAffordableAir
@FastAffordableAir 5 ай бұрын
Hey suezq74. Thank you for the for your comment. Do you know what the PSI rating was for coils manufactured in the 70s 80s and 90s? 350 - 500 seems to be the norm. Do you know what the 410a operating pressure is at the evaporative coil? On a straight cools, it will range 135-175. The head pressure stops gets up to 470 psi on a hot day. Since this pressure stops at the metering device the coil is never going to see this PSI.
@user-hu7ox4vn3j
@user-hu7ox4vn3j 6 ай бұрын
do you have to change the metering device to match the 410 condenser or will the r22 metering device work
@roger3858
@roger3858 9 ай бұрын
Thank you for this… your honesty….sharing your wisdom… going against the narrative! You saved me lots of money!!! God bless you .
@TheFreeman4955
@TheFreeman4955 10 ай бұрын
Anyone ever put a 410A compressor in as replacement for an R22? Then switch gas to say MO-99? I know that a R22 compressor won’t work for long in a 410A unit. I found one once. The high pressure bypass in the compressor releases when the pressure gets too high. But with R22 compressors getting hard to find I’d like to try a 410A compressor in a R22 condenser running MO-99.
@richardfallucca8222
@richardfallucca8222 11 ай бұрын
How to change orifice size
@johnprivitera7021
@johnprivitera7021 11 ай бұрын
Great video and explanation. I have 2 Spacepak high velocity systems in my attic. One for each floor. Both R22 condensors need to be replaced. Every HVAC contractor I've spoken to wants to replace the whole system. (including all the inside equipment) Do you know anyone in the Andover MA / Boston area willing to work with me on this project. Any information would be appreciated. Thank you.
@cloud9er777
@cloud9er777 11 ай бұрын
I'm Anthony from ct been doing this for more than 20 years this guy is correct I work for the government in high rises it works
@johnalves1623
@johnalves1623 10 ай бұрын
Anthony do you service units in CT?
@chrisnorris1379
@chrisnorris1379 11 ай бұрын
My change outs take 4 to 5 hours. Inside and out. And everything on it is perfectly square with everything zip tied and clean looking.
@rhymereason3449
@rhymereason3449 Жыл бұрын
I wish this guy was in my area - I'd hire him in a minute for his honesty, willingness to be flexible and lack of arrogance. All three criteria seem to be missing in 90% of the HVAC contractors in my area.
@FastAffordableAir
@FastAffordableAir 11 ай бұрын
Hope you find someone that can help you with your AC. BTW where do you live?
@MaxInLasVegas
@MaxInLasVegas Жыл бұрын
hahahahah I need an AC Tune Up for my AC system in Las Vegas
@MaxInLasVegas
@MaxInLasVegas Жыл бұрын
So true, you need to go to an Honest AC Repair Company especially in Las Vegas
@alexander_3923
@alexander_3923 Жыл бұрын
Are u guys hiring i am in vegas im 19 but i am very interested in working in hvac
@konstantinosvassilopoulos2162
@konstantinosvassilopoulos2162 Жыл бұрын
Great example of why homeowners should work with contractors that offer 10 years of labor. Trinity Warranty Solutions is one of the best extended warranty providers in the industry.
@daviddunn9898
@daviddunn9898 Жыл бұрын
Do not show me this add it's a scam
@mhammer5
@mhammer5 11 ай бұрын
Not a scam if it works in most situations.
@Theatrelove
@Theatrelove Жыл бұрын
this is bad idea contamination is for sure left behind that r22 , it will breakdown the 410 compressor and condenser.
@Theatrelove
@Theatrelove Жыл бұрын
the problem is that r22 coil cant handle the 410 pressure, alot of those r22 were done 30 years ago they have soft soldier joints , putting a 410 with alot higher pressure on those joints your asking for a leak .
@stevenb9913
@stevenb9913 Жыл бұрын
I work a industrial hvac job. We have a few systems that are very old R22 evaps ill guess 40ish years old with newer 410 condensors running R22 and they work. Also a same system runni g R458 but the 410 cond has a R22 comp.
@slidewaze
@slidewaze Жыл бұрын
You are the folks I want working on my air. The fact that you are used to the needs of a system operating in our desert heat helps a lot. (Pahrump) Sub'd, and emailed. And any news or video on the system you guys put together with the mixed refrigerants and R22/R410a hardware mashups?
@slidewaze
@slidewaze Жыл бұрын
Just watched your video. Awesome! Do you service Pahrump? I've had an R410a condenser on an R22 Evap for 9 years now. So far, so good. I did notice the current draw on the compressor does go pretty high when it's 114° out but seems to still work. Rated at 21.5 R.L.A and I've only seen it above that when the cap was going out. No response here after 11 months. I'll try calling your office.
@aaronjohnson4597
@aaronjohnson4597 Жыл бұрын
410a ac with old r22 coil works perfectly fine with piston, actually I found the really old coil without piston works even better . I'm so sick of these contractors that are so scared to adapt and overcome because its not by the book of large distributors making tons of money. You can always give an estimate to put a matching evap coil in at a later date . Not everyone can afford a BMW but dammit there's nothing wrong with a chevette
@slidewaze
@slidewaze Жыл бұрын
Chevette? You had to use the Chevette for your example? Why not Corolla or Datsun or anything else where the steering wheel is at least on the centerline of the dash and the driver. :^) Your comment is spot on, I'm just having a little fun here. Have a great weekend.
@chrisc9300
@chrisc9300 Жыл бұрын
What if the Home warranty company is only replacing the Condenser with a 410A and leaving the coil old R22. Then they will deny the claim on the work they did later? SMH
@SxSRentalVegasOffRoadTours
@SxSRentalVegasOffRoadTours Жыл бұрын
Since I made this video 5 years ago the practice of replacing 410A condenser has only, is much more widely accepted. Homewarranty companies are even doing it. I'm sure you will be fine with the warranty.
@jasoncurrie2500
@jasoncurrie2500 Жыл бұрын
What everyone needs to understand is that this is a temporary fix. A properly installed system will last a customer 20 to 25 years. Why would you want to do this to your customer. Would you let your mechanic put a part on your vehicle that was not rated for your car just because he can make it work and save you a few dollars up front? The EPA will be phasing out the new 410A refrigerant in the near future customers will be faced with a bigger problem. This is why manufacturers are requiring companies to jump through hoops for warranty parts because of unprofessional service companies such as this. I feel sorry for the customers who get involved with this kind of workmanship. Sometimes the hard truth is better. I've had many customers who wanted to try things like this in the past, but after helping them dodge a bullet they always come back and thank me later.
@walterwiebach6644
@walterwiebach6644 Жыл бұрын
Very nice video!
@mub.lakers4life
@mub.lakers4life Жыл бұрын
OMG this info was so helpful ive been going crazy all the companies i contacted say they cant make a r22 unit work with a new hvac system.
@brianlee677
@brianlee677 2 жыл бұрын
Thx for the info our ac condenser is failing at 20+ years old and here in AZ it's too hot to do without hopefully I can find someone to do this reasonably.
@stevealoia
@stevealoia 2 жыл бұрын
So now I have been told . That some guys here in NY have been using 410a condenser with 407c . They remove the 410a refrigerant . And putting in 407c . Has anyone heard of that .
@apostolosgeorgiadis3670
@apostolosgeorgiadis3670 2 жыл бұрын
If i put r22 in a new air condition will it work more efficiently?
@tombrowne9600
@tombrowne9600 2 жыл бұрын
I don't think it will work more efficiently. Though the pressures are much different the ratio of the high side to the low side is about the same. Additionally, r22 uses Mineral Oil while 410a uses Polly Ester Oil. If it works it will not stay working for long.
@jacquesdaoud4263
@jacquesdaoud4263 2 жыл бұрын
i always change the condenser and the TXV and just work great the only thing the 410a makes more condensate water
@fenflyer
@fenflyer 2 жыл бұрын
R410a 10 KW inverter split ,just out of warranty (12 months old) condenser coil split ,lost all refrigerant from leak, brazed up coil leak with silver solder. Refilled system with R22 reclaimed filtered refrigerant as emergency repair... Year later it's still running lot sweeter on R22 heating lot better, no more leaks 🤞 Just subbed 👍
@danielpensyl4382
@danielpensyl4382 2 жыл бұрын
Fair enough. Why are so many contractors B/S'ing me?
@memphismafia22
@memphismafia22 2 жыл бұрын
Need you in Texas! Thanks for this video! I have a 4Ton Goodman R22 and a Coil that says "Suitable for R22 and R410a" Im hoping my warranty will still be valid.
@johnables1902
@johnables1902 2 жыл бұрын
After seeing this video and the credibility of this guy I decided to replace my 4 ton r22 outside unit that died with a new 4 ton r410 unit. I am certified and do my own work, and I can say that the new system is working perfectly with no noticeable difference! Thank you fast affordable Air for being honest! I now know I can do this when necessary.
@h.findley3890
@h.findley3890 2 жыл бұрын
So you didn't have to replace anything inside right?
@grabir01
@grabir01 Жыл бұрын
How did you flush out the old oil?
@bbaothaitu
@bbaothaitu Жыл бұрын
@@grabir01 Nu-Calgon RX11 flush kit
@Gabriel_chicken
@Gabriel_chicken 11 ай бұрын
Did you use a txv with the 410a condenser
@johnables1902
@johnables1902 11 ай бұрын
@@Gabriel_chicken no you have to use a fixed piston
@mohamedmoussa7524
@mohamedmoussa7524 2 жыл бұрын
I have a question can I use 3 ton R410a condenser 0n 4ton R 22 evaporator thank you
@SxSRentalVegasOffRoadTours
@SxSRentalVegasOffRoadTours 2 жыл бұрын
You will need a 3 ton metering device.
@mohamedmoussa7524
@mohamedmoussa7524 2 жыл бұрын
​@@SxSRentalVegasOffRoadTours is3 ton piston will work or txv? and thank you so much you are the best
@SxSRentalVegasOffRoadTours
@SxSRentalVegasOffRoadTours 2 жыл бұрын
@@mohamedmoussa7524 either will work.
@mohamedmoussa7524
@mohamedmoussa7524 2 жыл бұрын
@@SxSRentalVegasOffRoadTours again thank you so much
@pimpindnice910
@pimpindnice910 2 жыл бұрын
Anyone have a link to a good txv?
@patricklutsch8327
@patricklutsch8327 3 жыл бұрын
I live in vegas. My system was done this way a few years ago. Half of the system us from 1989. Blower motor died after 118 degree weekend. Called popular name to have it replaced. The guy tried hard to sell me a new system for 14k for my 1200 sqft house. Which would have meant two days without air. He agreed to install just the blower motor $1400. Over price but i was desperate. He managed to damage a wire from the thermostat and couldn't get the unit to work. He left and said a senior tech would come out and figure it out. The second guy figured out what was wrong real quick and fixed it offered a new thermostat at the lowest price a could fine online checked out the rest of the system and said it was working great. He said his company doesn't install them this way but obviously was working fine. Point off the story as a customer Im thankful for this option. Vegas is hot and hard on ac units. I get companies have to charge more out here because of the conditions they are working in 118 degree ling days.... But 14k is just trying to take advantage of desperate people. My power bill averages $100 a month so the energy saving of a newer system wouldn't pay for itself. Nor would my house sell for much if anymore because of the new unit. I am real thankful for you guys who offer other solutions. As for a business model sure you don't charge as much this way but it doesn't take as long or cost you as much to do. Profits could be better for you while saving your clients money also. Would you go out and buy a whole new car just because one part failed? For 14k I could of got a new car with a working a/c system. Anyways thanks for the video.
@craigsmithx
@craigsmithx 3 жыл бұрын
Extremely reasonable.
@mercury90hp
@mercury90hp 3 жыл бұрын
Its simple...You put a 410A condenser that has the scroll type compressor and charge it with a R22 drop in replacement. Been running strong for 5 years. It is incredibly efficient. The electric bill went down and the air is Ice Ice cold. Just sayin
@igorarutyunyan811
@igorarutyunyan811 2 жыл бұрын
Wow I like that idea. Really worked?
@matthewportnoy4146
@matthewportnoy4146 3 жыл бұрын
Thank you! I beat out my competition 99% of the time by just replacing the outdoor unit and modify the evap via 410a TXV or mostly flowrater with zero callbacks! Thank you for the confirmation
@FastAffordableAir
@FastAffordableAir 3 жыл бұрын
I catch a lot of hate mail on this. I have for many years. This year there is a big shortage of indoor coils. We are seeing it already. When that happens the only option is to replace the compressor. There is definitely a shortage of compressors too. All these haters are going to see the light soon.
@matthewportnoy4146
@matthewportnoy4146 3 жыл бұрын
@@FastAffordableAir to hell with them. We provide a service and satisfy our customers the fastest and best way we can. I have been replacing outdoor units because compressor changes are more labor and other components on the unit could go bad right after. I simply replace the outdoor unit and modify the evap. Never had an issue in 41 years. What ever makes money, satisfies the customers and is done quickly! Best of luck no hate here.
@pimpindnice910
@pimpindnice910 2 жыл бұрын
Link for a good txv kit?
@johnnyriser8519
@johnnyriser8519 3 жыл бұрын
Hello. Your video is very informative. I have a 3.5 ton R-22 condenser unit whose compressor has shorted out. Could this R-22 condenser unit be replaced with a 4 ton R-410a condenser unit, and R-22 refrigerant be used? ...Or would you recommend me using another refrigerant? Also, would the orifice need to be changed? If so, what size orifice? Any other changes? Thanks.
@stevegarlock4269
@stevegarlock4269 3 жыл бұрын
You would not use R22 and the orifice in the coil would be swapped out is my understanding. You will obviously need to do a line and evaporator flush.
@theduffster2581
@theduffster2581 3 жыл бұрын
Just replace both why take a chance????
@SxSRentalVegasOffRoadTours
@SxSRentalVegasOffRoadTours 3 жыл бұрын
I always recommend the replacement of the coil furnace and condenser for efficiency and reliability. But when money is tight this restores cold air. It can do no harm to the existing coil.
@henkdeswardt8636
@henkdeswardt8636 3 жыл бұрын
Fantastic video. Great job!
@wildatheart3182
@wildatheart3182 3 жыл бұрын
Good relationship 🤣
@john7017
@john7017 3 жыл бұрын
Can I take a new R410A condenser, recover unit refrigerant, recharge with R407C and connect to a existing R22 system? Flushing existing system of coarse.
@FastAffordableAir
@FastAffordableAir 3 жыл бұрын
I have never done that. I have put 410a in a r22 condenser and it is still working though not well. Only hase a 13 degree split.
@heatingairservices8708
@heatingairservices8708 3 жыл бұрын
@@FastAffordableAir wow never done that good to know bc so much hype in this business that's simply not true but we dont know till someone tries it & its WORKS Thanks
@raycut8
@raycut8 3 жыл бұрын
Are you still alive?