Пікірлер
@Thediecastvault
@Thediecastvault 3 күн бұрын
How can I check nox sensors??
@JohnDoe-pl8iv
@JohnDoe-pl8iv 7 күн бұрын
Whats the dimensions of your pool? Also how many bags of plaster did you wind up using? I heard you say you put down some bonding agent before you put the dark cement into all the holes.
@alreyindustries
@alreyindustries 7 күн бұрын
@@JohnDoe-pl8iv store.sider-crete.com Call these guys: 1-888-743-3750 Tell them your pool size and how many gallons and such. They were helpful when I did mine. I ended up ordering 11 bags. They sell everything you need and the bonding agent.
@deepbhullar2784
@deepbhullar2784 12 күн бұрын
Thanks my 2024 same issue cruise control not responding some time
@vad102
@vad102 13 күн бұрын
Thank you sir
@T680-MKE
@T680-MKE 21 күн бұрын
Does this cause 3382 code??
@alreyindustries
@alreyindustries 21 күн бұрын
@@T680-MKE yes. This COULD be the cause of it.
@abelgallegos2056
@abelgallegos2056 23 күн бұрын
Exactly what I was looking for. I appreciate you sharing the knowledge and tips.
@quatruckin5548
@quatruckin5548 25 күн бұрын
When I was replacing my seal I noticed oil on my fuel injector line the part that goes through the seal is that normal?
@alreyindustries
@alreyindustries 25 күн бұрын
@@quatruckin5548 yes
@7thfloorisnomoreq790
@7thfloorisnomoreq790 26 күн бұрын
What does that nipple do? What problems does it cause if its broken?
@alreyindustries
@alreyindustries 26 күн бұрын
@@7thfloorisnomoreq790 it’s a spring loaded bypass valve. If it breaks off, parts of it can get into the engine and possibly cause damage.
@davidfs.6233
@davidfs.6233 27 күн бұрын
I have spn3480 fmi21
@Truckdiver9
@Truckdiver9 28 күн бұрын
Thank you. How often should they be replaced?
@jasonwade9804
@jasonwade9804 29 күн бұрын
Mine is broken and I’m unsure for how long, should I check/replace main bearings??
@alreyindustries
@alreyindustries 29 күн бұрын
@@jasonwade9804 there is a recommended procedure for that issue. There are other videos on KZbin that detail what to do if it is broken. It is up to you if you want to go through that process or just replace it and hope for the best. I have seen many broken that did not cause major engine damage but you never know.
@MiamiGeneralContractor
@MiamiGeneralContractor 29 күн бұрын
good work man looking at doing it to mine, how is it lasting so far?
@alreyindustries
@alreyindustries 29 күн бұрын
@@MiamiGeneralContractor thanks. It’s been two or three years and I have no complaints.
@cedthetruth1311
@cedthetruth1311 Ай бұрын
Hi.I have the same issue on my 2011 Cascadia it regens but the temps don’t get high enough then the system aborts the regen. I already cleaned out the 7th injector and de sooted the manifold pipe..I pulled that high pressure flang just as you did on the video and sure enough that control valve is blowing air like a whistle.. Could my problem also be that 2 stage DOC block mounted above the fuel pump as well? Your video on YT is the only one that says anything about that control solenoid could prohibited the regen process..Thanks for any info you can provide..
@alreyindustries
@alreyindustries Ай бұрын
@@cedthetruth1311 if that valve is bad I’d say that is most likely your culprit. I’d check for any exhaust leaks as well. Look for soot anywhere around the exhaust system before the DPF.
@DemonsBurnis
@DemonsBurnis Ай бұрын
How do you know if the actuator need calibrated
@alreyindustries
@alreyindustries Ай бұрын
@@DemonsBurnis the actuator needs to be calibrated any time it is removed. If you take the old one off or if you put a new one on. Calibrating the actuator is not a fix. If you’re having problems with the turbo or actuator calibrating it will not help.
@sherzai2708
@sherzai2708 Ай бұрын
Why does that injector fuel always leak?
@alreyindustries
@alreyindustries Ай бұрын
@@sherzai2708 fuel or oil?
@mrculpepper30
@mrculpepper30 Ай бұрын
I’m doing an engine swap dd15 to ddec 6 14.0L I have some programming ?s
@sukhjitsingh2504
@sukhjitsingh2504 Ай бұрын
Such a great video, with ton of knowledge. I have a question for you sir. Does it mean, it’s a bad turbo, if u find some oil in the actuator housing( where the turbo shaft is attached to actuator teeth)? Recently I have a replaced my actuator and found some oil there but don’t have any loss power or codes. Turbo shaft also turn smooth from left to right, just a tiny more pressure needs to be applied once get to right end. Could u pls advise? Also is there a contact, where I can get hold of you? Also have this other weird issue that no one seems to figure out. I can explain that better over the phone than typing it. Thanks
@alreyindustries
@alreyindustries Ай бұрын
@@sukhjitsingh2504 there are seals inside the turbo that go bad and allow oil to pass into the actuator. There should not be oil in the actuator when you take it off. So, yes technically the turbo is causing that problem. You may not have any problems now but you may be replacing actuators more frequently and eventually see turbo problems. But it is a personal decision as to whether or not you want to replace the turbo or let it go until it gives you further problems. I don’t work in this field anymore. If you want to try to type out your other question here I’d be more than happy to try to answer. If not, I don’t have a contact number to give. Sorry. Glad this video helped you out.
@madangclassic
@madangclassic Ай бұрын
Yes very helpful and exact diagnostics with computer, thank you
@inderveerbilling
@inderveerbilling Ай бұрын
@alreyindustries Yes i do manual regen of 45 mins.. and it clears the sign of regen until next 700 kms. Mechanic said DOC INLET PRESSURE is 1.1 .. may be that is why asking frequent regen
@inderveerbilling
@inderveerbilling 2 ай бұрын
Where can i check online , which latest software versions are available for modules for my truck? 2016 cascadia dd15
@grmonkey0
@grmonkey0 2 ай бұрын
I bought my western star with dd16 . I have had it 5 years. DEF issues is nonstop. I get nox conversion codes every time i pull a hill. Ive tried many different things. Truck been to Detroit numerous times. Nothing they have tried fixed my issue. This def awning is my next try
@inderveerbilling
@inderveerbilling 2 ай бұрын
Mine is 2016 cascadia.. having too frequent regen issues? 1. Can updating any of these softwares ( acm, ecm, cpc etc) solve the issue? 2. How do i check software version myself. Right now it says some software# in icu info on my truck. What is that?
@alreyindustries
@alreyindustries 2 ай бұрын
@@inderveerbilling it is possible it could solve the issue. If I was a betting man I’d say it is probably not a software issue but it is always best to make sure your software is up to date before troubleshooting. To check your software versions you would have to have the Detroit software like you see in the video. The software number you see in the instrument cluster is the software number for the instrument cluster itself. Even the instrument cluster has software. Hope that helps.
@inderveerbilling
@inderveerbilling 2 ай бұрын
⁠thanks for ur reply. How much it costs for updating all these softwares? Also do you know what is difference in dpf zone 1 and zone 2 setting on truck. Recently dealership changed my truck setting to zone 1 from zone 2 to see if it cud solve regen issue as i drive in city?
@alreyindustries
@alreyindustries 2 ай бұрын
@ last time I checked, if you have the software, Detroit charges $200 per updating event. I’m not sure if that means each module or all modules. The reason you change DPF zones is to program the truck to do a regen when the soot level is lower. Your DPF is a big filter that catches soot from your exhaust. It has sensors on it that read the pressures on either side of the filter. If it is in zone 0 it will tell the truck to do a regen when the pressure in the filter is at a lower level. When it is in zone 3, it will wait to tell the truck to do a regen until the pressures are at a higher level. The pressures indicate how much soot is in the filter. The regen gets the DPF hot enough to burn the soot and make it ash which clears up the filter. If you are regenning too frequently it’s because the filter is filling up with soot too often or you have faulty sensors. A regen requires the engine to be on at a high idle and for a significant amount of time to pass so that it can reach the required temperature for the required amount of time in order to burn off the soot. When you are driving in the city, the truck is often not able to reach those temperatures or maintain them and so the truck does not do a full regen. You can try to put the truck into a manual regen when convenient for you each day and make sure to let it run its course until it is finished. It is also possible that there is a fuel issue. The after treatment system requires diesel fuel in order to heat up and that can cause the truck not to be able to get to the required temperature as well.
@inderveerbilling
@inderveerbilling Ай бұрын
@@alreyindustries thanks for the info.. Can we program any module of truck so that it does active/automatic regens at low temp during mixed city/hyw driving?
@alreyindustries
@alreyindustries Ай бұрын
@@inderveerbilling you would have to go to the parameters section and find the DPF tab under the ACM (after treatment control module) and change it to 0. Having it at zero programs the computer to do regens at the lowest soot level which may help with your problem.
@ExTrEmEGaMeR-wo8pk
@ExTrEmEGaMeR-wo8pk 2 ай бұрын
Hey brother after all that work how do you clean all that oil on from the tube so it won't go to the engine fuel system because I did all of that but the truck is smoking a lot how to clean all of that oil
@parmguraya2140
@parmguraya2140 2 ай бұрын
Part number really helpful for me dealership said sometime its fit or sometime not but its work thank you very much
@amandaandgabriel5950
@amandaandgabriel5950 2 ай бұрын
Can I clean the sensor ports with carb cleaner?
@alreyindustries
@alreyindustries 2 ай бұрын
@@amandaandgabriel5950 it’s probably not recommended by the manufacturer, BUT as long as you make sure it is dry before putting it back together you should be ok. The two ports at the bottom of the sensor are sensitive to pressure so be aware of that.
@amandaandgabriel5950
@amandaandgabriel5950 2 ай бұрын
​@@alreyindustries I got code p040313 and my vovlo is a 2017 630 with a d13. Does this video refer to that code? Also I really appreciate the help. I'm a new owner operator and any way I can save money and fix it my self will definitely help.
@alreyindustries
@alreyindustries 2 ай бұрын
@ from what I saw online (I don’t have the software anymore), it looks like this code is referring to an open circuit at the EGR valve. Check the wiring at the EGR valve connector and harness. And if you know how, check the voltage and ohms at the connector of the EGR valve.
@amandaandgabriel5950
@amandaandgabriel5950 2 ай бұрын
@alreyindustries okay I'll check this weekend. I'll have a little down time. Also I'm gonna clean the sensor you was referring to n in this video. I'll keep you updated. Thanks for everything
@javiervargas3995
@javiervargas3995 2 ай бұрын
why did you change it? what were the symptoms before replacing it?
@alreyindustries
@alreyindustries 2 ай бұрын
@@javiervargas3995 truck wouldn’t start. The valve was stuck open so the engine couldn’t maintain proper fuel pressure.
@MichaelCanales-t7k
@MichaelCanales-t7k 2 ай бұрын
Awesome video
@soundsofthesoul8719
@soundsofthesoul8719 2 ай бұрын
Hello how caí get get a hold of you?
@alreyindustries
@alreyindustries 2 ай бұрын
@@soundsofthesoul8719 I don’t work in the trucking industry anymore. But if there is a question I can answer for you here I’d be more than happy to try to help.
@AngelEyes-xm7el
@AngelEyes-xm7el 2 ай бұрын
So the so callerd professional trucker mechanic never heard of this. Now it will not run. He said I ignored it. 100k truck new 2007 i think it is destroyed.
@alreyindustries
@alreyindustries 2 ай бұрын
@@AngelEyes-xm7el I doubt it’s destroyed. What’s happened?
@grecocjg
@grecocjg 2 ай бұрын
How do you clean the grid heater without all the gunk going into the intake?
@alreyindustries
@alreyindustries 2 ай бұрын
@@grecocjg shop vac and flat head screw driver was my preferred method
@alreyindustries
@alreyindustries 2 ай бұрын
@@grecocjg I mean, all that stuff was already going into the intake, but I was usually able to avoid getting much in there by using a shop vac
@grecocjg
@grecocjg 2 ай бұрын
Can the grid heater come out for cleaning? Tks
@alreyindustries
@alreyindustries 2 ай бұрын
@ it can but it’s a pain. I never took it out because you have to remove all the fuel lines and I think the rail. I don’t think it’s worth it. But it can.
@jadbeth-396
@jadbeth-396 2 ай бұрын
Where is your shop located???
@FickeyH
@FickeyH 2 ай бұрын
👍👏
@jeffbrooks8118
@jeffbrooks8118 2 ай бұрын
Thanks man!
@Prince-dh8oh
@Prince-dh8oh 2 ай бұрын
It's easier with the new filter system from 2015 and up or 2014 and up.
@jhoan023hernandez
@jhoan023hernandez 2 ай бұрын
Hello, I would like to know if there is anyone here in Houston, Texas who has experience repairing pools?
@locovidepro
@locovidepro 2 ай бұрын
Bro, I am working on mine right now 10/22/24 in Spring Hill, FL. Mine, I ended up scraping almost the entire plaster, since the Roll-On plaster can be applied over concrete as well so that is my plan. So, to me so far have been very hard, but I can almost see it finished. I appreciate you making of this video. It will help me to pay attention to when I put the tape over the ceramic and to make the concrete more wet to be able to applied and make a smooth finish. Thank you so much.🙏
@alreyindustries
@alreyindustries 2 ай бұрын
@@locovidepro I’m in new port richey. Not too far from you. It’s been over two years now and still holding up pretty well. Good luck.
@locovidepro
@locovidepro 2 ай бұрын
@@alreyindustries that's so cool, we are neighbors😁. We, you are welcome to see the process of my pool progress. Maybe you can give me advise or perhaps, learn something that might help down the road. Let me know and I will send my address. I will be here working for the next four or five days.
@cyrilbarnett52
@cyrilbarnett52 2 ай бұрын
The truck just won't start and that's the only thing that came up in the computer
@alreyindustries
@alreyindustries 2 ай бұрын
@@cyrilbarnett52 is it cranking and not starting or is it not cranking at all?
@cyrilbarnett52
@cyrilbarnett52 2 ай бұрын
Yes is cranking but just won't start
@alreyindustries
@alreyindustries 2 ай бұрын
@@cyrilbarnett52 then I’d say it’s most likely that you have a fuel issue.
@cyrilbarnett52
@cyrilbarnett52 2 ай бұрын
Should that cause the truck not to start
@alreyindustries
@alreyindustries 2 ай бұрын
@@cyrilbarnett52 no. This will not cause your truck not to start.
@cyrilbarnett52
@cyrilbarnett52 2 ай бұрын
Hi good morning
@bleusmyboy
@bleusmyboy 3 ай бұрын
I use the TerraClean tool and products to clean the entire system in about 1.5 hours. I do not have to remove the valve, I hook in at the temp sensor, remove the egr actuator, and replace it with a thumb screw plate so I can open and close the valve. The system cleans the intake, grid heater and the combustion chamber,egr, egr cooler, turbo, and dpf. Basically everything "tip to tailpipe" Excellent video however, the TerraClean system has been life changing.
@1waukesha
@1waukesha 3 ай бұрын
You ain’t kidding on those bolts being a bear to remove. Fighting with one right now. Three came out, but one is stripped. So I tried using a chisel to knock it loose but instead sheared most of the head off. Ahhh, good times. I expect to see carnage once im in. The truck died and is crank no start now with only about 175 psi of rail pressure.
@akhytzhandos3043
@akhytzhandos3043 3 ай бұрын
Hey, thank you very much for your video. Right now, I’m changing my VGT by myself, and I don’t have any computer programming tools. How can I do the computer programming after replacing the VGT? Should I go to a shop after the installation to get it programmed, or does it need to be programmed before installing the new VGT? Could you answer my question, please? Thank you.
@alreyindustries
@alreyindustries 3 ай бұрын
@@akhytzhandos3043 it has to be programmed before and after installation so you should take it somewhere with the software.
@johnt8160
@johnt8160 3 ай бұрын
Can I come to you for an transmition soft update?
@gtgeneraltuning5215
@gtgeneraltuning5215 3 ай бұрын
How to get password…?
@yevgenaleksyeyenko8291
@yevgenaleksyeyenko8291 3 ай бұрын
Thank you
@dukeduke7569
@dukeduke7569 3 ай бұрын
What was the other sensor beside it???
@Boxtruckin
@Boxtruckin Ай бұрын
Left is oil temp right is oil pressure
@servando1049
@servando1049 3 ай бұрын
Thanks for the information but it would be nice if you used a pointing stick or your finger to show us what your looking at.
@alreyindustries
@alreyindustries 3 ай бұрын
@@servando1049 yea I thought about that after watching the video again. If you have a question let me know. I’ll try to answer it for you.
@martianmusicllc
@martianmusicllc 4 ай бұрын
Thank u
@tonytorres7417
@tonytorres7417 4 ай бұрын
Can you put the part number
@hartfordautocenter
@hartfordautocenter 4 ай бұрын
You should take off the chip from old cluster and put it in the new cluster to have the right mileage otherwise you will have check engine light on