@patmat.
@patmat. 16 күн бұрын
"The 10V cones from the fixture" ... You lost me, the fixture doesn't output a voltage, it's not a power supply.
@prudalavage
@prudalavage 16 күн бұрын
The 10 volts for the 0-10 signal is generated at the fixture
@Sparky-ww5re
@Sparky-ww5re 23 күн бұрын
Since the LED driver (or less common, dimmable fluorescent ballast) is what provides the 10 volt DC output for dimming control when powered up via line voltage, I'm guessing the actual dimmer switch is basically an on/off switch with a variable resistor for the low volt wires? Or am I misunderstanding something here?
@prudalavage
@prudalavage 23 күн бұрын
You are correct. The dimmer is an on/off switch with a variable resistor for the low volt wires.
@supernova8962
@supernova8962 Ай бұрын
why is there two line going in the switch voltage ...you only explain one line...what about output
@prudalavage
@prudalavage Ай бұрын
Line in to the switch and load out to the lights. The 0-10 wires get connect at the dimmer then daisy chain to every light.
@BobBobbingsworth
@BobBobbingsworth 2 ай бұрын
Replace with switches
@MatthewValdes-v9y
@MatthewValdes-v9y 5 ай бұрын
Obviously everything connects to each other so it can function. But theres a lot more to it Einstein.
@RChobbiespro
@RChobbiespro 5 ай бұрын
Turning the red dial to the right increases the sensitivity or decrease?
@prudalavage
@prudalavage 5 ай бұрын
Dial to the right increases sensitivity
@RChobbiespro
@RChobbiespro 5 ай бұрын
Thanks for the clarification 👍🏻
@olegproscurchin8200
@olegproscurchin8200 5 ай бұрын
Is it only me who didn’t get how to connect the switch? Do I need to connect the power too or just the two 0-10V cables.?
@prudalavage
@prudalavage 5 ай бұрын
You need to connect line voltage to the switch and low voltage to the two 0-10 volt cables
@smash72cutlass30
@smash72cutlass30 7 ай бұрын
If you could talk a little about the code involved with mixing class 1 and class 2 the dimming appears to be on the class 2 section of the power pack. If I’m right I’d need to carry line voltage gauge wire to the fixture. Ever try and put a 12/4 MC cable into one of these LED fixtures. It’s pretty tight. Or am I missing something. The 0 to 10V gauge from the fixture is like 18awg in the same raceway of the fixture.
@prudalavage
@prudalavage 7 ай бұрын
Thanks for the comment and i will cover the class 1 and 2. Most contractors use MC Luminary cable which has both line and low voltage in the same jacket.
@prudalavage
@prudalavage 7 ай бұрын
Thanks for the comment and i will cover the class 1 and 2. Most contractors use MC Luminary cable which has both line and low voltage in the same jacket.
@smash72cutlass30
@smash72cutlass30 7 ай бұрын
Is 0 to 10V dimming considered class 1 or class 2 from the power pack. I’m using sensorworx brand it appears the dimming uses one side of the relay and the other to the low voltage switch. Wouldn’t I need to carry the line voltage gauge to the fixture ? In my case would be a 12/4 to each fixture
@prudalavage
@prudalavage 7 ай бұрын
Yes, you need both line voltage and low voltage to the fixture. Most contractors us MC Luminary cable which has 12/2 and 16/2 in the same jacket.
@smash72cutlass30
@smash72cutlass30 7 ай бұрын
My confusion is with regards to the low voltage side. The driver mixes both line and low voltage in the same tiny splice area. And when looking at the diagram on the power pack sensors and LV switches are all on the LV class 1 side. However the dimming is on the class 2 side would I not need to keep the line side gauge wire to the fixture for dimming ? One side goes to the load side relay and the other goes to line side neutral. Running that 16/2 makes me nervous on a 20amp commercial circuit. Also I guess each fixture would need to go back to the driver as apposed to daisy chaining the dimming.
@SoSoGone02
@SoSoGone02 10 ай бұрын
You should do a troubleshooting video on these cause. They never work right 75 percent of the time and the info online for troubleshooting is of no help
@prudalavage
@prudalavage 10 ай бұрын
Thank you and I will add that video. Please subscribe and let me know if it is helpful
@FahibaGhouri
@FahibaGhouri 10 ай бұрын
😊😊
@zainmughal7962
@zainmughal7962 10 ай бұрын
@mrios8453
@mrios8453 Жыл бұрын
Will the sencor work with out the power pak
@prudalavage
@prudalavage Жыл бұрын
No. This is a 24 volt sensor. The powerpack provides the 24 volts and turns the 120 on and off. They do make sensors that do not require a powerpack, but that is not what i am showing here.
@EstarDeBuenaSiempre
@EstarDeBuenaSiempre Жыл бұрын
Word record video
@rahulpatil280
@rahulpatil280 Жыл бұрын
We have facing the issue of light is not off in motion mode by RMN-5R-DV-B senser controller. Light is manually on-off by push the senser butten, please share the reason why is not senser working in motion mode, please share the trouble shooting process.
@rahulpatil280
@rahulpatil280 Жыл бұрын
We have facing the issue of light is not off in motion mode by RMN-5R-DV-B senser controller. Light is manually on-off by push the senser butten, please share the reason why is not senser working in motion mode, please share the trouble shooting process.
@prudalavage
@prudalavage Жыл бұрын
Some things to check- -make sure sensor is 4ft minimum distance away from hvac vent -if there are more than one sensor, you need to check both sensors -how old is the sensor? -lutron has 24/7 tech support at 1-800-523-9466
@rahulpatil280
@rahulpatil280 Жыл бұрын
@@prudalavage please share the trouble shooting PDF file
@jenko701
@jenko701 Жыл бұрын
In most cases you will be controlling more than one fixture , how do you handle the 0 to 10 over say 20 fixtures, I would assume you just daisy chain the low voltage together. Do a video where you talk about large room , multi fixture challenges of dimming many fixtures at the same time.
@prudalavage
@prudalavage Жыл бұрын
Hi James- you are correct that you would daisy chain the 0-10 for all 20 fixtures. I do not have a video on that.
@normanm3885
@normanm3885 Жыл бұрын
All my zones went out . I have 277 going into the panel . No tripped breakers . I don’t see any LED lights on the panel lit up . Should I replace the hole panel.
@prudalavage
@prudalavage Жыл бұрын
I would call Lutron tech support. 1-800-523-9466. they can help troubleshoot
@400080vikkash
@400080vikkash Жыл бұрын
We use the third one ats makes most sense in our application, thanks for showing different ways of doing it.
@prudalavage
@prudalavage Жыл бұрын
You are welcome. Thanks for the comment!
@bryanpina5425
@bryanpina5425 Жыл бұрын
Thank you 🙏
@zacharykorbet9690
@zacharykorbet9690 Жыл бұрын
Thank you very helpful
@rahulpatil280
@rahulpatil280 Жыл бұрын
Why is not pair the senser with controller
@prudalavage
@prudalavage Жыл бұрын
The sensor and controller need to be paired. Since this is troubleshooting I am assuming they will have already have been paired.
@joeaylor
@joeaylor Жыл бұрын
Will A1 ON keep the lights on?
@prudalavage
@prudalavage Жыл бұрын
I have not tried turning the A1 on before. Give it a shot and let me know if it works.
@joeaylor
@joeaylor Жыл бұрын
​@@prudalavage A1 ON is an override. It leaves the switch on. We recently converted an area into workspace and every 8 minutes it was turning off. For the time being, we decided to just allow the lights to stay on for convenience until we can have an electrician redo the area. Thanks for the video!
@jbferrer3
@jbferrer3 2 жыл бұрын
MAN YOU EXPLAINED NOTHING LOL
@prudalavage
@prudalavage 2 жыл бұрын
I apologize. What information or answers were you hoping to find?
@fmellon5225
@fmellon5225 2 жыл бұрын
Hi Paul, this is a really cool demonstration, thank you. I have the same chandelier, but cannot find the manufacturer, and I need to replace the shade. Is there any chance you can help me? I appreciate any information you can provide.
@prudalavage
@prudalavage 2 жыл бұрын
Hi. Unfortunately I dont know the manufacturer. Best of luck finding it.
@gedionsamuel2256
@gedionsamuel2256 2 жыл бұрын
I wish there was a smart version of this low-voltage dimmer. It’s hard to find one that has it all, occ/vac sensor, 0-10v dimmer, and smart/Alexa capability. This comes close! The only other one I read about was Leviton ODD10-IDW just I’m not sure if it’s in fact low voltage dimmer (purple/grey wires).
@TheDjexcessive
@TheDjexcessive 2 жыл бұрын
dude, just start something else but not vlogging
@elalacran37
@elalacran37 2 жыл бұрын
Sorry but can barely hear.
@prudalavage
@prudalavage 2 жыл бұрын
Got it. Thanks for the feedback. I use a different mic on my recent videos
@kenlyndhurst9153
@kenlyndhurst9153 2 жыл бұрын
is there time clock control option in that panel?
@prudalavage
@prudalavage 2 жыл бұрын
A timeclock would be an additional component outside the panel. Lutron has a grafik eye part QSGRJ-6P which can be connected to it to add a timeclock. The QSN-4T16-S panel also has a contact closure input which you could connect a dry contact from a 3rd party timeclock such as the Intermatic FM1D14A-24
@kenlyndhurst9153
@kenlyndhurst9153 2 жыл бұрын
@@prudalavage thank you, I'm designing external lighting to dim 70% to 50% after mid night. So if I use QSN-4T16-S panel and Intermatic FM1D14A-24 for external lighting, QSGR-4P Base unit is still required? QSGR-4P Base unit itself has timeclock function, hasn't it?
@israelcastillo1616
@israelcastillo1616 2 жыл бұрын
So there's 2 different CRKTS
@prudalavage
@prudalavage 2 жыл бұрын
Correct. Em circuit always powers the light. Normal circuit switches it on and off. Normal circuit sense line. Lose normal sense line and light turns on regardless of switch position.
@lincolnarrieche7999
@lincolnarrieche7999 2 жыл бұрын
Ese cable comun es cual? El neutro ?
@prudalavage
@prudalavage 2 жыл бұрын
Hay bajo voltaje- 3 cables. Negro (común) Rojo (24 voltios) Azul (señal). El sensor necesita los 3. I used google translate from english.
@lincolnarrieche7999
@lincolnarrieche7999 2 жыл бұрын
Necesito un traductor al español estoy montando uno de eso y no me da la señal
@TBoy1247
@TBoy1247 2 жыл бұрын
Assuming components you show in this video, what would be a budget price add for an electrical sub to add occupancy control to a corridor requiring 2 power packs, 4 occupancy sensors? 8 LED dimming light fixtures already provided in Base Bid. New construction. Just a budget cost/fixture add for occupancy controlled dimming to get a conversations started.
@TBoy1247
@TBoy1247 2 жыл бұрын
Thanks Paul. What would change if requirement was 100% on while occupied, dim to 50% without occupancy. Can you recommend a Power Pack?
@prudalavage
@prudalavage 2 жыл бұрын
Hi Tim. I would recommend the Lutron RMJS-8TN-DV-B powerpack. This is part of the Lutron Vive System.
@NorthernLightsVideo
@NorthernLightsVideo 2 жыл бұрын
Thanks so much for this video. It helps a lot. So I understand I need to use 16 to 18 gauge wire to wire all the gray and purple wires together from light to light and then go to the dimmer switch. But gray and purple must be run separate from the 14/2 wire, per code? How many lights, that use 160 watts per light. can I use? I plan to do 6 lights with each one taking 160 watts on one dimmer switch. Will that work?
@prudalavage
@prudalavage 2 жыл бұрын
Local codes are different. I work in Philadelphia and most electricians use MC LED cable which has the power and dimming in the same cable. www.encorewire.com/products/mc-led.html. The limit for a dimming zone is the relay rating- usually 8 amps but verify. The 0-10 limit is in milliamps- which you can look up but I would feel comfortable with 6 fixtures.
@neophobicnyctophile8264
@neophobicnyctophile8264 2 жыл бұрын
Wait, so I have to run what between the dimmer switch and the lights? Two lines? What kind of wiring in my walls and ceiling should I use? If so, that means I have to tear out a LOT of drywall that took the contractors about 5 months to install. Can I just put the dimmer on the power lines to the driver box like regular lights?
@prudalavage
@prudalavage 2 жыл бұрын
Dimmers that dim over the 120 volt line (phase dim) are available and have been used for years. Your fixtures need to be built for phase dim- usually listed as “triac”. Use that type of fixture and dimmer and you don’t need additional wires. 0-10 volt dimming is usually used commercially with acoustic ceilings.
@hicksinguefield8309
@hicksinguefield8309 2 жыл бұрын
ᎮᏒᎧᎷᎧᏕᎷ
@NCSparkyone
@NCSparkyone 2 жыл бұрын
So do u have to run a separate pair of wires down from the fixture to the switch location? What guage wire?
@prudalavage
@prudalavage 2 жыл бұрын
Yes, you need to run a separate pair of wires for the 0-10 volt signal. Most people use 16 gauge or 18 gauge
@rahulpatil280
@rahulpatil280 2 жыл бұрын
RMB-5R-DV-B senser pair & unpair process need to be share
@prudalavage
@prudalavage 2 жыл бұрын
You have two options. You can factory reset the powerpack-by doing a button press of tap-tap-tap hold for three seconds then tap-tap-tap . This will unpair everything. If you want to just remove the sensor- you can tap-tap-fap- hold for 6 seconds- tap tap tap on the lightbulb button on the sensor.
@rahulpatil280
@rahulpatil280 2 жыл бұрын
@@prudalavage please share the video of pairing & un pairing process
@thomasnavarre2578
@thomasnavarre2578 2 жыл бұрын
How do you lower the light level when it comes on?!
@prudalavage
@prudalavage 2 жыл бұрын
Page 10 of this link. www.lutron.com/TechnicalDocumentLibrary/048536.pdf
@meesiphht2769
@meesiphht2769 2 жыл бұрын
Waste of time.
@abimaelyisrael858
@abimaelyisrael858 2 жыл бұрын
Thanks for this video.
@daversj
@daversj 2 жыл бұрын
If the fixture provides the 10v is there a way to add a dimmer function at the fixture? Like a circuit that attenuates the voltage? Want to retro some led panels but dont have a low voltage pair of wire to the lights.
@prudalavage
@prudalavage 2 жыл бұрын
There is a module you can put on every fixture from Lutron called the FCJS-010 which you can mount on every fixture. If you are able to run the 0-10 wire, that is usually the easiest way to dim them. Assumes you have access above the ceiling of course.
@PhearaXT
@PhearaXT 2 жыл бұрын
What does ultrasonic sensor do?
@prudalavage
@prudalavage 2 жыл бұрын
The ultrasonic senses motion by putting out sound waves and then checking how they return to the sensor. If the wave is disturbed upon return, then the sensor knows there is someone in the room disturbing the sound waves.
@HGR693
@HGR693 2 жыл бұрын
The real catcher here, is that the 0-10v line MUST be in a separate conduit, down to the dimmer switch. you are not allowed to run both the 120v and the 0-10v lines together per the NEC.
@prudalavage
@prudalavage 2 жыл бұрын
Yes that is correct and a challenge on conduit projects. MCLED allows 0-10 and line voltage in the same cable.
@HGR693
@HGR693 2 жыл бұрын
@@prudalavage I take it then that they make a special MCLED cable for just that purpose. Was not aware . Thank you.
@tylermulkey330
@tylermulkey330 23 күн бұрын
I thought so man I knew I wasn’t crazy.
@Royz1512
@Royz1512 2 жыл бұрын
Hi Paul, great video. Thank you
@prudalavage
@prudalavage 2 жыл бұрын
Hi Roy- the occupied light level setting is done in advanced settings. Search “lutron app note 536” page 10 and it will show you
@r.c.850
@r.c.850 2 жыл бұрын
Hello there... can I replace this Lutron Grafik eye switch with something new?.... How difficult is to replace it?
@prudalavage
@prudalavage 2 жыл бұрын
The grafik eye is still made and supported by Lutron if you are having an issue. Replacing it with something different would be a complete new system
@chucktaylor5878
@chucktaylor5878 3 жыл бұрын
It might be a good idea to keep the sensor on camera!
@juli115_
@juli115_ 3 жыл бұрын
Great video and straight to the point.
@MoonLight-vk3ej
@MoonLight-vk3ej 3 жыл бұрын
Great work but gently if there is wiring diagram shawing connection to lightings with dimmable drives alonge zones