Teledyne Tekmar Product Overview
2:59
Troubleshooting the Lotix
2:40
6 жыл бұрын
Configuring the Software
3:26
6 жыл бұрын
Understanding a Report
2:07
6 жыл бұрын
Creating a Sample Schedule
4:21
6 жыл бұрын
Setting Up a Calibration Curve
3:08
6 жыл бұрын
Пікірлер
@melanieshirley6733
@melanieshirley6733 8 ай бұрын
After you do the 300 flow what does it go back to.?
@TeledyneTekmar
@TeledyneTekmar 8 ай бұрын
The flow will adjust to the next method parameter that is outlined in the method. The Fusion utilizes a mass flow controller thus allowing variable flows throughout the method instantaneously.
@kevinkantize844
@kevinkantize844 8 ай бұрын
Thank you so much for a very informative session
@kcjp11
@kcjp11 Жыл бұрын
Thanks for posting. Hopefully you learned to say industrial at this point, lol. Looking for video on proper method for sampling, which is critical, isn't that 101?
@manoor6391
@manoor6391 2 жыл бұрын
IN Phoenix8000, for di water of 2ppb TOC i am getting results about 100ppb ..my raw data counts are in ranges but results are off . should i still run sulfuric acid as sample ?
@manoor6391
@manoor6391 2 жыл бұрын
if my results are not correct for standards solution , is there could be a possible problem with calibration ? or should i start to troubleshoot as described in the video first ?
@sanford8424
@sanford8424 3 жыл бұрын
Awesome content! Keep the videos coming! You should look into using Promosm. It will help you promote your videos!!!
@ANTEC-GmbH
@ANTEC-GmbH 3 жыл бұрын
great webinar, thanks for the upload
@chromatography_HPLC_vial
@chromatography_HPLC_vial 4 жыл бұрын
wow, this video introduce TOC analyze, clearly. very good
@eshwarkrishna5748
@eshwarkrishna5748 4 жыл бұрын
I'm getting higher reagent water values
@eshwarkrishna5748
@eshwarkrishna5748 4 жыл бұрын
Can u suggest any reasons
@TeledyneTekmar
@TeledyneTekmar 4 жыл бұрын
​@@eshwarkrishna5748 I would suggest contacting our technical support group at [email protected]. They will be able to help you diagnose the problem.
@eshwarkrishna5748
@eshwarkrishna5748 4 жыл бұрын
I'm getting higher reagent water values,
@calvinooi8198
@calvinooi8198 4 жыл бұрын
Hi, in mass balance equation, is Mg mean volume of mass in gas phase?
@TeledyneTekmar
@TeledyneTekmar 4 жыл бұрын
Mg stands for the mass of the sample in the gas phase. As the sample is heated, volatile compounds enter the headspace of the vial. So the combination of the mass of the sample in the gas phase and the mass of the sample matrix is equal to the original mass of the sample: Mo=Mg+Mm. In order to calculate the Mass of the gas you would need to multiply the concentration of the gas and the volume of the gas: Mg=Cg*Vg.
@mahmoudmoustafa550
@mahmoudmoustafa550 4 жыл бұрын
Please I have a question in TOC fusion I have a bad repeatability for the blank sample , as I inject it triplicate and every time I got a different reading what are the causes of this. Note : It is a new instrument and it is the first use of it.
@TeledyneTekmar
@TeledyneTekmar 4 жыл бұрын
Dear Mahmoud I am sorry for any inconveniences this may have caused. Please contact Teledyne Tekmar International Support via email at [email protected] and they will happy to help assist you. Thank you, Product Management
@mahmoudmoustafa550
@mahmoudmoustafa550 4 жыл бұрын
Sir, How can I calculate uncertainty determination in TOC fusion
@TeledyneTekmar
@TeledyneTekmar 4 жыл бұрын
@@mahmoudmoustafa550 to calculate this, there are many factors involved. We can not provide enough detail over this message. Please reach out to [email protected] for guidance.
@mahmoudmoustafa550
@mahmoudmoustafa550 4 жыл бұрын
@@TeledyneTekmar Thanks for your cooperation I will do
@manoor6391
@manoor6391 2 жыл бұрын
i am having the same issues , did you get your problem fix ?
@marieanhel9636
@marieanhel9636 5 жыл бұрын
It was very useful! Thanks
@teh_savage_shrimp88
@teh_savage_shrimp88 5 жыл бұрын
Awesome :) Very helpful video!
@tonymorris3378
@tonymorris3378 6 жыл бұрын
One of the only tech videos that I wanted to watch all the way through! Nice!!
@dil4u70
@dil4u70 6 жыл бұрын
please send a link at [email protected]
@dil4u70
@dil4u70 6 жыл бұрын
I need Phoenix 8000 software for windows 7. Can you please add a link for it?
@TeledyneTekmar
@TeledyneTekmar 6 жыл бұрын
Unfortunately due to the age of the Phoenix 8000, the software is not compatible with Windows 7. Please feel free to contact us to see if we can help with a solution on this - [email protected]
@one_hoop
@one_hoop 7 жыл бұрын
I'm fairly certain that the listed guideline of MDL < 5 x spike is not a requirement. The CFR recommends the starting point for the MDL study spikes as 3-5 x the estimated (or desired) MDL, but the first study based on those spike levels frequently fails the requirements that MDL < spike < 10xMDL and the study has to be repeated with adjusted spike levels depending on which direction it failed. The adjusted spike levels may or may not fall in that 3-5x range.
@AtomicElbowDrop
@AtomicElbowDrop 7 жыл бұрын
Thank you for posting stuff like this. Very helpful.
@Chemistry-bq5ud
@Chemistry-bq5ud 7 жыл бұрын
Thank you