Пікірлер
@alexandernarvaez6768
@alexandernarvaez6768 Ай бұрын
thank
@alexandernarvaez6768
@alexandernarvaez6768 Ай бұрын
Thank
@alexandernarvaez6768
@alexandernarvaez6768 Ай бұрын
What is the maximum number of modules you can test?
@emazys
@emazys Ай бұрын
@alexandernarvaez6768 if you multiply the number of PV modules in the string, with the Open Circuit Voltage (Voc) of the individual module, you can find the string voltage. For the Z200 PVA, the maximum string voltage, must not exceed 1000V. Example: 25 modules x 38,95V ≈ 974V. If need to test at high voltage, I recommend to check out the emazys Z300 PVT, which can test at 1500V and 30A.
@yugalkishorelautrey5145
@yugalkishorelautrey5145 8 ай бұрын
Thanks Anders. Quite informative and useful.
@mokdadbenamira4226
@mokdadbenamira4226 2 жыл бұрын
Growatt Inverter : PV isolation low ?!,thank you
@emazys
@emazys 2 жыл бұрын
Please get in contact using the contact for on our website. We will try to assist you in the fault correction.
@aizazrahim8313
@aizazrahim8313 2 жыл бұрын
Nice video
@emazys
@emazys 2 жыл бұрын
Thanks. We appreciate it.
@AnActualCoconut
@AnActualCoconut 2 жыл бұрын
Would this work with RSDs attached to each panel?
@emazys
@emazys 2 жыл бұрын
Please get in touch using the contact form on our website. We can advise on this topic. It is not a straight forward answer.
@adi001fly
@adi001fly 3 жыл бұрын
Z100 tester can test array, when string panels are with Tigo maximizers?
@sergiomolla1027
@sergiomolla1027 3 жыл бұрын
Do you have tester to measure the RISO value for 1500V systems?
@andersrandfromdenmark7749
@andersrandfromdenmark7749 3 жыл бұрын
To be informed on new products from emazys, please sign up to our newsletter: emazys.com/mailing-list/
@nageswararao0227
@nageswararao0227 4 жыл бұрын
In my site +ve dc cable came ground fault more than the -ve dc why
@anubhavaggarwal23
@anubhavaggarwal23 4 жыл бұрын
Does it work with solaredge optimiser?
@andersrandfromdenmark7749
@andersrandfromdenmark7749 3 жыл бұрын
As with all solar panels testers (not only emazys) it is almost impossible to use them with panels that have optimisers build in. So unfortunately the answer is no. You will have to rely on the build in fault finding in solaredge.
@vinyvinycocopuffpassittomenow
@vinyvinycocopuffpassittomenow 2 жыл бұрын
@@andersrandfromdenmark7749 good to know
@AnActualCoconut
@AnActualCoconut 2 жыл бұрын
Isolation menu does it for you..
@dennisnord2093
@dennisnord2093 5 жыл бұрын
How do I find a solar installer with your equipment?
@emazys
@emazys 3 жыл бұрын
Hi Dennis. If you get in contact at emazys.com we can help you.
@alexfisher9080
@alexfisher9080 6 жыл бұрын
Why would I need it in my array? Non of them have ground. Just + and -
@emazys
@emazys 6 жыл бұрын
Hi Alex. Thanks for your question. Solar service and maintenance providers choose our product, to quickly identify and find solar array faults. It is a mobile instrument and as such, it is not installed in the system permanently. If there is a leakage current issue in a floating PV system such as yours, then the PV system is typically grounded during testing. When the whole system is on a common ground, the fault is easily found with the Z100. Grounding kits are often used in these cases. The vast majority of PV installations are however grounded for safety reasons. You may find more detailed information on our website emazys.com/
@VENTUScables
@VENTUScables 8 жыл бұрын
Awesome, please post more videos of actual jobs if possible.