Cla-Val Bobby Explains Pump Control
5:19
Cla-Val Field Service Team
4:49
3 жыл бұрын
Bobby The Valve Guy  L2V Service
2:03
CLAVAL Deep Well Pump Control  Valves
0:57
How PRVs Really Work
4:16
3 жыл бұрын
Válvula de registro WEB Link2Valves
1:47
Administrador WEB de Link2Valves
2:49
Geolocalización WEB de Link2Valves
1:28
Válvula de registro WEB Link2Valves
1:47
Cla Val 90 21 Fire Protection PRV IOM
13:08
Cla Val 90 01 PRV Troubleshooting
13:33
Cla Val 90 01 PRV Start Up
13:38
3 жыл бұрын
Пікірлер
@faresmuradagha3745
@faresmuradagha3745 25 күн бұрын
Hi I am trying to share the engineering information by Arabic can I use this video and add it to my channel with my Arabic translation and explaining and I will add the reference also from your channel?
@faresmuradagha3745
@faresmuradagha3745 25 күн бұрын
Hi I am trying to share the engineering information by Arabic can I use this video and add it to my channel with my Arabic translation and explaining and I will add the reference also from your channel?
@vedangapte1258
@vedangapte1258 2 ай бұрын
Can you explain the operation of pressure reducing valve in detail?
@UnfoldU
@UnfoldU 3 ай бұрын
Can the crd be shut when it leaks
@maxtaxplusdotnet
@maxtaxplusdotnet 3 ай бұрын
🙌
@ugow850
@ugow850 4 ай бұрын
Hi. Is it better to place PRV before or after a solenoid valve?
@Randallsixx13
@Randallsixx13 4 ай бұрын
Very informative. Thank you.
@SuperLusername
@SuperLusername 4 ай бұрын
How does discharge pressure remain 50psi if you change the flow? Doesnt opening the valve more, reduce the resistance pressure on the inflow? And thus the discharge pressure should be higher?
@canlam5697
@canlam5697 4 ай бұрын
Question: if your setting is 50 psi on the discharge side when you close it from flowing, Does the pressure on the discharge side increase or remain at 50 psi.
@user-jx2lu8ru2v
@user-jx2lu8ru2v 4 ай бұрын
Can i throttle relief valve flow rate ?
@piping2024
@piping2024 4 ай бұрын
🙏🙏
@khaiurddinkhan6064
@khaiurddinkhan6064 5 ай бұрын
Nice 👍
@kalathilasokan752
@kalathilasokan752 6 ай бұрын
Thank you🎉
@Hunting334
@Hunting334 6 ай бұрын
👍👍👍👍👍👍👍
@Hunting334
@Hunting334 6 ай бұрын
👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍
@WhosYerFadder
@WhosYerFadder 6 ай бұрын
thanks bobby
@Hunting334
@Hunting334 6 ай бұрын
👍👍👍👍👍👍👍
@willynillynilky5226
@willynillynilky5226 6 ай бұрын
These valves are terrible. Swing checks are more reliable
@cashapp_free_money
@cashapp_free_money 7 ай бұрын
"The only limit to our realization of tomorrow will be our doubts of today." - Franklin D. Roosevelt
@humairasamiya6729
@humairasamiya6729 7 ай бұрын
I want know about crd of banglavartion
@jefffuchs2667
@jefffuchs2667 8 ай бұрын
Some things to keep in mind when installing an inline valve 1) before breaking pipe, run your probe along each side of the pipe into the walls of the trench and ensure you don’t have a coupling close by. 2) throw some jacks under the pipe on each side. This will ensure your pipe doesn’t sag and pull out of the coupling 3) To minimize using short pup pieces of pipe and multiple leak points - Use and FCA on one and and change your valve off that then a longer stick of pipe and 1 coupling for the other side 4) Always, always, always grease and wax tap your valve and couplings - this will preserve the assembly and bolts and make it easy for the next guy who has to dig it up and repair it in 30-40 years
@sulemanabdullah4009
@sulemanabdullah4009 9 ай бұрын
lovely thank u so much.
@a.m347
@a.m347 9 ай бұрын
6:24 is wrong Because when the valve open it will not allow the flow from downstream to the main valve It is one direction flow from the main valve to downstream so the correct it will allow the flow in the top chamber to be evacuated through the pilot to downstream not vice versa
@sangrambarla8587
@sangrambarla8587 9 ай бұрын
I'm from Scholar academy 🥳
@a.m347
@a.m347 9 ай бұрын
No more valuable explanation like that 😍😍❤️🙏
@wat3rdog25
@wat3rdog25 9 ай бұрын
Current app ask for parent organization. The drop down has no option other than select. Unable to save new site.
@jahangirkabir574
@jahangirkabir574 10 ай бұрын
Nice presentation
@mradulsaraswat08
@mradulsaraswat08 11 ай бұрын
Good day Claval team We are having a very rough experience in getting quotation from your UAE representatives. From past 14 days we are chasing them and till today the quote has not been provided. And that being the case after we gave them the model number and specifications. If they had to choose it, I wonder how long it would have been delayed. No doubts, your valves might be good but the supporting staff is not that great to be honest.
@a.m347
@a.m347 Жыл бұрын
The working principle for this station is the same for the fire protection jokey and Electric pumps which are connected in parallel if there's small pressure drop in the system due to leakage the pressure will be drop until it reaches the setting point of jokey pump so it will comes to service If the pressure dropped more due to sprinklers operation or hose cabinet the pressure will be reduced more until reaching the setting point of the electric pump it will come also to service to fulfill the demand of higher flow and so on. So by this configuration we keeping the larger PRV from continuous operation to protect it from cavitation for long life operation. Also this station may be working alternatively during maintenance works in one side branch keeping the other working delivering water to the system.
@coreysullivan7401
@coreysullivan7401 Жыл бұрын
What does CLR STAND FOR?
@paulgibson2591
@paulgibson2591 Жыл бұрын
Magic
@msalazar89
@msalazar89 Жыл бұрын
Make a video for the cds 7 with the delay feature please
@ttt8878
@ttt8878 Жыл бұрын
Thanks 👍🏿
@nourel-moubarekel-tayeb8215
@nourel-moubarekel-tayeb8215 Жыл бұрын
Hi is a pressure relief valve considerate as a CRL ?
@jmoe724
@jmoe724 Жыл бұрын
Do you have a video that explain the smaller tubes that tie into the pilot assembly .
@kremesti
@kremesti Жыл бұрын
fantastic video thank u
@kremesti
@kremesti Жыл бұрын
This is amazing
@kremesti
@kremesti Жыл бұрын
what is CRL????
@yanarifin9343
@yanarifin9343 Жыл бұрын
Support membran sir?
@mdarifwaquar3270
@mdarifwaquar3270 Жыл бұрын
Very nice 👍🏻 sir
@ranger7915
@ranger7915 Жыл бұрын
Please make video on this float level control and maintenance
@ranger7915
@ranger7915 Жыл бұрын
Ur service available at united Arab Emirates?
@c.nobody3378
@c.nobody3378 Жыл бұрын
Big foot print on the system.. also looks annoying to work on in the field.
@hanruobing6924
@hanruobing6924 Жыл бұрын
We are manufacturer specialized in auto and marine diesel engine parts since 1952. Our main parts are EURO II system: plunger, nozzle , delivery valves, head rotors, repair kits, etc. Common rail system: Injector complete and injector spare parts for CATERPILLAR, DENSO, DELPHI , BOSCH, SIMENS, CUMMINS, etc. If you have any inquiries, pls do not hesitate to contact me
@atulsharma2325
@atulsharma2325 2 ай бұрын
​@@hanruobing6924where to contact u
@malikosmanahmed110
@malikosmanahmed110 Жыл бұрын
Please I need to know how to adjust Deluge valve CLA-VAL 134E-O5
@samirsebai8463
@samirsebai8463 Жыл бұрын
Thanks for your video
@maiconmartins1910
@maiconmartins1910 Жыл бұрын
Tem em português
@hectorpadrongarcia8608
@hectorpadrongarcia8608 Жыл бұрын
Sería genial oírlo en español, saludos!
@hectorpadrongarcia8608
@hectorpadrongarcia8608 Жыл бұрын
Seria genial oírlo en español, saludos!
@simplevideos9965
@simplevideos9965 Жыл бұрын
Good 👍😊
@mustafaemirhankuru8422
@mustafaemirhankuru8422 Жыл бұрын
That was a good tutorial thank you