Sir what about 0 Point and 1 point formula? 😮😢Please help me
@Neets..6 күн бұрын
How toh find wi
@NUNUZ079 күн бұрын
Thank you very much clearly explained
@VinodKumar-cc5ir11 күн бұрын
Sir can you make in hindi language
@hikikomorihachiman749117 күн бұрын
Thank you 🤩🤩🤩
@manikantalade955519 күн бұрын
Thank you sir..... My doubts are cleared❤
@zhlmrsh.551620 күн бұрын
In the fan efficiency formula, what Q are you referring to?
@KeshavJadhav20 күн бұрын
@@zhlmrsh.5516 It is volume flow rate of air
@comp124322 күн бұрын
Amazing really
@simransingh-n9h22 күн бұрын
sir isme v3 kese nikala pleace anser sir
@KeshavJadhav22 күн бұрын
@@simransingh-n9h Please refer this video in which calculation of v3is explained: kzbin.info/www/bejne/p5iTgpSvZ856eJYsi=gQoKVI-xP_yPiHh2
@simransingh-n9h22 күн бұрын
@KeshavJadhav sir refer video me 20% fresh air and 80% recirculated air hai jiski wajah se v3 nikla
@simransingh-n9h22 күн бұрын
Refer video me aap pehle h3 nikala baad me sp.volume.nikala
@simransingh-n9h22 күн бұрын
Isme v3 (sp.vol.) pehle nikala
@sayanbhowmick920323 күн бұрын
Very well explained
@TeamRecreation200323 күн бұрын
A commercial shop has following loads: Room sensible heat: 58.15 kW Room latent heat: 14.54 kW The summer outside and inside design conditions are: Outside: 40oC DBT, 27oC WBT Inside 25oC DBT, 50%RH 70 m3 /min of ventilation air is used. Determine the following if the by-pass factor of the cooling coil is 0.15. (i) Ventilation load (ii) Grand total heat (iii) Grand sensible heat factor (iv) Effective room sensible heat factor (v) Apparatus dew point
A conference room for sitting 100 persons is to be maintained at 22 oC DBT and 60% relative humidity. The outdoor conditions are 40 oC DBT and 27 oC WBT. The various loads in the auditorium are as follows: Sensible and latent heat loads per person 80 W and 50 W respectively; lights and fans, 15000 W; sensible heat gain through glass ceiling etc. 15000 W. The air infiltration is 20 m³/min and fresh air supply is 100 m³/min. Two-third of recirculated room air and one-third of fresh air are mixed before entering the cooling coil. The bypass factor of the coil is 0.1. Determine i) Apparatus dew point, ii) Grand total heat load and iii) Effective room sensible heat factor
Can you please make a video on this numerical as soon as possible? "Atmospheric air at 30°C dew point temperature and 75% relative humidity, enters a cooling coil at a rate of 200 m³/min. The coil dew point temperature is 14°C and the by-pass factor of the coil is 0.1. Determine:[10] i) The temperature of air leaving the cooling coil; ii) The capacity of the cooling coil in TR and in KW. iii) The amount of water vapor removed per minute; iv) The sensible heat factor for the process"
During stage 3, is it okay for the possible combinations to be in a different order?
@KeshavJadhav3 ай бұрын
@@kemberlyxavier8400 Yes, maximum profit should be same
@WonYYang3 ай бұрын
kzbin.info/www/bejne/sJSni55npdasqMU
@DeeptiKhatri-ki4xk3 ай бұрын
Thank you sir
@jowlenejones4 ай бұрын
Thank you so so much!!!!!!!!! You have no idea how this helped me!
@eduardosiliceo89994 ай бұрын
I loved this video, thanks for sharing!!
@LazarosLazaros-p3g4 ай бұрын
In many books, there is zj -cj . Is it a problem?
@KeshavJadhav4 ай бұрын
@@LazarosLazaros-p3g That is also correct, in that case instead of +ve maximum value(Cj-Zj), we need to choose -ve value (Zj-Cj).
@chandramatalukdar78835 ай бұрын
Thank you Sir
@CaspreMUSIC5 ай бұрын
in the 1st 3 point problem, my answer is 200.8448 not 200.4014
@Master-nu4yg5 ай бұрын
Why is 0 state considered?
@KeshavJadhav5 ай бұрын
@@Master-nu4yg because there can be zero allocation for one of the store.
@poojapushpa86895 ай бұрын
I am video editor if you want to higher me comment
@mrbalaji78795 ай бұрын
Sir can u send this in pdf format
@herodmoonga47996 ай бұрын
Only you, else I never understood simplex method, you have saved me
@ashupatharut96647 ай бұрын
Thnq u
@AbhinavDhakpade7 ай бұрын
Best explanation 😊
@Lucifer-rj8rm7 ай бұрын
Thank you so much for the detailed explanation , sir!
@nihas82807 ай бұрын
Thnx btw didnt understand anything
@KeshavJadhav7 ай бұрын
Thanks for your comment 🙏😀
@abhinandanjain52807 ай бұрын
Great video
@SamiUllah-og7tr7 ай бұрын
Best effort
@Newton608 ай бұрын
Great Explanation....
@sharafadathodi8 ай бұрын
Hello Sir, Thanks, and Nice video Can I have your number please I need to start tube drawing process and I wanted to know the tools for inner ID Drawing