Hi, Thank you for the question! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@ILmaddogАй бұрын
Hi. In our company we got network build with many Moxa switches with Turbo RIng v2 enable. But we have a problem with our network. The "Master" is not set manually but is selected automatically. Therefore, the "Master" sets itself on the switch with the lowest MAC address, which is correct. The problem is that the link is not set to blocked on the switch that is the master, but on a completely different switch. So the entire network is not in a healthy status, just a broken one. Do you have any ideas why this is happening?
@moxaincАй бұрын
Hi, thanks for reaching out. Our Technical Support Engineers can help! Please submit a ticket on our website and they will be in touch. www.moxa.com/en/support/technical-support
@angelicamaeresurreccion1900Ай бұрын
How many power meters (supposed there are 100 modbus RTU) can I connect to a single moxa (example Nport 5100 series)
@moxaincАй бұрын
Thank you for the question! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@birdost48722 ай бұрын
i like moxa
@namitdewan41512 ай бұрын
How to delete TB fault?
@moxainc2 ай бұрын
Hi @namitdewan4151, thanks for reaching out. Your questions can be answered by our Technical Services team. Please create a support ticket on our website and a representative will be in touch. www.moxa.com/en/support/technical-support
@eduingeniero3 ай бұрын
Where can I get those certificate?
@moxainc2 ай бұрын
Thank you for the question! If you have any questions about our products or services, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@LUGUIM44 ай бұрын
great video
@mynp4 ай бұрын
My only suggestion is that you should use the different cable colors for the different lan segment
@ggarza784 ай бұрын
How many Modbus RTU nodes (slave address) can I connect to one port to then convert them to Bacnet? I want to communicate several Variable Frequency Drives.
@moxainc4 ай бұрын
Thank you for the question! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@WHAJONNALAGADDAHEMASREE6 ай бұрын
Great!
@setiawanadi43887 ай бұрын
In your example, you are using PT-G7728 for PRP Ring A, My question, can we use PT-7728 instead PT-G7728. how is the PTP complience on those 2 type switch. are both type are PTP complience switch.?. Thanks in advance for your respond
@moxainc7 ай бұрын
Hi @setiawanadi4388, thanks for reaching out. Only PT-7728-PTP models within the PT-7728 range support PRP/HSR when equipped with PM-7200-4GTX-PHR-PTP or PM-7200-4GSFP-PHR-PTP modules, and both PT-7728-PTP and PT-G7728 support IEEE 1588 hardware-based PTP.
@pohahchin7 ай бұрын
Hi, just to enquiry my workplace having power shutdown on the complex after power resumed and turned ON, the MOXA switch unable to connect to devices, no error indication, power led is lit up and ports lit up when insert network cable but blinking not consistent, any advice on this? After replacing new one all back to normal, anyway, to check on the faulty set?
@moxainc7 ай бұрын
Thank you for the question! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@amoreforless7 ай бұрын
Cool that they are using lots of cameras to monitor what's going on.
@amoreforless7 ай бұрын
One of the best explanatory videos I've seen so far, great attention to detail, and indepth discovery rather than, a jazzy short clip. Very tidy engineering.
@Simguitar9 ай бұрын
Where I can find/download that MokaLANBreakTester tool?
@moxainc9 ай бұрын
Hi @Simguitar , thanks for reaching out. The Moxa Lan Break Tester tool is an internal testing tool, unfortunately, it is not available to the public. You may want to consider using any fast ping tool that has resolution of 1ms to measure recovery time. Alternatively, feel free to reach out to your local Moxa representatives for assistance with testing. If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@cmms123410 ай бұрын
Excellent crispy details
@stringsandhamers10 ай бұрын
Why a non-hsr device must use a redbox? Why it cant be connected to a hrs switch (like the others non hsr devices)?
@moxainc9 ай бұрын
Hi @stringsandhamers, thanks for reaching out. Standard Ethernet devices can’t be connected directly to HSR ring because HSR modifies the frame and it can’t be processed correctly by a non-HSR node. To connect Singly Attached Nodes to HSR ring a Rebox or HSR switch should be used. HSR switch is essentially a combination of a switch and Redbox in a single unit, so from IEC standard point of view HSR switch is a multiport Rebox. The terms Redbox and HSR switch sometimes could be used interchangeably. If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@0097150413315810 ай бұрын
sys 600 scada
@zubairshahzad489510 ай бұрын
Moxa Industrial Ethernet Switch EDS-P506E-4PoE-2GTXSFP-T how i can connect as api
@moxainc10 ай бұрын
Thank you for the question! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@zubairshahzad489510 ай бұрын
can share you detail here @@moxainc
@zubairshahzad489510 ай бұрын
Moxa Industrial Ethernet Switch EDS-P506E-4PoE- is there any api for automation
@zubairshahzad489510 ай бұрын
is there any moxa web api for EtherDevices EDS- 518E series ????
@halzoock345310 ай бұрын
only question is you didn't show how you came up with the address in the Scada software to set the speed. How did PIW 256 relate to the mapped address?
@ThEzXiON Жыл бұрын
It’s possible without postman?
@moxainc Жыл бұрын
Thank you for the question! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@gregorybyrne2453 Жыл бұрын
Very interesting some great outside the tunnel box there. I still say compaction compression of the soil at least in soft rock boring would be the fastest as it eliminates extraction & potentially creates it's own liner. "All shall seek shelter under rocks or in caves." In this the millennium of climate change END TIMES due to the mystery of the 7 star crossings Jesus held in his hand. 2033-40-3033
@millerocampo7110 Жыл бұрын
Como se puede dar reset a fabrica de un EDS-405a si no tiene dicho boton?
@moxainc Жыл бұрын
Hi @millerocampo7110, thanks for reaching out. You would need to use the serial console cable to reset the unit back to factory default. Or use a MIB browser and MIB file. For more Moxa product information, you can visit our website www.moxa.com/en/.
@thelightofislam2192 Жыл бұрын
Dear sir, Good day to you. We have tried to configure (MOXA-UC-8410) switch (fix the serial setting RS-485 2W) by linux command but can't save the program.However, provided Moxa switch serial number is TAIDB1080450.In addition we can't browse IP by browser like existing one.Thanks for your support. Regards Md Siddikur Rahman Ripon On behalf of Lt Cdr Lutfor
@clasesutnfrc8699 Жыл бұрын
Music is too loud
@fatonaoladimeji9697 Жыл бұрын
Does this device support MQTT SparkplugB or just plain MQTT?
@moxainc Жыл бұрын
Hi, thanks for reaching out. Unfortunately, the AIG-101 supports generic MQTT and does not support MQTT SparkplugB.
@cmms1234 Жыл бұрын
Systematic explained without typical security jargons, thank u
@FernandoHernandez-ux2dc Жыл бұрын
Great video! Where can I download the MCC tool?
@shashanksd7082 Жыл бұрын
Hi, How does the Device address(101404) gets assigned, can you please tell me....
@moxainc Жыл бұрын
Hi, thanks for reaching out. Our Technical Support Engineers can help! Please submit a ticket on our website and they will be in touch. www.moxa.com/en/support/technical-support
@ghilcacho5617 Жыл бұрын
Am I right to assume, If I have two slave Modbus device running on RTU and one running using TCP and I can't access them both at the same time from same MGate ? I need 2 MGATE?
@moxainc Жыл бұрын
Unfortunately, for the protocol conversion to Modbus you must choose Modbus RTU OR Modbus TCP since it is not capable of doing both at the exact same time. You would need to use two MGate 5217’s in order to convert from BACnet to Modbus RTU and BACnet to Modbus TCP. If you have additional questions, please use this contact form and a Moxa representative will be happy to provide further assistance. www.moxa.com/en/contact-us/contact-form
@angelhur Жыл бұрын
What is the procedure to factory reset these devices? I have some in the office and we don't know the administrator password, since the systems technician left. moxa 405A
@moxainc Жыл бұрын
Hi @angelhur, thanks for reaching out. Your questions can be answered by our Technical Services team. Please create a support ticket on our website and a representative will be in touch. www.moxa.com/en/support/technical-support
@bambangwfa-ic3ov Жыл бұрын
GEBYAR MERDEKA
@AdamTozian Жыл бұрын
Can An existing Modbus Points list be added instead instead of adding each Modbus point individually? Would It need to be in a specific CSV format?
@moxainc Жыл бұрын
The MGate 5217 provides Modbus Configuration Import/Export feature. On a large scale, you may connect lots of Modbus devices, which have to configure lots of Modbus commands to get data. The MGate provides the Master Configuration Import/Export feature, which helps you easily edit massive Modbus commands through Excel to save configuration time. To get the template, just click Export to download the comma-separated values (CSV) file on your computer. If you have additional questions, please use this contact form and a Moxa representative will be happy to provide further assistance. www.moxa.com/en/contact-us/contact-form
@lammangcongnghiep Жыл бұрын
That's so great, millisecond-level (<50ms) is suitable for most of PLC/IO remote at factory, thank you for professional test 🤩
@emileebengue9008 Жыл бұрын
Hello Please, which software are you using to configure EDS 316 and which communication cable are you using? I'm unable to configure mine, It's new.
@moxainc Жыл бұрын
Hi Emile - thanks for reaching out. Your questions can be answered by our Technical Services team. Please create a support ticket on our website and a representative will be in touch. www.moxa.com/en/support/technical-support
@sonlinhtv Жыл бұрын
can write value from SCADA to VFD?
@moxainc Жыл бұрын
The MGate MB3180 is a transparent gateway, it will convert any data (read or write) between Modbus RTU or Modbus ASCII and Modbus TCP.
@altamushanwarkhan538 Жыл бұрын
Thanks for this video. May you tell me where can I download EDS file for NPort 5100 Series?
@moxainc Жыл бұрын
The NPort 5100 datasheet can be downloaded on our product page: www.moxa.com/en/products/industrial-edge-connectivity/serial-device-servers/general-device-servers/nport-5100-series#resources
@lyaeusv3828 Жыл бұрын
it's very clear ! this dude under me is a loser prolly a ccna freshman
@anibrubilar Жыл бұрын
hi, You will have some video with a MOXA IEX-402-series-vdsl2 backup. Would be a great help.
@moxainc Жыл бұрын
Thank you for the suggestion! If you have any questions about our products, feel free to contact a Moxa representative by completing the online form: www.moxa.com/en/contact-us
@vanhelsing32252 жыл бұрын
good product... thanks for the briefing
@edmundomelomartinez93292 жыл бұрын
how do i choose the "read starting address"?
@moxainc2 жыл бұрын
Please refer to the Modbus address map that should be provided by your Modbus slave's manufacturer
@ramadhanianurpuspito97372 жыл бұрын
Nice
@MarioATEFPV2 жыл бұрын
Hi, it's a protocol converter for "one" Modbus Slave device? or can i have access to more of one slave on a Modbus line with more Items. thanks
@moxainc2 жыл бұрын
The MGate 5103 Supports RS-485 2-wire serial interface. With RS-485 2-wire, you can have up to 31 Modbus RTU serial slave devices connected on the same bus. Furthermore, you can configure the MGate 5103 to send up to 128 different Modbus commands to those serial Modbus Slave Devices.
@MarioATEFPV2 жыл бұрын
@@moxainc thanks…so it’s a gateway..right?
@moxainc2 жыл бұрын
@@MarioATEFPV Yes, a Gateway for sharing data between two different Industrial communication protocols. A Moxa solution provider can discuss your application and the MGate 5103 as a solution in more detail. Please visit this page to find a local distributor: www.moxa.com/en/how-to-buy/find-a-distributor
@edwardk32 жыл бұрын
Not clear. Acronyms everywhere. Sucks
@nick_79792 жыл бұрын
When will MOXA have more detailed videos that are longer than 2 minutes?
@davanuvfanda34902 жыл бұрын
Omg its from book in school
@Daniel-yt6ls2 жыл бұрын
Hello. I would like to convert the data from Modbus TCP/IP to IEC 104 with a Moxa MGate 5114. Could I find some help somewhere?
@moxainc2 жыл бұрын
Our Technical Support Engineers can help! Please submit a ticket on our website and they will be in touch. www.moxa.com/en/support/technical-support