hello i want to tile a face brick wall which was painted with varnish, how to i go about tiling it
@GraemeSchlumpfАй бұрын
With the under and over waterproofing, aren't you stopping the puddle flange from doing its job if the top membrane is compromised, the moisture will be locked in.
@tekcreations745Ай бұрын
could this be injected to fix drummy tiles?
@davidanderton24373 ай бұрын
What floor sheet is that?
@kelvinli96643 ай бұрын
Is there any difference between CA20P & CA20P Plus? Most of the shops out there only sell CA20P. Is CA20P still fit for this purpose?
@cryptodojoau54254 ай бұрын
How do we get hold of one?
@ardexaustralia4 ай бұрын
Simply register via this link: linkstre.am/ardexhasyourback
@TheSBoy34 ай бұрын
I'm also interested in where the placement for the shower screen would be. Is this meant to be an enclosed shower, where the screen would sit on top of the waterstop?
@DaneHoffner2 ай бұрын
Me to, how does the screen sit 🤔
@KumarK-q8o5 ай бұрын
Too bad, I saw this video after applying SLC on top of liquid DPM and they both reacted and the DPM burst at a few places and came out of SLC layer. The SLC should be dry overnight, but it has been 4 days and the rest of the floor is still little damp at some spots. Any advice, please?
@Bbbbbbbbbbb-f1w5 ай бұрын
Today I was painting and my roller had some dried up Redgard waterproofing on it and I peeled it off and stretched it. As a bathroom contractor, I’m glad I always have used Redgard.
@TheSBoy35 ай бұрын
How do you know what size wood to use as a former for the drain base? Do you go a bit bigger than the drains' actual size to allow for shrinkage of the screed, or is it exactly the same size?
@ardexaustralia4 ай бұрын
Ideally if you have the drain system handy this is better to use as a forming guide. If using the actual drain, this should be washed down after removal from the fresh screed installation. Regardless of whether you are using the actual drain or a plank of wood for sizing, it is best to allow for a little extra room. It is much easier to fill voids and lay tiles over the filled voids than having issues with insufficient space (especially once waterproofing is already installed. Generally 10mm extra allowance is all that you should need.
@KizWhalifa.5 ай бұрын
You didn’t even explain how to square the waste heights of the pads or anything educational, you essentially just filmed yourself working
@ardexaustralia4 ай бұрын
The placement should be measured from the surrounding walls to make things square. Unfortunately we do not go into detail with all aspects of the installation but we appreciate the feedback on what you feel is lacking for our next videos.
@MrJarrodGIll7 ай бұрын
is there an alternative to using the STA tape for the strip drain? such as Ardex deck webbing?
@ardexaustralia7 ай бұрын
Great question @mrjarrodGill - There is no alternative method to the ARDEX STA/STB system. ARDEX Deckweb would not be a suitable substitute sorry!
@MrJarrodGIll7 ай бұрын
@@ardexaustralia thanks for the answer , what happens if a small section of screed has broken off near the strip drain, what would be the best way to repair? or can the Sta bond breaker cover over that section before waterproofing?
@kiranvenky7 ай бұрын
Application area
@ardexaustralia7 ай бұрын
Do you have a question @kiranvenky - happy to help
@marvinmartin46927 ай бұрын
After 50years in the trade, this has got to be one of the worst epoxy grout’s I’ve ever used!
@ardexaustralia7 ай бұрын
It is disappointing to hear you are dissatisfied with the performance of the grout @marvinmartin4692 . Could you offer suggestions as to how you believe it could be improved?
@poden38637 ай бұрын
I have a similar bathroom to do. My longest fall from wall to strip drain is 1200mm. My fall should be 10mm of fall. This means there will be 10mm of your stop angle exposed inside the shower at the top of the strip drain , how do you finish the edge between tile and stop angle ? Silicon or grout? In your case it should be about 6mm fall.
@ardexaustralia7 ай бұрын
Good question @podden3863 - The minimum thickness of a bonded screed is 15mm. This means the height of the screed at 1.2m will be 30mm to achieve the 1/80 falls for shower areas. ARDEX do not sell the stop angles.
@towncountryceramictiling80053 ай бұрын
@@ardexaustralia to answer that question it would be to use a box angle trim that is used for external joints, fit this over the top of the water stop, then screed this in as per normal, once the floor is then tiled you have a nice clean edge on the inside and a flush floor tile to the outside of shower, this is level so the shower screen sits on top, that is how I do it and it is a very clean look without compromising the waterproofing
@towncountryceramictiling80053 ай бұрын
Use a box trim that is used on external corners, sit that on top of the water stop, then you end up with a clean edges and a level flat surface for shower screen
@marvinmartin46927 ай бұрын
Easy to use my ass! It’s as stiff as Ice cold asphalt patch! After almost 50years in the trade this is something I will never use again! Never!
@ardexaustralia7 ай бұрын
OK @marvinmartin4692 - ARDEX WA and ARDEX WA100 epoxy tile adhesives are more difficult to apply and are ‘stickier’ than cement-based tile adhesives. Your comments will be passed on to our Marketing Department.
@digita1hero7 ай бұрын
What's the small plinth around the edges - I'm doing a fixed panel screen, do I need that?
@ardexaustralia7 ай бұрын
Good question @digita1hero - We believe you are referencing the waterstop angle that is protruding up around the sides of the demonstration unit being waterproofed. This is intended to prevent passage of water from within the shower enclosure to the surrounding areas (including potential water travelling through the tile adhesive /screed). We have a number of visual resources that may assist in understanding the waterproofing detailing processes, including the link below showing how to incorporate a shower screen installation: www.ardexaustralia.com/pdf/cad/D23%20-%20SHOWER%20WATER%20STOP%20AND%20COVER%20ANGLE.pdf?_gl=1*bsh86z*_ga*MjAwMjc3MDM0NS4xNTkyMzQ4NDQ4*_ga_5BRGGQSHFH*MTcxNTIyNjQwMC4xMjgxLjEuMTcxNTIyNjQwMC42MC4wLjA.
@SLim-nw9wc8 ай бұрын
Please do a video of the next step and what goes next onto the waterproof membrane. There is very little of this information being covered.
@ardexaustralia7 ай бұрын
Glad you asked @SLim-nw9wc ! kzbin.info/www/bejne/oqnSqYufmd11rpI
@Paytrade9 ай бұрын
Hi Ardex, will the STB tape adhere to polyurethane already applied? We have used a universal tile-over shower tray and have poly where the villa board meets the tray as per the installation guidelines. By the way thanks for the great technical sheet on the Universal Shower Trays!
@ardexaustralia7 ай бұрын
If the polyurethane is a paintable one then the STB would stick to it. The concern here is whether or not the polyurethane exhibits plasticiser migration. This is the act of plasticisers within the polyurethane slowly drifting out of the polyurethane throughout the life of the sealant. This can lead to softening of membrane coatings applied on top of the sealant. STB tape will help protect the membrane from directly touching the polyurethane. You're welcome re: the technical datasheets!!
@geoffstein38969 ай бұрын
Does the direction of the glue for the wall tiles need to be running vertically so that the water will run between the channels? Thanks
@ardexaustralia7 ай бұрын
Good question @geoffstein3896 - The main thing here is ensuring you are keeping the notches unidirectional. If you fan the adhesive or alter directions there is a greater chance you cannot collapse the notch voids properly and end up with voids. No specific requirement for this one but it is preferable to choose the best direction which will allow proper Tarver method notch collapsing.
@winniliss2 ай бұрын
@@ardexaustralia It should be in a verticle motion to allow any water trapped behind the tile to run down to the puddle flange instead of running (wicking) horizontal.
@BB-pf2cs10 ай бұрын
That roller cuts without the need for a brush! How amazing.
@ravinvijayakumare10 ай бұрын
How do yo mix the slurry?
@ardexaustralia7 ай бұрын
Good question @ravinvijayakumare - Bonded screeds are generally applied with a bonding slurry coat consisting of a liquid polymer additive (e.g. acrylic or SBR - rubber latex such as ARDEX Abalastic or WPM405) mixed with cement. The bonding slurry is broomed thoroughly over the dry membrane and the mixed wet screed mortar applied over the still wet bonding slurry. The liquid polymer additive is also diluted with water and mixed into the screed mortar.
@Jamie-k3c11 ай бұрын
What about the Vertical water stop angle as per the new AS
@ardexaustralia7 ай бұрын
Good question @user-fh7ne1ls2u - I’m sorry but I’m not sure which part of the waterstop requirements you are enquiring about. Perhaps the link below will visually demonstrate the use of a waterstop in a shower recess: www.ardexaustralia.com/pdf/cad/D23%20-%20SHOWER%20WATER%20STOP%20AND%20COVER%20ANGLE.pdf?_gl=1*bsh86z*_ga*MjAwMjc3MDM0NS4xNTkyMzQ4NDQ4*_ga_5BRGGQSHFH*MTcxNTIyNjQwMC4xMjgxLjEuMTcxNTIyNjQwMC42MC4wLjA
@brendonglennie684311 ай бұрын
How flexible is EG 15 epoxy grout? Is it suitable for a shower floor built on a timber sub-floor (house on stumps that would most likely have more flex on joists etc)
@ardexaustralia7 ай бұрын
Good question @brendonglennie6843 - ARDEX EG-15 epoxy grout is more flexible than the ARDEX cement-based grouts even if ARDEXZ Grout Booster is incorporated.
@donnastein494611 ай бұрын
Why did you waterproof below the screed and above, that isn't a requirement is it?
@ardexaustralia7 ай бұрын
Good question @donnastein4946 - No this is not a requirement. Just for demonstration purposes. To be compliant with the Australian Standards, the active membrane must be applied to a substrate with falls to wastes.
@thomasmorris9318 Жыл бұрын
Hi, Can this product be used to waterproof an area of salt water chlorinated pool that has a slow leak? Will be applied over existing concrete which needs sealing.
@ardexaustralia7 ай бұрын
Good question @thomasmorris9318 - ARDEX WPM300 is a moisture barrier/primer and on its own cannot be relied upon to address leakage issues. The leaking area needs to be located and repaired with a repair mortar such as ARDEX A46.
@ardexaustralia Жыл бұрын
Check it out here: ardexaustralia.com/product/ardex-stb-tape/
@AK-ky3ou Жыл бұрын
What does this product do?
@ardexaustralia Жыл бұрын
Please visit the product page on our website for more information! ardexaustralia.com/product/ardex-stb-tape/
@marktracey4018 Жыл бұрын
Angles under the new rules says it is ment to be stainless steel 😂and that sealant won't stick to well to that puddle flange, should of primed it first. You might want to do a thicker bead against the wall where the angle meets.
@ardexaustralia Жыл бұрын
The sealant is fine to use in this situation and priming was not necessary. No harm in doing it, but this application doesn’t require it.
@conp2471 Жыл бұрын
Does is have to be the CA20P Plus for the drain or CA20P is good enough ? Thanks
@ardexaustralia Жыл бұрын
CA20P and CA20P are interchangeable in this scenario. Both the older CA20P and the newer CA20P Plus would both be suitable for this application.
@nessnorimi9896 Жыл бұрын
This fellow has an impressive set of skills- I love watching people who are masters of their craft! That waterstop on the floor is 5mm proud of the floor, as per AS3740 details for unenclosed showers (incase anyone asks!) Thanks so much for producing this set of videos- I found them extremely helpful.
@ardexaustralia Жыл бұрын
Thank you very much!
@mickthompson3342 Жыл бұрын
When is the waterproofing done ????
@melvinp2798 Жыл бұрын
😕 P r o m o S M
@sepehrvakili2121 Жыл бұрын
If bond-breaker tape is utilized, it eliminates the necessity of applying a flexible sealant or fillet??
@ardexaustralia Жыл бұрын
Yes, where the bond breaker tape is applied, the need for a sealant is eliminated. This will be a substitution for the traditional sealant to act as the system’s bondbreaker. Thank you for the question and for watching.
@jonoc4865 Жыл бұрын
AS 3740 allows for the use of proprietary transition tapes in place of a bond breaker. STB tape falls into this category.
@vannguyen3251 Жыл бұрын
Thanks
@stefanomarando2180 Жыл бұрын
Your guy did a great job, but how do you explain to the client that the water-stop will be visible and covered with wp membrane? In addition, wouldn’t be better to fill the gap between the shower base tiles and the wall with silicone or polyurethane instead of cementitious grout? Thanks for these videos
@ardexaustralia Жыл бұрын
Glad you like them! The waterstop will generally be covered with the installation of the shower screen or an alternate material. The video does not reach this step of the installation. As for the junction, the use of silicone will allow for a greater mount of movement but this is not necessary. Application of grout in this area is suitable, albeit, if the installation encounters high movement cracks could develop in the more rigid cementitious grout.
@conp2471 Жыл бұрын
Nice video, how would you finish the waterproofing above the screed into the drain ?
@ardexaustralia Жыл бұрын
Thanks for your question! What additional info do you need other than the finish shown over the drain in the video? Happy to help!
@conp2471 Жыл бұрын
@@ardexaustralia If you were to screed above the waterproofing and then waterproof again would you have to use another puddle flange? Trying to avoid creating a wet sandwich type situation if the 1st membrane fails
@hungnguyenquoc9487 Жыл бұрын
@conp I used a puddle flange from bunnings. Waterproof the tile underlay and the puddle flange. I then use a piddle flange adaptor (also sold by bunnings) and screed around it. This adaptor acts as a second puddle flange. I then incorporate the waterproofing into that adaptor.
@IB6-UB911 ай бұрын
What is the slurry made of? Just a very wet screed?
@gavstar101Ай бұрын
Yeah it doesn't say. The specs say neat cement/water mix but others slurry the produst mix@IB6-UB9
@hearliam Жыл бұрын
Can the bond breaker tape go onto self levelling concrete substrate? great video.
@ardexaustralia Жыл бұрын
Yes the ARDEX STB and STA tape can be used onto a self levelling substrate as long as this is primed first using the ARDEX Multiprime. Like all recommendations before priming you must ensure the substate is clean of all contaminations, including dirts, dust, paint etc. Once cleaned, the ARDEX Multiprime is applied. This is allowed to cure for 30 mins to 1 hour then the ARDEX STB and STA tape can be installed.
@brightbubblez5256 Жыл бұрын
A new rule for a water stop angle to run up the wall 600mm, when the shower glass is close to a doorway.
@moussabarakat926 Жыл бұрын
HOHOHOHOHOOOO... THERES LOTS OF STEPS MISSING IN THIS VIDEOS! PLZ SHOW EVERY STEP WHEN APPLYING AND CLEANING. SO TRADIE SEE HOW HARD IT IS THIS SHIT
@moussabarakat926 Жыл бұрын
HOHOHOHOHOOOO... THERES LOTS OF STEPS MISSING IN THIS VIDEOS! PLZ SHOW EVERY STEP WHEN APPLYING AND CLEANING. SO TRADIE SEE HOW HARD IT IS THIS SHIT
@ardexaustralia Жыл бұрын
We really appreciate your feedback! We're onto it! Thank you for watching
@38flatBauble Жыл бұрын
I think your video is too long, try to be more succinct in your video and avoid any superfluous information. Other than that great editing and I for one stand with beer.
@ardexaustralia Жыл бұрын
Thank you so much for the feedback! We really appreciate your viewing and commenting.
@NickNorthcuttАй бұрын
Its 46 seconds. Stop bitching
@kerthunder Жыл бұрын
Can i waterproof my concrete pond with this product?
@ardexaustralia Жыл бұрын
ARDEX WPM300 can be used in a concrete pond, yes. Thank you for watching!
@ardexaustralia Жыл бұрын
Good question @bazza - We used a 40mm water stop angle. As this size suited the needs of our project. There are other sizes available so please assess the individual needs of your bathroom renovation.
@bazza219 Жыл бұрын
What size is the water stop angle?
@joe1801 Жыл бұрын
looks about 75mm
@ardexaustralia Жыл бұрын
We used a 40mm water stop angle. As this size suited the needs of our project. There are other sizes available so please assess the individual needs of your bathroom renovation. Thank you for your question!
@andrewrwhite71 Жыл бұрын
If it drys patchy, what are the best ways to fix it?
@ardexaustralia Жыл бұрын
There are many possible reasons, and all are related to the drying of the grout and the underlying tile adhesive. This can be affected by the porosity of the tiles, the temperature on the day and air flow. Please refer to the Technical Bulletin: ardexaustralia.com/pdf/tech%20bulletins/TB130.014_Sources_of_Grout_Discolouration.pdf
@gttv9603 Жыл бұрын
Interesting you say Its not strong enough when for years people have been waterproofing and tiling plasterboard in wet areas...
@ardexaustralia Жыл бұрын
Our technical service department strives to offer best practice advice to the tiling community. Thanks for watching. We really appreciate your viewing!
@Yahgiggle Жыл бұрын
is this wpm 300, like been using this product for 15 years and its always been gray not yellow ???????????
@lindafergus3111 Жыл бұрын
I mistakingly put waterproof membrane down and now I’m told the floor needs to be more level to put laminate luxury tile down. What do I do? Thanks need help
@FishingWithMichaelTruong Жыл бұрын
Excellent product. I just used this on our bathroom renovation. Very smooth and easily to work with mix.