what if we have a p delta analysis how does the shear force and the overturning moment effect
@halilovayolu59159 ай бұрын
Mmax=225 kipft
@flamenballerG3710 ай бұрын
You're websites are not working FYI
@emmjay27411 ай бұрын
"Promo SM"
@bricegreco8292 Жыл бұрын
Can you do the problem for the uniformly distributed load on a beam fixed at one end and asked to find the tension in the anchor?
@pegenius Жыл бұрын
I'll do that one next. Thank you for your kind words 🙂
@bricegreco8292 Жыл бұрын
These problems have prepared me for the exam far greater than any other material I've reviewed.
@dylanbolton6297 Жыл бұрын
Great vid but Flexible Diaphragm means forces are distributed through tributary width, not stiffness so the 10' wall in your case scenario at the end that you mentioned would actually be the one to take greater load. If it were a Rigid Diaphragm, that would be the case but Flexible is written. Hope this helps!
@eugenekuehl11 ай бұрын
Can you justify this through code section? This seems to be correct as the shear flow will behave to what’s stiffer. Curious because I have a PC arguing your case.
@dylanbolton629711 ай бұрын
@eugenekuehl ASCE 7-16 Section 12.3 covers this but let me know if you can't find it and I'll get more specific for ya. Like you are getting at with shear flow, if the diaphragm flexibility is roughly over 2× the in-plane stiffness of the walls, it moves enough that the walls don't play a super important role on how strong they are and then everything distributes equally
@zimzim7 Жыл бұрын
What about the eccentric moment from the load being applied at the center of mass? Or in the question is it stated we are to assume the load occurs at the center of rigidity?
@mmrm2509 ай бұрын
Gravity loads act at centre of mass whereas lateral loads act on centre of rigidity
@zimzim79 ай бұрын
@@mmrm250 lateral load from seismic acts at the centre mass not the centre of rigidity
@safeesohail9133 Жыл бұрын
HI.. Guide me please.. after calculating this seismic design force for non structural.. how to put value horizontal force in staad pro when there is structural seismic force...please answer... or is this for designing bolts connection where electrical equipment need to fix on steel columns ???
@emadnadi5206 Жыл бұрын
Great video, however, you needed to show the elevation view for better illustrations
@karimgel Жыл бұрын
Thank you so much. Could you please post again the link example..to practice the exercise
@ibaha4112 жыл бұрын
Good effort. One caveat though; the chord is not ought to be designed with omega factor when it consists of rebars within concrete. It d require omega factor if chord members are to be connected with dry connections, but just for the connection part of it, not for chord member rebars.
@aboudeh21 Жыл бұрын
What do you mean by dry connection?
@ibaha411 Жыл бұрын
@@aboudeh21 E.g., mechanical connections.
@twigsfloat27732 жыл бұрын
Very helpful. Thank you!
@kirapiwpiw48042 жыл бұрын
hello, can you draw the free body diagram on how the forces act?
@ottertubetv93562 жыл бұрын
Dang it why is this so hard…
@farzadaalam35092 жыл бұрын
perfect
@farzadaalam35092 жыл бұрын
on the code the vertical load does not have the 1.2 in the formula
@farzadaalam35092 жыл бұрын
great content
@chrissyvillafuerte8722 жыл бұрын
the download example is broken
@babulchandra87603 жыл бұрын
Excellent and Outstanding We want more and more Video regarding Building design considering seismic forces Thanks