Пікірлер
@JasonBatz
@JasonBatz Ай бұрын
Think you meant 1 1/8
@johnnovaktr2fd677
@johnnovaktr2fd677 Ай бұрын
Jason, I believe you are referencing the one nozzle where I said it was a 1 3/16 inch. If that was the case, I did not miss speak. I was referencing a 1 3/16 inch tip for a 2 1/2 inch nozzle. Here is a good article that speaks to the advantage of the 1 3/16 inch nozzle (www.hydrant2nozzle.com/1-316-nozzle) If you were referencing something else could you be more specific so I can make the correction. However, thanks for watching the video.
@JasonBatz
@JasonBatz Ай бұрын
@@johnnovaktr2fd677 Chief, I could have sworn that when I watched the video the other day that your 2.5" example showed a 1.25" tip at 265. All good with 1 3/16 tip idea, we've played with that as well as the 1-1/16 Shupe tip for 2" lines! Thanks for the video.
@williammora7077
@williammora7077 9 ай бұрын
Dual Pumping has been actively used by the San Antonio Fire Department for over 23 years. (Since April 1, 2000) Results in numerous safety and efficiency benefits.
@robozoo2
@robozoo2 Жыл бұрын
Excellent video! I am currently studying for my c16 this is exactly what I was looking for.
@stevenandrade2979
@stevenandrade2979 Жыл бұрын
Awesome me too find anything else helpful ?
@NeilM01989
@NeilM01989 Жыл бұрын
Liked, subscribed and shared your video and channel
@KB-dg2gr
@KB-dg2gr Жыл бұрын
Thank u heros people dont know the work fireman have to do to be ready.
@mattd8411
@mattd8411 Жыл бұрын
Thanks for the video.
@joemomma5353
@joemomma5353 Жыл бұрын
Please tell me there is a second video coming from this fire? Good operation!
@johnnovaktr2fd677
@johnnovaktr2fd677 Жыл бұрын
This is the only dashcam video that the chief gave me. Fire was knocked down and extinguished with the 2 1/2". Some roof deck fire was extinguished with the tower.
@gort400
@gort400 Жыл бұрын
THANK YOU!
@Psychiatrick
@Psychiatrick Жыл бұрын
john Novak TR2FD ... How does water get to the 1,000' level from sea level? Certainly, with gravity, it would take tremendous amount of pressure to pump water to that level. My thought is there would have to be reservoirs at graduated levels to pump water from one reservoir to another. for example, each floor of the World Trade Center was about 1 acre. The demand on water would be such there must have been several direct pumps to satisfy restroom, restaurant and sprinkler needs. I would also like to "think" if you pumped water to the 10th floor reservoir then the 20th floor etc. the weight of the 20th floor could use gravity to service the lower floors. As the holding tanks become depleted they would be refilled not unlike a toilet holding tank. The Roof of the WTC would hold a reservoir with water flowing down under pressure. Sea water is about 1 ton per cubic yard.
@dboatube
@dboatube Жыл бұрын
ok.. but why post over an hour of clear air garage for no reason? cut the vid down to just the smoke.
@steveroberts9534
@steveroberts9534 2 жыл бұрын
Why do you suggest shutting down the fire pump once the FDC has been supplied? Is this your department’s SOP?
@johnnovaktr2fd677
@johnnovaktr2fd677 2 жыл бұрын
Steve, the fdc is connected to the system up stream of the fire pump. There is usually a check valve between the fire pump and the distribution side of the system. Once the FD connects to the system we usually pressurize the system at a higher pressure than the fire pump. This would close the check valve and the fire pump would be running at "Churn" (no water flowing). If the fire pump is not set up to shut off if running at churn then possible damage could occur. It is important to know your buildings and systems in your response area.
@mysuperintendent9095
@mysuperintendent9095 2 жыл бұрын
Very good explanations!
@davidgorejr2560
@davidgorejr2560 2 жыл бұрын
Who didn't like the video smh always 1 hater
@larrylasich5136
@larrylasich5136 3 жыл бұрын
Pro tip; attach a 3 inch line from the hydrant to the second Engine to maintain the residual pressure that the hydrant can provide. Re-enforce all hydrants by attaching 2 1/2 Gate Valves.
@aletapearce2369
@aletapearce2369 3 жыл бұрын
This is excellent if you are studying the IBC and want to have an understanding of these systems.