Пікірлер
@alexdokic5567
@alexdokic5567 4 күн бұрын
Excellent talk through on how to change the LCD, precise and very carefully done! I have just replaced the LCD and front case of a fluke 87V, but needed to remove the knob from the original front cover as the new one didn’t come with a knob. At first glance, it didn’t look like it was removable, but a quick look on the web showed how easy it was to remove!
@VCmakes
@VCmakes 28 күн бұрын
awesome video! Thank you! this was my repair based on your video, and my connectors got stuck like you said, and you do indeed need to loosen the 4 screws behind the LCD! kzbin.info/www/bejne/h2S2hKOgr82niZo
@JacobBitner
@JacobBitner Ай бұрын
The one i have, on AC setting, it sits at 2.2 but on DC it sits at -0.000 and jumps up to 0.001 then resets. Whats the fix on this issue?
@MultimeterParts
@MultimeterParts Ай бұрын
Not sure exactly, but component level considerations would be the varistor, and/or aged capacitors.
@JacobBitner
@JacobBitner Ай бұрын
@@MultimeterParts id imagine old age as well. But once the voltage is applied it's absolutely spot on. I enjoy this channel very much! (Technician on Italian machines for CGM) I use this 20 year old meter on a brand new TC2-H1700+P
@JacobBitner
@JacobBitner Ай бұрын
I have 2, an 87 iii and an 87. Could you list the differences. Ive fixed display issues with them and broken battery wires but they work amazing after 20 years
@MultimeterParts
@MultimeterParts Ай бұрын
The differences between the Fluke 87 and Fluke 87 III are: Fluke 87 III has the newer white LCD backlight, as well as an easily accessible 9v Battery via the battery door. There are subtle upgrades in the specs with the Fluke 87 III. The legacy Fluke 87 and Fluke 87 III are still solid industrial multimeters. We hope you get get another 20 years out of them. Thank you for your comment!
@JacobBitner
@JacobBitner Ай бұрын
I have 2 and i love them.
@brittanyjacobsen6508
@brittanyjacobsen6508 Ай бұрын
Doesn’t the disk say 78?
@Ni5ei
@Ni5ei Ай бұрын
This was my first decent multimeter. I bought it on sale and it came with the TL175 test leads. Sold it after a very short time because it doesn't even have a Rel function. I got the same price as I paid for it but I kept the leads so I got these for free 😂
@HankO559
@HankO559 2 ай бұрын
Hardy thanks for the video. I was able to restore my display.
@MultimeterParts
@MultimeterParts 2 ай бұрын
Excellent! Happy to help!
@wallyj2000
@wallyj2000 2 ай бұрын
Where were the faded segments? I did not see any would've been nice if you could've showed them in more detail so we could see before and after.
@VCmakes_Adv
@VCmakes_Adv 28 күн бұрын
at beginning of video 'Auto Range' (lower left of display) is only thing I could see that might be faded
@junaidinajun9818
@junaidinajun9818 4 ай бұрын
Flukw 25
@MultimeterParts
@MultimeterParts 4 ай бұрын
Disassembly begins @2:00
@Dendyfeb
@Dendyfeb 4 ай бұрын
My Fluke 87v has the same problem, the "batt" appears and after I replaced the battery with a new one, it's still not normal. (caused by exposure to rainwater) can you help me solve this problem🙏
@MultimeterParts
@MultimeterParts 4 ай бұрын
Try disassembling completely, and spraying down the main PCB (circuit board) with 90% (or higher) Isopropyl alcohol. Let it air dry for a few days, then re-assemble and see how it goes. Please share updates. Thanks for commenting, and good luck.
@MultimeterParts
@MultimeterParts 4 ай бұрын
Link to Fluke 87V disassembly and breakdown: kzbin.info/www/bejne/e4SYkKaPaq54otEsi=0RG6YYziSu14Z-Vw
@Dendyfeb
@Dendyfeb 4 ай бұрын
@@MultimeterParts There is something burnt around the zinc covering the PCB, could that be the cause?🙏
@MultimeterParts
@MultimeterParts 4 ай бұрын
@@Dendyfeb yes, but clean with the 90% or higher alcohol. Make sure it's not surface rust. If it's obvious that it's burnt, then need to replace that component, if possible. Less replaceable parts on Fluke 87V, so may need to replace entire PCB. If it's only surface rust, then there is a chance it can be cleaned and brought back. Good luck! Thank you for your update!
@MrBobWareham
@MrBobWareham 4 ай бұрын
Your cleaning cloth should be lint free!!
@felixcole3726
@felixcole3726 5 ай бұрын
"promosm"
@elmergutierrez6381
@elmergutierrez6381 5 ай бұрын
Ic repuestos
@mahmoodmirza3301
@mahmoodmirza3301 6 ай бұрын
Thank you dear for this operation of dimmed Fluke Display.
@autolancegega599
@autolancegega599 6 ай бұрын
where can i get the display , my fluke 87 V display is gone bad, black botched up display.
@MultimeterParts
@MultimeterParts 6 ай бұрын
Are you looking for a Fluke 87 LCD, or Fluke 87 V LCD? We may have both in stock. Will get back to you. Thanks
@autolancegega599
@autolancegega599 6 ай бұрын
Do you know where I can find the display and elastomer ?
@gregorypierce6703
@gregorypierce6703 6 ай бұрын
Worth giving it a try. Fingers crossed
@gregorypierce6703
@gregorypierce6703 6 ай бұрын
Any fix it videos?
@MultimeterParts
@MultimeterParts 6 ай бұрын
See other videos on this channel. The basics are the same for all models in the same series. Example: All 80 Series Include all Flukes 83, 85, 87, and 88. All 70 Series Include 73, 75, 77, 78, 79, and all 170 Series include Fluke 175, 177, and 179.
@gregorypierce6703
@gregorypierce6703 7 ай бұрын
Is their a video of the process?
@MultimeterParts
@MultimeterParts 7 ай бұрын
standby, will add link. thank you.
@MultimeterParts
@MultimeterParts 7 ай бұрын
link to Fluke 23 disassembly and LCD removal. Use this for Fluke 78, all other Fluke 70 Series, Fluke 20 Series, and Fluke 50 Series Thermometers. They are all the same. Use alcohol pads to wipe the top and bottom edges of the elastomeric connectors, and then simply re-insert.: kzbin.info/www/bejne/nITIZ5qPfMqDn6s
@MultimeterParts
@MultimeterParts 7 ай бұрын
can use use isopropyl alcohol 70%-90%
@gregorypierce6703
@gregorypierce6703 7 ай бұрын
Post a video of the cleaning process because mine is having this issue. Thanks
@gregorypierce6703
@gregorypierce6703 7 ай бұрын
How much r the replacement parts?
@MultimeterParts
@MultimeterParts 7 ай бұрын
all elastomer display repair kits $14.99
@rbmwiv
@rbmwiv 7 ай бұрын
Mine is still going strong.
@MultimeterParts
@MultimeterParts 7 ай бұрын
Awesome! thanks for sharing.
@niniliumify
@niniliumify 7 ай бұрын
Older equipment is better made and designed for maintenance.
@MultimeterParts
@MultimeterParts 7 ай бұрын
touché
@etechniques
@etechniques 7 ай бұрын
I think Need to change the polarizer film
@gregorypierce6703
@gregorypierce6703 8 ай бұрын
U tried. Do u have a video for the other display issue? Mine is doing that. Thanks
@MultimeterParts
@MultimeterParts 7 ай бұрын
Will look into posting up on this soon. Thanks!
@WreckDiver99
@WreckDiver99 9 ай бұрын
Kit no longer available. Contacted Fluke to repair my meter for this issue. No longer servicing the Fluke 87 True RMS, but I could buy a new one from them for nearly $400. I tried to have this repaired back when it started happening back in 1993~1994 timeframe, but they wanted $250 as a "repair fee". I paid $225 for the meter (maybe less). I wasn't happy for sure. :(
@spartanreece9908
@spartanreece9908 6 ай бұрын
I found them for sale on fleabay for under 20, and it has worked no issues
@WreckDiver99
@WreckDiver99 6 ай бұрын
@@spartanreece9908 Maybe I'm blind or have zero idea how to use the old fleabay any longer, but there are no 'screen' or 'kits' or pretty much anything for the Fluke 87. I guess I continue to take it apart, clean the pads, and move on. Probably the last Fluke I ever buy after their piss-poor customer service with me (and yes, since I bought the meter).
@pablocamacho2605
@pablocamacho2605 9 ай бұрын
I wish you would have shown the display read before hand. Mine is having similar issues as described so I'll try this first before replacing the connectors
@MultimeterParts
@MultimeterParts 9 ай бұрын
We'll update this information based on your recommendation. Thank you. Try cleaning the display contacts first. If display is only fading, then cleaning will fix it most of the time. Thank you for your feedback, and check out our multimeter parts site...we're updating our database. Thanks again!
@fatkhannour2595
@fatkhannour2595 10 ай бұрын
Hi Great information, i would like to ask you that my 179 have problem in LCD display was not faded but have a black spots such as sunburn LCD, can i only replace the LCD polarizer layer or it should replace the whole LCD? And the other problem is the selector knob was broken, can i replace the selector knob? Because i cant get the replacement knob in Indonesia.. i’ve already looking for the knob in several e-commerce in indonesia Many thanks
@MultimeterParts
@MultimeterParts 9 ай бұрын
We apologize for the late reply. When the LCD is bleeding, as in the case of the black spots, then the only solution is replacing the LCD. We do not have this in stock at the moment, but we are updating our inventory and website. Let us know what you're looking for and we'll do our best to accommodate. Thanks for checking us out.
@9ballz
@9ballz 10 ай бұрын
If they will last for 20 years why only 90 day warranty? Just messing with ya...
@MultimeterParts
@MultimeterParts 9 ай бұрын
We're updated our Warranty to 12 months...1 Year. We're updating our database and inventory of replacement parts. Thanks for your feedback.
@9ballz
@9ballz 9 ай бұрын
@@MultimeterParts Ordered new gray elastomers for my very old Fluke 87 and they work great. Thanks
@MultimeterParts
@MultimeterParts 9 ай бұрын
Terrific! Thank you for your feedback, and we're always here when you need us. Cheers!@@9ballz
@anthonywhite17128
@anthonywhite17128 10 ай бұрын
Great information tried it on my fluke, 87 and it worked just like you said thank you again .
@MultimeterParts
@MultimeterParts 9 ай бұрын
Terrific! We're glad it worked out. Thanks for your feedback.
@andrewmiddleton1762
@andrewmiddleton1762 10 ай бұрын
Thanks, gave me the confidence to remove the LCD plastic surround, and replace for a new screen and elastomeric connectors on a 87V ex
@MultimeterParts
@MultimeterParts 9 ай бұрын
This is great! We're here to help, and glad it worked out.
@luischavarria591
@luischavarria591 Жыл бұрын
Marco con el selector y en todas las funciones sale batt cambie una batería 9vDc nueva y sigue igual
@MultimeterParts
@MultimeterParts 9 ай бұрын
Si la pantalla se desvanece, intente limpiar antes de reemplazar los conectores elastoméricos. Si es posible, ¿puede incluir una imagen de su medidor? Veremos si podemos diagnosticar. Gracias por tus comentarios. If the display is fading, try cleaning before replacing the elastomeric connectors. If possible, can you include a picture of your meter? We'll see if we can diagnose. Thanks for your feedback.
@luischavarria591
@luischavarria591 Жыл бұрын
Hola tengo un fluke 179 con la falla de batt como se puede solucionar esa falla
@MultimeterParts
@MultimeterParts 9 ай бұрын
Esto puede ser una falla de un componente interno. Reemplazar la batería con una que se sepa que está en buen estado no solucionará el problema, si este es el caso. Para diagnosticar, será necesario abrir e inspeccionar la PCB principal. Puede deberse a una prueba de sobrevoltaje en el medidor. Espero que esto ayude y gracias por tus comentarios. This may be an internal component failure. Replacing the battery with a known good battery will not fix, if this is the case. To diagnose, it will require opening up and inspecting the main PCB. It may be caused by testing over voltage on the meter. Hope this helps, and thanks for your feedback.
@swp466
@swp466 Жыл бұрын
Do you have a link to purchase the new gray version of the strips?
@MultimeterParts
@MultimeterParts 9 ай бұрын
These gray Fluke 170 Series elastomeric connectors may be found on our website here: multimeterparts.com/replacement-parts/fluke-170-series-elastomeric-connectors-j1-j2-650264-replacement/ Thank you, and we look forward to accommodating your parts requests.
@Bill_the_Terrible
@Bill_the_Terrible Жыл бұрын
Thank you very much! I just fixed my 83 that had some dimming display issues. This worked very well. Looks like new.
@MultimeterParts
@MultimeterParts 9 ай бұрын
Thank you for your feedback! We're glad it worked out.
@AFTABAHMED41
@AFTABAHMED41 Жыл бұрын
hI, I am soryy to say you have not clean card and it busbar .
@jaidencal1323
@jaidencal1323 Жыл бұрын
Best solution would be not to buy fluke products ive had two multi meters gone wrong . !! Waste of money
@electron7373
@electron7373 Жыл бұрын
Great tutorial! BTW , you sound just like Bob Dylan - uncanny!
@alexandrerizzardo6443
@alexandrerizzardo6443 Жыл бұрын
It worked for my 87 and 88 fluke 👍
@MultimeterParts
@MultimeterParts Жыл бұрын
Awesome! Thanks for sharing!
@canebuilder3520
@canebuilder3520 Жыл бұрын
six years later, this worked perfectly, clean display! Thanks . Wondering why this is a “ temporary fix”? I also noted imprinting( little dents) on the downside of of the elastomer strips, I replaced them the same way thinking they might not contact the glass too well.
@MultimeterParts
@MultimeterParts Жыл бұрын
Six years and counting...and here's to many years to come. Thanks for sharing!
@kledlive4435
@kledlive4435 Жыл бұрын
Great video. Would your kit be good for my 8020A?
@MultimeterParts
@MultimeterParts Жыл бұрын
Let me see what I can find out and will get back to you. Thank you for checking us out!
@yulianto7032
@yulianto7032 Жыл бұрын
What's wrong ?
@oswaldfraser4946
@oswaldfraser4946 Жыл бұрын
I have a fluke 77iv multimeter,when it's turned on the display is on the same way for all functions,please help.Thanks
@MultimeterParts
@MultimeterParts Жыл бұрын
When you state it's the same way, you mean the display is on VDC, for example, for all the functions? Is it all zeros? Try taking apart and making sure that the range selection knob is positioned correctly and that all the contacts are clean and in the proper place. I'll try to post a video of the Fluke 77IV, or compatible soon...if I have one. Thanks for reaching out. I hope this helps.