Пікірлер
@nnajigabriel969
@nnajigabriel969 Күн бұрын
Can we have full diagram of full sycronization of two generations of different ratings
@Keyal2310
@Keyal2310 2 күн бұрын
Wow! enjoyed this session and used in application for my project too
@kumereshan
@kumereshan Ай бұрын
Thank you sir 🙏
@swapnilmotharkar5057
@swapnilmotharkar5057 Ай бұрын
Thank you sir
@hemachandarg
@hemachandarg Ай бұрын
Thankyou very much sir .Your assistance helped me lot to understand the design requirements
@amppowersystem6084
@amppowersystem6084 Ай бұрын
@@hemachandarg share it widely
@jeevankoshy9027
@jeevankoshy9027 Ай бұрын
sir, I am so happy that you are back.Your courses were immensely helped me in my career.I just want you know that my friends who are working in ABB,Schneider and General Electrical are also your subscribers.We greatly appreciate your efforts.Please continue the series
@amppowersystem6084
@amppowersystem6084 Ай бұрын
@@jeevankoshy9027 sure
@arghyamukherjee8583
@arghyamukherjee8583 Ай бұрын
Sir why then we use low impedance differential protection
@amppowersystem6084
@amppowersystem6084 Ай бұрын
Where there is a chance of CT ratio mismatch and / or polarity change and / or CT used mixing with new and old and / or CT s are different make type etc, it is better to use low impedance differential protection. Moreover, low impedance protection work on current value but high impedance work on voltage across the relay terminal. Low impedance system: each CT wire needs to be connected to the relay but high impedance it is not so. Future feeder expansion may be difficult while the protection is low impedance type
@kucingpowergile
@kucingpowergile Ай бұрын
Thank you sir for coming back making video..really appreciate this.
@amppowersystem6084
@amppowersystem6084 Ай бұрын
@@kucingpowergile share it more with your friends , colleague
@hedejan
@hedejan Ай бұрын
This lecture is uniquely amazing and essential for Protection & Control Engineers. Just a couple of minor points: I believe device no. 80 is a Liquid or Gas Flow Relay, not a DC current flow relay. Also, I couldn't find a reference for 99 being used for transformer over-fluxing protection; it seems to be device number 24. Thanks for the great lecture!
@amppowersystem6084
@amppowersystem6084 Ай бұрын
80 is flow switch which could be liquid, gas , power etc. As we are dealing electricity , we can use it for Power switch change over scheme as an option 99 is not assigned yet but we can use it as per our convenience. Some engineer use it for overfluxing / over excitation .
@hedejan
@hedejan Ай бұрын
@@amppowersystem6084 Isn't device number 24 already designated for over-excitation? Could you please provide references for using device numbers 80 and 186 for electrical current flow and auto-reclose lockout functions? Thank you, Sir.
@methesha5756
@methesha5756 4 ай бұрын
SIR PLEASE MAKE A VEDIO FOR THREE PHASE 415 VOLTS CABLE SELECTION FOR MOTORS IN INDUSTRIES
@madhrisichatterjee45
@madhrisichatterjee45 4 ай бұрын
Very useful Sir. Thanks.
@J07J
@J07J 5 ай бұрын
Top class lecture thanks sir
@pavanacharya999
@pavanacharya999 5 ай бұрын
Very good information sir
@MdShaddamHossen-pi6ds
@MdShaddamHossen-pi6ds 5 ай бұрын
Excellent
@نصرالدينجليلة
@نصرالدينجليلة 6 ай бұрын
Thank you verry much
@prabhatsingh5377
@prabhatsingh5377 6 ай бұрын
You have not discussed 78 and 64R protection
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Sir kindly give ur number so that i can clear my doubts. Your teaching skills are exceptional
@cbsuresh5631
@cbsuresh5631 7 ай бұрын
Earthing trafo (zig zag /star )can we use fr earthing cum distribution purpose.
@cbsuresh5631
@cbsuresh5631 7 ай бұрын
Delta... System used in SAIL&TISCO OPEN DELTA PT USED TO GIVE ALARM.
@pbsubhash
@pbsubhash 7 ай бұрын
EXCELLENT CLASS👏👏
@pbsubhash
@pbsubhash 7 ай бұрын
extremely good class.. thanks for your valuable time.
@pbsubhash
@pbsubhash 7 ай бұрын
Very good lecture. thanks
@vipinthampy4669
@vipinthampy4669 7 ай бұрын
Hi sir classes are good.do u give training on switch gear panel designing
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Excellent 👍
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Amazing session. Pls uploading sir more videos like this
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Keep uploading sir🙏
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Mind blowing sir😊
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Excellent presentation
@prabhatsingh5377
@prabhatsingh5377 7 ай бұрын
Excellent 👌
@rakeshchauhan4343
@rakeshchauhan4343 8 ай бұрын
Plz make video in Hindi language thank you
@rakeshchauhan4343
@rakeshchauhan4343 8 ай бұрын
Uncle g Hindi m btate to hm bhi samjh jate
@santhoshr53
@santhoshr53 9 ай бұрын
Sir can get your contact no
@mominhamdani4012
@mominhamdani4012 9 ай бұрын
Thank you for sharing your knowledge.
@sanjayakumardas531
@sanjayakumardas531 Жыл бұрын
Excellent lectures for new learners.Thank you sir for sharing knowledge.
@tuna6423
@tuna6423 Жыл бұрын
Sir, IEC does not mention in case we use XLPE current rating against 90deg max temp of its insulation This rating will bring conductor to equilibrium temp 90 degree which is not suitable for terminal of equipment which rated only 75 degree. In this case, How to rectify this problem?
@amppowersystem6084
@amppowersystem6084 Ай бұрын
It shall be read as conductor temperature on continuous rating and not insulation. Slip of tounge
@wongsabarchannel1335
@wongsabarchannel1335 Жыл бұрын
How you categorize load as continuous or intermittent Load? When you have Pump with as following : 1. Running in 1 hour per day 2. Running in 3 hours per day, then standby 3. Running ini 6 hours per day, then standby 4. Runninh in 12 hours per day, then standby 5. Running for 75 hours per day, then standby. What you classify above motor respectively ? As continuous or intermittent Load? I have Terminal LPG Plant that the pumps running as above condition, and it decided to sizing of 3.3 kV Bus Bar and Power Transformer.
@piyushtct
@piyushtct Жыл бұрын
Good explanation sir
@rajarathanam21
@rajarathanam21 Жыл бұрын
All the 3 CT shall be connected to relay always. But in your video CT connected in phase side, shows one phase CT only with one relay and explained fault happen on other phase will not detect by other CTs. Why dont we connect the CT in same way as in neutral side, so relay will find the fault?
@amppowersystem6084
@amppowersystem6084 Жыл бұрын
I dint get you friend. 3 CTs shown on the neutral side for 51v protection. Time ref 4.37 minuts onward Can i request your support to look in it and send me the screen short where you have noticed it. Many thanks for looking into this presentation. Regards Paul
@amppowersystem6084
@amppowersystem6084 Жыл бұрын
Further to this , here generator is the source and if the fault ahead of CT towards generator fault current will not appear in the CT secondary and relay will remain in active .
@vajashailyajeet5306
@vajashailyajeet5306 Жыл бұрын
Sessions of Sir are like rarely found precious gems
@amppowersystem6084
@amppowersystem6084 Жыл бұрын
Thank you
@pankajnag8381
@pankajnag8381 Жыл бұрын
This video helped me a lot in understanding the ratings of a generator. Thank you so much.
@VARGHESEVS-e9k
@VARGHESEVS-e9k Жыл бұрын
Thank you sir very useful informations
@sachinpampatwar8046
@sachinpampatwar8046 Жыл бұрын
Very informative
@ajithjohnson5140
@ajithjohnson5140 Жыл бұрын
very hard to understand
@amppowersystem6084
@amppowersystem6084 Жыл бұрын
If you kindly let me know the exact point i may help you
@anuragravi333
@anuragravi333 Жыл бұрын
Very informative and nice explanation, thank you sir for sharing these valuable informations. Appreciate your efforts.