Thank you sir …. We found this video and were able to rectify the problem … im eternally grateful as i sit poolside in key largo enjoying this 80 degree day
@RHSuarez4 ай бұрын
Field Test per instructions is not to be used on multiple wires.
@bradloppe48484 ай бұрын
You sir are a Rockstar! Thank you! Been dealing with this problem all summer and yours is the only fix to date that has worked!
@johncastle33509 ай бұрын
You take tooooo long to explain something
@leahh12829 ай бұрын
How do you do a reset? I don’t have a rest button
@hunterstark95569 ай бұрын
Enjoyed the video mate
@greghinds828711 ай бұрын
I did a reset on mine and now it's not showing the furnace. Not even showing me that I have one
@KDCantelon Жыл бұрын
Thanks! We were able to access the “other end” of the thermostat phone Jack by removing the AC ceiling vent or AC air intake in our 2019 flying cloud. Our unit is “ducted” with all of the wiring accessible by removing the intake filters.
@donnasteger2434 Жыл бұрын
Thank you so much for this video! This was our problem. The RV man said we were going to have a whole new AC unit. So glad I found your video first. We did access our Drip pan from the roof unit though.
@ernestkettig2633 Жыл бұрын
You’re right about it being able to test capacitors I come in from there viewpoint of a high-voltage lineman I don’t know what it would reach our are capacitors or not the 200 amp home Services are very common is definitely a plus for us when you’re dealing with 200 amp services all the time pulling up on residential customers that are out and then you might want to check a primary load wire wire wherever high in the sky are in a pad mount transformer you need that extra amperage
@hannaht87202 жыл бұрын
You just saved me a lot of time and an inconvenient trip to Airstream. Thank you!!!!
@russellwestern69972 жыл бұрын
"can take it to the bowling alley"!!! That's good to know, nothing worse than finding yourself at the lanes without a clamp meter haha. Sorry mate, just my little joke, was searching these vids cos my ne won't register an amp and i've got a big load test coming up.
@PoptartFps2 жыл бұрын
T6-1000 shows Voltage and amps at same time
@walterandykathleen2 жыл бұрын
Thanks for the video! Sounds like my problem. I’m pretty sure that wire is the remote temperature sensor.
@go2four2 жыл бұрын
Canada has 600V 3 phase, so the 1000 model is more for the Canadian market and other countries like us.
@swompy51462 жыл бұрын
I have the same 32-degree problem trying to have heat. But I find no water, and the end is just bare wire. Heat won't stop. Any suggestions? Please, and thanks.
@Dextermorga3 жыл бұрын
The problem is not field sense. The problem are people who does not know how to use it ( how you can see in this video, bloody people read the f… manual) 1000V version is showing simultaneously volts and amps. T6 is true RMS meter
@Jetski2703 жыл бұрын
Field Sense is not meant to test the wires over its insulation.
@davidmason593 жыл бұрын
In the USA where 480 volts is the norm. We in Canada use 347/600 volts 3 phase power. I often see 620 volts I would not want to work with something that is underrated. All my Fluke meters are 1000 volt rated.
@jaycarneygiants3 жыл бұрын
Joe Smith proved it works up to 660 volts
@patrickjacobsen78053 жыл бұрын
Cheers mate definitely will go and purchase the t5600
@patrickjacobsen78053 жыл бұрын
Definitely will be taking it out clubbing
@fishmonger68793 жыл бұрын
Great Job
@--JohnDoe3 жыл бұрын
I got this to differentiate between induced voltage and 120v.
@jackprick97974 жыл бұрын
I really appreciate your real world review of this meter. It seems to me your conclusions are reasonable and valid. Considering that the T-5 is still available and I am looking to get one of these, I think I will stick with it rather than this T6.
@joealcantar2914 жыл бұрын
I’m with you on this , idea was to not probe with leads. But you still have to open up panels etc. to get a reading. Agree on capacitance function would have made a great improvement.
@Daniel-lf2no4 жыл бұрын
Fieldsense doesn't work if you try to measure two or more conductors of different phases, so your product review is invalid.
@ampdrawrepair53524 жыл бұрын
Daniel that was my entire point of why fieldsense is completely useless since its incapable of measuring 208 volt and above. It does no more good than just using a voltage sense probe.
@olboy822 жыл бұрын
What about 277v? 🤦🏽♂️
@iceinyourveins-rn7em7 ай бұрын
@@ampdrawrepair5352 The manual says it reads voltage up to 600V, now if your dealing with a 3 phase system with a 208 high leg it should be able to read that, same thing with 3 phase 480V one leg should read around 277V but obviously this meter or even the 1000 version will not be able to read more than 277V since that requires the 2 probes to be placed on 2 legs simultaneously. Fluke still did really good here with the fieldsense technology. It obviously has its limitations but its more to do with electrical theory and its fundamental principles and not actual engineering of the instrument.
@hvaccuffingit64714 ай бұрын
@@ampdrawrepair5352it’s meant for testing singles not a multi core cable. Very similar to trying to take an amp reading on a multi core cable reads 0.
@Daniel-lf2no4 жыл бұрын
You aren't supposed to touch the wire under test while using fieldsense.