Really helpful video -appreciate time and effort doing this . However it looks as though there has been yet another update -i do not have the weather option ( but ok as unlikely to use this feature) but when i look at Octopus charge tariffs, I now have a graph instead of times. I find this difficult to check the best half our slots and check my charge times/points . And when i go into management the screen is very different to what you shoed - there are and number of drop down menus . At times i am not sure how best to set these up and if i get a conflict e.g. if I select my number os set point to charge overnight but i also set to charge when negative price , is there a conflict. I am very disappointed that flux/ Infinity innovations are not producing decent information on any software updates. I am not sure if you can do a quick update video based on the latest version . It would be much appreciated . Thank you
@YorkshireAutomation
@YorkshireAutomation 23 күн бұрын
i will try and get one doine shortly. thanks
@josephcharles8764
@josephcharles8764 Ай бұрын
hi my name is joseph ,sir I have issues with luxpower 5kw invetor is not able to charge the battery with grid
@Dh2212an
@Dh2212an Ай бұрын
Hi, I am having issues with the ac charge. Basically when I put the time between 2am to 5am to charge batteries from the grid, it charges from 2am to 3am then it just stops charging from the grid when it should continue till 5am. It then just uses the grid to power the house. Any idea why this is happening? Would really appreciate the help.
@YorkshireAutomation
@YorkshireAutomation Ай бұрын
hi i do need some more info. can you send screenshots of your settings to my email - [email protected] - also need to know how many batteries you have and size aswell as what lux you have. thanks
@Dh2212an
@Dh2212an Ай бұрын
@@YorkshireAutomation hi there, Thanks for responding. I got it working now. Only issue now i am facing is the battery not being discharged at its full capacity. It discharges at 3300w but not at 3600w. I have a 3.6kw hybrid luxpower system with 5 batteries. Is this normal or is it meant to discharge at full capacity?
@YorkshireAutomation
@YorkshireAutomation Ай бұрын
@Dh2212an that is ok as it works on current and the battery voltage. Temp also has an affect on the charge and discharge rates. So 3.3kw is within range
@Dh2212an
@Dh2212an Ай бұрын
@@YorkshireAutomation how come on the luxpower manufacturer website it states it can discharge at 3600w with a 3.6kw system? It’s missing the extra 300w which is quite a lot.
@YorkshireAutomation
@YorkshireAutomation Ай бұрын
@Dh2212an under ideal conditions it will charge/discharge at full rate. Ambient temp is the biggest factor
@romanmelnyk2446
@romanmelnyk2446 Ай бұрын
Thank you for the review and real demontration how it works!
@alinaprykhozha9862
@alinaprykhozha9862 Ай бұрын
Hi , I need your help , I lost the code and I can’t go in ……
@YorkshireAutomation
@YorkshireAutomation Ай бұрын
yorkshireautomation.co.uk/downloads/RFIDmanual.jpg. use this to get the instructions to reset the keypad. Thats your only option
@robinlander1158
@robinlander1158 Ай бұрын
when i click on read I get the not available sign, do you know why this is happening.
@YorkshireAutomation
@YorkshireAutomation Ай бұрын
Could be server maintenance. They tend to do that on Sundays. Try again later in the day
@ducnm4885
@ducnm4885 Ай бұрын
I am using SNA 6k, but at Discharging pagei cannot file the time setup, only can setup by Volt or SOC
@YorkshireAutomation
@YorkshireAutomation Ай бұрын
I'm not familiar with the sna version as we don't have that here. I'm afraid you will need to contact your distributor or installer.
@imend-itsolutions125
@imend-itsolutions125 2 ай бұрын
We have load shading and times are not specific how do i leave the on grid charge to charge at any time we have on grid ?
@ahmermohammad2556
@ahmermohammad2556 2 ай бұрын
unfortunately you cant, you will be better with an off-grid inverter instead which has the features to charge batteries whenever grid is present and use grid energy when present and auto switch to batteries when grid goes off.
@erwin8335
@erwin8335 2 ай бұрын
Thank you for this informative video. Im trying to change my settings so that the system runs off of my batteries at night up to a certain battery percentage (say 30%). Only then should the grid kick back in. Is this possible with Luxpower? At the moment my batteries are constantly set at 100%
@ahmermohammad2556
@ahmermohammad2556 2 ай бұрын
hi the grid kicks in when the batteries reach the setting in the SOC for discharge. the system is designed for max discharge when there is power in the batteries. however if you want to use the grid when batteries is above 10% (or 5% for hanchu) then set this figure under discharge
@blue7334
@blue7334 2 ай бұрын
Hello i want to ask something in my device i can added 2 card and when i want to add the third one it does not work do you have any information about this could help me please ? Info > the card is working but the device doesn’t allow me to add more than 2 help please):
@YorkshireAutomation
@YorkshireAutomation 2 ай бұрын
@blue7334 it has capacity of the 3rd card is not adding. Try to do a reset and add the cards again. Otherwise you may need to change the key pad
@mar4elo999
@mar4elo999 2 ай бұрын
Hi, I wonder if you could help I just connected PV2 - another set of 4 solar panels, to existing 12 panels (pv1) do I need to change any settings? I have only changed settings to pv - 2 separate connections, options were given separate or paralel, I selected 2 separate. I hope my question makes sense, I am new to all this. Thanks in advance
@YorkshireAutomation
@YorkshireAutomation 2 ай бұрын
@@mar4elo999 that's correct settings. So should be ok
@mar4elo999
@mar4elo999 2 ай бұрын
@YorkshireAutomation It looks like the inverter has adopted and started to produce. Thanks for your reply! 🙌
@darrellhooper9973
@darrellhooper9973 3 ай бұрын
Very informative.... if my car charges 0030-0530, how do I get the battery to charge at the same time? It seems to empty the battery instead of charging both! Thanks
@YorkshireAutomation
@YorkshireAutomation 3 ай бұрын
you need to enable the AC Charge option and set the time 0030 to 0530. this way it will simultabeously charge both car and batteries.
@dawoodrecitation
@dawoodrecitation 3 ай бұрын
Hi How to disable the zone control ?
@YorkshireAutomation
@YorkshireAutomation 3 ай бұрын
Just delete the specific zone in the climate panel OR if just temporarily you can just switch to manual mode
@lescrawford2650
@lescrawford2650 3 ай бұрын
Thank you for your help, am i right in thinking that two batteries and inverters in parallel will give my home 10kwh so we can run multiple appliances at the same time. Such as a kettle 2.8kw, 2x industrial iron's 3kw each as my wife works from home and uses a lot of energy.
@YorkshireAutomation
@YorkshireAutomation 3 ай бұрын
Again it depends on the inverters/charge controllers. If they are 5kw rated then yes, in parallel they will give you 10kw
@lindamilton1521
@lindamilton1521 3 ай бұрын
Thanks for replying. I decided to do the obvious and switch off all batteries and my LuxPower unit for 5 minutes. It all worked perfectly after turning back on. Your video was very helpful. Thanks.
@lindamilton1521
@lindamilton1521 3 ай бұрын
In the last few days my pylontech batteries will only charge to 87% from the grid during my 7 hours of low price time at night and shows a red light on what i think is the master battery. (They always charged to 100% before that). I have the On-grid Cut-off set to 10% as set by my installer but the day this fault started the SOC went down to 9%. Could that have been the cause of the problem? However they will then charge to 100% later in the day when the solar panels kick in and no red light. Any suggestions for a solution? Thank you
@YorkshireAutomation
@YorkshireAutomation 3 ай бұрын
i would suggest getting back in touch with your installer to take a look at the batteries. you shouldnt be getting any alarm lights at all, and this is what is probably causing the reduced charge
@saliaaugustine932
@saliaaugustine932 3 ай бұрын
What if I had the image of the card in my phone, could i be able to open the door 🚪 using the image of the card on my phone?
@YorkshireAutomation
@YorkshireAutomation 3 ай бұрын
no. rfid is a radio frequency
@saliaaugustine932
@saliaaugustine932 3 ай бұрын
@@YorkshireAutomation Thank you dear
@sweetsandnuts
@sweetsandnuts 4 ай бұрын
i had a power failure at Easter. Since then i can not get the battery to connect properly to the lux inverter. using a Pylontech battery I would appreciate any help
@sweetsandnuts
@sweetsandnuts 4 ай бұрын
Thank u for the settings, i really messed mine up not knowing what to do
@preciousamaristelva2599
@preciousamaristelva2599 4 ай бұрын
Idol pwede din bang nag set up ng card kahit hindi mo na babaguhain ang lock code at system code?
@stephenmugglestone9784
@stephenmugglestone9784 4 ай бұрын
How do you set the max battery capacity to less than 100%?
@YorkshireAutomation
@YorkshireAutomation 4 ай бұрын
Under charge settings, SYSTEM CHARGE SOC % - this is set to 100% - this means the solar will charge it to 100%. This is separate to the AC Charge settings
@pitiwatkittiwimonchai4656
@pitiwatkittiwimonchai4656 5 ай бұрын
may i ask some questions please. 0. I just saw luxpowertek inverter model SNA6000W on internet. 1. can this inverter sync electricity come from solar cell/battery and grid. (i mean use both of electricity from solar cell/battery and grid in same time. ex. house load = 6kw and inverter can divide into 3kw from solar cell/battery + 3kw from grid) 2. this inverter can schedule/program charging/discharging time right ? lastly in my country it's so fuxk shit (bad) when i want to sell electric from my own solar cell.
@YorkshireAutomation
@YorkshireAutomation 5 ай бұрын
Hi i believe that all luxpowertek have the same software. the model number you have asked isnt a UK model so i cant comment on the the different regulations that you may have. Its best to ask a local installer re if the inverter is grid tied or off-grid
@pitiwatkittiwimonchai4656
@pitiwatkittiwimonchai4656 5 ай бұрын
@@YorkshireAutomation Thx for feedback sir.
@Bigglesworth-jv9iw
@Bigglesworth-jv9iw 5 ай бұрын
Any chance of a video doing a setup that fits the Octopus Flux tariff with set ups for charge and discharge and after discharge leaving enough battery charge to get through the night.
@YorkshireAutomation
@YorkshireAutomation 5 ай бұрын
octopus flux is just charging between 2am and 5am. but for discharge that varies between household to household. you would need to guage how much energy you need to take you through the night and set the STOP DISCHARGE SOC accordingly. i have talked about that in the video
@Bigglesworth-jv9iw
@Bigglesworth-jv9iw 5 ай бұрын
Great video and much needed. I think your video is already out of date as under charge setting their is now a System Charge SOC Limit % - Not fully sure what this implies i.e is this 100 % charge to achieve SOC percentage?
@YorkshireAutomation
@YorkshireAutomation 5 ай бұрын
yes fortunately and unfortunately... at least they are updating the software and adding features and fixing bugs!
@lescrawford2650
@lescrawford2650 3 ай бұрын
Hi, I have an 18.8 kw battery, what size lux inverter do I need to force charge and discharge the battery in the 3hr windows on octopus flux.tia
@YorkshireAutomation
@YorkshireAutomation 3 ай бұрын
@@lescrawford2650 most of the charge/discharge rates are 3.5kw. so the only option you have is the squirrel pod option. Setup 2 in parallel and have the batteries split between the 2. This will then give 100% in 3 hrs
@xxXCoolJokeXxx
@xxXCoolJokeXxx 5 ай бұрын
whats the difference between forced discharge and system discharge. my battery discharged overnight, i wanted it to remain as backup and switch to grid when the sun goes out..
@YorkshireAutomation
@YorkshireAutomation 5 ай бұрын
Force discharge is when the lux will just discharge at max rate (unless reduced in settings) irrespective of the load so useful if you have export tariff. System discharge will only discharge what the house needs giving zero export. If you want to keep the batteries topped up in evening them use charge priority for those hours OR set up a charging schedule for those hours but keep %level to a low level so it doesn't use grid to charge up.
@FIBAROofficial
@FIBAROofficial 5 ай бұрын
While this is an interesting video in terms of presented knowledge, we would like to officially state that this kind of access is not recommended. It can decrease security level of your system and could give unauthorized people open access to your Home Center. The cloud service works as a gatekeeper and uses data assigned to a specific cloud account. It is not the matter of how easy or difficult it would be for a person to access your system, but rather a fact that the presented solution makes it significantly more possible.
@YorkshireAutomation
@YorkshireAutomation 5 ай бұрын
Hi thanks for your comments. As stated in the video there are risks associated with this but a couple of clients wanted access without cloud due to issues. so this video was made as a guide for them. i recommend that only those who know what they are doing to use this guide.
@storm_shadows
@storm_shadows 5 ай бұрын
Good video Is the code still available somewhere
@YorkshireAutomation
@YorkshireAutomation 5 ай бұрын
www.yorkshireautomation.uk/product-page/remotec-zrc90-lua-code is the webshop item. Just visit and download for £5!
@JasperWaale
@JasperWaale 6 ай бұрын
Oh, do you have to go to each device and uncheck? I have just got a hc3 and Aroyec Gen5 power meter, and its not only listed as double the devices I have and I figure have to go to each and hide it? but see has 2 core master device why dont the " slave" follow that settings also for the events stuff ?
@YorkshireAutomation
@YorkshireAutomation 6 ай бұрын
I actually don't use the energy panel but yes I would have had to uncheck each device and use the aeotec only. Also the as I have the 3 phase version I got 4 sets of devices. The 1st set is all 3 added together so I just hid them. Then the other 3 sets I kept the power only visible and hid the others
@JasperWaale
@JasperWaale 6 ай бұрын
wondering how you monitor house power use
@YorkshireAutomation
@YorkshireAutomation 6 ай бұрын
I have the Aeotec HEM gen5 meter. I have the 3 phase version. So 3 clamps to measure the House Consumption, Grid Import, and Solar Production. As long as you have a separate fuse box for house and solar then we can differentiate.
@justbrowsing7565
@justbrowsing7565 6 ай бұрын
I currently have two Pylontech US5000. I am going to add another two. What settings do I need to change in the Lux Power app to add these?
@YorkshireAutomation
@YorkshireAutomation 6 ай бұрын
there are no settings in the app that need chagning. Once you have added the batteries and adjusted the dip switch settings on the master battery and slave batteries this is automatically picked up. Speak to your Pylontech supplier/installer re the dip settings
@justbrowsing7565
@justbrowsing7565 6 ай бұрын
@YorkshireAutomation thanks. Currently on my batteries they're both set to all be up.i assumed the new two I put to be up also? So they're all up?
@YorkshireAutomation
@YorkshireAutomation 6 ай бұрын
i do a lot of greenlinx batteries and not Pylontech - theres a setting on the master to let it know how many slaves are connected and also ID of each battery. I think its on a dial with some numbers on it that you have to adjust - sorry but cant help more on that as i havent done Pylontech
@justbrowsing7565
@justbrowsing7565 6 ай бұрын
@YorkshireAutomation ok thank you very much I will have a read of the manual
@JavierRojasOrtega-h7y
@JavierRojasOrtega-h7y 7 ай бұрын
The motion sensor is blinking red. I initialized it and uninstalled it from the home center. I tried putting it in listening mode, and it stayed solid blue without blinking. In the end, I couldn't add it again. Do you know why it behaves this way?
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
Hi you need to exclude it. So put your controller in Exclusion mode and triple click the B button that should reset the sensor. Any controller can reset the sensor. once done just add it back in.
@JavierRojasOrtega-h7y
@JavierRojasOrtega-h7y 7 ай бұрын
@@YorkshireAutomation Thank you for the prompt response. I've already done that; the sensor is no longer in the home center, but it still maintains the slow red blinking.
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
possibly battery needs replacing? Also is the home centre and motion sensor in the same zwave frequency? if all is ok then more than likely the motion sensor has become faulty
@JavierRojasOrtega-h7y
@JavierRojasOrtega-h7y 7 ай бұрын
@@YorkshireAutomation Thank you for responding. Changing the battery was one of the first things I did. The sensor had been working fine for a while. Most likely, the device is damaged. Thank you for your response and assistance. Do you have an email or contact number?
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
Hi. [email protected] Mobile/Whastaapp is +447946591533 thanks
@robindraycott7844
@robindraycott7844 7 ай бұрын
Might be better if you don't have someone shredding bags of crisps in the background..?
@laszlopecsy934
@laszlopecsy934 7 ай бұрын
It seems to be cool! Thanks for your video! Could you provide the scene settings for heating and cooling a zone?
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
It's individual so it depends what you have in your system. Generally Temp sensor to measure temp A thermostat to sync to climate panel. Then check if temp is below the setpoint. When below the temp then change variable for that room. Then another scene to check all variables before turning the boiler switch on or off in case of heating or activate the AC
@laszlopecsy934
@laszlopecsy934 7 ай бұрын
@@YorkshireAutomation Thanks a lot, it helps me! I have almost the same system as yours just with fewer zones (and currently without any air conditioning) :)
@darrencareford3003
@darrencareford3003 7 ай бұрын
Hi, trying to follow your video to achieve the same, could you clarify a few things for me? The COM connects to int1 yellow cable? NO connects to Blue GND, does it matter which Blue GND as the implant has two? Thanks in advance for any help.
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
Doesn't matter which blue as they both the same. They have supplied 2 lots so we don't have to do ourselves
@neilp7024
@neilp7024 7 ай бұрын
HI thanks for the video - i have just had the Lux lxp3600acs and 2 x 3.2 kw batteries by green link (home ess-lv- 3.2 k) installed the lag on solar production reading via this app is woeful and tbh i`m really dissapointed with it !! just wondering if there is a way of getting a live reading from the inverter etc via the app ....i have another system that is far better (owl) and this is pretty much live...i`d say a lag of 3 seconds ...i have used the owl system to monitor my solar for the last 7 years and i thought this app would be far superior but sadly its not...anyway once again thanks for posting this video as its far better than the ones made by lux.Oh btw i i have used the refresh button on the app and it does work but wondered if there is a way to use live?
@samgirt7459
@samgirt7459 7 ай бұрын
Hi - Is it possible to have a lower rate of charge when using the grid over night but maintain full charge speed during the day? I've tried amending the grid charge option but noticed my system was also limiting my solar charging during the day!
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
Yes, only adjust the %charge rate inside the AC CHarge Time area. that will then adjust only grid charging and not solar charging
@samgirt7459
@samgirt7459 7 ай бұрын
Ah I'm using the app and I don't have that option. It saves 'Grid charge rate' and 'AC charge level' as my options. I'll try to see if I can log into the browser
@samgirt7459
@samgirt7459 7 ай бұрын
I checked on the website and its actually the same setting but with a different name. When I adjust it for some reason it was still limiting my charging through the day today from the panels.
@YorkshireAutomation
@YorkshireAutomation 7 ай бұрын
@@samgirt7459 Under Charge settings SYSTEM CHARGE POWER RATE (%) - Keep at 100% under the AC CHARGE thats separate
@samgirt7459
@samgirt7459 7 ай бұрын
@YorkshireAutomation Yeah that's what it's set to. It charges overnight at 50% rate fine, then today I noticed I was exporting half the power generation and the limit was also impacting my solar charging. I'll check again tomorrow. Maybe it was lagging a bit and I didnt give it chance to amend itself while I was testing
@deanharrysmith718
@deanharrysmith718 8 ай бұрын
Great Video, I do have a quick question. I am on a Luxpower hybrid 8-10K inverter with 2 x 10Kw Hanchu Batteries, I am on Octopus Flux and with flux I have setup the batteries in the inverter config to charge them between 2am and 5am as it's really cheap. Is there a reason why when the batteries get fully charged say approx 4am the inverter does not swap over to batteries but keeps pulling current from the grid right up to 5am and then swaps onto batteries.
@YorkshireAutomation
@YorkshireAutomation 8 ай бұрын
That's because you have specified to charge them from.2am to 5am and so they will remain in charge mode only. They cannot work in both modes simultaneously. If you know that they regularly get to 100% by 4am then amend them charging schedule to 2am.to 4am instead .
@user-shandyman
@user-shandyman 8 ай бұрын
Thanks for the explanation. Very helpful. I currently don’t have solar but am considering this. The company that has quoted me have no knowledge of Lux inverters. I have 2 squirrel pods. To add solar to charge my batteries i understand we need to add a CT clamp on the primary Lux inverter that sees the power on the live of the PV inverter. The solar installer is thinking the CT clamp needs an Eastron SDM120CT. Is this correct?
@YorkshireAutomation
@YorkshireAutomation 8 ай бұрын
Hi No it's a standard CT clamp similar to the one that you already have that is monitoring the grid. You will then only need a PV string inverter and not a hybrid inverter. If unsure give me a call for a chat on 07946 591533. Thanks
@Zangettsu_ZA
@Zangettsu_ZA 8 ай бұрын
We've installed a LuxPower hybrid solar inverter in our security estate in South Africa due to our country not having electricity for 12 hours of the day from the grid. At home I have a Victron system whereby I can just set the SOC to say 40% and the system will use the battery power at night when the sun is down and discharge to that setting before the grid is allowed to be used. Should the grid be out during Loadshedding (rolling blackouts) the batteries can dip below 40%. This is simple. But I have not yet figured out how to get this to work on the LuxPower inverter. The grid was out for 2 hours tonight and the battery discharged from 100% to 95% in that time. Now the battery remains at 95% while it is using grid power. There is enough battery capacity for our estate's security systems to be up all the time on the battery, after which the battery will recharge via solar again starting in the morning. Does anyone know how to set the LuxPower inverter to operate as with my Victron described above?
@YorkshireAutomation
@YorkshireAutomation 8 ай бұрын
i believe that in order to get the Lux to behave in the off-grid format needs your installer/distributor to change some settings for it to do that. As far as i know the defaut setting is as grif-tied
@Zangettsu_ZA
@Zangettsu_ZA 8 ай бұрын
@@YorkshireAutomation Ah thanks. I actually managed to figure it out. The interface seems a bit different than in your videos. On our inverter's maintenance page you can now set the Charge to take place within Timers, like it used to be, or set it to a certain SOC, or in fact, a combination of both. The first evening with the new settings the batteries reached their SOC setting at around 2 am, however the grid was off between 2am and 6am. So unfortunately the battery depleted and our security to our estate went dark. I then tweaked the settings again and last night it worked. When the grid came back around 6am there was still 50% of the battery left. And shortly after the sun was out and started charging the battery. So, it seems like there was a firmware upgrade which added the SOC setpoint, which in my opinion works 100% better than timers. Especially if you have an unstable grid like us where your power can go off without any notice.
@RossFawdington
@RossFawdington 8 ай бұрын
@YorkshireAutomation this was genuinely a really helpful video and much better than the manufacturers literature and efforts. Perhaps a silly question but what does "Power Backup Enable" do? Is it possible to configure the system to run the house during the power cut? Or can you only wire a socket on to the battery for smaller items to use?
@YorkshireAutomation
@YorkshireAutomation 8 ай бұрын
thanks for your comments. the system can run the house when there is a power cut but it has to be connected to the EPS outoput port of the Lux. You would need an electrician to wire in and make sure it complies with the electical regulations. Thanks
@RossFawdington
@RossFawdington 8 ай бұрын
I think I read it couldn't power the house unless there was a gateway or something to stop electricity going the wrong way into the grid. Does the lux Inverter work as a gateway? I suspect it doesn't and the EPS outlet will only power some sockets and can't be connected to the whole house. Nonetheless, many thanks for your help!
@YorkshireAutomation
@YorkshireAutomation 8 ай бұрын
@@RossFawdington the eps is connected indepently from the existing house. so the circuits are wired into a consumer unit directly fed from the EPS port. it has nothing to do with the grid. When grid is active then power is bypassed thruogh charge controller and into eps. when no grid then power is supplied via batteries. at no point is there a back-feed into the grid
@tomasjacko9534
@tomasjacko9534 8 ай бұрын
Hello, I would like to do scene but it doesnt work as I want. I want scene in my bathroom where: Between 10:00 pm and 6:00 am is by detected motion light turned on only to 5% This works for me. But in the other times, i want it to reset settinings of brithness back to 100% because when I turned on light manually by switch, it is still only on 5%. Can you help how to reset in these other times light back to 100%?
@YorkshireAutomation
@YorkshireAutomation 8 ай бұрын
Hi best to send me an email and we can book an online session
@tomasjacko9534
@tomasjacko9534 8 ай бұрын
Done. Please reply@@YorkshireAutomation
@mirk4work2
@mirk4work2 9 ай бұрын
What does S O C mean?
@YorkshireAutomation
@YorkshireAutomation 9 ай бұрын
State of Charge
@nguyenminhvu5947
@nguyenminhvu5947 9 ай бұрын
webshop free?
@YorkshireAutomation
@YorkshireAutomation 9 ай бұрын
There is nothing to buy for this. This is just free advice
@GracesterTime
@GracesterTime 9 ай бұрын
Mine doesnt work , i unfortunately update to beta version and now i have been trying to update to the newer version but still doesnt work. 🥲 any idea?
@YorkshireAutomation
@YorkshireAutomation 9 ай бұрын
​@GracesterTime you will have to download the firmware manually and use the recovery process to update to latest firmware. There is a post on this on the main fibaro forums
@GracesterTime
@GracesterTime 9 ай бұрын
Thank you so much! I succesfully updated the software. Now i just need to find out why all my devices loose connections. I tried to re conect but not it says “ transfered failed’” sorry i have many questions 😅 do you have any idea on how i can connect my devices back?
@YorkshireAutomation
@YorkshireAutomation 9 ай бұрын
@@GracesterTime send me an email and will discuss further [email protected]
@Veranda4M
@Veranda4M 10 ай бұрын
can you help me to add some devices into my hc3?
@YorkshireAutomation
@YorkshireAutomation 9 ай бұрын
Hi Yes. Just contact me via email on [email protected]
@johnjameson4956
@johnjameson4956 10 ай бұрын
Why does this need an app? You can do it easily enough with a block scene, don't even need LUA.
@YorkshireAutomation
@YorkshireAutomation 10 ай бұрын
it was a request from a client who wanted to be able to amend the temps from the phone. but in block scene as the temp is read and goes above the max temp OR if falls below the min temp the system will keep sending push notificaions to you. This QA only sends a single notification until it switches to the opposite
@johnjameson4956
@johnjameson4956 10 ай бұрын
Ah, fair enough. In my application the low temp warning will relate to a probable boiler failure so I'm not averse to multiple warnings.
@sokusziu
@sokusziu 10 ай бұрын
Many thanks for this informative video. We have just added another 3 Pylontech batteries to our LuxPower Invertor. What do we have to do to see these on the app please?
@YorkshireAutomation
@YorkshireAutomation 10 ай бұрын
They will automatically appear on the app provided they have been configured and connected correctly to your existing setup.
@sokusziu
@sokusziu 10 ай бұрын
@@YorkshireAutomation Many thanks for your quick reply! It's hard to tell from the app as it doesn't show the amount of charge in kWh just W (which says 30W) and 50.0Vdc and I haven't a clue what this means!
@sokusziu
@sokusziu 10 ай бұрын
Everything seems to be working ok - all lights on and no error message
@YorkshireAutomation
@YorkshireAutomation 10 ай бұрын
@sokusziu have you waited for at least 5 mins for the server to update? Also has the master been set to the new number of batteries? Have the slave batteries also been set?
@sokusziu
@sokusziu 10 ай бұрын
@@YorkshireAutomation yes ir's been about an hour. How do I change the master (what/where is the master? On the app?) I don't know what you mean by slave batteries, sorry!
@BoBrondum
@BoBrondum 10 ай бұрын
I can highly recommend this QuickApp (QA) and the ClickSend Service that sends SMS in case of an Alarm or other trigger. However, I caution using to long an "Id". In this case “myHC3” is used and that works fine. Configuring a lengthy "Id" gave me problems. Initially I had configured the “Id” with a rather long name and did not receive any messages. I have no idea what the limit is. Note: SMS are received almost without a reference to the Prefix. For Denmark I can use 0045, +45 or no Prefix at all in front f my number and still recieve messages.
@mortexist
@mortexist 11 ай бұрын
Hi, thanks for the video. I have a Lux system installed with a Lux 6000 hybrid inverter and a Greenlinkx battery. Based on the specs of the inverter it seems that it could be fitted with an automation so that if the grid power gets down the solar system can disengage the grid and continue to feed the house and function from solar and battery alone - as long as there is enough power generated or available in the batteries . However, the installer said he cannot fit it that way. Do you know if there is any after market option to make it this way?
@YorkshireAutomation
@YorkshireAutomation 11 ай бұрын
He is correct. The system does have EPS mode but they will have to re-wire existing house circuits through the hybrid inverter and also make provision for an external earth rod too.
@mortexist
@mortexist 11 ай бұрын
@@YorkshireAutomation Thanks. I suspected that. They don't know how to. I have an idea, but I am not an authorized electrician. Would this modification be something that you would do, or be interested to take on a contract ?
@YorkshireAutomation
@YorkshireAutomation 11 ай бұрын
@@mortexist please contact me via email or call 07946591533 or [email protected]
@theoccupier675
@theoccupier675 11 ай бұрын
Hi, is there a way to set the start % for charging, as during the spring and summer months my batteries will go through the night and start charging via solar in the morning. So if the battery percentage was below 40% the inverter could charge them to 70%, thanks
@YorkshireAutomation
@YorkshireAutomation 11 ай бұрын
as far as i know the system can only be set to charge based on time and then it will check percentage. So you could set the charge level to 70% and set a time period for tfor the morning. This would mean taht even if it was at 69% it would charge for 1%. During that charge times you have set would mean that discharge is disabled. I think a third party integration would be needed for what you would like to do.