Can it be completed without DHW at all? Mine gives me error code f7 no DHW connected constantly and it’s annoying. I have it for heat only as I have a heat pump water heater.
@iceman797517 күн бұрын
Interesting presentation ,thanks for posting.
@laloramirezmusic883924 күн бұрын
Where do I have to connect wires
@Super64heavyАй бұрын
Great instructive video. Thx
@SonicSouzАй бұрын
It doesnt get last the wifi pairing. My phone connects but the app cant see it
@TheUK332 ай бұрын
How do you turn heating on or off via app?
@TheUK332 ай бұрын
How do I turn heating up or down via app ?
@TheUK332 ай бұрын
How do you turn on or off heating via app? Or how do you control heating via app? If I want turn heating up or down?
@bach8582 ай бұрын
I can’t believe we call b2hb as our legacy product now. 😢
@alptekgul81242 ай бұрын
I keep getting E12 code. Anybody with a definite solution?
@ViessmannClimateSolutionsNA2 ай бұрын
Our Fault Code Checker advises the following: A number of TCUs were manufactured with firmware that contains an invalid certificate. Because the TCU has an invalid certificate, the connection to the Viessmann server is rejected. Instead, it is directed to a recovery server which tells the TCU to update its firmware. This process can take 60 to 90 minutes. Once updated, the TCU can connect to the Viessmann server. However, the registration process has already timed-out, and this results in an E10 or E12 error. After receiving an E10 or E12 error in ViCare, the user will need to wait a minimum of 90 minutes while the firmware on the TCU gets updated. After this time, the user can try registering the boiler in ViCare again, and the process should work.
@lpxc20053 ай бұрын
What does the solid red LED status mean? How to solve this situation?
@NaturesElementRI4 ай бұрын
thank you for the great combustion test video jason
@arditbuzi9084 ай бұрын
Hi there, I am working on a Vitogate 300 and when I want to add the points on the database for the BMS System it takes too much time to discover the points, or it times out and does not discover the points at all. Any explanation?
@StevePierceYpsi4 ай бұрын
The Audio is so bad on this video that I transcribed it so it is easier to understand. The audio starts around 30 seconds and ends at about 1 min 30 sec. Hi, my name is Moises Delgado, and I'm with Veissmann Manufacturing. Today, we'll be discussing a few issues you might encounter in your Veissmann boiler. In this example, we're going to use a zero D (0D) fault. Oftentimes, you may encounter your boiler in an idle state, and you decide to press the reset button, and all of a sudden you'll get a fault that says zero D (0D). A zero D fault just means that the reset button was pressed out of sequence. It's really more of a nuisance fault, but I'll show you how to clear it today. The first thing we're going to do is we're going to open the trap door area. We're going to select the fault search with A. This time it will display the fault, zero D (0D). I will acknowledge the fault zero D as well. Then close the trap door, and press the reset once. (He presses and holds the reset button for about 1 second before releasing) Within a few minutes, the boiler should fire up again, and you have a green light indicating the flame.
@JanosHoyos4 ай бұрын
Excellent
@audenandersen15495 ай бұрын
How come tech support for viessman can’t tell me what the voltage is that goes from the board to gas valve . Vitomens 100-w
@nebbrooklyn59665 ай бұрын
Great video!
@cabottaxi6 ай бұрын
I have a Viessman 100 combi installed 1 year ago. It works fine from the ViCare app but won't accept being controlled by a third party wireless room thermostat ( HONEYWELL T3R) . Can't figure how to switch it on at the boiler either so left frustrated by it all. Original company that fitted it left scratching their heads.
@johnhunter41816 ай бұрын
When I search ViCare in the App Store, it doesn't find anything useful.
@vitaliypro84416 ай бұрын
What’s the price range?
@dand55937 ай бұрын
Great, there is a chance to find this using celsius scale for temperatures? Thanks
@youngmincha29167 ай бұрын
Wife password has been changed, Not connected wifi. I want to connect again, how can I do?
@brahim212618 ай бұрын
What is f8 please on this boiler?
@Wspsportsfan8 ай бұрын
can this be used as an AHU for a Carrier Aquasnap Chiller?
@varugheesevilail61938 ай бұрын
I have recharged my connection along with other 2 connections one sor my wife and other for my sonfor Rs. 99 each. Our connection using for several years. Now your message came that I will not receive any email message. If not recharged for higher amount If so I will stop and cancell my 3 cellphone connection shortly
@chrishard76168 ай бұрын
You have confused current and voltage! You state to set meter to AC current then you are using it to measure AC voltage 🤷♂️🤦♂️ That is a fundamental error that could cause damage to things since if meter was set to current it will short circuit the item you probe across.
@00hounds8 ай бұрын
We had the house power cut off from hydro and when they powered house back on an hour later we tried starting the unit/ boiler and it started the info screen for about 2 seconds and then it tripped the breaker we tried to start again a bunch of times but just keeps tripping the breaker can u tell me what it could be and how to fix.pls n thx.
@NineCarGarage9 ай бұрын
I just installed an outside temp sensor but my B1KA doesn't have an option 15 on menu 12. It cycles from option 14 back to 0. Is this a firmware issue or is there another option that precludes option 15 from showing?
@ViessmannClimateSolutionsNA9 ай бұрын
Hello, to better assist you can you please provide us with your boiler serial number?
@C0R3659 ай бұрын
When you flush the debris with water towards the end where does the water and debris go? This part is not clear to me.
@Srnanek449 ай бұрын
Can you please advise why the one bar flame symbol is constantly shown on my boiler. I think my boiler hasnt switched off for over two months. It is constantly running on one bar flame symbol. Even after resetting it per your video instructions.
@ViessmannClimateSolutionsNA9 ай бұрын
Hello, would you please tell us exactly which boiler model you are working with?
@Srnanek449 ай бұрын
Hello, i have vitodens 111.
@ViessmannClimateSolutionsNA9 ай бұрын
I understand. This product is not available in North America. You will need to reach out to the country-specific account to get support.@@Srnanek44
@diqili15089 ай бұрын
Hello, what is the correct range for the vent pressure?
@ViessmannClimateSolutionsNA9 ай бұрын
To serve you better and provide the most suitable answer to your question, we kindly request that you connect with our Technical Service Department. By doing this, our team can ask some initial questions to get a clearer picture of your needs and provide a tailored solution for you. We're here to provide comprehensive support and look forward to assisting you further!
@timdevisser866710 ай бұрын
Finally 😀. Looking great.
@mikepadilla590510 ай бұрын
I’m curious when there is a call for heat from a thermostat does the cir pump come on or is that timed?
@skuter704910 ай бұрын
Why does the DHW show 2 dashes? I thought it would show the temp of the water like it does for the baseboard heat.
@bach85810 ай бұрын
Look at you, Viessmann US! Finally done. It is beautiful. Congrats! 🎉
@magallanthepenguin913210 ай бұрын
Why new flow switch died in 1 month? Had a spare thankfully
@brightwayhvac10 ай бұрын
I am currently have B1HE-85 to replace a WB1B model , the existing cpvc is 2" but the B1HE only comes with 3" flue connection , is there a 2" flue connection for B1HE-85 ? what is the part number of it ? thank you .
@ViessmannClimateSolutionsNA10 ай бұрын
Hello, thank you for reaching out. The part number you are looking for is 7494888 Coaxial Adaptor (CG) 80/125 to 60/100.
@GregCole-y2u10 ай бұрын
What happens if the sticker is not present on the boiler. Where do i find the 3 pcs of info required to fill the app questions manually
I have the 0b fault code occasionally. It happens mostly in the morning when the central heating needs to heat the place several degrees. Seems like switching to hot water is a trigger. Sometimes switching to hot water and back to central heating causes the 0b to show. Other times the fault code 0b is already there and switching to hot water makes it go away. When 0b shows, at all times hot water is available when i open a hot water tap. At all times the pump keeps running. It's just that on central heating the burner will not activate. Sometimes before the 0b shows i can hear the burner try to activate but fails, or the burner runs for 2 sec and stops, then 0b shows. A few times i saw when temperature drops below 50c the burner succeeds to activate and 0b is gone. Could you possibly give me some insights before i start troubleshooting?
@3pointedshr11 ай бұрын
Do you need a room thermostat as well or does the vi controller act as a thermostat?
@ViessmannClimateSolutionsNA10 ай бұрын
The 200 series can do so with circuits and has an option for room feedback. The 100 & 300 series uses a room thermostat.
@marconantel7735 Жыл бұрын
Is there a new part number for the up dated check valve? What are the symptoms of needing it?
@ViessmannClimateSolutionsNA Жыл бұрын
The part number for the updated check valve is 7890563. In limited cases, the original check valve may stick resulting in a no hot water condition.
@mfritz2419 Жыл бұрын
Same. I get the e12 error
@spyseeuk1367 Жыл бұрын
I'm actually looking to install the 4-pipe system
@spyseeuk1367 Жыл бұрын
Guys great vid can anyone find the equivalent for the U.K??? I'm obviously a u.k plumber and I can't find anything :-(
@ashleyneuschwanter4353 Жыл бұрын
We’re having difficulty connecting our new system. We are unable to pair to the boiler from the app. Any suggestion?
@jingyan90816 ай бұрын
I have the same issue. Do you have any solutions?
@aleksandardrakulovic9530 Жыл бұрын
How change contry?
@ViessmannClimateSolutionsNA10 ай бұрын
You would want to go to settings and then units and location to change the country.
@bach858 Жыл бұрын
Awesome! Looking forward to new larger sizes to appear soon.
@hobson3724 Жыл бұрын
Hi there. Thanks for sharing this valuable information. Do i need an extra pump for the indirect DHW tank? i am planning to install the B1HE 120 with a 80 gallon indirect tank. I see the boiler has an internal pump already. Do i need to install an additional pump on the Tank heating supply side? or i just connect them directly? The distance between the indirect tank and the boiler is less 4 feet. Thanks
@ViessmannClimateSolutionsNA10 ай бұрын
If you connect the indirect tank on the boiler side of the system (Upstream of the Low Loss Header), there is no additional pump required. Simply hook up the coil of the tank to the DHW connections fittings provided on the bottom of the boiler. the internal diverter valve will switch the flow from heating to DHW on a DHW call. You will need to either connect a DHW 10KNTC thermistor, or an aquastat between the tank and the boiler. We recommend the temperature sensor if possible. If you install the tank on the system side (Downstream of the low Loss header, you will need an additional pump. That pump can be connected to and operated by the boiler. The boiler will need to be recommissioned to add the tank if it was not set up for DHW initially.
@hobson372410 ай бұрын
Thanks for the reply!!@@ViessmannClimateSolutionsNA