@LiuPh
@LiuPh 19 күн бұрын
Thank you for the video. It is really clear and helpful. But in our lab, it is very strange that our GC-SCD gives decaying signals time by time. We tried to inject Sulfur standard gas and each time the peak area reduced by 2~3%. But if we let the instrument take a break for one hour, the signal rises in the next shot. Agilent Engineer came and replace the loop, valve and something else, but it has no change. We are still trying to solve the problem.
@hermon810
@hermon810 Ай бұрын
Voice quality is poor. Please try to address this for future presentations.
@agatapios4959
@agatapios4959 Ай бұрын
So helpful for my exam, thank you!!!
@amolsagulale4294
@amolsagulale4294 2 ай бұрын
very informative
@russellgu8y2447
@russellgu8y2447 2 ай бұрын
Very helpful thankyou
@benysmart1643
@benysmart1643 2 ай бұрын
Very interesting , thanks for sharing
@harishasnayak5249
@harishasnayak5249 2 ай бұрын
Good one
@Willow-id4gu
@Willow-id4gu 3 ай бұрын
thank you so much for sharing these webinars :)
@MariiaSlavhorodska
@MariiaSlavhorodska 5 ай бұрын
Thank you so much
@priyatoshdatta7733
@priyatoshdatta7733 6 ай бұрын
Nice presentation, high level demonstration of scientific principles on ms ms analytical technology.
@mattphillips538
@mattphillips538 7 ай бұрын
32:48
@sarvanks7711
@sarvanks7711 Жыл бұрын
Thanks. Can we able to predict the no of isomers present in the mixtures using the LCMS/MS
@Ccccccccccsssssssssss
@Ccccccccccsssssssssss 6 ай бұрын
It depends. Some isomers will react differently with HPLC column, and therefore will have different retention times. For example, a branched chain isomer will typically have less interaction with the packing of the column, and will elute early, while a straight chain isomer will tend to have more interaction with the column and will elute later. In cases like this, you will see multiple peaks in a chromatogram, which each represent a different isomer. However, this is very dependent on the type of isomer (for example stereoisomers, or large molecules with isomers that are very similar in structure will be difficult to separate) and also dependent on the relationship between the compound and the column, and the mechanism of interaction between the two. I hope this is helpful.
@sarvanks7711
@sarvanks7711 6 ай бұрын
@@Ccccccccccsssssssssss Thankk you sir
@Harshavardhan-xy6xo
@Harshavardhan-xy6xo Жыл бұрын
Impressive … perfectly covered all the points.. Thanks for the detailed explanation
@abusupyanadiyev7067
@abusupyanadiyev7067 Жыл бұрын
Good
@AmitKumar-ee4sc
@AmitKumar-ee4sc Жыл бұрын
Nicely presented😀
@Chimpunk729
@Chimpunk729 Жыл бұрын
Not this brand user but its general so its important
@achyutjagdhane9683
@achyutjagdhane9683 Жыл бұрын
very nice , thanks a lot for such a guidance
@achyutjagdhane9683
@achyutjagdhane9683 Жыл бұрын
thanks sir , i got a crystal clear clarity on subject , very nice explanation , thanks a lot for beautiful guidance .
@ramonverduzco3522
@ramonverduzco3522 Жыл бұрын
Cleaning source 43:00 great video. thanks!
@DP-vm2dd
@DP-vm2dd Жыл бұрын
Thanks!!!!!
@mingtor89
@mingtor89 2 жыл бұрын
I currently work for ThermoFisher scientific in the UK but I am studying my Masters degree in environmental assessment and control. This video was helpful in my paper on methods of testing drinking water for fluoride contamination.