This is not good because 2½ inch pipe is not fixing essy is to much problem for treading
@RobloxFireSecurityCorp.-st3cl6 ай бұрын
Bro that panel came out in 1992 it is not made anymore
@RickyTricky907 ай бұрын
Thieves thank you for making this widely available for their arsenal of ways to rob a business.
@lewisg17369 ай бұрын
Eye protection.
@cristiancolome9210 ай бұрын
Man. You're the best. I hope you're doing greate!
@sebastiannielsen Жыл бұрын
Slightly wrong. The difference between supervisory and trouble, is that supervisory is a kind of "alarm" condition. That means you hook something up to a zone, and tell this zone is supervisory. If there is a problem with a detector on the supervisory zone, you will get a trouble. It isn't limited to power, it can be all troubles. Think like this: If you get a open loop on a supervisory zone, it will react with a trouble. However, if a supervisory device trips, it will short the loop, giving a supervisory signal. So basically, if you wire a pressure switch to a fire alarm zone, and tell the system the zone is a supervisory, then you will get a supervisory alarm. Change that zone to a "fire" zone, and the same pressure switch will pull a real fire alarm. A trouble means theres something wrong, for example, if that pressure switch breaks and become open loop totally, then you will get a trouble signal instead. In burgular alarm terms, "supervisory" is same as configuring a zone in your burgular alarm as "Temperature alarm". This zone, if its trips, will cause a temperature alarm to be sent to dispatch centre, and they call you and say, for example if you named your zone "Fridge", they will say "hey your fridge has some problems so its not cold enough". However, if that zone is shorted or opened, ergo having the wrong resistors, it will still react with a "Tamper Alarm" and sound the alarm. (which is same as "Trouble" on a FACP).
@wlady4000 Жыл бұрын
Awesome Thank you
@BryantCoffey-v2m Жыл бұрын
This is not a pressure reducing valve, it is a pressure restricting valve.
@ivanwaskahatj Жыл бұрын
Hutry am burnin
@bridgett1971 Жыл бұрын
How do you clear a supervisory
@captainchris2016 Жыл бұрын
By returning the supervised equipment like a sprinkler tamper to normal
@sayeedmcburnie97963 жыл бұрын
Good stuff man ..you just saved me a lot of time..I literally just installed six of these now I’ll be setting the pressure that’s required and going home early on this nice Saturday..Thanks again local 483..
@ibeattheleaves50054 жыл бұрын
How well does this work when a door closer is attached at the top?
@Bannrus4 жыл бұрын
Could you use the test header to fill your apparatus by accessing the storage tanks of a building? Like in the event of emergency where the water supply was cut off to other parts of the city.
@silverstrings55694 жыл бұрын
Non-destructive entry is a fantastic first option, as it allows you the potential for more flow control. Thanks for the video!
@pavel50335 жыл бұрын
Thanks.
@rehanzahid96005 жыл бұрын
Nicely explained sir ...can u guide me about how repeater panels connect with a network card to the main control panel to next repeater panel..
@angellawless74135 жыл бұрын
Would this method still work on a newly installed (no dirt build up) store front door that was exactly the same?
@jeremywilliams71915 жыл бұрын
Angel, it is possible it would work on a newly installed door. However, if it was installed correctly it will be difficult. When a door installer is really good, the door will sit tight in the hinges making this technique difficult.
@angellawless74135 жыл бұрын
Jeremy Williams Yeah, that makes sense. Thanks for the quick response. Stay safe out there.