TechTime: The Reversing Valve
10:57
2 жыл бұрын
TechTime: Thermistors and Sensors
10:31
Geothermal Service Procedures
56:57
3 жыл бұрын
HE/HR Calculations
53:07
3 жыл бұрын
Пікірлер
@kolponajosna
@kolponajosna 21 сағат бұрын
Lee Dorothy Young Joseph Martin Kenneth
@WhyetJo-q8p
@WhyetJo-q8p 16 күн бұрын
Corbin Heights
@rav4hybrid
@rav4hybrid Ай бұрын
My tetco geothermal has a 4 pin molex going to the ecm board. Is this a DCV signaled board to module? Diagnostics for a 4 pin available? I get 12v DC from Red to other 3 pins. What should I be measuring?
@NancyDell-m6y
@NancyDell-m6y Ай бұрын
Martin Gary Thompson Kenneth Johnson David
@kenthomas4668
@kenthomas4668 Ай бұрын
Walk in the door, go to thermostat and turn fan to on, if you hear a blower you know you have 24v, 110v, red wire from tstat is good, green wire is, fan relay on board is good and fan motor works. If nothing happens flip the tstat to heat, if heat goes then 24v is present and white wire is good, red wire is good, you have both 24v and 110v also. No need for a multi tester yet. NOW got o furnace and start testing, much much faster.
@dmills13F
@dmills13F 2 ай бұрын
Good demonstration of nitrogen purge. Terrible demonstration of brazing. Look at the cut open coupons, not a drop of filler material made it to the end of the pipes.
@robc7019
@robc7019 2 ай бұрын
One of my AC units quit working. I troubleshot the blower motor and I’m having the back and forth rocking but it never starts. All my voltages are good. I ohmed out the blower and am getting 11 ohms at each wire. I didn’t ohm to ground. In the video he mentioned replacing the blower motor but doesn’t specify whether you should replace the blower only or the entire assembly, motor and ecm. Does anyone know what I should do?
@rav4hybrid
@rav4hybrid Ай бұрын
The windings are good so the motor itself is fine if none measure ohms to ground.
@nimrodburo5507
@nimrodburo5507 3 ай бұрын
Sir John how are you, I'm Nimrod from Geo Service here in Cayman. I checked a split type unit geothermal AC and when the solenoid valve of the scroll compressor for the 2nd stage works, the 24volts that supplying the magnetic contactor coil will gone. What's the cause of this problem Sir John? Thank you and God bless🙏
@FatFingers1982
@FatFingers1982 3 ай бұрын
Hey there, I have a water furnace open loop w cupro nickel exchanger. I haven't done any maintenance in almost 10 years, been working great, but now seems to be struggling to keep up. What is the best chemical you recommend for descale that is cupro nickel safe? (we have a water softener, the water in the top of toilet tanks are usually reddish too). Thanks so much for the informative videos!!
@miguelescobedo3967
@miguelescobedo3967 4 ай бұрын
How can you tell if the solenoid plug is bad
@RobertTuck-vo8cw
@RobertTuck-vo8cw 4 ай бұрын
It does not have ECM board or module diagnostics.
@emmanuelmartin3999
@emmanuelmartin3999 5 ай бұрын
where to buy that fins
@johnwhite2576
@johnwhite2576 5 ай бұрын
If you have a full inverter variable compressor and blower system, wont they automatically start up slowly ? In which case the defender is moot ?
@garypoplin4599
@garypoplin4599 6 ай бұрын
7:46 - I wasted my time so you don’t have to. Click this link to jump to the beginning of the content. This presentation begins here after 7 minutes and 45 seconds of silence.
@hediervarelamedina987
@hediervarelamedina987 6 ай бұрын
excellent video and explanation
@willadams538
@willadams538 7 ай бұрын
Thanks Entertech for the AV system we installed in our new shop . ODM out of Lansing Kansas
@waleneliyata1252
@waleneliyata1252 8 ай бұрын
This is amazing ❤❤
@waleneliyata1252
@waleneliyata1252 8 ай бұрын
❤❤❤❤
@DNR1982
@DNR1982 8 ай бұрын
GOOD JOB
@DNR1982
@DNR1982 8 ай бұрын
We had 5 ton geothermal system replaced approximately 10 years ago and less than one year later, had lightning strike, needed to replace you again… Due to unscrupulous contractor, I am doubtful this was done correctly, and almost certain that system was never flushed at replacement either time any idea on who to call, how much it should cost and if in fact, there is a way to tell what my antifreeze level is currently with the status of the water without having this service done?
@DNR1982
@DNR1982 8 ай бұрын
* Needed to replace UNIT… NOT “you” and what the status, NOT ‘with’ 😅
@HOLISTIQBUILD
@HOLISTIQBUILD 8 ай бұрын
Thanks for putting this up!
@raymonddharmadipraja3630
@raymonddharmadipraja3630 11 ай бұрын
Hey can you shoot me an email of the troubleshooting manual pdf? Thank you
@christianmontenegroaraya1888
@christianmontenegroaraya1888 11 ай бұрын
Thanks a lot for this great advice!
@MahendraKumar-xi5mz
@MahendraKumar-xi5mz Жыл бұрын
हिंदी मे वीडियो बनाए
@awfulaccident5957
@awfulaccident5957 Жыл бұрын
now this is my speed!
@robertwojtowicz933
@robertwojtowicz933 Жыл бұрын
Just don’t buy the piece of shit microchannel and you won’t have to repair it !
@kastenusa
@kastenusa Жыл бұрын
Can’t find this tool adapter anywhere
@EnertechGlobal
@EnertechGlobal Жыл бұрын
The part number is AGAMGH.
@mrrjtrevino
@mrrjtrevino Жыл бұрын
What about blow motor won’t turn off number 4
@kastenusa
@kastenusa Жыл бұрын
Can I disconnect power to water pump and see if Txv will maintain low side pressure? Thank you
@EnertechUniversity
@EnertechUniversity Жыл бұрын
No, as that will not tell us if the TXV is good or bad. Superheat & Subcooling readings or a "fire & ice" TXV bulb test will tell you if the TXV will not meter properly.
@kastenusa
@kastenusa Жыл бұрын
@@EnertechUniversity it will tell us if it bad or good. If txv is good if will maintain superheat. Because it his job. If txv is bad you will see it on low side of the gauge. Just don’t let your high side go above 400.
@graphene1487
@graphene1487 Жыл бұрын
What would cause system to suddenly blow hot/heated air when in cooling mode? Been having this recurring issue and don't know what to do. Please help😢
@MikeSmith246
@MikeSmith246 Жыл бұрын
hi, my ge ecm 2.3 1/2 hp motor is continuously running on a low speed, when we turn off the ac, it switches from normal speed to low speed and keeps running, any help would be appreciated.
@AliElectricDiY
@AliElectricDiY Жыл бұрын
kzbin.info/www/bejne/fXaof42uZdF3g9k
@juancarlostrejo6323
@juancarlostrejo6323 Жыл бұрын
Good video
@davidbrumbaugh3950
@davidbrumbaugh3950 Жыл бұрын
A squirrel cage blower is not a positive displacement type air pump. Ergo, it should not draw more current due to duct restriction, but should draw less as it is doing less work, moving less air. Put an ammeter on the blower motor and restrict its duct...see what happens.
@michaelpursell9445
@michaelpursell9445 Жыл бұрын
how often should the fluid be replaced?
@rodgraff1782
@rodgraff1782 Жыл бұрын
Before condemning a TXV, you have to check for a restriction upstream, like a plugged filter dryer. The valve needs solid liquid feeding the valve, and at least 100 lbs pressure differential across the valve. The method you used to test the valves operation my removing the bulb, and using hot and cold water is a good idea, and could save replacing a lot of expansion valves. I see a lot of techs not even look at the bulb, to see if it’s mounted correctly and tight. I always replaced the power heads on valves, by pumping the system down. You can tell if the bulb is bad just by pushing on the bellows once it is out. You’re right about the hunting. Usually caused by oversize valve, or improper mounting of the bulb.
@MrRerod
@MrRerod Жыл бұрын
After replacing the module thermister, a year later my main blower motor (GE 1/2 hp 08/22/00 CNO2 011DH7) is making a intermittent high pitched whine (g#5 note) when on first stage. I "think" it's related to the module, but not sure. Anyone?
@mbahcarrier1629
@mbahcarrier1629 Жыл бұрын
Thank you for the knowledge, success for "Enertech ....." ... Pekalongan, Central Java, Indonesia attended
@yawemmanuel4380
@yawemmanuel4380 Жыл бұрын
Cool undercut temperature for
@ozam35
@ozam35 Жыл бұрын
Did yoy give online course in brazing or you can call it wellding
@BelleRiverHeating
@BelleRiverHeating Жыл бұрын
What mechanical could be wrong if one of the symptoms is the amp draw on the compressor keeps rising steadily for about fifteen minutes and then it completely shuts off on overload? The refrigerant pressures seem to be stable, but low at appx. 48psi suction and 177 psi liquid being an R-22 unit.
@newstart49
@newstart49 Жыл бұрын
When done, flush the coil out with water- don't worry, just pull a vacuum for a week or so.~~~ I might use a soapy damp rag, but I'm NOT spraying the hole with water!! A dry carburetor cleaner pray might be better.?
@rodgraff1782
@rodgraff1782 Жыл бұрын
A good way is to hold a lit match at the exit point. Nitrogen will snuff out the flame if there is no oxygen present. A flow meter that is very sensitive, should be used instead of a regulator. It’s flow that is important, not pressure.
@dennisbrancato6121
@dennisbrancato6121 Жыл бұрын
I have a Nutone HVAC heat pump with a Copeland Scroll compressor. The problem is a loud buzz on startup and intermittently during the cycle. I am thinking it may be the compressor, but, not sure. Have replaced capacitor and checked wiring but still have the buzz at the compressor. Would hate to change compressor if its not bad. Any other causes for this buzz and what would cause the buzz within the compressor?
@trinito97
@trinito97 Жыл бұрын
How about when you get the leak in the middle of tube
@alfonsobenitez8574
@alfonsobenitez8574 2 жыл бұрын
I bought two electronic testers for the 16 pin and the the other X13. I just plug them to the 24 volt and if it runs we know the motor is good. Have to do some of the checking you reccomended here. Good job on the video.
@kenthomas4668
@kenthomas4668 Ай бұрын
Keep an old wire harness remove all wires except 1 and 3 and 12 and 15 and remove molex plug from one end. Now take the red and blue wires and connect to pins 1 and 3 and 12 and 15. You now have a go no go tester for free.
@haroldcouch4168
@haroldcouch4168 2 жыл бұрын
Does anyone ever answer questions in comments?Is 15amps on 2nd stage scroll 5t good?Unit says 25.6 RLA on nameplate.TIA.
@apisglider9
@apisglider9 2 жыл бұрын
4 motors in 11 years doesn't seem too reliable to me. Ecm motors are very sensitive to static pressure and voltage spikes