Пікірлер
@marianosalazar1270
@marianosalazar1270 23 күн бұрын
I want to know if this type of breaking will stop a saw from continuing spinning from the inertia. it big saw 25" diameter. 7hp motor, thank you in advances.
@danielardelian2
@danielardelian2 2 ай бұрын
The Fluke "123" does not have a low-pass filter but it does have a "Vpwm" measurement option exactly for this purpose (to measure PWM-generated voltage). The newer "123B", with color display, has a 10 KHz low-pass filter that can be enabled from the menu.
@nayrbsworld3048
@nayrbsworld3048 Жыл бұрын
hi i need an advice. im learning now AB plc simulator and planning to buy a real.PLC to simulate PID. What do think is the best to buy with a limited budget but i can use this to practice PLC programming.
@tonys9391
@tonys9391 Жыл бұрын
How do you connect the scope probe to the motor? Reference lead to the ground or to the phase?
@durwoodking9696
@durwoodking9696 10 ай бұрын
Phase to phase. Fluke Scope meter 123 can handle 460 vac
@michaelcostello6991
@michaelcostello6991 Жыл бұрын
Does this mean the laptop does not need an ethernet card ? That external device works ?
@gar232010
@gar232010 Жыл бұрын
Excellent example. Could you share what settings you move in the vfd
@durwoodking9696
@durwoodking9696 Жыл бұрын
To turn on the Dynamic brake feature, set parameters: A437= 1 for Dynamic brake resistor, normal. A434= .5 seconds DC brake time. ( Time that the DC voltage is applied to the AC motor, not much is needed. PO42 = Deceleration set to approx .1 sec for fast stopping. That's all it takes 😀, let me know if any other questions ! Have a blessed day ! Durwood King
@durwoodking9696
@durwoodking9696 Жыл бұрын
Sorry for delay responding, I haven't been checking KZbin lately. To turn on the Dynamic brake feature, set parameters: A437= 1 for Dynamic brake resistor, normal. A434= .5 seconds DC brake time. ( Time that the DC voltage is applied to the AC motor, not much is needed. PO42 = Deceleration set to approx .1 sec for fast stopping. That's all it takes 😀, let me know if any other questions ! Have a blessed day ! Durwood King
@gar232010
@gar232010 Жыл бұрын
@@durwoodking9696 thank you so much for sharing
@durwoodking9696
@durwoodking9696 Жыл бұрын
@@gar232010 Do you work in a plant in the USA ?
@gar232010
@gar232010 Жыл бұрын
@@durwoodking9696 yes, sir,
@tobiasmaier2884
@tobiasmaier2884 2 жыл бұрын
Thank you for taking the time to upload this to KZbin. Your experience and patience were very helpful.
@xubairahmed951
@xubairahmed951 2 жыл бұрын
Thanks for the video. I am trying to configure powerflex 755 but the problem I am facing is when the motor runs up to the full speed (set on the HMI) the external brake resistor starts making noice. I have never seen this issue with any other drive.
@durwoodking9696
@durwoodking9696 2 жыл бұрын
Hello Zubair 🤠, was the VFD and brake resistor doing fine and suddenly started this problem with existing wiring and programming ? Durwood King 🤠
@durwoodking9696
@durwoodking9696 2 жыл бұрын
I see you are trying to configure the 755. What parameters did you change ?
@durwoodking9696
@durwoodking9696 2 жыл бұрын
WHAT TERMINALS ARE YOU CONNECTING THE BRAKE RESISTOR TO ?? Sounds like a wiring issue... The brake resistor is supposed to be active in the circuit only when you stop the VFD, not when running.
@durwoodking9696
@durwoodking9696 Жыл бұрын
Sorry for delay responding, I haven't been checking KZbin lately. To turn on the Dynamic brake feature, set parameters: A437= 1 for Dynamic brake resistor, normal. A434= .5 seconds DC brake time. ( Time that the DC voltage is applied to the AC motor, not much is needed. PO42 = Deceleration set to approx .1 sec for fast stopping. That's all it takes 😀, let me know if any other questions ! Have a blessed day ! Durwood King
@nivendarsoo4575
@nivendarsoo4575 3 жыл бұрын
If i have RSLogix 5000 can i communicate with a PLC that has RS500?
@durwoodking9696
@durwoodking9696 3 жыл бұрын
You need RS Logix 500 software if you are communicating with any MicroLogix or SLC type PLC. RS Logix 5000 software (now Studio 5000) only works with Compact Logix and Control Logix PLCs. If you have more questions feel free to ask ! Have a great day, Durwood
@et.sachin
@et.sachin 3 жыл бұрын
Sir your video has a lot of information and it would be great if you could record these videos in portrait mode. Thanks
@iddrisurafiw1694
@iddrisurafiw1694 3 жыл бұрын
My Alley bradley smc flex is tripping on no load fault...#40 what exactly is the problem and how to troubleshoot it?
@jiewenmai
@jiewenmai 3 жыл бұрын
where can I get this data sheet?!