The actual demonstration of how this battery tester is used starts at 2:08. The rest must be meant for people who have never seen a battery....
@ArvindSinghSingh-qg3wl2 ай бұрын
Koun sa chamicel pauder use kerna hy
@MEGAclassroom2 ай бұрын
Bentonite mixed chemical clay compound
@GoluRwtt3 ай бұрын
Sir muje 12/10 ka board purchase krna hai Apke pas mil skta hai
@praveshkumar39945 ай бұрын
MAINE FLEX MACHINE KE LIYE ERTHING LAGWAYA HAI PAR USKA REGISTANCE BAHUTA JYADA AA RHA KAISE KAM KARU USE BAHUT KUCCH TRY KAR LIYA
@MEGAclassroom5 ай бұрын
Ek se jyada earthing kare, Earthing jyada gaherai par kare, electrode badi size ka use kare, chemical compound jyada use kare, earthing wire mota use kare, earthing wire me kam se kam joint kare.
@FarooqPSK7 ай бұрын
How much lightning voltage can this setup ground during storms.?
@ratnadeepdhar48167 ай бұрын
Very nice brother wire ka specification boliyega please. Waiting for your reply. Regards 🙏
@MEGAclassroom7 ай бұрын
10 sq. mm PVC coated copper wire
@ElectricINDIA_4708 ай бұрын
Please make full detailed video on it's topic please 🙏😊
@Bharathjain2410 ай бұрын
Ur Gmail id
@paplukailash Жыл бұрын
AP ka ph
@pareshbhai7917 Жыл бұрын
Sir plastic box me kon kon sizes me miltehe non module me
@MEGAclassroom Жыл бұрын
Plastic box module ke hisab se aate hai. 2 module, 4 module, 6, 8, 12 module etc.
@pradeeparya Жыл бұрын
Thank you bro.. 😊
@MEGAclassroom Жыл бұрын
Welcome 😊
@OLAMILEKANSI Жыл бұрын
We have three type of laboratory lay out ( open , bay , separate) which one is this
@jigarbiradi8643 Жыл бұрын
Or choti video banav 😂😂😂
@DineshKumar-en6ub Жыл бұрын
Board ka switch tedha set huwa hai bhai
@healingspell3887 Жыл бұрын
can i please have an hard copy of your work? the circuit of an hot and cold incandescent lamp
@atrivedi74 Жыл бұрын
Can it achieve < 0.5 ohm ? Video focusses on the procedure only and doesn't not mention the end results.
@Raju12-p9t Жыл бұрын
12x 18 mrp
@AnsariBijliwalaofficial Жыл бұрын
Bhai Earth pipe ka raper to nikal dete bhai proper work nhi karega
@mowaisshahid Жыл бұрын
Some people say to make a bore at 80-100ft. Some say untill the water level. Some say untill the wet sand level... I am confused, please guide me the depth of earthing pit... Thanks
@MEGAclassroom Жыл бұрын
As per standard 4 meter is enough but when soil is not wet enough then you should make deep bore. Our last goal must be to achieve earthing resistance 5 ohm or less. Nowadays earth compound material for earthing is available which helps to keep earthing pit wet for a long time. Also we provide water pouring facility to keep it wet.
@aliaction8239 Жыл бұрын
Solutions for Rock soil??
@MEGAclassroom10 ай бұрын
Use Earth compound & multiple earthing/ earthing grid.
@ayushagrawal9282 Жыл бұрын
Sir agar ghar aur dukan dono ek hi jagah ho ,aur dono ka meater alag jk ho to dono ka alag alag earthing dena chahiye ya ek hi earthing dena chahiye?
@MEGAclassroom Жыл бұрын
Ideally alag alag Dena chahiye. Lekin common earthing bhi banaoge to koi dikkat nahi aayegi. Jo bhi earthing banao achhi quality ka hona jaruri hai.
@agboolastephen3150 Жыл бұрын
Why can’t I see the whole labelling
@sidiubari745 Жыл бұрын
Earthing se pc,ups nahi calta hai???❤️❤️❤️❤️❤️
@MEGAclassroom Жыл бұрын
No. Phase & earthing se chal sakta hai but yah totally illegal hai.
@sujathadevi381 Жыл бұрын
Manual pl like theory and procedure
@A.T.M.C.Y Жыл бұрын
Sir make more videos for halogen And led flood light nice explained 👌 😊
@A.T.M.C.Y Жыл бұрын
Sir kya hm 500 watt tube ki jagah 1000 watt ki laga skte hai 500 watt wale halogen box light ke Ander
@MEGAclassroom Жыл бұрын
Ha. Agar box me laga hua tube holder achhi quality ka hai to. Nahi to vah garam hoke kharab ho jayega.
@arvindthakor2870 Жыл бұрын
Price
@RamKumar-fp3eu Жыл бұрын
Ye sab kya ho raha hai bhae
@Allisblissful262 жыл бұрын
kzbin.info/www/bejne/bIiwmWWprK2VrKM Plz tell how the voltage is coming 240 as normal earthing ,how much powder and soil is needed means ratio for the same
@falgunisaini79692 жыл бұрын
W wale ka name kya h
@dr.wahiduzzaman54092 жыл бұрын
Sir online buy link dijiye plzz
@abhigamshah43552 жыл бұрын
Can I use the your youtube video in PPT ?
@Rohitkumar-gq8bi2 жыл бұрын
Nice bhai!
@MEGAclassroom2 жыл бұрын
Love your appreciation.
@neerajlagwal94742 жыл бұрын
Electric Instrument ke liye yahi wali earthing ki jati h ??
@MEGAclassroom2 жыл бұрын
Koi bhi kar sakte hai. chemical earthing conventional earthing ka better & efficient version hai. Lekin costly hone ke karan ise mostly mahenge electric equipment me use Kiya jata hai.
@jeetendrakumar37042 жыл бұрын
Kyunki mere pass GI pipe hai copper plate hai aur copper wire hai aur chemical powder hai maine chemical pipe nahin kharida ismein ho sakta hai bina Koyla Namak Dale chemical agar dalenge to ho jaega
@MEGAclassroom2 жыл бұрын
Ha
@jeetendrakumar37042 жыл бұрын
GI pipe or copper plate copper wire or chemical powder dal ke Arth banaa sakte hain ya nahin main uske liye chemical pipe lagana hoga
@MEGAclassroom2 жыл бұрын
Chemical powder ek chemical compound hai jiske karan jamin me moisture long time tak raheta hai. Aur low earthing resistance provide karta hai. So, aap jese bata rahe ho vese kar sakte hai koi dikkat nahi. Lekin Better hoga uske sath chemical earthing ka rode bhi use kare.
@chetankumarjha63462 жыл бұрын
Thanks you sir
@chetankumarjha63462 жыл бұрын
Thanks you sir
@rkeventdecrationbilgram16052 жыл бұрын
Iski shit available 4×4 ka
@rkeventdecrationbilgram16052 жыл бұрын
Hlo Bhai
@ManinderSingh-cc1mi2 жыл бұрын
Bhai hmare wooden board box meter box sab sizes milte hai
@legend73302 жыл бұрын
Nice video
@amansingh96522 жыл бұрын
Numbar dan apna
@ravikumarupadhyay92432 жыл бұрын
Good👍👍
@NandanKumar-ij3bp2 жыл бұрын
Bro can be it is used for reducing tower footing resistance?
@MEGAclassroom2 жыл бұрын
Yes
@Sen78192 жыл бұрын
I would suggest using conventional copper plate and wire, with brass or copper connector ( nut& bolt ) then this, cause eventually ,this GI pipe will rust resulting in faulty earting or complete failure.
@MEGAclassroom2 жыл бұрын
These are the chemically treated electrode, so there are less chances of rusting. Even in copper there is problem of oxidation. But still it is in use. So, it means for life expectancy of earthing.
@ANILKUMAR-rc8eo2 жыл бұрын
Yah khada ham makhan ke ander ya bahar road per kare
@MEGAclassroom2 жыл бұрын
Bahar kare.
@shivekyadav99232 жыл бұрын
Kya lightning arrester ka koyi wire solar ke frame se touch krna pdta hai earthing ke liye ...
@MEGAclassroom2 жыл бұрын
Nahi. Lighting arrester ka pura set-up alag se hota hai. Usme aur koi connection nahi karna hai.
@shivekyadav99232 жыл бұрын
Kya earthing rod ka bhi volt check kiya jaata hai multimeter se?
@shivekyadav99232 жыл бұрын
Jese ki btaya jata hai ki 5v se neeche rhna chahiye...
@MEGAclassroom2 жыл бұрын
Neutral aur earthing ke bich me Voltage diffrence ideally 0 hona chahiye. Lekin practically agar vah 5V se kam raheta hai to better mana jata hai. So, earth rod voltage measure nahi karna hota hai.
@chaitanyakulkarni35102 жыл бұрын
save soil save nature kzbin.info/www/bejne/rIjdo2Cgnqybi6M