Sir,Here, admixture using matter is not involved in ACI math example. Kindly give an example math and solutions of admixture using calculations Problems in ACI mix Design.
@vishalkumar-pk2bj5 ай бұрын
Is code 2019 ke according hi kya
@rohithavanur98796 ай бұрын
Thoda calculation samjha dijiye 1.Specific gravity of cement with respect to kerosene? 2. Specific gravity of kerosene with respect to water? 3. Specific gravity of cement with respect to water? Aap to 1st &2nd wala bola hai 3rd ?
@CROW-pu9vc7 ай бұрын
In %of reinforcement at ast 524/2
@karimtripura26378 ай бұрын
Sir minimum Reinforcement should be 0.12℅ bcoz u have used Fe415 HYSD bar
@KajalKumari-wh4oc10 ай бұрын
Sir can u explain me from where we get value of phi
@dce148rajeshkumarshaw410 ай бұрын
Ye kya marathon hai 😂
@kshitijkumarkushwaha890311 ай бұрын
I recommend you not to watch this video if you are watching just before exam bcoz you will get confused instead watch engineer ki pathsala (it is lengthy ) but you will understand everything But this lecture was also good.
@kveditzz5054 Жыл бұрын
16) a) Design a concrete mix by BIS method with the following data : i. Characteristics compressive strength = 35N/mm2 ii. Maximum size of aggregate = 20mm (angular) iii. Fine aggregates confirm to grading zone II iv. Workability = 75mm slump v. Degree of quality control = Good, vi. Type of exposure = Mild (Plain Concrete) vii. Specific gravity of cement = 3.14 viii. Specific gravity of fine aggregate = 2.58 ix. Water absorption (i) Coarse aggregate = 1.9% (ii) Fine aggregate x. Water cement ratio = 0.48 Assume any other data if necessary. Also calculate the quantity of cement, sand, coarse aggregate and water required per cubic metre of concrete.
@souvik.fingtore Жыл бұрын
The word" teacher" meaning define by ur teaching style and explanation & thanks fram JADAVPUR UNIVERSITY.....😍
@civilpositive805 Жыл бұрын
Thnks
@riddhishsingh8648 Жыл бұрын
Dada Two way slab design ka video provide kegiye....
@brahmatejaballipalli3392 Жыл бұрын
Nice explanation,but i cant understand sir how you can get the area of steel Ast please reply back
@pilliarunkumar-x2h Жыл бұрын
Tq sir
@MIMO0351Q Жыл бұрын
Noobri😂😂😂😂
@harsh_shukla1555 Жыл бұрын
Sir why for deflection check you have not multiply 1.3 as slab is in confinement?
@sravankumar14 Жыл бұрын
Super sir
@nasarashraf Жыл бұрын
nice 👍
@chirantanibiswas Жыл бұрын
For slab design the basic value is on the page 39.
@teja1424 Жыл бұрын
Design the concrete mix for the following data: characteristic compressive strength = 35MPa, maximum size of aggregate =20mm (angular), Degree of workability = 0.9 CF, Degree of quality control = good and type of exposure = severe. Water absorption by CA = 1% and moisture content in FA=1.5%.Assume any suitable missing data.
@insideouttek2361 Жыл бұрын
Simply support q liya
@Belowaverage541 Жыл бұрын
Thankyou sir bohot ache se explain kara apne
@bhubaneswarimohanty7465 Жыл бұрын
From where the clear cover value came sir ?
@aashishdas9981 Жыл бұрын
Slab Ka area of rf 0.12 % of cross sectional area hota h
@aashishdas9981 Жыл бұрын
Dead load and live loads have different unit,then how can they be added? One is in n\m and other is in n\mm^2
@shashank_d_a Жыл бұрын
Thank you soo much sir...., 💗
@nasarashraf Жыл бұрын
Good
@Hello_family111 Жыл бұрын
Worst cam quality with good explanation
@viralvideoshort603 Жыл бұрын
Good project
@ajayahirajay7349 Жыл бұрын
Jay Dwarkadhish
@ashoksanghvi7126 Жыл бұрын
Very nice 👌
@jatindadwal2492 Жыл бұрын
When ur teaching is passion and not a work ! Loved ur explanation ❤️
@ASMohamedZiyath Жыл бұрын
good
@ravishankars1420 Жыл бұрын
Looks like the bridge is ready in all respects to be opened to traffic, any idea when it is likely to happen..
@SuperMan-pv5ee Жыл бұрын
thankyou
@53piyushghagi282 жыл бұрын
Thank you
@prakashbhuyiar51062 жыл бұрын
It was good explanation 😊
@sridharmaddamsetty30462 жыл бұрын
Very beautiful explanation to understand how to do experiments.......simple and clear ThanQ sir
@vishnuvirat13822 жыл бұрын
why the b is taken as 1000 here
@moinkhan89202 жыл бұрын
Clear cover values?
@ramanraj6144 Жыл бұрын
assumed, keeping d in mind.
@kalpeshbadgujar6662 жыл бұрын
Hello Sir, In check for deflection the value of actual deflection is 29.41 and permisible value is 29 then it is safe or not ?
@se1-03-krushnkantjanardanb62 жыл бұрын
Sir two way slab ka upload karo na
@vishalbaraiya76842 жыл бұрын
💯👍👍👍
@vishalbaraiya76842 жыл бұрын
Very good video Okha to bet Dwarka thank you very much
@teerthagauravyadav45242 жыл бұрын
जय द्वारकाधीश, जय मोदी जी
@vijayraut48912 жыл бұрын
Modification factor 1.55 how isn't it 1.35, Can u make me clear Pls ....
@vijayraut48912 жыл бұрын
Can anyone make me clear....
@D.G.-792 жыл бұрын
How Much Time Will be Taken For Completion of The Project??
@civilpositive8052 жыл бұрын
Next Year Complete approximately 65% to 75% work completed.......