Pede po ba mgsend ng pera sa gotymebank from stc pay?
@geemeilАй бұрын
UrPay po kasi gamit ko at nag try ako mag add beneficiary (Bank) kaso wala ang GoTyme sa listahan😌...try nyo lang po mag add beneficiary sa STC pay nyo kung nasa list po sya.
@niketyche9004Ай бұрын
Wow ha
@bisayakoday3987Ай бұрын
Wow thank you po. Paano kung gawin syang pang bayad sa grocery..pwede kaya?
@geemeilАй бұрын
hindi ko pa po sya nasubukan gamitin sa grocery dito sa KSA😊
@00M7912 ай бұрын
Thanks for your video The problem has a password if you know the password it contain of 3 digits I would really appreciate your help.
Sir pag saudi kaya pwde mag transfer remittance dito sa saudi bank ng go tym
@geemeil3 ай бұрын
As per Go Tyme... Can my GoTyme Bank account accept and send international transfers? Outgoing international transfers are not available yet. However, GoTyme Bank can already accept incoming international transfers from select sending partners. Using your GoTyme Bank account number, you can receive transfers from Wise, World Remit, and RIA. Using your GoTyme Bank Visa debit card number, you can receive transfers from PayPal, Western Union, Remitly, and Money Gram. Note that transfer times and fees may vary depending on the platform and source country. Nag try din po ako dati using Al Rajhi online Visa Direct transfer,(add beneficiary) after sending ay nag bounced back ang remitance ko after 3days.😊
@NicksonFieldad2 ай бұрын
Ay hndi po pwede Ang Al Rajhi to gotyme bank na padalhan po?
@Idealcalibrations3 ай бұрын
Hey Gerald, love the content, you're doing great work! Where are you out of? If there's a way to send you some calibration gas to sponsor some videos I'd love to do it. Keep it up!
@xanzack4 ай бұрын
hi sir. tanong ko lng po yung co monitor po is nag countdown ng "warm 120s" tapos namatay po compressor at nag flash ng red 6 times. ano po kaya problma?salamat po
@geemeil4 ай бұрын
Try to wait CO monitor displays 0ppm, then run compressor. If LCD display shows a high concentration of CO activating your shutdown alarm settings after 120sec countdown then you need to make it 0ppm 1st before running the compressor. Hope this solves your problem.😊
@rosmarytayros99824 ай бұрын
ayos...
@mhrfaisal85235 ай бұрын
Hello Sir can you share your whatsapp contact number I have some issue BAUER CO MONITOR during zeroing?
@geemeil4 ай бұрын
kzbin.info/www/bejne/p3PWdYFsqbBkhdk - Bauer CO zeroing
@mhrfaisal85235 ай бұрын
Hello Sir can you share your whatsapp contact number I have some issue during zeroing?
@mohammedalhowar7465 ай бұрын
The best trainer, Mr.G, thank you for your support and trying to deliver all your knowledge and experience to us.
@geemeil5 ай бұрын
Anytime bro!
@fredhinck96856 ай бұрын
Simple test, no tools required. Start engine, turn headlights, shut engine off. Headlights dim a bit, alternator ok. Headlights stay the same, problem in the charging system.
@ДенДен-ю7ф6 ай бұрын
You are the best one. Thanks a lot
@mahail1118 ай бұрын
Thank you for the great video. ❤ When I did the calibration date it showing 2012 how can I fix the issue.
@geemeil8 ай бұрын
Update your time and date first before doing the calibration. Once successful the time and date will be saved. 😊
@gultariq43489 ай бұрын
Absolutely amazing. But please make a vedio how to set cutoff at 5ppm of co and H2s monitor
@abhishekfrancis72819 ай бұрын
We have a better solution which is quicker than any other breathing apparatus kzbin.info/www/bejne/hKGWnpl9ndKfiNkfeature=shared
@apnaknowledge522710 ай бұрын
👍
@gultariq434811 ай бұрын
Great vedio thanks. Please what is solution of co sensor when it show remove cal gas soon
@geemeil11 ай бұрын
Didn't encountered yet, but try to watch this video maybe it could help. Try checking both flow switch. Both are normally open. kzbin.info/www/bejne/i3uVlaZ5bLqYeM0
@gultariq434811 ай бұрын
@@geemeil thanks
@crazyfact779211 ай бұрын
Hi pare In x40 controller and cx sensor rf channel and modbus id is same?
@geemeil11 ай бұрын
There must be only one RF used to Setup a system. X40 main (master) panel has different modbus assignment. X40 site sentinel must use slave modbus on RXT320 & connected to a DA-4. So there's no need to use modbus on the CX sensors if it's connected to a DA-4. The DA-4 can handle 4 sensors on a single modbus. (Stand alone but can be added to the network). CXTs are also using slave modbus id's. All assigned modbus id's must be detected during auto configuration.
@shabihshah6355 Жыл бұрын
Informative
@anishpinto6409 Жыл бұрын
How set co 5 ppm in the monitor ? Please suggest brother
@geemeil Жыл бұрын
Open the monitor you will see 2 buttons at the right side. Press Setup until you will see CO span gas concentration. (Ex.20ppm) Press Select many times until 5ppm Press setup to exit.
@basil1134 Жыл бұрын
Thanks
@deepeshpoulose8607 Жыл бұрын
Brother can I ask a doubt.. ? Pls rply
@geemeil Жыл бұрын
Yes bro, just write a message for your clarification.
Brother...the co unit is detecting co even without co presence....the compressor screen is then showing.....this precautions for co unit>> replace cartridge, check flow to co unit, calibrate. Pls pls help me!!
@geemeil Жыл бұрын
Try to purge zero air on the cal.port around 5-6 seconds so that it will not continue to calibration. Do it as needed until zero ppm display on the screen. If not try replacing the sensor head then recalibrate. You will be needing Zero & CO gas.😊
@gobeaug Жыл бұрын
Thanks for sharing
@geemeil Жыл бұрын
Thanks for watching!
@oriproducts Жыл бұрын
How to download firmware? Please share downloading link
@seirradakota6620 Жыл бұрын
A 15 minute air tank that turned into a 5 minute air tank max. Breathing like he did will kill your air tank within a few minutes.
@geemeil Жыл бұрын
Activating the bypass valve for few seconds will purge any contaminants inside the facemask & will create a positive pressure immediately on the mask. Continues bypass will really consume the air faster approx 5min... The 15min expected air duration can be even more if breathing is controlled. Because this unit is equiped that is called "demand valve" so it gives the air you demand/require.
@iammichaell25382 жыл бұрын
Big fan here more videos to upload
@iammichaell25382 жыл бұрын
Subscriber here bro
@amantali9352 жыл бұрын
Great
@onofrelopez12752 жыл бұрын
👏👏👏👏👏👏👏👏👏👏👏👏👏
@ltheblindmonklleesin69525 жыл бұрын
Dear Gerald I want to ask you about that line that you connect your hose to it if you can tell me what is the name of that equipment . best regards.
@ltheblindmonklleesin69525 жыл бұрын
@gerald
@geemeil5 жыл бұрын
"workline" hose connected to reserve air manifold
@geemeil5 жыл бұрын
they call it "pig tail" , that is the connection from the unit to connect into a "workline" hose/manifold. Once "pigtail" is already connected to the "workline" hose/manifold, the 15min cylinder valve must be closed to conserve the air from the 15min cylinder for escape. It should be opened only once you will be moving away from h2s zone.
@garED16785 жыл бұрын
ETSDC?
@ElectronicNoobBlog6 жыл бұрын
Interesting, i never came across leg mounted air cylinder. Is there any special reason for that location over back?
@geemeil6 жыл бұрын
It is designed for workline & escape. On the other hand the cylinder mounted at the back are designed for rescue, escape & can also be used at workline, but its around 22-25 kg at your back.