I laughed. I cried. I watched it again and again. Two thumbs up! Fun for the whole family.
@jimneustadt2688 Жыл бұрын
This is a great video on a great company.
@teklesenbetgebreamlak7365 Жыл бұрын
Great content straight to the point appreciated your time.
@juanq7591 Жыл бұрын
L7224...tiene un Err10...como solucionarlo..por favor..
@bagherirani8821 Жыл бұрын
👍👍👍
@NathanThePrezPretlow Жыл бұрын
What a your recommendation on hot water temperature on a hydronic boiler for a two family house.I have no zone valve
@josephpatterson9993 Жыл бұрын
Excellent Video! Thanks so much,
@ilovenythismuchilovenewyor5801 Жыл бұрын
excellent video definitely saving this to my hvac education list thanks
@Dhspat2 жыл бұрын
Great video. Thanks. ☘️☘️☘️☘️☘️
@raudelulloa25972 жыл бұрын
Can I buy directly from Neuco, Seems like Bob is an unnecessary middle mad
@neucoinc.8544 Жыл бұрын
Hello Raudel. Unfortunately we only sell to wholesale distributors, so yes you would still need to go through "Bob" for your HVACR needs.
@alfierivera51852 жыл бұрын
Can you give some example of tools using Belt Tentioning
@jivepatrol68333 жыл бұрын
Excellent video on how this pilot system works! One edit - intermittent is spelled incorrectly on your opening slide! Thank You! 🙂👍
@DaddyMacNeil3 жыл бұрын
What would cause the sensor on a L7224 to fry. I have had four L7224U units in the last four year and it keeps coming up with ERR 1 Code and sometimes and ERR 6.
@samuelferrer8053 жыл бұрын
thanks for the video, I have the L8148E, and I want to change my thermostat for the RTH6580WF. I only use the heat and my old thermostat works with two wires. where you should connect the wires for the other thermostat. Thanks
@mrtaktiks3 жыл бұрын
The Honeywell website Tech Support page is down. How can I contact you?
@TheRealoldcar3 жыл бұрын
awesome
@wok-ur-katt19953 жыл бұрын
Thank you for the training module.
@billybassman214 жыл бұрын
I like these better than hot surface ignitor. I wonder if this dude is still around? This video looks to be from the 90s.
@lukez17294 жыл бұрын
Thank you so much for these videos your a great help!. Please make more videos!
@stanthology4 жыл бұрын
Clear. Understandable . Even for a non serviceman. Holy cow!
@KC-qr4sc4 жыл бұрын
Excellent Video...
@user-fw6eg3hc8f4 жыл бұрын
Can the L7224U replace the L8148a1017 and be more reliable?
@pradipsimpi85224 жыл бұрын
Hi
@ghislaincote84225 жыл бұрын
my burner ignites but the spark does not go out
@PBS-nm1uu5 жыл бұрын
can't find the other two lessons thanks
@Samlol23_drrich4 жыл бұрын
Are you still looking?
@jakefoskett16042 жыл бұрын
@@Samlol23_drrich also yes
@Samlol23_drrich2 жыл бұрын
@@jakefoskett1604 I’m still looking too.
@marksteven35345 жыл бұрын
Beads are better- That's all I see here why not make a more compelling case than that to use this over the catch-all solid core filter dryer.
@al522696 жыл бұрын
are all honeywell pilot burner with orifice the same thing
@Rgregorio18057 жыл бұрын
Excelente video
@brianellsworth47677 жыл бұрын
I get spark and pilot. Cleaned flame sense rod and no 24 volts to main valve . I don't have a meter that can read micro amps . Should the flame sense rod read 0 ohms from rod to connector. What out put voltage is the flame rod suppose to sink.. It reads 20 volts ac at the module .I read 4 volts at the flame rod ,but it restarts the igniter ... that was yesterday.,, Today I wiggled the flame rod connector at the module and main gas burners now work. I am replacing both module and pilot assembly that are 27 years old,but realize how little I really know about the electronic architecture of a any module.Since the boiler burners were submerged from a cellar flood I removed and cleaned every thing ,burners ,assembly ,etc. . The small amount of resistance from my meter prevented ignition, I wonder if it was only residual moisture. A good service tech would sell a new boiler ,but it is mine and it feels like I installed only yeaterday
@arthouston73617 жыл бұрын
Brian, I doubt that a responsible HVAC tech would undertake a DIY conversation with you regarding your issue. Your and your family's safety is best served by bringing in a professional, one who will, by his business insurance, assume the liability for the job and make a safe and correct repair.
@Milosz_Ostrow5 жыл бұрын
Assuming all electrical connections are secure, the problem is most likely the controller module. I had the same issue a few years ago. By cleaning the flame sensor with fine emery paper, I got the furnace to limp along from November to February, then ended up wearing heavy clothing until the weather got warm. Further cleaning of the flame sensor proved fruitless. Eventually, I took a chance ($) and replaced the 20-year-old Honeywell controller with a new Honeywell unit, which restored normal operation, using the same old pilot burner and ignition electrode. An advantage of the newer Honeywell control module is built-in continuous self-testing and an LED that reports what is going on with a blink code.
@aquarius94914 жыл бұрын
whats your life insurance company ???
@lujar767 жыл бұрын
Thank you so much for the information. I needed the main valve pilot valve jumper. You are awesome.