Best video, excellent clarifications specially about Battery blast. I have experienced battery explode twice during testing. Its highly dangerous and needs lots of care and safety, because Acid dissipates quickly.
@MuhammadJunaid-bt4qqАй бұрын
One thing I need to know. Why battery sometimes explode during testing of DG Pump ?
@MuhammadJunaid-bt4qqАй бұрын
Also how to test all these 3 pumps in sequential manner automatically and manually.
@MuhammadJunaid-bt4qqАй бұрын
Very informative, please also mention the Pressure Switch and Static switch .... Flow switch and their functionalities.
@DipnarayanYadav-u2cАй бұрын
Desl pump dran enfaramsn
@aadilahmed3259Ай бұрын
Panel ko shutdown or turn on kaise krte hai?
@SunilSharma-ge3ur2 ай бұрын
Sir I have some quarry
@SunilSharma-ge3ur2 ай бұрын
Give me your No. I need help
@BilalKhan-fq2vd2 ай бұрын
Where is programming in this video
@AsadYaseen-v8z2 ай бұрын
Good
@technicalfire78652 ай бұрын
Thank you
@mithilrao38352 ай бұрын
Sir main line open karne k baad bhi deluge open kyu nabi bua
@technicalfire78652 ай бұрын
Deluge Valve ke sath aik manual start valve hota ha us KO open Karo Jo 1" Ki Line Ka connection Deluge Valve ke sath hota usi line Ke last 1/2" Ka
@RameshverDhiman2 ай бұрын
Hii bro module ka connection me kbi kbi no terminal konsa hai pta nhi hota kaise pta chalega please make video.
@technicalfire78652 ай бұрын
Ok Shure Thank you
@arbaazansari0092 ай бұрын
HALLO SIR MUJKO AAP KA CONTACT NUMBER CHIYE PLEASE
@arbaazansari0092 ай бұрын
Sir I need your contact number
@RameshverDhiman2 ай бұрын
Fire alarm system me no nc prr video detail please Zcv, Lift, damper kisko no chaiye aur kisko nc detail video please
@technicalfire78652 ай бұрын
Yes 👍
@HAVEN_ON_EARTH2 ай бұрын
Har equipment ki brand bhi Batayee karee
@technicalfire78652 ай бұрын
Okay 👍
@HAVEN_ON_EARTH2 ай бұрын
Konsi brand ki pannel h brother??
@HAVEN_ON_EARTH2 ай бұрын
Breaker ki cable kitneki mm ki h??
@RameshverDhiman2 ай бұрын
Bro Fire Fault ke liye konsa module use hota hai aur connection bi please detail video bnao Doubt hai jaise building ko fire kaise jata hai aur fault
@RameshverDhiman2 ай бұрын
👌👌👌👌👌
@kingofthemagic2 ай бұрын
D1 9 aur D27 main power 24 voltage ki cable lagegi
@ManjeshKumar-qy7zh3 ай бұрын
Battery ko shot kaise marege Bhai Thoda Batana
@Namaste_Unjha3 ай бұрын
Sir merko Deluge Valve Ka Service Me And Maintenance me kya kya aata h and kaise krte h vo Janna h
@technicalfire78653 ай бұрын
Deluge Valve Ki service Karne se pahley ap aik bar manual start Karin phir us Ke baad gate valve band Kar Ke service Kar lo
@RameshverDhiman3 ай бұрын
❤
@RameshverDhiman3 ай бұрын
❤
@rajeevmeena22623 ай бұрын
Sir Gaund fault Aa raha haa Kesy tik kar saktyi haa. GST addresslabel panel haa)
@technicalfire78653 ай бұрын
Ap panel Ko open Karo us mein Dekho samne bord Ke sath white colour little size ki ha us KO remove Kar do Mein ........, Ap fire cable Jo ap use karate hen 1.5mm Ki us Ke andar aik earthing cable hoti hai wo check Karo kis Ke sath touch Kar rahi ha Agar ap KO mil jati ha Tu us Ke oupar insolation type Kar do. Thank you very much 🙏😊
@rajeevmeena22624 ай бұрын
Continuity Kitni length Tak check kar sakte hain sir