Dear: It is possible to link the coordinates of a pipe network developed in QGIS (Shape Format) to Hydropass.
@MehdiGdrz Жыл бұрын
As a piping engineer in oil a comparison between PASS and CAESAR II and more importantly Companies that currently are implementing this App for me is essential
@richardv9648 Жыл бұрын
I think this is a bit over analysis. Practically you are saying a 200NB Sch. 20 Pipe connected over 3 meters span by fixed support operating at 0 pressure, 150 degrees will fail due to axial stresses? Then I have news for you, I design Ammonia suction and discharge pipe over these mentioned ranges some of them operating for over 20 years never had any problem or failure.
@ManuelSilva-lv6un Жыл бұрын
Make a video about this please. Im sure several people here would watch and enjoy it.
@andikanudoh372 Жыл бұрын
Please how can I get the software
@ndy7394 Жыл бұрын
Thank you!
@richarddarko8770 Жыл бұрын
This looks like a very versatile software. Compared to AFT that’s unfortunately has split the requirements into four separate softwares. Can pass hydro stem it still do 2D models?
@bubapedongpetracubliphant75262 жыл бұрын
how much is pass software? I need one.
@herouinihamza38572 жыл бұрын
Thank you for this useful presentation
@erwanpena5262 жыл бұрын
Me gustaria descargar el plugin.
@herouinihamza38572 жыл бұрын
Thank you ,Sir
@האחיםאוחנה2 жыл бұрын
Thank you for the detailed explanation. Regarding the example you gave with the equipment nozzle check, if I understand correctly in case the vessel is anchored to the ground, effective axial force R is not equal to 0. Am I right?
@PASSuite2 жыл бұрын
It doesn't matter if the vessel is anchored or not. Anchor will affect only thermal expansion and piping axial elongation due to pressure if it has anchor on the other end
@mohamedfathalla33582 жыл бұрын
Do you use erw steel pipes in refinery
@marchievful3 жыл бұрын
If the fitting is failing or overstress, do we need to adjust the thicknes of the fitting as a solution or introduce flexibility on the system?
@PASSuite3 жыл бұрын
Usually thickness is calculated to hold internal pressure. But sometimes increasing the thickness help to solve the problem with sustained or expansion stresses also. But only for the fittings and only sometimes. Usually we need to add supports and increase flexibility
Does it shows the Maximum Displacement at particular Mode??
@PASSuite3 жыл бұрын
Yes
@engsoft5903 жыл бұрын
I Need a freelancer who can do project with PASS Equip.
@anindyadas33833 жыл бұрын
I am a freelancer
@murtuzakazi112213 күн бұрын
I need piping stress analysis freelancer for PVC, UPVC and HDPE piping
@engsoft5903 жыл бұрын
I Need a freelancer who can do project with PASS Equip.
@engsoft5903 жыл бұрын
I Need a freelancer who can do project with PASS Equip.
@AN-tm5jp3 жыл бұрын
Great work
@PASSuite3 жыл бұрын
Thank you!
@athabascaengineeringsolutions4 жыл бұрын
Thanks
@PASSuite3 жыл бұрын
Welcome
@waritsriski_61104 жыл бұрын
Hi, can hydrosystem software analyze hydraulic calculation two fluid from different pipe and then mixed in 1 pipe ? Thank you
@PASSuite4 жыл бұрын
Yes, if these two streams have the same composition, and no, if you need to calculate mixing of two different fluids (but we plan to add this feature in future versions of PASS/Hydrosystem)
@waritsriski_61104 жыл бұрын
@@PASSuite thank you for the answer
@SWIM_MUSIC_TRAVEL4 жыл бұрын
We are having project s(HDPE lines) that needs to be stress analysed. Please refer anyone who do. [email protected]
@PASSuite5 жыл бұрын
Full version on our website passuite.com/start#resources-tab
@ShivaKumar-jf4mc5 жыл бұрын
Please upload the full vedio on webinar
@PASSuite5 жыл бұрын
Full version on our website passuite.com/start#resources-tab
@myhoa37775 жыл бұрын
Download and install PASS/START-Prof now. After installation, configure access to the dongle by IP 94.79.15.138: Installation Read Quick Start Guide Download and install START-PROF Start the Dongle Setup program from the Start Menu: Start > Programs > CTAPTPR > Setting up network dongle. Select Net protocol TCP/IP. Enter Dongle Server Address 94.79.15.138 value into the 'name of the server' input field. Press Ok
@PASSuite4 жыл бұрын
Download trial version again from demo.passuite.com/ now it will configure automatically. No need to do anything manually
@shivakumards34785 жыл бұрын
Nice presentation, please update more videos on this
@PASSuite3 жыл бұрын
Thank you, I will
@abujunaid95335 жыл бұрын
Wao great, a very big piping model, In caesar it's very difficult to analyze bigger models because I often encountered a convergence issue,
@PASSuite5 жыл бұрын
Please see this video about convergence issue: kzbin.info/www/bejne/jIKXgqGfnZmabrc And this article: www.whatispiping.com/caesar-ii-non-convergence-issue
@abujunaid95335 жыл бұрын
It's interface just like Bentley AutoPipe,
@PASSuite5 жыл бұрын
Better and simpler :)
@abderahmenbouchhima13486 жыл бұрын
can you specify the fluid you used in this simulation?
@PASSuite6 жыл бұрын
It's a water steam close to saturation point. But in Hydrosystem you can calculate flashing/condensing flow for any other type of fluids (pure substances or mixtures). It has a very large components database (about 1600 components)
@axilengg2196 жыл бұрын
Bilateral Integration is Really very helpful & that's Nice..