Пікірлер
@WiiUser2763istrash
@WiiUser2763istrash 13 күн бұрын
So close to 1k❤️❤️
@amandedhia
@amandedhia Ай бұрын
why is there a 3 minute long unskippable ad at the beginning for the video?! It is crazy
@amandedhia
@amandedhia Ай бұрын
followed by another 1 minute long skippable ad?! WTF?!
@tadlast4938
@tadlast4938 Ай бұрын
Rubbish system hot water didn’t work properly
@SuperDiagnostic
@SuperDiagnostic 2 ай бұрын
Aargh.. with a new installation I was just about to wrap my antifreeze valves.. glad I checked but do wish they came with fitted purpose made insulation though 🤔
@DALEYPLUMBING
@DALEYPLUMBING 3 ай бұрын
Looks great Ed 👍
@danoneill8751
@danoneill8751 3 ай бұрын
You've gotta love it when a plan comes together - my quesiton was, does this thing detect the air or the water temp and as such, can I insulate the crap out of it as its on a heat pump an will be outside? First vid, 'how do you insulate the valve', well done!
@RGSABloke
@RGSABloke 4 ай бұрын
You need to speak slowly young man, great advice here. Joe
@charntsabre3463
@charntsabre3463 4 ай бұрын
The Thermostatic Element expands in the center depending on temperature, how does it do that? Is the metal just a metal with an expansion rate for heat that we found that is roughly acceptable and safe for most human skin?
@shanebutcher9158
@shanebutcher9158 4 ай бұрын
Can you please tell us which unions you use either side of these valves?
@donnaham9724
@donnaham9724 4 ай бұрын
How do I completely stop any water passing the valve so I can get the radiator off? Thank you
@greedycobra1446
@greedycobra1446 5 ай бұрын
Good video thanks for uploading 👍🏻
@josephmcmahon7470
@josephmcmahon7470 5 ай бұрын
How have you converted the kW outputs to Volume?
@meyrickstephens
@meyrickstephens 5 ай бұрын
This valve is made of brass, so it is a very good conductor of heat, which means that not insulating this valve will compromise the heat retention. Effectively this valve seriously reduces the efficiency of the ASHP system.
@mattiasback5846
@mattiasback5846 5 ай бұрын
Can you manually open the valve to empty the system? Or do you have to wait for the thermostat? For example if you know there's a long power outage.
@perjohanbroden7513
@perjohanbroden7513 6 ай бұрын
How do you know if the thermostatic cartridge is faulty until the function of the valve is needed but not working (in other words, how do you know before it is too late to know)?
@jimmyman8031
@jimmyman8031 6 ай бұрын
Aren’t there any filters that need checking???
@yelimsssantiago5328
@yelimsssantiago5328 7 ай бұрын
What are the consequences of this valve functioning? When reaching temperatures of 3 degrees and below, I understand that the water is released out. But... can it be released only from the heatpump and leave rest of the water - from the inhouse heating system - intact? Or there is a risk of depressurising and emptying the entire heating circuit, also from inside the house?
@altecniclimited947
@altecniclimited947 7 ай бұрын
Thanks for your question! The operational function of the valve is to draw warmer water from the system to the cooler parts to prevent freezing, this would no doubt over a period of time draw water from within the property. The discharge rate is approx 0.5ltrs per hour at -5deg, however for the system to drop to 3deg at -1deg ambient temperature could take up to 36hrs so the chance of activation is minimal. Also if the valve were to activate, I would assume only an amount of the head of pressure will be released and not full system drainage. For any more information, please follow the link: www.altecnic.co.uk/contact-us/
@yelimsssantiago5328
@yelimsssantiago5328 7 ай бұрын
@@altecniclimited947 thank you for such a complete answer. I finally understand its functioning.
@ngocehgayabebas2118
@ngocehgayabebas2118 7 ай бұрын
Thank you
@KBradAdams
@KBradAdams 8 ай бұрын
I want a mixing valve that fits where my existing valve is and does nothing but let as much hot water as I want into my soaking tub.
@jlongrigg
@jlongrigg 8 ай бұрын
Thanks for sharing this. I recently replaced Myson TRV with one from Toolstation - the head only, which fitted on okay. I also did the same with one from ebay. When I switched the heating on, the room temperature was already 18 degrees in the two rooms and the trv was set on number 1, but the radiators still warmed up - eventually reaching 20 degrees, yet the TRV shouldn't have activated because number 1's temperature activation was no more than 14 degrees. I expected to turn the knob to number 3 if I wanted 20 degrees. Do some of these TRVs not work as expected for some reason? I could go out and purchase your brand but I am unsure if I might experience the same problem.
@alexp893
@alexp893 8 ай бұрын
Interesting product. Can I use this in my loft on the water supply to my central heating's feed & expansion tank?
@jason23419
@jason23419 8 ай бұрын
Have fitted two today! Incredible product.
@altecniclimited947
@altecniclimited947 8 ай бұрын
Glad you like them! Thanks for the feedback!
@yogeshmistry1662
@yogeshmistry1662 8 ай бұрын
Hi Ed, Excellent informative vedios as always. I am struggling to find the special spanner and replacement cartridge you presented on the Caleffi 535H series a year ago. Can you please advise where I pay be able to purchase them in the East Midlands UK. Thank you
@altecniclimited947
@altecniclimited947 8 ай бұрын
Hi @yogeshmistry1662 - thanks for your question. Please email the details to [email protected] who will be able to help you find the exact part you need and recommend a stockist. Thanks for watching!
@naimrached1409
@naimrached1409 8 ай бұрын
you must change the design to include a waste exit on the hot side ; why ? because when you have a solarheater on the roof, you need to waste the cold water in the pipe till you got the hot one; Thinking to be used on dishwasher as well.
@tractortamno1
@tractortamno1 8 ай бұрын
Does it significantly reduce the water flow? Thanks
@Bulls79
@Bulls79 6 ай бұрын
Same question, did you get an answer?
@tractortamno1
@tractortamno1 6 ай бұрын
@@Bulls79 nope.
@Bulls79
@Bulls79 6 ай бұрын
@@tractortamno1 maybe I'll go with a standard mixer, to avoid any issues! 😄
@edmorris2848
@edmorris2848 5 ай бұрын
Hi, no the flow rate is not significantly reduced, in fact the flow restriction in the tap will have more of an impact than the TMV
@eazyrat
@eazyrat 9 ай бұрын
Is the cap on a fillings loop for a pressure gauge?
@its_just_me1378
@its_just_me1378 9 ай бұрын
Do you ship to the US?
@altecniclimited947
@altecniclimited947 9 ай бұрын
Thanks for showing interest in our products! There is a Caleffi North America, where you will have access to our range of Caleffi products, including the iStop® Anti-Freeze Valve. You can find out more using the link: www.caleffi.com/en-int/antifreeze-valve-108-caleffi-108601
@its_just_me1378
@its_just_me1378 9 ай бұрын
@@altecniclimited947 thank you, but I still don’t see a way to actually make a purchase from that site. it seems all of the valves I’m finding for sale are in Europe.
@its_just_me1378
@its_just_me1378 9 ай бұрын
How can I get one of these in the USA?
@altecniclimited947
@altecniclimited947 8 ай бұрын
Hi - thanks for watching! You can email [email protected] who will help you find a local stockist.
@lesroberts3226
@lesroberts3226 10 ай бұрын
Absolutely loved this presentation Ed 👍 I am aware that this was posted a while ago but your products are leaps and bounds ahead of what I work with.
@altecniclimited947
@altecniclimited947 8 ай бұрын
Awesome, thank you for your feedback and thanks for watching!
@lesroberts3226
@lesroberts3226 10 ай бұрын
Good evening. I’m midway through your presentation and I’m finding it really informative. I’ve just started working on a university campus and one of the main buildings is comprised of student accommodation and a hotel. The original installation is a district system supplying multiple hiu,s . The main problem in my opinion is the hot water primary pipe work supplying the required heat to the plate exchanger . Although the pipe work is insulated the heat generated by the primary circuit throughout the building and in the risers creates a level of radiant heat leading to constant complaints. I would like to hear what you think mate. 👍 Many thanks, and kind regards, Les.
@altecniclimited947
@altecniclimited947 8 ай бұрын
Hi Les, for all technical advice you can email [email protected] or call us on 01785 218206. Thanks for watching and for your feedback.
@julietpaul1685
@julietpaul1685 10 ай бұрын
P R O M O S M
@MrUlhasan
@MrUlhasan 10 ай бұрын
In my shower it disperses only hot water at all temp settings. Does it matter if cold or hot lines are incorrectly connected? Please advise. Thanks
@grantcivyt
@grantcivyt Ай бұрын
Yes it of course matters if hot and cold are incorrectly connected
@poorfordtransitowner1627
@poorfordtransitowner1627 11 ай бұрын
Does this empty the system if the pipework drops below 3 degrees?😊
@johnward5006
@johnward5006 11 ай бұрын
Great, concise content.
@altecniclimited947
@altecniclimited947 8 ай бұрын
Thanks for your feedback and for watching! You may find our free, accredited, on demand training portal, Altecnic Academy of interest too. You can find training course details on our website at www.altecnic.co.uk/technical-hub/training-and-cpds/ - would love to get your feedback on this.
@primarypro1627
@primarypro1627 11 ай бұрын
like that
@kaneduffy5637
@kaneduffy5637 Жыл бұрын
Any filter you can visibly see the iron oxide/ buid up through is a winner, however i would like to see a more substantial sized magnet incorporated within. All the best. Kane Plumbtek
@markbrown2248
@markbrown2248 Жыл бұрын
The chamber does not look big enough if the system was heavily clogged also is that magnet big enough?
@altecniclimited947
@altecniclimited947 Жыл бұрын
Thanks for your question Mark, we absolutely agree that choosing the right filter for the right system is key to ensuring an efficient working system for installers and homeowners. In the case of a heavily clogged system, a magnetic filter alone would not solve the problem and a full system flush would be required prior to installation of a filter like the XS. We also have a range of other magnetic filters with larger collection chambers that may be more suitable to larger systems. The benefit of installing the XS would be that the glass visual indicator allows installers and homeowners alike to visually inspect the cleanliness of a system without having to isolate and drain, meaning you only take action when it's required.
@simonsprott6216
@simonsprott6216 Жыл бұрын
Do you just need 1 valve near the heat pump or one on the flow and the return from the heat pump?
@altecniclimited947
@altecniclimited947 Жыл бұрын
Hi - you need one on the flow and the return. Please get in touch with our technical team at [email protected] if you would like any other info.
@Dorsetwatersofteners
@Dorsetwatersofteners Жыл бұрын
Nice wanted to get the tec spec but your download section only has a picture.
@altecniclimited947
@altecniclimited947 Жыл бұрын
Hi @dorsetwatersofteners, you can now find the data sheet in the technical specification on the product page: www.altecnic.co.uk/drytraptundish
@Marty501000
@Marty501000 Жыл бұрын
I've searched but can't find how the thermostat function is achieved? Is it like the wax filled automative themostat?
@macdonaldplumbingheatingsupply
@macdonaldplumbingheatingsupply Жыл бұрын
Brilliant Video 😊🤝🏽🙏🏽
@altecniclimited947
@altecniclimited947 Жыл бұрын
Thanks! - let us know what else you might like to see 😄
@drdriedger3429
@drdriedger3429 Жыл бұрын
I am in Canada. I am not familiar with the word 'commission' , as you use it. We would say service, or maintain.
@raymondtavener9797
@raymondtavener9797 Жыл бұрын
It is servicing or planned preventative maintenance he should of used. Also he forgot to mention to descale all parts including the strainers on each side. Also to record the incoming cold and hot water temperature going to the TMV’s and adjust the mixed temperature of required. You should also do a fail safe test which consists of isolating the cold and making sure the tap don’t run with just the hot coming out if so it will need replacing.
@mitch19636
@mitch19636 3 ай бұрын
Hi Mate; COMMISSIONING OF THE VALVE Upon completion of the installation, the valve should be tested and commissioned as per the procedure outlined below or as specified by the local authority. The entire procedure should be read through thoroughly before the commissioning of the valve. A calibrated digital thermometer with rapid response time with maximum temperature hold, a small flat-bladed screwdriver, 3mm Allen key and the adjusting key (supplied with the Aquablend 1500) will be required to check and set the outlet mixed temperature of the valve. Ensure all outlets that will be serviced by the valve have adequate warning signs posted to ensure that no outlet is used during commissioning. Open the cold supply line to the valve, then open the hot supply line, ensuring there are no leaks. Open the outlet that is serviced by the shortest length of the pipe work between the mixing valve and outlet fixture. Allow the mixed outlet to flow for at least 60 seconds to allow the temperature to stabilise before taking a temperature reading at the outlet with a digital thermometer. The flow rate should be at least 2L/min. The flow rate can be checked with the aid of a known size container and a stopwatch, or Enware Flow-Cup (ATMS1201). The temperature should be taken at the closest outlet served by the thermostatic mixing valve. If the outlet temperature requires adjustment please follow the steps below. TEMPERATURE ADJUSTMENT 1. Using a small flat-bladed screwdriver, lever the Red Lock Shield (protective cover) off the valve. SEE IMAGE 5 (over page) 2. Loosen the temperature adjustment locking grub screw located on the hex of the top cap using 3mm Allen Key. SEE IMAGE 6 If the grub screw is not easily accessible, relocate the grub screw to the most accessible screw hole (3 screw holes are provided on the top cap for convenience). Leave the grub screw loose. 3. Fit the supplied key over the adjusting spindle. SEE IMAGE 7 • To increase the mixed outlet temperature, rotate the spindle anti-clockwise. • To decrease the mixed outlet temperature, rotate the spindle clockwise 4. Allow the mixed outlet temperature to stabilize for 60 seconds and once again take a temperature reading. Repeat the procedure until the desired temperature has been reached. 5. Tighten the temperature adjustment locking grub screw. SEE IMAGE 6 6. Push the top cover firmly back onto the top of the valve until it ‘snaps’ back into place. 7. Check the outlet temperature is stable over the full range of flow rates and that the flow rate is adequate for the application. 8. Close the outlet. 9. The mixing valve is now set and locked! Full instructions here: www.enware.com.au/products/aquablend-1500-thermostatic-mixing-valve-lead-free-with-thermal-flush-lift-lever/aquablend-1500-thermostatic-mixing-valve-lead-free-with-thermal-flush-lift-lever/
@Allegedly2right
@Allegedly2right Жыл бұрын
Look you stick to SAS things leave plumbing things to plumbers
@primarypro1627
@primarypro1627 Жыл бұрын
HI , This is why we worked with you and made this video to show Pro installer how you have said you want it insulated 👍click link > kzbin.info/www/bejne/d2LWn5aKmLZspdE
@kevinmills5293
@kevinmills5293 Жыл бұрын
Why are they 10 times more expensive than a thermostatic radiator valve when they are basically the same thing?
@MuhammadAli-bh1dn
@MuhammadAli-bh1dn Жыл бұрын
Hello...My question, if the inlet pressure reduces to set outlet pressure... Will the pressure reducing valve will let the water pass through it... Let the set point at outlet is 1 bar and input is 3 bar.... And if the input pressure decreases to 0.1 bar.... Will the same prv let the water flow through it.. Regards
@hiitdon8630
@hiitdon8630 Жыл бұрын
🎉🎉
@Allegedly2right
@Allegedly2right Жыл бұрын
The house will be 3degrees aswell because no one can afford to turn the heat pump on so you can throw them valves in the bin along with the Grant Heat Pump.what else can you do anti freeze or what just asking.
@raymondtavener9797
@raymondtavener9797 Жыл бұрын
They are installed all throughout the Tottenham Hotspur stadium where TMV’s are not applicable I.e acessible toilets / first aid rooms but all the concourses have a sensor tap 1 single outlet with blended temperature.
@hvacgas5292
@hvacgas5292 Жыл бұрын
Would have been nice if slide or diagram was used😕