Пікірлер
@CocoTheBirb
@CocoTheBirb 2 ай бұрын
nice job dude the way it somehow coughed made it better
@Plumingoph
@Plumingoph 2 ай бұрын
Haha thanks man! I thought so too 😂
@TheWendolGuild
@TheWendolGuild 2 ай бұрын
does the display turn off or is it suppose to show the time all the time/?
@teresacaldwell957
@teresacaldwell957 4 ай бұрын
How do you get the white cover off of the timer? Thanks!
@Plumingoph
@Plumingoph 4 ай бұрын
It should just slide off
@marcoduenas205
@marcoduenas205 5 ай бұрын
I'm glad she's not the only one . ❤ She has changed many men's life's
@Plumingoph
@Plumingoph 5 ай бұрын
She sure has
@newcreatureinchrist9373
@newcreatureinchrist9373 5 ай бұрын
What is the pressure reducing valve supposed to be set to for the filtration ?
@Plumingoph
@Plumingoph 5 ай бұрын
Manufacturer says to not exceed 80 psi. Generally I’ll have them set somewhere between 60-70psi
@newcreatureinchrist9373
@newcreatureinchrist9373 5 ай бұрын
🔥🔥🔥
@jimhuntington
@jimhuntington 7 ай бұрын
You skipped over the power portion. Does it just plug into a standard 120 V receptacle?
@Plumingoph
@Plumingoph 7 ай бұрын
Sure does, it’s a plug and play
@pieatin
@pieatin 8 ай бұрын
That is Absolutely Hilarious!
@brandonleavitt8974
@brandonleavitt8974 8 ай бұрын
Did not cap the old line or the leak ???
@SMILESDaMILL
@SMILESDaMILL 8 ай бұрын
It looks like the drip leg is before the valve, it should be after so you can service it. Also in my state you have to have a CPVC or Copper to dump from T&P valve.
@jadenthomas8671
@jadenthomas8671 8 ай бұрын
Seems like people said just about everything. Couple of people should have watched the video a second time… 🙄 just cause it hasn’t been said I’m gonna say not enough air gap in the t and p. Also not seeing the pan draining to anything so it’s basically useless. Also no foam pad under it
@shottafromyard06
@shottafromyard06 8 ай бұрын
😂😂😂😂😂😂😂
@youtubecontractor
@youtubecontractor 8 ай бұрын
😂😂😂
@jasparramirez9554
@jasparramirez9554 8 ай бұрын
1/2" water line when it should be 3/4"
@plumberman5369
@plumberman5369 8 ай бұрын
I'm a plumber and I approve this message 😊
@kalansi35
@kalansi35 8 ай бұрын
No earthquake straps required for water heater in your area?
@chriscandia9870
@chriscandia9870 8 ай бұрын
Damn shes an expensive tool too. But damn i love her and what she does.
@Plumingoph
@Plumingoph 8 ай бұрын
She’s worth every penny and more ❤️😂
@seenoevil1981
@seenoevil1981 8 ай бұрын
Agreed she’s my ride or die
@Plumingoph
@Plumingoph 8 ай бұрын
🤣 hell yeah
@dustyburhans1600
@dustyburhans1600 8 ай бұрын
Maybe you could have oriented the shut off valve on the cold side further away from the ground connections so that it could function easier
@sandmastermaster
@sandmastermaster 8 ай бұрын
Usually I push excess into the wall instead of cutting it short
@Plumingoph
@Plumingoph 8 ай бұрын
Yeah nice! I definitely like to leave some excess available in the wall for sure
@rynosssj8023
@rynosssj8023 8 ай бұрын
You need to raise your water heater on a stand cause it's gas
@umbasa01
@umbasa01 8 ай бұрын
Gas flow has to hit the wall of the tee before going in?
@umbasa01
@umbasa01 8 ай бұрын
Gas heaters are supposed to be on a stand?
@umbasa01
@umbasa01 8 ай бұрын
Relief line needs to be hard pipe?
@tombush
@tombush 8 ай бұрын
Very insightful
@Plumingoph
@Plumingoph 8 ай бұрын
Glad it was helpful 💪
@kyleb1998
@kyleb1998 8 ай бұрын
I would have made the lines 3/4 a little higher
@voosum
@voosum 8 ай бұрын
Press tools sound like a turtle fucking/dieing.😅
@Plumingoph
@Plumingoph 8 ай бұрын
😂
@truth6600
@truth6600 8 ай бұрын
Expansion tank can't be supported by the pipe,and its upside-down.
@Tydiez
@Tydiez 8 ай бұрын
Is that half inch on the copper?
@tacklebox6239
@tacklebox6239 8 ай бұрын
Houston requires sediment trap at appliance, t&p needs to be cpvc/copper discharge in a drain or outside and looks like your vent baffle wasn’t seated properly
@TheMustang833
@TheMustang833 8 ай бұрын
In Texas water heater water lines or in 3/4 not 1/2”
@kevinmatulonis
@kevinmatulonis 8 ай бұрын
Yes....using pro press
@ep3thatsall485
@ep3thatsall485 8 ай бұрын
Yeah, you have no idea how to use a pipebender, too many fittings.
@Plumingoph
@Plumingoph 8 ай бұрын
😂 not true, for some reason pipe bending isn’t really a thing in America
@mikelutz4618
@mikelutz4618 8 ай бұрын
Is that pan plastic? Hard to tell but if it is, it’s incorrect.
@nightnightjd5733
@nightnightjd5733 8 ай бұрын
B setting is way too hot 😂 plus expansion tanks now have to be facing up and 18” away from vent
@Plumingoph
@Plumingoph 8 ай бұрын
Daddy likes it hot
@santanamontes266
@santanamontes266 8 ай бұрын
In Utah the expansion tank needs to be mounted in a bracket on the wall, the saddle valve should’ve been replaced with a tee and angle stop
@santanamontes266
@santanamontes266 8 ай бұрын
That’s a ground haha not a saddle valve
@Plumingoph
@Plumingoph 8 ай бұрын
😂 nice save! Not code for that in Colorado, but good guess!
@demosmash
@demosmash 8 ай бұрын
Used 3/4 put used 1/2 jaw
@timboswan6979
@timboswan6979 8 ай бұрын
you may need to support your expansion tank.
@tylermaneggia163
@tylermaneggia163 8 ай бұрын
In Connecticut it’s against code to put expansion tank upside down. Needs to be mounted on wall and piped too. Super annoying
@djmindframe99
@djmindframe99 8 ай бұрын
I'd say its missing a hammer valve.
@k_m_z_
@k_m_z_ 8 ай бұрын
Succesfully neutered the entire house's hot water capacity by undersizing the cold feed AND hot supply water lines?
@MisterTwister88
@MisterTwister88 8 ай бұрын
He connected 1/2” to existing 1/2”. Would you expect him to re-pipe the house?
@Hansel1189
@Hansel1189 8 ай бұрын
Did you tighten the hot water side?
@lazd4970
@lazd4970 8 ай бұрын
Onions?
@devinrohrbacher6271
@devinrohrbacher6271 8 ай бұрын
Didnt reconnect what was connected to the saddle valve?
@Plumingoph
@Plumingoph 8 ай бұрын
Good guess! But incorrect
@kalebhuffman403
@kalebhuffman403 8 ай бұрын
Looks good, but OSHA would have a field day with all the safety violations.
@Plumingoph
@Plumingoph 8 ай бұрын
I was admittedly surfing those ladders
@VRJones15
@VRJones15 8 ай бұрын
Nice how-to 👍🏻
@Plumingoph
@Plumingoph 8 ай бұрын
Thanks!
@Plumingoph
@Plumingoph 8 ай бұрын
Full video: kzbin.info/www/bejne/eIC4qGqnf5iBa8ksi=MedmqEh4xUSA4P96
@davet9900
@davet9900 10 ай бұрын
this song just showed up in my feed as i was listening to other vids Blue Boy - Remember Me
@tombush
@tombush 11 ай бұрын
😂
@brendannapoli4782
@brendannapoli4782 11 ай бұрын
😂😂😂
@dennismaloney7241
@dennismaloney7241 Жыл бұрын
So, I always install the tank with the Schrader valve up. My logic is that the bladder inside the tank won't have the weight of the water on it. Now some would argue that entrained air will gather beneath and cause corrosion. So with that in mind, I always replace the tank when I replace the water heater.
@Plumingoph
@Plumingoph Жыл бұрын
I hear you Dennis! I’ve installed it both ways