Пікірлер
@testvienas4611
@testvienas4611 2 сағат бұрын
my question is, why do people in US are so behind in HVAC industry? like you guys seem to live in early 2000s in terms of HVAC.
@shirvonseemungal7719
@shirvonseemungal7719 12 күн бұрын
Would like a better video showing exactly how to get the DSH , SSH ans Subcooling
@bensonmacharia2975
@bensonmacharia2975 2 ай бұрын
Roman Baugh that was very informative. 🎉🎉🎉
@RomanBaugh
@RomanBaugh Ай бұрын
Thank you!
@MelodyMan69
@MelodyMan69 3 ай бұрын
Daikin Service Checker is rubbish when compared with the LG System. Look up LGMV (Multi View) and you will see.
@Username-ng8jy
@Username-ng8jy 3 ай бұрын
The mistubishi one is better than lg
@MelodyMan69
@MelodyMan69 3 ай бұрын
@@Username-ng8jy Yes its good and covers about the same as LG do. I worked at Daikin 21 years and LG for 17 years but don't have hands on experience with the ME Product. Only stories from their Techs.
@shirvonseemungal7719
@shirvonseemungal7719 5 ай бұрын
How do we measure subcool on a vrv
@RomanBaugh
@RomanBaugh Ай бұрын
Depends on the series and mode but we should be measuring subcool using the coil temp leaving the heat exchanger. Not leaving the outdoor unit. Remember the subcooler on the unit will throw this measurement off.
@travisburks628
@travisburks628 5 ай бұрын
Can you repost the input mode list. I had it but I somehow lost it.
@mallkomoha6823
@mallkomoha6823 6 ай бұрын
Can rebroadcast the video in metric please?? I mean in degree Celsius.
@RomanBaugh
@RomanBaugh Ай бұрын
I can but converting to Celsius is not difficult.
@BleedingEdgeHVACandTech
@BleedingEdgeHVACandTech 6 ай бұрын
Sorry I’m confused is discharge superheat calculated by taking Discharge line temp-Discharge sat temp or Discharge line temp-Liquid sat temp?
@RomanBaugh
@RomanBaugh Ай бұрын
Discharge, liquid, hotgas, suction, it all doesnt matter. What matters is pressure converted to saturation temp. So call it whatever you want but DSH is leaving compressor temp minus pressure converted to saturation temperature at that same spot. So yes Discharge temp - head pressure converted to saturation temp or Tc.
@jorgevalladares179
@jorgevalladares179 7 ай бұрын
Are the examples shown, reflect a system running on heat?
@RomanBaugh
@RomanBaugh 6 ай бұрын
Heat, Cooling, heat recovery it’s all relevant as long as you know the correct locations of where to measure these temperatures.
@garypoplin4599
@garypoplin4599 8 ай бұрын
1:34 - Where do you put your probes to get the numbers for calculating discharge superheat? My understanding of the discharge superheat calculation is discharge line temperature less liquid line pressure (converted to temperature). Is that right?
@RomanBaugh
@RomanBaugh 6 ай бұрын
Discharge superheat is measured using discharge line temperature 6” down stream of compressor then subtracting it from liquid line temp converted to saturation temp. 180-110 = 70 DSH.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 8 ай бұрын
Great video
@RomanBaugh
@RomanBaugh 8 ай бұрын
Glad you enjoyed it
@DanFornal-r7t
@DanFornal-r7t 9 ай бұрын
How do I view the refrigerant piping diagram?
@vincebaldacchino-v8m
@vincebaldacchino-v8m 9 ай бұрын
great bit of info from you as usual
@RomanBaugh
@RomanBaugh 8 ай бұрын
Thanks!
@buggedmechanics
@buggedmechanics 9 ай бұрын
Great video
@RomanBaugh
@RomanBaugh 9 ай бұрын
Glad you enjoyed it
@Scottyboyhvacdude
@Scottyboyhvacdude 9 ай бұрын
I cant believe ive looked at this for 14 yrs and had no idea what these control modes were. Many thanks bro
@RomanBaugh
@RomanBaugh 9 ай бұрын
Glad I could help!
@hamdyhelal4000
@hamdyhelal4000 9 ай бұрын
great info, thanks, can you share service manual no.
@RomanBaugh
@RomanBaugh 9 ай бұрын
Yes I can
@jevonhoward
@jevonhoward 9 ай бұрын
So I'm still on service checker 3. Is outdoor suction temp(line item 77) air entering outdoor coil? I would want to use suction pipe temp(line item 79) minus evaporator temp to calculate superheat correct? Do I not have operation mode on service checker 3?
@RomanBaugh
@RomanBaugh 9 ай бұрын
What is the model of your equipment? Based upon the model it may have 2 suction temp sensors. Yes thats correct VRV4 and newer is the only models with Control Modes.
@jevonhoward
@jevonhoward 9 ай бұрын
@@RomanBaugh REYQ144TAYDU
@anasal-muhur3587
@anasal-muhur3587 9 ай бұрын
great, thank you
@RomanBaugh
@RomanBaugh 9 ай бұрын
Glad you liked it!
@guuuuustaf
@guuuuustaf 9 ай бұрын
Do you know the process of Daikin minisplit, how do they calculate evaporating temp and condensing temp. Since they do not have pressure transmitters. Only discharge probe, ev probe and condensing probes, and air thermistor probes. Do they calculate evaporating and condensing temperatures via the compressor load ampere, and also take into account the heatexchanger probes? Its bugging me for real. Hope you have somewhat of an answer.=)
@ryanbrown7134
@ryanbrown7134 9 ай бұрын
Short answer is they don’t. Thermistor data is all that is used to control the motor speeds and valve pulses. At least that’s what is taught in the mini split class.
@guuuuustaf
@guuuuustaf 9 ай бұрын
@@ryanbrown7134 Then how can they get correct sh and sc? Its been bugging me how are they actually know how to adjust the eev. Some of the data needed for correct sh, sc is unknown. They must use ampere drawn by the compressor too trying to get somewhat of correct ev pressure and condensing pressure... 😁
@ryanbrown7134
@ryanbrown7134 9 ай бұрын
@@guuuuustaf It bothered me too when I first started working on them. They don’t monitor superheat or subcooling. They may have an algorithm that determines wet operation with compressor current and discharge temp but I doubt it. Even if they did, they wouldn’t tell us anyways. Other than the logic, mini splits are very simple units.
@guuuuustaf
@guuuuustaf 9 ай бұрын
Haha okeey thank you for the answer=). may be therefore they often have two accumulator tanks beside compressor. Cause the sh cant always be 100%.They are indeed very simple. The logic as you say is the more tricky part. @@ryanbrown7134
@Jonathan-li1xh
@Jonathan-li1xh 9 ай бұрын
If the units don’t have the pressure sensor , it should have thermistor at the evap and at the condenser coil . These temperature will be used for evap temperature and condensation temperature instead pressure reading converted into sat temperature.
@wojciechkobierski1913
@wojciechkobierski1913 10 ай бұрын
Is there any manual that describes what exactly happens during each mode?
@RomanBaugh
@RomanBaugh 9 ай бұрын
Yes all of these items are in the appropriate service manual for that model unit.
@bjaquez27
@bjaquez27 10 ай бұрын
Thank you Roman. We been ordering for months now. Sometimes only get a solenoid valve and coil only. I always tell them send me the entire assembly.
@RomanBaugh
@RomanBaugh 10 ай бұрын
Glad to help
@guuuuustaf
@guuuuustaf 11 ай бұрын
Great explanation!
@RomanBaugh
@RomanBaugh 10 ай бұрын
Glad it was helpful!
@dcfabrication2097
@dcfabrication2097 11 ай бұрын
We appreciate you Roman
@RomanBaugh
@RomanBaugh 10 ай бұрын
Thanks!
@DaneSetser-nn9xc
@DaneSetser-nn9xc 11 ай бұрын
I’ve got a total of 9 systems of 4X heat recovery units. We have had multiple issues and lost compressors. Your video made me dive deep into these systems. One system in particular is running a high DSH 90-100. SSH is within range no higher that 32 sometimes drops less in five. Subcool is within range. I did an oil differential across the suction line and was getting 7F then jumped up to almost 40F. Do you have any more info. Also where did you get the 30 modes local Daikin rep doesn’t have it.
@RomanBaugh
@RomanBaugh 11 ай бұрын
Sounds like oil traps within the building. High DSH levels with normal range SSH and Subcooling means your compressors are low on oil. Sounds like piping errors or discrepancies. Meaning there are piping rules broken causing oil to become trapped in the system. Your local Daikin Rep will not have that list, as I translated it from Japanese. Daikin Japan is the only one with the list prior to now.
@DaneSetser-nn9xc
@DaneSetser-nn9xc 11 ай бұрын
Thank you I’ll start looking at the piping.
@robertbethell4795
@robertbethell4795 11 ай бұрын
Opening up a compressor
@RomanBaugh
@RomanBaugh 11 ай бұрын
Yes sir
@travisburks628
@travisburks628 Жыл бұрын
Where can we find the operation code list? I have been looking through the service manual. Iis there something you can share?
@RomanBaugh
@RomanBaugh Жыл бұрын
I will be posting it soon with an updated version.
@travisburks628
@travisburks628 11 ай бұрын
I really enjoy your videos.
@dawain
@dawain 6 ай бұрын
Wow! I am in❤ w/ this Guy 🧠….
@hvacgirlo
@hvacgirlo Жыл бұрын
VRV legend Roman!!
@RomanBaugh
@RomanBaugh Жыл бұрын
I dont know about all that. Just a guy who is passionate about VRV/F
@cedric0057
@cedric0057 Жыл бұрын
I have worked for Daikin for many years in France and have never had this information. I've been seeing this number and trying to say "what does that mean" for a long time. Many thanks for your work and for sharing. good game.
@RomanBaugh
@RomanBaugh Жыл бұрын
I am glad you liked the video! More to come!
@tom24057
@tom24057 Жыл бұрын
More VRV content would be great Roman!!? 😅😅
@RomanBaugh
@RomanBaugh Жыл бұрын
You got it!
@tom24057
@tom24057 Жыл бұрын
@@RomanBaugh awesome. Here in the UK Daikin aren’t forthcoming with this information. Even their Multichecker training courses are average at best
@ashleydavies7863
@ashleydavies7863 Жыл бұрын
Are the temperature figures in Fahrenheit or Celsius? As I'm in the UK
@RomanBaugh
@RomanBaugh 11 ай бұрын
Fahrenheit good sir
@marcoferreira226
@marcoferreira226 Жыл бұрын
I have a question are your Temps F or C?
@RomanBaugh
@RomanBaugh 11 ай бұрын
Fahrenheit
@LC-qi5ff
@LC-qi5ff Жыл бұрын
How does overcharge cause low oil in compressor?
@tom24057
@tom24057 Жыл бұрын
Flushes out oil
@RomanBaugh
@RomanBaugh 11 ай бұрын
System never runs the compressor over half speed causing velocity to be low not allowing refrigerant to bring oil back from the indoor units. Couple that with liquid flood back then compounds the issue removing any remaining oil from the compressor.
@AskewCooling
@AskewCooling Жыл бұрын
Hi Roman, great video could you advise of these figures you refer to in deg C i.e. DSH range (27 to72), SSH range (3.6 to 32) & LSC range (11)
@RomanBaugh
@RomanBaugh 11 ай бұрын
Fahrenheit my friend
@omegma87
@omegma87 Жыл бұрын
Thank you.
@prowesstv
@prowesstv Жыл бұрын
Bro got me locked in for the deep dive then only has two videos 😅😅
@RomanBaugh
@RomanBaugh 11 ай бұрын
The wait is over
@WallaceRoseVincent
@WallaceRoseVincent Жыл бұрын
Wish you had the actual parts on hand.
@RomanBaugh
@RomanBaugh 11 ай бұрын
Of course we all do, however as a technician we have to just wing it sometimes
@jeffendrulat3530
@jeffendrulat3530 Жыл бұрын
Thanks Roman..... Best 20 minutes that I spent today!
@Didik-cq8wy
@Didik-cq8wy Жыл бұрын
Trimaksih bos
@ping_me1vp
@ping_me1vp Жыл бұрын
That's soo excellent thanks a million
@RomanBaugh
@RomanBaugh Ай бұрын
Anytime
@nguyennam880
@nguyennam880 Жыл бұрын
Looking forward to you sharing your knowledge related to data analysis checker. Thanks you.
@RomanBaugh
@RomanBaugh 11 ай бұрын
The wait is over
@karaors8970
@karaors8970 Жыл бұрын
Nice bro.🤳🛠️🧿👍
@phillipcase8036
@phillipcase8036 Жыл бұрын
Thank you for your informational video it shows these units can be worked on and we just need to dig deeper
@HVACR_VINYLS
@HVACR_VINYLS Жыл бұрын
Another roman video. Oh shit yeh 💪
@HVACR_VINYLS
@HVACR_VINYLS Жыл бұрын
Hey Roman. When I’m using my service checker on a VRV 4. I have noticed the eev pulses have 2 sets of data. Eg it has upper heat exchanger eev pulses, and then upper heat exchanger eev US pulse. What does the US dictate? I don’t use it in my diagnosis, I’m just curious to what it refers too.
@RomanBaugh
@RomanBaugh Жыл бұрын
Yes there are two different sets, however do not us the (US) valve pulses as they are not for our market and will be misleading.
@HVACR_VINYLS
@HVACR_VINYLS Жыл бұрын
@Roman Baugh thanks legend. Appreciate it
@Scottyboyhvacdude
@Scottyboyhvacdude Жыл бұрын
How long before you have to take this down?
@tom24057
@tom24057 Жыл бұрын
Why?
@RomanBaugh
@RomanBaugh 8 ай бұрын
Still up Scott 😂
@Scottyboyhvacdude
@Scottyboyhvacdude 8 ай бұрын
@@RomanBaugh I only say that because there's been some other helpful daikin content that was taken down. I don't understand the secrecy. We as technicians need any tools we can get, thank you!!
@epicone2449
@epicone2449 Жыл бұрын
More videos please. Good job 👍🏼 I thought VRV 3 and VRV 4 have different ranges in permissible values
@RomanBaugh
@RomanBaugh 11 ай бұрын
No same ranges as they share similar compressors.
@cchurch816
@cchurch816 Жыл бұрын
Also sensors and transducers. How to verify they work right
@jorgevalladares179
@jorgevalladares179 7 ай бұрын
Without getting into the math, Daikin has two apps that can help you convert that. Daikin tech and Daikin services, it’ll convert dc voltage to pressure (vise versa) and temps to ohm (vise versa). Then get gauges or temp probes and see if they correlate.
@cchurch816
@cchurch816 Жыл бұрын
But keeping them videos comming.
@cchurch816
@cchurch816 Жыл бұрын
U sound like u think all techs have basic schooling in refrigeration theory.
@epicone2449
@epicone2449 Жыл бұрын
You need to know the basics before diving into VRV. Like experienced in service on package units or split systems
@cchurch816
@cchurch816 Жыл бұрын
​@@epicone2449 looked for the dsh, sc and sh on a daikin fit heat pump couple days using the daikin btsc app. The symbols arnt matchin on the app. Reverted to just using to probes. Went after the dsh and sh in heating mode. Looked normal. Last tech suspected low charge after the tstat error history shows low pressure trip. Found the data wire was grounded at the equipment chasis and corrected it.
@johnchiarello1375
@johnchiarello1375 Жыл бұрын
Great video